Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites
Open accessAbstract
It is accepted that older subjects have increasing arterial stiffness resulting in changes in the propagation of the pulse to the periphery, and thereby influencing the peripheral pulse timing and shape characteristics. However, this age association with pulse shape is less clear in younger subjects and for different peripheral measurement sites. The aim of this study was to determine the association between age and changes in pulse shape characteristics at the ears, fingers and toes. Photoplethysmography pulse waveforms were recorded non-invasively from the right and left sides at the ears, index fingers and great toes of 116 normal healthy human subjects. Their median age was 41 years (range 13-72) allowing four distinct age groups to be considered (subjects younger than 30 years, 30-39 years, 40-49 years and 50 years of age or older). Normalized ear, finger and toe pulse shapes were calculated, for the whole subject group, and for the subjects within each age group. The differences in shape, relative to the oldest group, were also calculated for two distinct regions of interest: the systolic rising edge and the dicrotic notch of the pulse. Subtle, gradual and significant changes in the pulse shape were found at all sites with overall elongation of the systolic rising edge (p < 0.05) and damping of the dicrotic notch (p < 0.05) with age. The overall age-related changes in multi-site PPG pulse shape characteristics at the ear, finger and toe sites have been demonstrated and quantified. Age-matched normal ranges must be considered when evaluating pulses from patients with possible vascular disease.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Corroborating with other literature, an increase in pulse wave velocity with age is related to a diminished dicrotic notch.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [90]
In the citing paper
“| Dicrotic notch shape | Decrease | Allen et al., 2003 | [90] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [90]
In the citing paper
“| Artery compliance | Decrease | Knight et al., 2017 Allen et al., 2002 | [78,90] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [90]
In the citing paper
“| Systolic rising edge slope | Decrease | Allen et al., 2003 | [90] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [90]
In the citing paper
“Allen and Murray have noted that PPG waveforms are largely similar between bilateral anatomies at the ear, finger, and toe at rest, according to their study featuring 116 (68 male, 48 female) healthy Caucasian subjects with a median age of 43 [90].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [90]
Citations
Cites
Digital Signal Processing: A Practical Approach
Ifeachor, E., Jervis, B. W., Dagless, E. L., & O'Reilly, J. O. (1993) · Medical Entomology and Zoology · Cited by 1,220
Fowkes, F. G. R., Housley, E., Cawood, E. H. H., Macintyre, C. C. A., Ruckley, C. V., & Prescott, R. J. (1991) · International Journal of Epidemiology · doi:10.1093/ije/20.2.384 · Cited by 1,179
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
Millasseau, S., Kelly, R. P., Ritter, J., & Chowienczyk, P. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 624
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
(1996) · PubMed · Cited by 330
Bortolotto, L. A., Blacher, J., Kondo, T., Takazawa, K., & Safar, M. E. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00192-2 · Cited by 272
The peripheral pulse wave: Information overlooked
Murray, W. B., & Foster, P. A. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02077634 · Cited by 231
The difference in pulse transit time to the toe and finger measured by photoplethysmography
Nitzan, M., Khanokh, B., & Slovik, Y. (2001) · Physiological Measurement · doi:10.1088/0967-3334/23/1/308 · Cited by 218
Hjemdahl, P., & Friberg, P. (1996) · Journal of Hypertension · doi:10.1097/00004872-199602000-00001 · Cited by 196
Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179
Self-citation
Research works printed but not linked: 5
- Barnes R W, 1991, Circulation, 83, I20
- Challoner A V J, 1979, 1, 127
- Oliva I, 1976, VASA, 5, 95
- 10.1023/A:1016936206694 · DOI
- Wilkinson I B, 1998, J. Cardiovasc. Pharmacol., 3, S33
Cited by
Sorted by citations
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Self-citationPhotoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 589
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
“Allen and Murray have noted that PPG waveforms are largely similar between bilateral anatomies at the ear, finger, and toe at rest, according to their study featuring 116 (68 male, 48 female) healthy Caucasian subjects with a median age of 43 [90].”
BackgroundHeart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
Charlton, P. H., Harana, J. M., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J. (2019) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2019 · Cited by 269
de Zambotti, M., Goldstein, C. A., Cook, J. D., Menghini, L., Altini, M., Cheng, P., & Robillard, R. (2023) · SLEEP · doi:10.1093/sleep/zsad325 · Cited by 276
Stergiou, G. S., Mukkamala, R., Avolio, A. P., Kyriakoulis, K. G., Mieke, S., Murray, A., Parati, G., Schutte, A. E., Sharman, J. E., Asmar, R. G., et al. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003224 · Cited by 231
Self-citationEmerging Design and Characterization Guidelines for Polymer-Based Infrared Photodetectors
Wu, Z., Zhai, Y., Kim, H., Azoulay, J. D., & Ng, T. N. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00446 · Cited by 227
Adaptive threshold method for the peak detection of photoplethysmographic waveform
Shin, H. S., Lee, C., & Lee, M. (2009) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.10.006 · Cited by 211
Smith, R. S., Kuplicki, R., Feinstein, J. S., Forthman, K. L., Stewart, J. L., Paulus, M. P., Tulsa 1000 investigators, & Khalsa, S. S. (2020) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1008484 · Cited by 207
Hartmann, V., Liu, H., Chen, F., Qiu, Q., Hughes, S., & Zheng, D. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00198 · Cited by 173
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171
Charlton, P. H., Paliakaitė, B., Pilt, K., Bachler, M., Zanelli, S., Kulin, D., Allen, J., Hallab, M., Bianchini, E., Mayer, C. C., et al. (2021) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00392.2021 · Cited by 166
Self-citationShin, H., & Min, S. D. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0302-y · Cited by 145
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
Self-citationAllen, J., Oates, C. P., Lees, T. A., & Murray, A. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/018 · Cited by 112
Self-citationDu, Y., & Stephanus, A. (2018) · Sensors · doi:10.3390/s18072322 · Cited by 107
Toward Generating More Diagnostic Features from Photoplethysmogram Waveforms
Elgendi, M., Liang, Y., & Ward, R. K. (2018) · Diseases · doi:10.3390/diseases6010020 · Cited by 107
Hypertension Assessment Using Photoplethysmography: A Risk Stratification Approach
Liang, Y., Chen, Z., Ward, R. K., & Elgendi, M. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm8010012 · Cited by 99
Xing, X., Ma, Z., Zhang, M., Zhou, Y., Dong, W., & Song, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-45175-2 · Cited by 101
Wang, L., Xu, L., Feng, S., Meng, M. Q. ‐., & Wang, K. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.08.004 · Cited by 90
Nadi Tarangini: A Pulse Based Diagnostic System
Joshi, A. J., Kulkarni, A., Chandran, S., Jayaraman, V., & Kulkarni, B. D. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352762 · Cited by 90
Smith, R. S., Feinstein, J. S., Kuplicki, R., Forthman, K. L., Stewart, J. L., Paulus, M. P., Tulsa 1000 Investigators, Aupperle, R. L., Bodurka, J., Savitz, J. B., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-81307-3 · Cited by 89
InstaBP: Cuff-less Blood Pressure Monitoring on Smartphone using Single PPG Sensor
Dey, J., Gaurav, A., & Tiwari, V. N. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513189 · Cited by 79
Robust PPG motion artifact detection using a 1-D convolution neural network
Goh, C., Tan, L. K., Lovell, N. H., Ng, S., Tan, M. P., & Lim, E. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105596 · Cited by 83
Advanced Uses of Pulse Oximetry for Monitoring Mechanically Ventilated Patients
Tusman, G., Böhm, S. H., & Suárez-Sipmann, F. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001283 · Cited by 72
Modeling of the photoplethysmogram during atrial fibrillation
Sološenko, A., Petrėnas, A., Marozas, V., & Sörnmo, L. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.12.016 · Cited by 69
Nissen, M., Slim, S., Jaeger, K. M., Flaucher, M., Huebner, H., Danzberger, N., Fasching, P. A., Beckmann, M. W., Gradl, S., & Eskofier, B. M. (2022) · JMIR Formative Research · doi:10.2196/33635 · Cited by 69
Tracking cerebral blood flow in BOLD fMRI using recursively generated regressors
Tong, Y., & Frederick, B. B. (2014) · Human Brain Mapping · doi:10.1002/hbm.22564 · Cited by 66
Kushki, A., Fairley, J. A., Merja, S., King, G. A., & Chau, T. T. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/10/002 · Cited by 63
Photoplethysmographic signal waveform index for detection of increased arterial stiffness
Pilt, K., Meigas, K., Ferenets, R., Temitski, K., & Viigimaa, M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/10/2027 · Cited by 62
Zahedi, E., Chellappan, K., Ali, M. A. M., & Singh, H. (2007) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-007-9037-5 · Cited by 60
Recent advances in high speed diffuse optical imaging in biomedicine
Applegate, M. B., Istfan, R., Spink, S. S., Tank, A., & Roblyer, D. M. (2020) · APL Photonics · doi:10.1063/1.5139647 · Cited by 60
Chen, Y., Wen, C., Tao, G., & Bi, M. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0467-2 · Cited by 59
Bentham, M., Stansby, G. P., & Allen, J. (2018) · Diseases · doi:10.3390/diseases6030081 · Cited by 60
Self-citationEffects of filtering on multi-site photoplethysmography pulse waveform characteristics
Allen, J., & Murray, A. (2005) · Computers in cardiology · doi:10.1109/cic.2004.1442980 · Cited by 56
Self-citationPhotoplethysmography Analysis of Artery Properties in Patients with Cardiovascular Diseases
Rubīns, U., Grabovskis, A., Grūbe, J., & Kukulis, I. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69367-3_85 · Cited by 55
Tusman, G., Acosta, C. M., Pulletz, S., Böhm, S. H., Scandurra, A. G., Arca, J. M., Madorno, M., & Suárez-Sipmann, F. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-018-0235-z · Cited by 54
Bilateral photoplethysmography studies of the leg arterial stenosis
Erts, R., Spīgulis, J., Kukulis, I., & Ozols, M. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/022 · Cited by 52
Liu, H., Allen, J., Khalid, S. G., Chen, F., & Zheng, D. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac0a34 · Cited by 50
Self-citationWearable speckle plethysmography (SPG) for characterizing microvascular flow and resistance
Ghijsen, M. T., Rice, T. B., Yang, B. Y., White, S. M., & Tromberg, B. J. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.003937 · Cited by 46
Digital pulse contour analysis: investigating age-dependent indices of arterial compliance
Brumfield, A., & Andrew, M. E. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/003 · Cited by 45
Hsu, P.-C., Wu, H., & Sun, C. (2018) · Journal of Medical Systems · doi:10.1007/s10916-018-0901-1 · Cited by 44
Photoplethysmography—new applications for an old technology: a sleep technology review
Ryals, S. M., Chiang, A. A.-P., Schutte-Rodin, S., Chandrakantan, A., Verma, N., Holfinger, S. J., Abbasi-Feinberg, F., Bandyopadhyay, A., Baron, K. G., Bhargava, S., et al. (2022) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10300 · Cited by 43
Surgical pleth index monitoring in perioperative pain management: usefulness and limitations
Oh, S. K., Won, Y. J., & Lim, B. G. (2023) · Korean Journal of Anesthesiology · doi:10.4097/kja.23158 · Cited by 43
Wu, H., Liu, C.-C., Lin, P.-H., Chung, H.-M., Liu, M.-C., Yip, H., Liu, A., & Sun, C. (2010) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2010.08.075 · Cited by 40
Photoplethysmography Assessments in Cardiovascular Disease
Allen, J., Overbeck, K., Stansby, G. P., & Murray, A. (2006) · Measurement and Control · doi:10.1177/002029400603900303 · Cited by 37
Self-citationLiu, B., Zhang, Z., Di, X., Wang, X., Xie, L., Xie, W., & Zhang, J. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.733264 · Cited by 35
Photoplethysmogram second derivative review: Analysis and applications
Yousef, K. Q., Rubīns, U., & Alharbi, M. (2015) · Scientific Research and Essays · doi:10.5897/sre2015.6322 · Cited by 35
Age-related changes in pulse risetime measured by multi-site photoplethysmography
Allen, J., O’Sullivan, J. J., Stansby, G. P., & Murray, A. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab9b67 · Cited by 34
Self-citationEstimation of phase distortions of the photoplethysmographic signal in digital IIR filtering
Lapitan, D. G., Рогаткин, Д. А., Molchanova, E. A., & Tarasov, A. P. (2024) · Scientific Reports · doi:10.1038/s41598-024-57297-3 · Cited by 34
Deep Learning Fused Wearable Pressure and PPG Data for Accurate Heart Rate Monitoring
Mehrgardt, P., Khushi, M., Poon, S. K.-S., & Withana, A. I. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3123243 · Cited by 37
Pham, T. D., Thang, T. C., Oyama-Higa, M., & Sugiyama, M. (2013) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2013.03.010 · Cited by 31
Lee, J., Matsumura, K., Yamakoshi, T., Rolfe, P. J., Tanaka, N., Kim, K.-H., & Yamakoshi, K.-I. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/3/359 · Cited by 31
Coutrot, M., Joachim, J., Dépret, F., Millasseau, S., Nougue, H., Matéo, J., Mebazaa, A., Gayat, É., & Vallée, F. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.01.037 · Cited by 30
Comparison of selected parametric models for analysis of the photoplethysmographic signal
Shariati, N. H., & Zahedi, E. (2005) · International Conference on Computers, Communications, and Signal Processing with Special Track on Biomedical Engineering (CCSP) · doi:10.1109/ccsp.2005.4977182 · Cited by 30
Estimation of breathing interval from the photoplethysmographic signals in children
Foo, J. Y. A., & Wilson, S. J. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/6/014 · Cited by 30
Jaryal, A. K., Selvaraj, N., Santhosh, J., Anand, S., & Deepak, K. K. (2009) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-009-9174-z · Cited by 28
Silva, R., Salvador, G. F. D., Bota, P. J., Fred, A. L. N., & Silva, H. (2022) · Neural Computing and Applications · doi:10.1007/s00521-022-07212-6 · Cited by 26
Mejía‐Mejía, E., May, J. M., & Kyriacou, P. A. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106724 · Cited by 26
Pulse Wave Velocity Prediction and Compliance Assessment in Elastic Arterial Segments
Lillie, J. S., Liberson, A. S., Mix, D., Schwarz, K. Q., Chandra, A., Phillips, D. B., Day, S. W., & Borkholder, D. A. (2014) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-014-0202-x · Cited by 26
Sex-Related Differences in Photoplethysmography Signals Measured From Finger and Toe
Dehghanojamahalleh, S., & Kaya, M. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2938506 · Cited by 25
Pulsatile and steady-state hemodynamics of the human patella bone by diffuse optical spectroscopy
Farzam, P., Zirak, P., Binzoni, T., & Durduran, T. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/839 · Cited by 28
Lin, C. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.06.014 · Cited by 24
Shin, H., Sun, S., Lee, J., & Kim, H. C. (2021) · IEEE Access · doi:10.1109/access.2021.3078534 · Cited by 26
Smith, R. S., Kuplicki, R., Teed, A. R., Upshaw, V., & Khalsa, S. S. (2020) · Communications in computer and information science · doi:10.1007/978-3-030-64919-7_16 · Cited by 23
Non-invasive Studies on Age Related Parameters Using a Blood Volume Pulse Sensor
Jayasree, V. K., Sandhya, T., & Radhakrishnan, P. (2008) · Measurement Science Review · doi:10.2478/v10048-008-0020-0 · Cited by 23
Ho, M. Y., Pham, H. M., Saeed, A., & Ma, D. (2025) · Scientific Data · doi:10.1038/s41597-025-04453-7 · Cited by 25
Won, Y. J., Oh, S. K., Lim, B. G., Kim, Y. S., Lee, D. Y., & Lee, J. H. (2023) · BMC Anesthesiology · doi:10.1186/s12871-023-02011-5 · Cited by 22
Chen, X. '., Chen, T., Luo, F., & Li, J. (2013) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2013.6746936 · Cited by 22
Investigation on Pulse Wave Forward Peak Detection and Its Applications in Cardiovascular Health
Lin, W.-H., Zheng, D., Li, G., Zhou, H. D., & Chen, F. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3103552 · Cited by 20
Azudin, K., Gan, K. B., Jaafar, R., & Jaáfar, M. H. (2023) · Sensors · doi:10.3390/s23146484 · Cited by 24
Sharkey, E., Maria, C. D., Klinge, A., Murray, A., Zheng, D., O’Sullivan, J. J., & Allen, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac76a · Cited by 20
Self-citationDeriving Accurate Nocturnal Heart Rate, rMSSD and Frequency HRV from the Oura Ring
Liang, T., Yılmaz, G., & Soon, C. S. (2024) · Sensors · doi:10.3390/s24237475 · Cited by 19
Glaucomatous and Age-Related Changes in Corneal Pulsation Shape. The Ocular Dicrotism
Danielewska, M. E., Krzyżanowska-Berkowska, P., & Iskander, D. R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102814 · Cited by 19
Quality Assessment and Morphological Analysis of Photoplethysmography in Daily Life
Moscato, S., Palmerini, L., Palumbo, P., & Chiari, L. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.912353 · Cited by 21
Lavalley, C. A., Hakimi, N., Taylor, S., Kuplicki, R., Forthman, K. L., Stewart, J. L., Paulus, M. P., Khalsa, S. S., & Smith, R. S. (2023) · Biological Psychology · doi:10.1016/j.biopsycho.2024.108825 · Cited by 32
Wang, A., Yang, L., Liu, C., Cui, J., Li, Y., Yang, X., Zhang, S., & Zheng, D. (2015) · BioMed Research International · doi:10.1155/2015/752570 · Cited by 19
Pal, R., Rudas, Á., Kim, S., Chiang, J. N., Barney, A. M., & Cannesson, M. P. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108283 · Cited by 22
Age‐Related Changes in Corneal Pulsation
Danielewska, M. E., Iskander, D. R., & Krzyżanowska-Berkowska, P. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000113 · Cited by 17
Wu, K.-C., Martin, A., Renna, M., Robinson, M. B., Ozana, N. N., Carp, S. A., & Franceschini, M. A. (2023) · Neurophotonics · doi:10.1117/1.nph.10.3.035008 · Cited by 17
PPG EduKit: An Adjustable Photoplethysmography Evaluation System for Educational Activities
Morillo, Á. S., Cause, J. L., Baciu, V.-E., da Silva, B., Naranjo, J. C. G., & Stiens, J. H. (2022) · Sensors · doi:10.3390/s22041389 · Cited by 18
Age-Related Changes in Blood Volume Pulse Wave at Fingers and Ears
Lin, W.-H., Zheng, D., Li, G., & Chen, F. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3282796 · Cited by 16
Cortical thinning is associated with brain pulsatility in older adults: An MRI and NIRS study
Mohammadi, H., Peng, K., Kassab, A., Nigam, A., Bherer, L., Lesage, F., & Joanette, Y. (2021) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2021.05.002 · Cited by 18
Insights into vascular physiology from sleep photoplethysmography
Yılmaz, G., Ong, J. L., Ling, L. H., & Chee, M. W. L. (2023) · SLEEP · doi:10.1093/sleep/zsad172 · Cited by 18
Classification of vascular function in upper limb using bilateral photoplethysmographic signals
Shariati, N. H., Zahedi, E., & Jajai, H. M. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/3/007 · Cited by 14
Pham, T. D., Oyama-Higa, M., Truong, C.-T., Okamoto, K., Futaba, T., Kanemoto, S., Sugiyama, M., & Lampe, L. A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0118739 · Cited by 14
Huang, X., Schmelter, F., Uhlig, A., Irshad, M. T., Nisar, M. A., Piet, A., Jablonski, L., Witt, O., Schröder, T., Sina, C., et al. (2024) · Intelligent Medicine · doi:10.1016/j.imed.2024.05.002 · Cited by 13
Liao, S., Liu, H., Lin, W.-H., Zheng, D., & Chen, F. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1172150 · Cited by 11
Lapitan, D. G., Tarasov, A. P., & Рогаткин, Д. А. (2022) · Journal of Biomedical Photonics & Engineering · doi:10.18287/jbpe22.08.030306 · Cited by 11
Xin, S.-Z., Hu, S., Crabtree, V. P., Zheng, J., Azorin-Peris, V., Echiadis, A., & Smith, P. R. (2007) · Journal of Zhejiang University. Science A · doi:10.1631/jzus.2007.a0916 · Cited by 11
van Velzen, M. H. N., Loeve, A. J., Kortekaas, M. C., Niehof, S. P., Mik, E. G., & Stolker, R. J. (2015) · Physiological Measurement · doi:10.1088/0967-3334/37/1/52 · Cited by 11
Wang, A., Yang, L., Wen, W., Zhang, S., Gu, G., & Zheng, D. (2017) · Microvascular Research · doi:10.1016/j.mvr.2017.03.008 · Cited by 11
A photoplethysmographic imaging system with supplementary capabilities
Corral-Martínez, L. F., Paez, G., & Strojnik, M. (2014) · Prace Naukowe Uniwersytetu Ekonomicznego we Wrocławiu · doi:10.5277/oa140202 · Cited by 10
Liu, C., Zheng, D., & Murray, A. (2015) · Medicine · doi:10.1097/md.0000000000001831 · Cited by 9
Self-citationThe Striking Need for Age Diverse Pulse Oximeter Databases
Elgendi, M., Fletcher, R., Tomar, H., Allen, J., Ward, R. K., & Menon, C. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.782422 · Cited by 10
Self-citationLi, D., Xu, Y., & Gao, W. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105156 · Cited by 10
Influence of respiratory rate on the variability of blood volume pulse characteristics
Selvaraj, N., Jaryal, A. K., Santhosh, J., Deepak, K. K., & Anand, S. (2009) · Journal of Medical Engineering & Technology · doi:10.1080/03091900802454483 · Cited by 9
Lee, J., Yang, S.-M., Park, J., Kim, H. C., Kim, E., Jang, Y., Kim, J., & Kim, H. (2018) · Pediatric Anesthesia · doi:10.1111/pan.13415 · Cited by 9
Johnson, M. S. S., & Eklund, J. M. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc44109.2020.9175827 · Cited by 7
Metadata
- Authors
- Allen, J., & Murray, A.
- Affiliations
- Freeman Hospital (GB)
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2003-03-13
- Volume
- 24
- Issue
- 2
- Pages
- 297-307
- ISSN
- 0967-3334 (ISSN-L)
- OpenAlex
- W1982898684
- Cited by
- 202
- References
- 22
- Citations by year
- 2026: 12 · 2025: 8 · 2024: 13 · 2023: 18 · 2022: 17 · 2021: 17 · 2020: 11 · 2019: 6 · 2018: 15 · 2017: 7 · 2016: 7 · 2015: 8 · 2014: 10 · 2013: 9 · 2012: 8
- FWCI
- 2.64
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Newcastle University ePrints (Newcastle Univesity)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmography, pulse shape, aging, arterial stiffness, pulse wave propagation, dicrotic notch, age-related changes
- MeSH terms
- Adolescent, Adult, Aged, Aging, Arteries, Ear, Female, Fingers, Humans, Male, Middle Aged, Plethysmography, Pulsatile Flow, Toes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review