On the suitability of near-infrared (NIR) systems for next-generation brain–computer interfaces
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) gives those suffering from neuromuscular impairments a means to interact and communicate with their surrounding environment. A BCI translates physiological signals, typically electrical, detected from the brain to control an output device. A significant problem with current BCIs is the lengthy training periods involved for proficient usage, which can often lead to frustration and anxiety on the part of the user. Ultimately this can lead to abandonment of the device. The primary reason for this is that relatively indirect measures of cognitive function, as can be gleaned from the electroencephalogram (EEG), are harnessed. A more suitable and usable interface would need to measure cognitive function more directly. In order to do this, new measurement modalities, signal acquisition and processing, and translation algorithms need to be addressed. In this paper, we propose a novel approach, using non-invasive near-infrared imaging technology to develop a user-friendly optical BCI. As an alternative to the traditional EEG-based devices, we have used practical non-invasive optical techniques to detect characteristic haemodynamic responses due to motor imagery and consequently created an accessible BCI that is simple to attach and requires little user training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
Brain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685
Direct control of a computer from the human central nervous system
Kennedy, P. R., Bakay, R. A. E., Moore, M. M., Adams, K., & Goldwaithe, J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847815 · Cited by 573
Coupling of brain activity and cerebral blood flow: basis of functional neuroimaging.
Villringer, A., & Dirnagl, U. (1995) · PubMed · Cited by 566
Brain-computer communication: Unlocking the locked in.
Kübler, A., Kotchoubey, B., Kaiser, J., Wolpaw, J. R., & Birbaumer, N. (2001) · Psychological Bulletin · doi:10.1037//0033-2909.127.3.358 · Cited by 553
Brain-Computer Interface—a new communication device for handicapped persons
Pfurtscheller, G., Flotzinger, D., & Kalcher, J. (1993) · Journal of Microcomputer Applications · doi:10.1006/jmca.1993.1030 · Cited by 502
The thought translation device (TTD) for completely paralyzed patients
Birbaumer, N., Kubler, A., Ghanayim, N., Hinterberger, T., Perelmouter, J., Kaiser, J., Iversen, I., Kotchoubey, B., Neumann, N., & Flor, H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847812 · Cited by 493
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Real-time detection of brain events in EEG
Vidal, J. J. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10542 · Cited by 457
Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy
Wyatt, J. S., Cope, M., Delpy, D. T., Richardson, C. E., Edwards, A. D., Wray, S., & Reynolds, E. O. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1086 · Cited by 442
The brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
Guest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
Noninvasive detection of changes in membrane potential in cultured neurons by light scattering.
Stepnoski, R. A., LaPorta, A., Raccuia-Behling, F., Blonder, G. E., Slusher, R. E., & Kleinfeld, D. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.21.9382 · Cited by 255
Noninvasive Functional Imaging of Human Brain Using Light
Benaron, D. A., Hintz, S. R., Villringer, A., Boas, D., Kleinschmidt, A., Frahm, J., Hirth, C., Obrig, H., van Houten, J. C., Kermit, E. L., et al. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200003000-00005 · Cited by 239
The Wadsworth Center brain-computer interface (BCI) research and development program
Wolpaw, J. R., McFarland, D. J., Vaughan, T. M., & Schalk, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814442 · Cited by 209
Mental representations of movements. Brain potentials associated with imagination of eye movements
Höllinger, P., Beisteiner, R., Lang, W., Lindinger, G., & Berthoz, A. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00042-x · Cited by 193
Shedding light on brain function: the event-related optical signal
Gratton, G., & Fabiani, M. (2001) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(00)01701-0 · Cited by 140
Kennan, R. P., Horovitz, S. G., Maki, A., Yamashita, Y., Koizumi, H., & Gore, J. C. (2002) · NeuroImage · doi:10.1006/nimg.2002.1060 · Cited by 121
Oscillations in Cerebral Haemodynamics
Elwell, C. E., Springett, R., Hillman, E. M. C., & Delpy, D. T. (1999) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-4717-4_8 · Cited by 112
Motor-cortical activity in tetraplegics
Shoham, S., Halgren, E., Maynard, E. M., & Normann, R. A. (2001) · Nature · doi:10.1038/35101651 · Cited by 99
Wolf, M. (2002) · NeuroImage · doi:10.1006/nimg.2002.1261 · Cited by 92
Oxygen Transport to Tissue XXI
Eke, A., & Delpy, D. T. (1999) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-4717-4 · Cited by 33
NIR spectroscopy measurements of cognitive load elicited by GKT and target categorization
İzzetoğlu, K., Yurtsever, G., Bozkurt, A. Y., Yazıcı, B., Bunce, S. C., Pourrezaei, K., & Onaral, B. (2003) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2003.1174296 · Cited by 23
Clinical application of fMRI: Motor cortex activation in a paralysed patient
Mao, H., Muthupillai, R., Kennedy, P. R., & Popp, C. A. (1998) · Cited by 2
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“Although NIRS is relatively new measurement modality, NIRS promises to be a potent neuroimaging modality for future applicability to BCIs [91,97].”
BackgroundfNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
“The first study who demonstrated the feasibility of fNIRS for BCI was Coyle et al. (2004).”
BackgroundInfluentialA quantitative comparison of NIRS and fMRI across multiple cognitive tasks
Cui, X., Bray, S., Bryant, D. M., Glover, G. H., & Reiss, A. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.069 · Cited by 945
Cui, X., Bryant, D. M., & Reiss, A. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.003 · Cited by 807
“, 2003), non-invasive brain-computer interfaces (Coyle et al., 2004; 2007; Power et al., 2010; Sitaram et al., 2007; Utsugi et al., 2008), and brain activity in both active tasks and resting states (Boecker et al.”
Breaking the silence: Brain-computer interfaces (BCI) for communication and motor control
Birbaumer, N. (2006) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00456.x · Cited by 722
“light in living tissues with high circulation density such as the brain, NIRS is completely noninvasive (Coyle et al., 2004).”
Background
Metadata
- Authors
- Coyle, S., Ward, T., Markham, C., & McDarby, G.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2004-07-23
- Volume
- 25
- Issue
- 4
- Pages
- 815-822
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2153566817
- Cited by
- 361
- References
- 30
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.