On the suitability of near-infrared (NIR) systems for next-generation brain–computer interfaces
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) gives those suffering from neuromuscular impairments a means to interact and communicate with their surrounding environment. A BCI translates physiological signals, typically electrical, detected from the brain to control an output device. A significant problem with current BCIs is the lengthy training periods involved for proficient usage, which can often lead to frustration and anxiety on the part of the user. Ultimately this can lead to abandonment of the device. The primary reason for this is that relatively indirect measures of cognitive function, as can be gleaned from the electroencephalogram (EEG), are harnessed. A more suitable and usable interface would need to measure cognitive function more directly. In order to do this, new measurement modalities, signal acquisition and processing, and translation algorithms need to be addressed. In this paper, we propose a novel approach, using non-invasive near-infrared imaging technology to develop a user-friendly optical BCI. As an alternative to the traditional EEG-based devices, we have used practical non-invasive optical techniques to detect characteristic haemodynamic responses due to motor imagery and consequently created an accessible BCI that is simple to attach and requires little user training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
Brain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685
Direct control of a computer from the human central nervous system
Kennedy, P. R., Bakay, R. A. E., Moore, M. M., Adams, K., & Goldwaithe, J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847815 · Cited by 573
Coupling of brain activity and cerebral blood flow: basis of functional neuroimaging.
Villringer, A., & Dirnagl, U. (1995) · PubMed · Cited by 566
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“Although NIRS is relatively new measurement modality, NIRS promises to be a potent neuroimaging modality for future applicability to BCIs [91,97].”
BackgroundfNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
“The first study who demonstrated the feasibility of fNIRS for BCI was Coyle et al. (2004).”
BackgroundInfluentialA quantitative comparison of NIRS and fMRI across multiple cognitive tasks
Cui, X., Bray, S., Bryant, D. M., Glover, G. H., & Reiss, A. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.069 · Cited by 945
Cui, X., Bryant, D. M., & Reiss, A. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.003 · Cited by 807
“, 2003), non-invasive brain-computer interfaces (Coyle et al., 2004; 2007; Power et al., 2010; Sitaram et al., 2007; Utsugi et al., 2008), and brain activity in both active tasks and resting states (Boecker et al.”
Breaking the silence: Brain-computer interfaces (BCI) for communication and motor control
Birbaumer, N. (2006) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00456.x · Cited by 722
“light in living tissues with high circulation density such as the brain, NIRS is completely noninvasive (Coyle et al., 2004).”
BackgroundBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Enhanced performance by a hybrid NIRS–EEG brain computer interface
Fazli, S., Mehnert, J., Steinbrink, J., Curio, G., Villringer, A., Müller, K.-R., & Blankertz, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.084 · Cited by 599
Sitaram, R., Zhang, H., Guan, C., Thulasidas, M., Hoshi, Y., Ishikawa, A., Shimizu, K., & Birbaumer, N. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.005 · Cited by 590
Rehabilitation of gait after stroke: a review towards a top-down approach
Belda-Lois, J.-M., Mena-del Horno, S., Bermejo-Bosch, I., Moreno, J. C., Pons, J. L., Farina, D., Iosa, M., Molinari, M., Tamburella, F., Ramos, A., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-66 · Cited by 581
Brain computer interface: control signals review
Ramadan, R. A., & Vasilakos, A. V. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.024 · Cited by 551
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Brain–computer interface using a simplified functional near-infrared spectroscopy system
Coyle, S. M., Ward, T. E., & Markham, C. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/007 · Cited by 505
Self-citationAn MEG-based brain–computer interface (BCI)
Mellinger, J., Schalk, G., Braun, C., Preissl, H., Rosenstiel, W., Birbaumer, N., & Kübler, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.03.019 · Cited by 445
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Brain-Computer Interfaces: Applying our Minds to Human-Computer Interaction
(2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8 · Cited by 393
Naseer, N., & Hong, K.-S. (2013) · Neuroscience Letters · doi:10.1016/j.neulet.2013.08.021 · Cited by 301
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Brain-Computer Interfacing for Intelligent Systems
Nijholt, A., & Tan, D. (2008) · IEEE Intelligent Systems · doi:10.1109/mis.2008.41 · Cited by 279
Classification of prefrontal and motor cortex signals for three-class fNIRS-BCI
Hong, K.-S., Naseer, N., & Kim, Y.-H. (2015) · Neuroscience Letters · doi:10.1016/j.neulet.2014.12.029 · Cited by 276
A Review of Hybrid Brain-Computer Interface Systems
Amiri, S., Fazel-Rezai, R., & Asadpour, V. (2013) · Advances in Human-Computer Interaction · doi:10.1155/2013/187024 · Cited by 209
“[4] introduced an approach of utilizing NIRS as an optical BCI.”
MethodAbdelnour, A. F., & Huppert, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.033 · Cited by 208
“…more standardized and traditional off-line analysis approaches for characterizing evoked hemodynamic signals (for example, see Friston, 2007), real-time brain imaging requires several modifications which have been discussed in (Coyle et al., 2004a,b; Matthews et al., 2008; Weiskopf et al., 2007).”
Backgroundvan Dokkum, L. E. H., Ward, T., & Laffont, I. (2015) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2014.09.016 · Cited by 195
Self-citationHemodynamic brain–computer interfaces for communication and rehabilitation
Sitaram, R., Caria, A., & Birbaumer, N. (2009) · Neural Networks · doi:10.1016/j.neunet.2009.05.009 · Cited by 189
Hybrid EEG-fNIRS Asynchronous Brain-Computer Interface for Multiple Motor Tasks
Buccino, A. P., Keles, H. O., & Omurtag, A. (2016) · PLOS ONE · doi:10.1371/journal.pone.0146610 · Cited by 183
Neuroscience-Based Lie Detection: The Urgent Need for Regulation
Greely, H. T., & Illes, J. (2007) · American Journal of Law & Medicine · doi:10.1177/009885880703300211 · Cited by 178
Multi-Modal Sensing Techniques for Interfacing Hand Prostheses: A Review
Fang, Y., Hettiarachchi, N., Zhou, D., & Liu, H. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2450211 · Cited by 172
“Conversely, NIRS-based BMIs are inexpensive and portable [107], [108], but no study reports that single modal NIRS can capture discriminative hand motion patterns yet.”
BackgroundReal-Time State Estimation in a Flight Simulator Using fNIRS
Gateau, T., Durantin, G., Lancelot, F., Scannella, S., & Dehais, F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0121279 · Cited by 167
“Altogether, these results are consistent with previous studies proving the potential of fNIRS for idle mode detection [26, 47].”
ResultQuality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation
Orihuela-Espina, F., Leff, D. R., James, D. R. C., Darzi, A. W., & Yang, G. Z. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/13/009 · Cited by 164
“Solutions incorporated into devices to reduce contamination by ambient light include the use of long pass filters (Cope and Delpy 1988), lock-in amplifiers (Coyle et al 2004), differential detection (Lee 2004) and embedding sensors in foam (Bozkurt et al 2005).”
BackgroundDecoding subjective preference from single-trial near-infrared spectroscopy signals
Luu, S., & Chau, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/016003 · Cited by 164
“In other studies there is no explicit removal of superficial and systemic influences from deep signals (Coyle et al 2004, 2007, Naito et al 2007).”
BackgroundBai, O., Lin, P., Vorbach, S., Floeter, M. K., Hattori, N., & Hallett, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/003 · Cited by 159
“…(Wolpaw and McFarland 1994), magnetoencephalography (MEG) (Kauhanen et al 2006), functional magnetic resonance imaging (fMRI) (Laconte et al 2006) or near-infrared signal (NIRS) (Coyle et al 2004, Sitaram et al 2007) and the invasive method of electrocorticography (ECoG) (Leuthardt et al 2006).”
MethodInfluentialPower, S. D., Falk, T. H., & Chau, T. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026002 · Cited by 158
“Initial studies involving able-bodied participants focused on the use of motor imagery as the paradigm of BCI control [19–21].”
BackgroundInfluentialNeuroimaging-based approaches in the brain–computer interface
Min, B.-K., Marzelli, M. J., & Yoo, S.-S. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.08.002 · Cited by 150
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Kwon, J., Shin, J., & Im, C.-H. (2020) · PLOS ONE · doi:10.1371/journal.pone.0230491 · Cited by 53
Brain activity measurement during program comprehension with NIRS
Ikutani, Y., & Uwano, H. (2014) · 15th IEEE/ACIS International Conference on Software Engineering, Artificial Intelligence, Networking and Parallel/Distributed Computing (SNPD) · doi:10.1109/snpd.2014.6888727 · Cited by 43
Metadata
- Authors
- Coyle, S., Ward, T., Markham, C., & McDarby, G.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2004-07-23
- Volume
- 25
- Issue
- 4
- Pages
- 815-822
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2153566817
- Cited by
- 361
- References
- 30
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.