Robust ballistocardiogram acquisition for home monitoring
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The ballistocardiogram (BCG) measures the reaction of the body to cardiac ejection forces, and is an effective, non-invasive means of evaluating cardiovascular function. A simple, robust method is presented for acquiring high-quality, repeatable BCG signals from a modified, commercially available scale. The measured BCG waveforms for all subjects qualitatively matched values in the existing literature and physiologic expectations in terms of timing and IJ amplitude. Additionally, the BCG IJ amplitude was shown to be correlated with diastolic filling time for a subject with premature atrial contractions, demonstrating the sensitivity of the apparatus to beat-by-beat hemodynamic changes. The signal-to-noise ratio (SNR) of the BCG was estimated using two methods, and the average SNR over all subjects was greater than 12 for both estimates. The BCG measurement was shown to be repeatable over 50 recordings taken from the same subject over a three week period. This approach could allow patients at home to monitor trends in cardiovascular health.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rosamond, W., Flegal, K., Friday, G., Furie, K., Go, A., Greenlund, K., Haase, N., Ho, M., Howard, V., Kissela, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.179918 · Cited by 3,277 · cited 1×
“Heart failure is a growing problem in the United States affecting over 5000 000 Americans and taking hundreds of thousands of lives each year (Rosamond et al 2007).”
BackgroundBioelectrical Signal Processing in Cardiac and Neurological Applications
(2005) · Elsevier eBooks · doi:10.1016/b978-0-12-437552-9.x5000-4 · Cited by 993 · cited 1×
“For more detail, the reader is referred to the literature (Sornmo and Laguna 2005).”
BackgroundStarr, I., Rawson, A. J., Schroeder, H. A., & Joseph, N. R. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.1 · Cited by 398 · cited 4×
“The amplitude and timing parameters of the BCG for all recordings were within the expected ranges for healthy subjects (Starr et al 1939, Deuchar et al 1955, Tannenbaum et al 1952).”
BackgroundInfluentialThe Management of Chronic Heart Failure
Cohn, J. N. (1996) · New England Journal of Medicine · doi:10.1056/nejm199608153350707 · Cited by 330
Certain Molar Movements of the Human Body produced by the Circulation of the Blood.
Jw, G. (1877) · Europe PMC (PubMed Central) · Cited by 197
Watanabe, M. A., Marine, J. E., Sheldon, R., & Josephson, M. E. (2002) · Circulation · doi:10.1161/01.cir.0000022163.24831.b5 · Cited by 103
(2002) · Journal of Cardiac Failure · doi:10.1016/s1071-9164(02)70013-4 · Cited by 97
Signal to noise ratio and response variability measurements in single trial evoked potentials
Coppola, R., Tabor, R., & Buchsbaum, M. S. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90267-5 · Cited by 96 · cited 2×
“For the maximum likelihood estimator of SNR, the following provides the SNR estimate for two distinct pairs of sub-ensemble averages (Coppola et al 1978): SNRML = 2 ∑N n=1 EAsub,1[n]EAsub,2[n]∑N n=1 (EAsub,1[n] − EAsub,2[n])2 (4) where EAsub,1 and EAsub,2 are the first and second sub-ensemble…”
BackgroundMethodSTARR, I., & WOOD, F. C. (1961) · Circulation · doi:10.1161/01.cir.23.5.714 · Cited by 84 · cited 1×
“Another longitudinal study confirmed that decreasing BCG IJ amplitude over time was an accurate sign of degrading cardiac health (Starr and Wood 1961).”
BackgroundSCARBOROUGH, W. R., Mason, R. E., Davis, F. W., SINGEWALD, M. L., Baker, B. M., & Lore, S. A. (1952) · American Heart Journal · doi:10.1016/0002-8703(52)90095-1 · Cited by 77
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“Although BCG provides a proximal waveform [106], [107], it can be applied at a distal location (e.g., from the feet with a weighing scale [104] or the wrist with an accelerometer [108]).”
BackgroundMethodBallistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
“atrial fibrillation [109], the observation of reduced signal amplitude in the setting of premature atrial or ventricular contractions [15], and the reduction of signal consistency in heart failure”
BackgroundInfluentialSelf-citationDetecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. (2013) · 2013 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2013.440 · Cited by 553
Wang, Z., Guan, X., Huang, H., Wang, H., Lin, W., & Peng, Z. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807569 · Cited by 247
Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
Bruser, C., Stadlthanner, K., de Waele, S., & Leonhardt, S. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2128337 · Cited by 219
“Weighing scales used in recent studies [10] also measure along this axis.”
BackgroundMethodBallistocardiogram signal processing: a review
Sadek, I., Biswas, J., & Abdulrazak, B. (2019) · Health Information Science and Systems · doi:10.1007/s13755-019-0071-7 · Cited by 216
“[61] collected ballistocardiogram signals using strain gauges within a modified commercial scale.”
MethodA Self‐Powered Sensor Mimicking Slow‐ and Fast‐Adapting Cutaneous Mechanoreceptors
Chun, K., Son, Y. J., Jeon, E., Lee, S., & Han, C. (2018) · Advanced Materials · doi:10.1002/adma.201706299 · Cited by 186
Ambient and Unobtrusive Cardiorespiratory Monitoring Techniques
Bruser, C., Antink, C. H., Wartzek, T., Walter, M., & Leonhardt, S. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2414661 · Cited by 175
“The use of load cells located under bed posts [34], [35] or as part of a weighing scale [36] has also been proposed.”
BackgroundMedical Smart Textiles Based on Fiber Optic Technology: An Overview
Massaroni, C., Saccomandi, P., & Schena, E. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6020204 · Cited by 172
“These sensors allow the measurement of physical and chemical parameters employing a large number of working principles and configurations [4].”
BackgroundBallistocardiography — A method worth revisiting
Giovangrandi, L., Inan, O. T., Wiard, R. M., Etemadi, M., & Kovacs, G. T. A. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091062 · Cited by 165
“While the BCGs of healthy people can be rather well interpreted in light of physiologic events, BCGs of patients with cardiovascular diseases tend to be more difficult to interpret because of the complex interplay of the various internal forces.”
MethodInfluentialSelf-citationCiocchetti, M., Massaroni, C., Saccomandi, P., Caponero, M., Polimadei, A., Formica, D., & Schena, E. (2015) · Biosensors · doi:10.3390/bios5030602 · Cited by 142
“For these applications, where subjects’ motion can cause artifact to the system signal, ad hoc algorithms to reduce the motion noise should be applied and the performances of the system may be assessed during subject motion as reported in other applications [32].”
MethodSimultaneous monitoring of ballistocardiogram and photoplethysmogram using a camera
Shao, D., Tsow, F., Liu, C., Yang, Y., & Tao, N. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2585109 · Cited by 69
A Ballistographic Approach for Continuous and Non-Obtrusive Monitoring of Movement in Neonates
Joshi, R., Bierling, B. L., Long, X., Weijers, J., Feijs, L., Van Pul, C., & Andriessen, P. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2875703 · Cited by 43
Metadata
- Authors
- Inan, O. T., Etemadi, M., Wiard, R. M., Giovangrandi, L., & Kovacs, G. T. A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2009-01-16
- Volume
- 30
- Issue
- 2
- Pages
- 169-185
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2078126533
- Cited by
- 234
- References
- 22
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.