Sleep stage classification with ECG and respiratory effort
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Automatic sleep stage classification with cardiorespiratory signals has attracted increasing attention. In contrast to the traditional manual scoring based on polysomnography, these signals can be measured using advanced unobtrusive techniques that are currently available, promising the application for personal and continuous home sleep monitoring. This paper describes a methodology for classifying wake, rapid-eye-movement (REM) sleep, and non-REM (NREM) light and deep sleep on a 30 s epoch basis. A total of 142 features were extracted from electrocardiogram and thoracic respiratory effort measured with respiratory inductance plethysmography. To improve the quality of these features, subject-specific Z-score normalization and spline smoothing were used to reduce between-subject and within-subject variability. A modified sequential forward selection feature selector procedure was applied, yielding 80 features while preventing the introduction of bias in the estimation of cross-validation performance. PSG data from 48 healthy adults were used to validate our methods. Using a linear discriminant classifier and a ten-fold cross-validation, we achieved a Cohen's kappa coefficient of 0.49 and an accuracy of 69% in the classification of wake, REM, light, and deep sleep. These values increased to kappa = 0.56 and accuracy = 80% when the classification problem was reduced to three classes, wake, REM sleep, and NREM sleep.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398 · cited 2×
“To select the final list of features we used a wrapper feature selection method based on sequential forward selection (SFS) (Whitney 1971) using as criterion the Cohen’s kappa coefficient of agreement κ (Cohen 1960) on the training set.”
BackgroundMethodThe Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research
Buysse, D. J., Reynolds, C. F., Monk, T. H., Berman, S. R., & Kupfer, D. J. (1989) · Psychiatry Research · doi:10.1016/0165-1781(89)90047-4 · Cited by 35,234
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · cited 2×
“We extracted a set of 142 features from cardiac and respiratory activity, and from cardiorespiratory interaction (CRI) using a sliding window centered on each 30 s epoch, guaranteeing sufficient data to capture the changes in autonomic activity (Malik et al 1996).”
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,675
de Boor, C. (1978) · Applied Mathematical Sciences · doi:10.1007/978-1-4612-6333-3 · Cited by 11,944
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880 · cited 2×
“…calculate these features (a window of 17 epochs corresponds, at an average heart rate of 60 bpm, to 510 samples), it has been suggested that the estimation of sample entropy is low in series shorter than 10m (where m is the pattern length, in samples) (Richman and Moorman 2000, Yentes et al 2013).”
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
Allan Hobson, J. (1969) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(69)90021-2 · Cited by 5,192
Principles and Practice of Sleep Medicine
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-59875-3 · Cited by 5,088
(1994) · Knowledge Discovery and Data Mining · Cited by 3,137
Floating search methods in feature selection
Pudil, P., Novovičová, J., & Kittler, J. (1994) · Pattern Recognition Letters · doi:10.1016/0167-8655(94)90127-9 · Cited by 3,098
Multiscale entropy analysis of biological signals
Costa, M., Goldberger, A. L., & Peng, C.-K. (2005) · Physical Review E · doi:10.1103/physreve.71.021906 · Cited by 2,482 · cited 1×
“…(Iyengar et al 1996, Penzel et al 2003), progressive DFA with non-overlapping segments of 64 heartbeats (Telser et al 2004), windowed DFA over 11 epochs (Adnane et al 2012), and multi-scale sample entropy (MSE) over 17 epochs (length of 1 and 2 samples with scales of 1–10) (Costa et al 2005).”
BackgroundFrom time series to complex networks: the visibility graph
Lacasa, L., Luque, B., Ballesteros, F., Luque, J., & Nuño, J. C. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0709247105 · Cited by 2,054 · cited 1×
“In addition, we propose new features based on a visibility graph (VG) and a difference VG (DVG) method to characterize HRV time series in a two-dimensional complex network where samples are connected as nodes in terms of certain criteria (Lacasa et al 2008, Long et al 2014a).”
MethodSleep-dependent memory consolidation
Stickgold, R. (2005) · Nature · doi:10.1038/nature04286 · Cited by 1,857 · cited 2×
“…important in several cortical and physiological processes, such as energy conservation (Berger and Phillips 1995), cerebral restoration (Benington and Heller 1995), and memory processing and consolidation (together with sleep spindles which occur during NREM stage 2) (Stickgold 2005, Walker 2009).”
BackgroundInfluentialSplines: a perfect fit for signal and image processing
Unser, M. (1999) · IEEE Signal Processing Magazine · doi:10.1109/79.799930 · Cited by 1,633 · cited 2×
“The smoothing function can be expressed by cubic B-splines as basis functions and determined via least squares approximation (Unser 1999, De Boor 2001).”
MethodInfluentialDetecting long-range correlations with detrended fluctuation analysis
Kantelhardt, J. W., Koscielny-Bunde, E., Rego, H. H. A., Havlin, S., & Bunde, A. (2001) · Physica A: Statistical Mechanics and its Applications · doi:10.1016/s0378-4371(01)00144-3 · Cited by 1,397
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142 · cited 1×
“QRS complexes were detected and localized from ECG signals using a combination of a Hamilton–Tompkins detector (Hamilton and Tompkins 1986, Hamilton 2002) and a post-processing localization algorithm (Fonseca et al 2014).”
MethodThe Appropriate Use of Approximate Entropy and Sample Entropy with Short Data Sets
Yentes, J. M., Hunt, N., Schmid, K. K., Kaipust, J. P., McGrath, D., & Stergiou, N. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0668-3 · Cited by 893
A Direct Method of Nonparametric Measurement Selection
Whitney, A. W. (1971) · IEEE Transactions on Computers · doi:10.1109/t-c.1971.223410 · Cited by 851 · cited 4×
“Hedner et al (2011) PAT, PO, ACT 227 OSA ± 49 14 0.48 0.66 Willemen et al (2014)c RIP, ECG, ACT 85 (36 subj.”
BackgroundResultInfluentialRestoration of brain energy metabolism as the function of sleep
Benington, J. H., & Craig Heller, H. (1995) · Progress in Neurobiology · doi:10.1016/0301-0082(94)00057-o · Cited by 825
Age-related alterations in the fractal scaling of cardiac interbeat interval dynamics
Iyengar, N., Peng, C. K., Morin, R., Goldberger, A. L., & Lipsitz, L. A. (1996) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1996.271.4.r1078 · Cited by 702
Penzel, T., Kantelhardt, J. W., Grote, L., Peter, J., & Bunde, A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.817636 · Cited by 492
Carskadon, M. A., & Dement, W. C. (2011) · Principles and Practice of Sleep Medicine · doi:10.1016/b978-1-4160-6645-3.00002-5 · Cited by 420
Zhu, G., Li, Y., & Wen, P. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2303991 · Cited by 384 · cited 1×
“…comprised the mean, SD, and slope of node degrees and number of nodes in VG- and DVG-based networks with a small degree (⩽3 for VG and ⩽2 for DVG) and a large degree (⩾10 for VG and ⩾8 for DVG), and assortativity coefficient in the VG-based network (Shao 2010, Long et al 2014a, Zhu et al 2014).”
BackgroundHamilton, P. (2003) · Computers in Cardiology · doi:10.1109/cic.2002.1166717 · Cited by 380 · cited 1×
“QRS complexes were detected and localized from ECG signals using a combination of a Hamilton–Tompkins detector (Hamilton and Tompkins 1986, Hamilton 2002) and a post-processing localization algorithm (Fonseca et al 2014).”
MethodBerger, R. J., & Phillips, N. H. (1995) · Behavioural Brain Research · doi:10.1016/0166-4328(95)00002-b · Cited by 256 · cited 1×
“…sleep since deep sleep is thought by some researchers to be important in several cortical and physiological processes, such as energy conservation (Berger and Phillips 1995), cerebral restoration (Benington and Heller 1995), and memory processing and consolidation (together with sleep spindles…”
BackgroundCardiorespiratory-Based Sleep Staging in Subjects With Obstructive Sleep Apnea
Redmond, S. J., & Heneghan, C. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869773 · Cited by 231
Spectral analysis of heart rate variability in sleep.
Bušek, P., Vaňková, J., Opavský, J., Salinger, J., & Nevšímalová, S. (2005) · Physiological Research · doi:10.33549/physiolres.930645 · Cited by 216 · cited 1×
“…spectral powers in the very low frequency band (VLF) from 0.003 to 0.04 Hz, in the low frequency band (LF) from 0.04 to 0.15 Hz, in the high frequency band (HF) between 0.15 to 0.4 Hz, and the LF-to-HF ratio (Busek et al 2005), where the power spectral densities were estimated over nine epochs.”
BackgroundInfluentialSleep Staging Based on Signals Acquired Through Bed Sensor
Kortelainen, J. M., Mendez, M. O., Bianchi, A. M., Matteucci, M., & Cerutti, S. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2044797 · Cited by 201
Pitfalls of supervised feature selection
Smialowski, P., Frishman, D., & Kramer, S. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btp621 · Cited by 197
The SIESTA project polygraphic and clinical database
Klosh, G., Kemp, B., Penzel, T., Schlogl, A., Rappelsberger, P., Trenker, E., Gruber, G., Zeithofer, J., Saletu, B., Herrmann, W. M., et al. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932725 · Cited by 187 · cited 1×
“A problem with traditional sleep monitoring, known as polysomnography (PSG), is that a wide array of potentially sleep-disturbing sensors must be applied to the body and their measurements can only be interpreted by highly trained sleep technicians or scientists.”
BackgroundSleep Staging Based on Autonomic Signals: A Multi-Center Validation Study
Hedner, J. A., White, D. P., Malhotra, A., Herscovici, S., Pittman, S. D., Zou, D., Grote, L., & Pillar, G. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1078 · Cited by 170
The Role of Slow Wave Sleep in Memory Processing.
Walker, M. P. (2009) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5.2s.s20 · Cited by 170
Sleep stages classification based on heart rate variability and random forest
Xiao, M., Yan, H., Song, J., Yang, Y., & Yang, X. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.06.001 · Cited by 165
Sleep stage and obstructive apneaic epoch classification using single-lead ECG
Yılmaz, B., Asyalı, M. H., Arıkan, E., Yetkin, S., & Özgen, F. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-39 · Cited by 157 · cited 1×
“%) of detrended and non-detrended heart rates and heartbeat intervals (Ylmaz et al 2010, Willemen et al 2014) as well as the mean, median, minimal, and maximal likelihood ratios of heart rates (Basner et al 2007).”
BackgroundNoncontact Method for Sleep Stage Estimation
Watanabe, T., & Watanabe, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.828037 · Cited by 149 · cited 4×
“More recent research has shown that it is possible to obtain the same cardiorespiratory information from other sensors for sleep stage classification, such as from bed-mounted ballistocardiogram (Watanabe and Watanabe 2004, Kortelainen et al 2010) or contactless radio frequency (de Chazal et al 2011). Although these s…”
BackgroundInfluentialSleep–wake stages classification and sleep efficiency estimation using single-lead electrocardiogram
Adnane, M., Jiang, Z., & Yan, Z. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.08.022 · Cited by 131 · cited 1×
“…(Iyengar et al 1996, Penzel et al 2003), progressive DFA with non-overlapping segments of 64 heartbeats (Telser et al 2004), windowed DFA over 11 epochs (Adnane et al 2012), and multi-scale sample entropy (MSE) over 17 epochs (length of 1 and 2 samples with scales of 1–10) (Costa et al 2005).”
BackgroundAn Evaluation of Cardiorespiratory and Movement Features With Respect to Sleep-Stage Classification
Willemen, T., Van Deun, D., Verhaert, V., Vandekerckhove, M., Exadaktylos, V., Verbraecken, J., Van Huffel, S., Haex, B., & Vander Sloten, J. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2276083 · Cited by 127 · cited 4×
“In addition, two studies with comparable results have been proposed by Domingues et al (2014) and Willemen et al (2014).”
BackgroundResultInfluentialSleep/wake measurement using a non-contact biomotion sensor
de Chazal, P., Fox, N. A., O’Hare, E., Heneghan, C., Zaffaroni, A., BOYLE, P., SMITH, S., O’CONNELL, C., & McNicholas, W. T. (2010) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2010.00876.x · Cited by 110 · cited 1×
“Approximate entropy of the symbolic binary sequence that encodes the increase or decrease in successive heartbeat intervals over nine epochs was also calculated (Cysarz et al 2000).”
BackgroundNetwork analysis of human heartbeat dynamics
Shao, Z.-G. (2010) · Applied Physics Letters · doi:10.1063/1.3308505 · Cited by 104 · cited 1×
“…comprised the mean, SD, and slope of node degrees and number of nodes in VG- and DVG-based networks with a small degree (⩽3 for VG and ⩽2 for DVG) and a large degree (⩾10 for VG and ⩾8 for DVG), and assortativity coefficient in the VG-based network (Shao 2010, Long et al 2014a, Zhu et al 2014).”
BackgroundSleep and Wake Classification With Actigraphy and Respiratory Effort Using Dynamic Warping
Long, X., Fonseca, P., Foussier, J., Haakma, R., & Aarts, R. M. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2284610 · Cited by 102
Self-citationSleep staging from Heart Rate Variability: time-varying spectral features and Hidden Markov Models
Mendez, M. O., Matteucci, M., Castronovo, V., Strambi, L. F., Cerutti, S., & Bianchi, A. M. (2010) · International Journal of Biomedical Engineering and Technology · doi:10.1504/ijbet.2010.032695 · Cited by 102
Entropies of short binary sequences in heart period dynamics
Cysarz, D., Bettermann, H., & van Leeuwen, P. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2163 · Cited by 100
Analyzing respiratory effort amplitude for automated sleep stage classification
Long, X., Foussier, J., Fonseca, P. M., Haakma, R., & Aarts, R. M. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.08.001 · Cited by 96
Self-citationSleep staging using cardiorespiratory signals
Redmond, S. J., de Chazal, P., O'Brien, C., Ryan, S., McNicholas, W. T., & Heneghan, C. (2007) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1007/s11818-007-0314-8 · Cited by 94 · cited 4×
“This work used a multi-class Bayesian linear discriminant with time-varying prior probabilities (Redmond et al 2007), similar to that used in previous work (Long et al 2014d).”
BackgroundMethodInfluentialSleep-Stage Decision Algorithm by Using Heartbeat and Body-Movement Signals
Kurihara, Y., & Watanabe, K. (2012) · IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans · doi:10.1109/tsmca.2012.2192264 · Cited by 71
Basner, M., Griefahn, B., Müller, U., Plath, G., & Samel, A. (2007) · Sleep · doi:10.1093/sleep/30.10.1349 · Cited by 58 · cited 1×
“%) of detrended and non-detrended heart rates and heartbeat intervals (Ylmaz et al 2010, Willemen et al 2014) as well as the mean, median, minimal, and maximal likelihood ratios of heart rates (Basner et al 2007).”
BackgroundAutomatic sleep staging based on ballistocardiographic signals recorded through bed sensors
Migliorini, M., Bianchi, A. M., Nistico, D., Kortelainen, J., Arce-Santana, E. R., Cerutti, S., & Mendez, M. O. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627217 · Cited by 58
Cysarz, D., Bettermann, H., Lange, S., Geue, D., & Leeuwen, P. V. (2004) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-3-44 · Cited by 54
Hypnogram and Sleep Parameter Computation From Activity and Cardiovascular Data
Domingues, A., Paiva, T., & Sanches, J. M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2301462 · Cited by 40
A novel low-complexity post-processing algorithm for precise QRS localization
Fonseca, P. M., Aarts, R. M., Foussier, J., & Long, X. (2014) · SpringerPlus · doi:10.1186/2193-1801-3-376 · Cited by 37 · cited 1×
“QRS complexes were detected and localized from ECG signals using a combination of a Hamilton–Tompkins detector (Hamilton and Tompkins 1986, Hamilton 2002) and a post-processing localization algorithm (Fonseca et al 2014).”
MethodSelf-citationSpectral Boundary Adaptation on Heart Rate Variability for Sleep and Wake Classification
Long, X., Fonseca, P. M., Haakma, R., Aarts, R. M., & Foussier, J. (2014) · International Journal of Artificial Intelligence Tools · doi:10.1142/s0218213014600021 · Cited by 37
Self-citationLong, X., Yang, J., Weysen, T., Haakma, R., Foussier, J., Fonseca, P., & Aarts, R. M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/12/2529 · Cited by 37 · cited 15×
“This work used a multi-class Bayesian linear discriminant with time-varying prior probabilities (Redmond et al 2007), similar to that used in previous work (Long et al 2014d).”
BackgroundMethodResultInfluentialSelf-citationTelser, S., Staudacher, M., Ploner, Y., Amann, A., Hinterhuber, H., & Ritsch‐Marte, M. (2004) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1111/j.1439-054x.2004.00016.x · Cited by 35 · cited 1×
“…(α2), and all time scaling exponents (Iyengar et al 1996, Penzel et al 2003), progressive DFA with non-overlapping segments of 64 heartbeats (Telser et al 2004), windowed DFA over 11 epochs (Adnane et al 2012), and multi-scale sample entropy (MSE) over 17 epochs (length of 1 and 2 samples…”
BackgroundComment on “Network analysis of human heartbeat dynamics” [Appl. Phys. Lett. 96, 073703 (2010)]
Zhao, D., & Li, X. (2010) · Applied Physics Letters · doi:10.1063/1.3458811 · Cited by 32
Modeling cardiorespiratory interaction during human sleep with complex networks
Long, X., Fonseca, P. M., Aarts, R. M., Haakma, R., & Foussier, J. (2014) · Applied Physics Letters · doi:10.1063/1.4902026 · Cited by 31
Self-citationEffect of sleep stage on the relationship between respiration and heart rate variability
Ichimaru, Y., Clark, K., Ringler, J., & Weiss, W. J. (2002) · Computers in cardiology · doi:10.1109/cic.1990.144305 · Cited by 16
Cited by
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Beattie, Z., Oyang, Y., Statan, A., Ghoreyshi, A., Pantelopoulos, A., Russell, A., & Heneghan, C. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa9047 · Cited by 198
Sleep stage classification from heart-rate variability using long short-term memory neural networks
Radha, M., Fonseca, P., Moreau, A., Ross, M., Cerny, A., Anderer, P., Long, X., & Aarts, R. M. (2019) · Scientific Reports · doi:10.1038/s41598-019-49703-y · Cited by 186
“Bi-directional multi-level LSTM networks34 are temporal models that could potentially overcome all the limitations outlined in the last subsection, because they (1) can model temporal context unlike feed-forward approaches17, (2) have a large temporal scope unlike Markovian models such as conditional random fields31,…”
MethodSelf-citationA review of automated sleep stage scoring based on physiological signals for the new millennia
Faust, O., Razaghi, H., Barika, R., Ciaccio, E. J., & Acharya, U. R. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.04.032 · Cited by 170
“, 2015 [110] Data from 48 subjects ECG: Spectral power, variability measurements, and network analysis.”
BackgroundFonseca, P., Weysen, T., Goelema, M. S., Møst, E. I. S., Radha, M., Lunsingh Scheurleer, C., van den Heuvel, L., & Aarts, R. M. (2017) · SLEEP · doi:10.1093/sleep/zsx097 · Cited by 148
Self-citation
Metadata
- Authors
- Fonseca, P., Long, X., Radha, M., Haakma, R., Aarts, R. M., & Rolink, J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2015-08-19
- Volume
- 36
- Issue
- 10
- Pages
- 2027-2040
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1638975642
- Cited by
- 168
- References
- 58
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.