A 20-channel magnetoencephalography system based on optically pumped magnetometers
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
We describe a multichannel magnetoencephalography (MEG) system that uses optically pumped magnetometers (OPMs) to sense the magnetic fields of the human brain. The system consists of an array of 20 OPM channels conforming to the human subject's head, a person-sized magnetic shield containing the array and the human subject, a laser system to drive the OPM array, and various control and data acquisition systems. We conducted two MEG experiments: auditory evoked magnetic field and somatosensory evoked magnetic field, on three healthy male subjects, using both our OPM array and a 306-channel Elekta-Neuromag superconducting quantum interference device (SQUID) MEG system. The described OPM array measures the tangential components of the magnetic field as opposed to the radial component measured by most SQUID-based MEG systems. Herein, we compare the results of the OPM- and SQUID-based MEG systems on the auditory and somatosensory data recorded in the same individuals on both systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328 · cited 1×
“Both OPM and SQUID sensor reveal similar time-frequency spectra as shown in figure 11 c-d; it is worth noticing that the beta suppression [34, 35] is observed with both SQUID and OPM”
MethodHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 2×
“In the OPM data a large 100 ms component, which was experimentally determined to be stemming from the left somatosensory cortex S2 in References [2, 33], was observed in all three subjects (see figure 8a) with a magnitude of greater than 5 pT.”
BackgroundMethodA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“er beams travel collinearly through the sensor. The scheme is an extension of an OPM using elliptically polarized light [12], and operates in the so-called spin-exchange relaxation-free (SERF) regime [22]. In the SERF regime, the OPM is operated at a high density of the rubidium vapor and near zero magnetic field— und…”
Independent component approach to the analysis of EEG and MEG recordings
Vigario, R., Sarela, J., Jousmiki, V., Hamalainen, M., & Oja, E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841330 · Cited by 796 · cited 10×
“Independent component analysis (ICA) [29, 30] is run on the selected continuous block of data, and the noise components, e.”
MethodInfluentialMagnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441 · cited 1×
“MEG with an OPM system was first demonstrated by the Romalis group [6, 7].”
MethodA compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322 · cited 2×
“More recent OPM development for MEG has focused on modular designs [7-9] where light is brought to the OPM either via fiber optics [10-13] or by incorporating a laser into the OPM module allowing flexible placement of the OPM [14].”
MethodMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296 · cited 1×
“Two recent simulation studies also demonstrate the distinct advantages of moving the sensors closer to the brain [4, 5].”
Background
Cited by
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
“Whilst multi-channel systems are available (e.g. (Borna et al., 2017; Boto et al., 2018; Iivanainen et al., 2019b)), most demonstrations still employ small numbers of sensors sited over specific brain regions and the introduction of a whole-head array will be an important step forward.”
BackgroundOn-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Holmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250
IFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)
Hari, R., Baillet, S., Barnes, G., Burgess, R., Forss, N., Gross, J., Hämäläinen, M., Jensen, O., Kakigi, R., Mauguière, F., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.042 · Cited by 167
“Several well-known MEG signals, such as the spontaneous alpha rhythm and auditory and somatosensory evoked fields, have been used as physiological test signals demonstrating the feasibility of these new devices (Borna et al., 2017; Boto et al., 2017).”
MethodHolmes, N., Tierney, T. M., Leggett, J., Boto, E., Mellor, S., Roberts, G., Hill, R. M., Shah, V., Barnes, G. R., Brookes, M. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-50697-w · Cited by 163
“ r b twoDFT i k S k k e k z ( ) ( ( , ) cosh( )) , (4) i xj x j x y k a r i x y 0 , r”
BackgroundNon-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158
“Our instrumentation and data analysis pipeline are improved over our prior work presented in [14].”
BackgroundMethodInfluentialSelf-citationCan EEG and MEG detect signals from the human cerebellum?
Andersen, L. M., Jerbi, K., & Dalal, S. S. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116817 · Cited by 142
Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116099 · Cited by 136
Strand, S., Lutter, W., Strasburger, J. F., Shah, V., Baffa, O., & Wakai, R. T. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.119.013436 · Cited by 136
“Open-ended shields have been used previously for magnetoencephalography.(13,14) In those studies, however, subjects entered the shield head first so that the sensors were situated near the closed end, where the shielding performance is A”
MethodTowards OPM-MEG in a Virtual Reality Environment
Roberts, G., Holmes, N., Alexander, N., Boto, E., Leggett, J., Hill, R. M., Shah, V., Rea, M., Vaughan, R., Maguire, E. A., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.010 · Cited by 128
“A number of studies have demonstrated the applicability of OPMs in MEG (Borna et al., 2017; Boto et al., 2018; Johnson et al., 2013; Kamada et al., 2015) and recent developments have seen the introduction of small (Sander et al., 2012) and lightweight commercial OPMs (Osborne et al., 2018), which…”
BackgroundBorna, A., Iivanainen, J., Carter, T. R., McKay, J., Taulu, S., Stephen, J., & Schwindt, P. D. D. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2021.118818 · Cited by 120
“In our SEF experiments Borna et al., 2017 ), shown in Fig.”
Self-citationA 90-Channel Triaxial Magnetoencephalography System Using Optically Pumped Magnetometers
Rea, M., Boto, E., Holmes, N., Hill, R., Osborne, J., Rhodes, N., Leggett, J., Rier, L., Bowtell, R., Shah, V., et al. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14890 · Cited by 102
Using OPMs to measure neural activity in standing, mobile participants
Seymour, R. A., Alexander, N., Mellor, S., O'Neill, G. C., Tierney, T. M., Barnes, G. R., & Maguire, E. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118604 · Cited by 102
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
Jensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-34535-z · Cited by 79
Four-channel optically pumped magnetometer for a magnetoencephalography sensor array
Iivanainen, J., Carter, T. R., Dhombridge, J. E., Read, T. S., Campbell, K., Abate, Q., Ridley, D. M., Borna, A., & Schwindt, P. D. D. (2024) · Optics Express · doi:10.1364/oe.517961 · Cited by 18
“[40]).”
Self-citation
Metadata
- Authors
- Borna, A., Carter, T. R., Goldberg, J. D., Colombo, A. P., Jau, Y.-Y., Berry, C., McKay, J., Stephen, J., Weisend, M., & Schwindt, P. D. D.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2017-11-10
- Volume
- 62
- Issue
- 23
- Pages
- 8909-8923
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2643001131
- Cited by
- 173
- References
- 31
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.