Advanced Monte Carlo simulations of emission tomography imaging systems with GATE
Open accessThe DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Abstract
Built on top of the Geant4 toolkit, GATE is collaboratively developed for more than 15 years to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular, used by researchers and industrials to design, optimize, understand and create innovative emission tomography systems. In this paper, we reviewed the recent developments that have been proposed to simulate modern detectors and provide a comprehensive report on imaging systems that have been simulated and evaluated in GATE. Additionally, some methodological developments that are not specific for imaging but that can improve detector modeling and provide computation time gains, such as Variance Reduction Techniques and Artificial Intelligence integration, are described and discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matplotlib: a 2D graphics environment
Hunter, J. D. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.55 · Cited by 39,249 · cited 1×
“Python has become the tool of choice for data analysis withmodules such asNumPy (Harris et al 2020) orMatplotlib (Hunter 2007).”
MethodPyTorch: An Imperative Style, High-Performance Deep Learning Library
Paszke, A., Gross, S., Massa, F., Lerer, A., Bradbury, J., Chanan, G., Killeen, T., Lin, Z., Gimelshein, N., Antiga, L., et al. (2019) · arXiv · doi:10.48550/arxiv.1912.01703 · Cited by 31,473
Harris, C. R., Millman, K. J., van der Walt, S. J., Gommers, R., Virtanen, P., Cournapeau, D., Wieser, E., Taylor, J., Berg, S., Smith, N. J., et al. (2020) · Nature · doi:10.1038/s41586-020-2649-2 · Cited by 23,826 · cited 2×
“Since version 9.0, GATEnow includes additional options to read/write data inNPYfile format (Harris et al 2020) that can be processedwith Python.”
MethodInfluentialLabaca-Castro, R. (2023) · Machine Learning under Malware Attack · doi:10.1007/978-3-658-40442-0_9 · Cited by 19,272
Harris, C., Millman, K., van der Walt, S., Gommers, R., Virtanen, P., Cournapeau, D., Wieser, E., Taylor, J., Berg, S., Smith, N., et al. (2020) · RePEc: Research Papers in Economics · Cited by 17,844
ROOT — An object oriented data analysis framework
Brun, R., & Rademakers, F. (1997) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(97)00048-x · Cited by 4,919
Allison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., Bagli, E., Bagulya, A., Banerjee, S., Barrand, G., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.06.125 · Cited by 4,194
GATE: a simulation toolkit for PET and SPECT
Jan, S., Santin, G., Strul, D., Staelens, S. G., Assié, K., Autret, D., Avner, S., Barbier, R., Bardiès, M., Bloomfield, P. M., et al. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/19/007 · Cited by 2,475
Self-citationJan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/001 · Cited by 794
Self-citationSarrut, D., Bardiès, M., Boussion, N., Freud, N., Jan, S., Létang, J.-M., Loudos, G., Maigne, L., Marcatili, S., Mauxion, T., et al. (2014) · Medical Physics · doi:10.1118/1.4871617 · Cited by 573
Self-citationSTIR: software for tomographic image reconstruction release 2
Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., & Jacobson, M. W. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/867 · Cited by 466
(2012) · Elsevier eBooks · doi:10.1016/c2009-0-51635-2 · Cited by 459
State of the art in total body PET
Vandenberghe, S., Moskal, P., & Karp, J. S. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00290-2 · Cited by 390
Self-citationRecent developments in PET detector technology
Lewellen, T. K. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/r01 · Cited by 336 · cited 1×
“The increasing use of SiPMs (see section 2) in the context of PET imaging (Lewellen 2008, Cabello andZiegler 2018, Conti and Bendriem 2019)motivated the implementation of specific digitizermodules for analog and digital SiPMs (dSiPMs), so that both the complete scanner system and the single…”
BackgroundNguyen, D., Jia, X., Sher, D., Lin, M.-H., Iqbal, Z., Liu, H., & Jiang, S. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab039b · Cited by 318
The digital silicon photomultiplier — Principle of operation and intrinsic detector performance
Frach, T., Prescher, G., Degenhardt, C., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009) · 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) · doi:10.1109/nssmic.2009.5402143 · Cited by 317
Pushing the Limits in Time-of-Flight PET Imaging
Lecoq, P. (2017) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2017.2756674 · Cited by 302 · cited 1×
“The potential of Cerenkov light has become the foundation of a paradigm shift in TOFPET,with initiatives such as the 10 ps TOF challenge (Lecoq 2017, Schaart et al 2020, Lecoq et al 2020).”
BackgroundRoadmap toward the 10 ps time-of-flight PET challenge
Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab9500 · Cited by 258
Self-citationApplication of Silicon Photomultipliers to Positron Emission Tomography
Roncali, E., & Cherry, S. R. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0266-9 · Cited by 239
Self-citationFeasibility study of the positronium imaging with the J-PET tomograph
Moskal, P., Kisielewska, D., Curceanu, C., Czerwiński, E., Dulski, K., Gajos, A., Gorgol, M., Hiesmayr, B. C., Jasińska, B., Kacprzak, K., et al. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aafe20 · Cited by 238
Self-citationMerlin, T., Stute, S., Benoit, D., Bert, J., Carlier, T., Comtat, C., Filipovic, M., Lamare, F., & Visvikis, D. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aadac1 · Cited by 236
Self-citationA Roadmap for HEP Software and Computing R&D for the 2020s
The HEP Software Foundation, Albrecht, J., Alves, A. A., Amadio, G., Andronico, G., Anh-Ky, N., Aphecetche, L., Apostolakis, J., Asai, M., Atzori, L., et al. (2019) · Computing and Software for Big Science · doi:10.1007/s41781-018-0018-8 · Cited by 234
Rit, S., Vila Oliva, M., Brousmiche, S., Labarbe, R., Sarrut, D., & Sharp, G. C. (2014) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/489/1/012079 · Cited by 234
Self-citationDeep Learning for PET Image Reconstruction
Reader, A. J., Corda, G., Mehranian, A., Costa-Luis, C. D., Ellis, S., & Schnabel, J. A. (2021) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.3014786 · Cited by 228
GATE (geant4 application for tomographic emission): a PET/SPECT general-purpose simulation platform
Strulab, D., Santin, G., Lazaro, D., Breton, V., & Morel, C. (2003) · Nuclear Physics B - Proceedings Supplements · doi:10.1016/s0920-5632(03)90969-8 · Cited by 208
Self-citationThe new opportunities for high time resolution clinical TOF PET
Conti, M., & Bendriem, B. (2019) · Clinical and Translational Imaging · doi:10.1007/s40336-019-00316-5 · Cited by 180
BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET
Brünner, S., & Schaart, D. R. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6a49 · Cited by 173
The digital Silicon Photomultiplier — A novel sensor for the detection of scintillation light
Dege, C., Prescher, G., Frach, T., Thon, A., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009) · 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) · doi:10.1109/nssmic.2009.5402190 · Cited by 169
Prospects and Clinical Perspectives of Total-Body PET Imaging Using Plastic Scintillators
Moskal, P., & Stępień, E. Ł. (2020) · PET Clinics · doi:10.1016/j.cpet.2020.06.009 · Cited by 166
Lee, M. S., Hwang, D., Kim, J. H., & Lee, J. S. (2019) · Scientific Reports · doi:10.1038/s41598-019-46620-y · Cited by 147
Performance of the new generation of whole-body PET/CT scanners: Discovery STE and Discovery VCT
Teräs, M., Tolvanen, T., Johansson, J. J., Williams, J. J., & Knuuti, J. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0493-3 · Cited by 146
The first MICCAI challenge on PET tumor segmentation
Hatt, M., Laurent, B., Ouahabi, A., Fayad, H., Tan, S., Li, L., Lu, W., Jaouen, V., Tauber, C., Czakon, J., et al. (2018) · Medical Image Analysis · doi:10.1016/j.media.2017.12.007 · Cited by 137
Self-citationLee, J. S. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.3009269 · Cited by 132
Poon, J. K., Dahlbom, M. L., Moses, W. W., Balakrishnan, K., Wang, W., Cherry, S. R., & Badawi, R. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/13/4077 · Cited by 129
Lehner, C. E., He, Z. J., & Zhang, F. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.832573 · Cited by 125
A deep learning method for prediction of three‐dimensional dose distribution of helical tomotherapy
Liu, Z., Fan, J., Li, M., Yan, H., Hu, Z., Huang, P., Tian, Y., Miao, J., & Dai, J. (2019) · Medical Physics · doi:10.1002/mp.13490 · Cited by 123
Cates, J. W., Gundacker, S., Auffray, E., Lecoq, P. R., & Levin, C. S. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aadbcd · Cited by 123
The physics of radioembolization
Bastiaannet, R., Kappadath, S. C., Kunnen, B., Braat, A. J. A. T., Lam, M. G. E. H., & de Jong, H. W. A. M. (2018) · EJNMMI Physics · doi:10.1186/s40658-018-0221-z · Cited by 122
Geant4-based Monte Carlo simulations on GPU for medical applications
Bert, J., Pérez-Ponce, H., Bitar, Z. E., Jan, S., Boursier, Y., Vintache, D., Bonissent, A., Morel, C., Brasse, D., & Visvikis, D. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5593 · Cited by 116
Self-citationPapadimitroulas, P., Loudos, G. K., Nikiforidis, G. C., & Kagadis, G. C. (2012) · Medical Physics · doi:10.1118/1.4737096 · Cited by 115
Self-citationOpenDose: Open-Access Resource for Nuclear Medicine Dosimetry
Chauvin, M., Borys, D., Botta, F., Bzowski, P., Dabin, J., Denis-Bacelar, A. M., Desbrée, A., Falzone, N., Lee, B. Q., Mairani, A., et al. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.240366 · Cited by 108
Self-citationUsing convolutional neural networks to estimate time-of-flight from PET detector waveforms
Berg, E., & Cherry, S. R. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa9dc5 · Cited by 108
Lazaro, D., Buvat, I., Loudos, G. K., Strul, D., Santin, G., Giokaris, N., Donnarieix, D., Maigne, L., Spanoudaki, V. C., Styliaris, S., et al. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/2/007 · Cited by 103
Self-citationBismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET
Kwon, S. I., Gola, A. G., Ferri, A., Piemonte, C., & Cherry, S. R. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/l38 · Cited by 94
Fast reconstruction of 3D time-of-flight PET data by axial rebinning and transverse mashing
Vandenberghe, S., Daube-Witherspoon, M. E., Lewitt, R. M., & Karp, J. S. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/6/017 · Cited by 87
Self-citationOxygen sensing ability of positronium atom for tumor hypoxia imaging
Shibuya, K., Saito, H., Nishikido, F., Takahashi, M., & Yamaya, T. (2020) · Communications Physics · doi:10.1038/s42005-020-00440-z · Cited by 85
Artificial Intelligence in Radiation Therapy
Fu, Y., Zhang, H., Morris, E. D., Glide‐Hurst, C. K., Pai, S., Traverso, A., Wee, L., Hadžić, I., Lønne, P.-I., Shen, C., et al. (2021) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2021.3107454 · Cited by 83
Muller, F., Schug, D., Hallen, P., Grahe, J., & Schulz, V. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2884320 · Cited by 83
A deep learning approach to radiation dose estimation
Götz, T., Schmidkonz, C., Chen, S., Al-Baddai, S., Kuwert, T., & Lang, E. W. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab65dc · Cited by 82
The Future of Nuclear Medicine as an Independent Specialty
Czernin, J. G., Sonni, I., Razmaria, A. A., & Calais, J. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.220558 · Cited by 81
Lalonde, A., Winey, B. A., Verburg, J., Paganetti, H., & Sharp, G. C. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab9fcb · Cited by 80
Song, X., Segars, W. P., Du, Y., Tsui, B. M. W., & Frey, E. C. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/8/011 · Cited by 80
Muller, F., Schug, D., Hallen, P., Grahe, J., & Schulz, V. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2837738 · Cited by 78
TMARKER: A free software toolkit for histopathological cell counting and staining estimation
Schüffler, P. J., Fuchs, T. J., Ong, C. S., Wild, P. J., Rupp, N. J., & Buhmann, J. M. (2013) · Journal of Pathology Informatics · doi:10.4103/2153-3539.109804 · Cited by 75
Estimating the NEMA characteristics of the J-PET tomograph using the GATE package
Kowalski, P., Wiślicki, W., Shopa, R. Y., Raczyński, L., Klimaszewski, K., Curcenau, C., Czerwiński, E., Dulski, K., Gajos, A., Gorgol, M., et al. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aad29b · Cited by 74
Self-citationMachine learning-based patient specific prompt-gamma dose monitoring in proton therapy
Gueth, P., Dauvergne, D., Freud, N., Létang, J. M., Ray, C. D., Testa, É., & Sarrut, D. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/13/4563 · Cited by 72
Self-citationMuller, F., Schug, D., Hallen, P., Grahe, J., & Schulz, V. (2019) · RWTH Publications (RWTH Aachen) · Cited by 71
Advances in PET/MR instrumentation and image reconstruction
Cabello, J., & Ziegler, S. I. (2016) · British Journal of Radiology · doi:10.1259/bjr.20160363 · Cited by 64
Scheins, J. J., Herzog, H. R., & Shah, N. J. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2109732 · Cited by 63
Dual-ended readout of bismuth germanate to improve timing resolution in time-of-flight PET
Kwon, S. I., Roncali, E., Gola, A. G., Paternoster, G., Piemonte, C., & Cherry, S. R. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab18da · Cited by 58
Self-citationRoncali, E., Taebi, A., Foster, C. C., & Vu, C. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02469-1 · Cited by 55
Self-citationTRIMAGE: A dedicated trimodality (PET/MR/EEG) imaging tool for schizophrenia
Guerra, A. D., Ahmad, S., Avram, M., Belcari, N., Berneking, A., Biagi, L., Bisogni, M. G., Brandl, F., Cabello, J., Camarlinghi, N., et al. (2018) · European Psychiatry · doi:10.1016/j.eurpsy.2017.11.007 · Cited by 51
Self-citationGrevillot, L., Boersma, D. J., Fuchs, H., Aitkenhead, A. H., Elia, A., Bolsa-Ferruz, M., Winterhalter, C., Vidal, M., Jan, S., Pietrzyk, U., et al. (2020) · Medical Physics · doi:10.1002/mp.14242 · Cited by 48
Self-citationStudy of Čerenkov Light Emission in the Semiconductors TlBr and TlCl for TOF-PET
Ariño‐Estrada, G., Roncali, E., Selfridge, A. R., Du, J., Glodo, J., Shah, K. S., & Cherry, S. R. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.3024032 · Cited by 46
Self-citationGenerative adversarial networks (GAN) for compact beam source modelling in Monte Carlo simulations
Sarrut, D., Krah, N., & Létang, J. M. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab3fc1 · Cited by 44
Self-citationEnsemble of neural networks for 3D position estimation in monolithic PET detectors
Iborra, A., González, A. J., González-Montoro, A., Bousse, A., & Visvikis, D. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab3b86 · Cited by 44
Self-citationMonte Carlo simulation of digital photon counting PET
Salvadori, J., Labour, J., Odille, F., Marie, P., Badel, J., Imbert, L., & Sarrut, D. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00288-w · Cited by 42 · cited 1×
“In Salvadori (2020), a detailedmodel of theVereosTMDPC-PETwas proposed.”
BackgroundSelf-citationExtending the Hybrid Surgical Guidance Concept With Freehand Fluorescence Tomography
van Oosterom, M. N., van der Poel, H. G., van Leeuwen, F. W. B., Meershoek, P., Welling, M. M., Pinto, F., Matthies, P., Simon, H., Wendler, T., Navab, N., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2924254 · Cited by 41
Artificial neural networks for positioning of gamma interactions in monolithic PET detectors
Decuyper, M., Stockhoff, M., Vandenberghe, S., & Holen, R. V. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abebfc · Cited by 37
Self-citationHilaire, E., Sarrut, D., Peyrin, F., & Maxim, V. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/8/3127 · Cited by 36
Self-citationFanchon, L. M., Doğan, S., Moreira, A. L., Carlin, S., Schmidtlein, C. R., Yorke, E. D., Apte, A., Burger, I. A., Durack, J. C., Erinjeri, J. P., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.148668 · Cited by 35
CCMod: a GATE module for Compton camera imaging simulation
Etxebeste, A., Dauvergne, D., Fontana, M., Létang, J. M., Llosa, G., Muñoz, E., Oliver, J., Testa, É., & Sarrut, D. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab6529 · Cited by 31
Self-citationSarrut, D., Etxebeste, A., Krah, N., & Létang, J. M. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abde9a · Cited by 31
Self-citationOptical simulation study on the spatial resolution of a thick monolithic PET detector
Stockhoff, M., Holen, R. V., & Vandenberghe, S. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab3b83 · Cited by 30
Self-citationRedesign of the GATE PET coincidence sorter
Strydhorst, J. H., & Buvat, I. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/n522 · Cited by 27
Conde, P., Iborra, A., González, A. J., Hernández, L., Bellido, P., Moliner, L., Rigla, J. P., Rodríguez-Álvarez, M. J., Sánchez, F., Seimetz, M., et al. (2016) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2016.2515163 · Cited by 26
Mitigating inherent noise in Monte Carlo dose distributions using dilated U‐Net
Javaid, U., Souris, K., Dasnoy, D., Huang, S., & Lee, J. A. (2019) · Medical Physics · doi:10.1002/mp.13856 · Cited by 25
Monte-Carlo simulations and image reconstruction for novel imaging scenarios in emission tomography
Gillam, J. E., & Rafecas, M. (2015) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2015.09.084 · Cited by 25
Self-citationImplementation of cylindrical PET scanners with block detector geometry in STIR
Khateri, P., Fischer, J., Lustermann, W., Tsoumpas, C., & Dissertori, G. (2019) · EJNMMI Physics · doi:10.1186/s40658-019-0248-9 · Cited by 24
Γεωργίου, Μ., Fysikopoulos, E., Konstantinos, M., Fragogeorgi, E. A., & Loudos, G. K. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-1011-4 · Cited by 23
Self-citationJan, S., Frisson, T., & Sarrut, D. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2012.2233496 · Cited by 21
Self-citationvan der Heyden, B., Uray, M., Fonseca, G. P., Huber, P., Us, D., Messner, I., Law, A., Parii, A., Reisz, N., Rinaldi, I., et al. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab8954 · Cited by 20
Yvon, D., Shary, V., Follin, M., Bard, J.-P., Breton, D., Maalmi, J., Morel, C., & Delagnes, E. (2020) · Journal of Instrumentation · doi:10.1088/1748-0221/15/07/p07029 · Cited by 19
Self-citationPeng, Z. M., Shan, H., Liu, T., Pei, X., Zhou, J., Wang, G., & Xu, X. G. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1910.07735 · Cited by 18
A gate evaluation of the sources of error in quantitative90Y PET
Strydhorst, J. H., Carlier, T., Dieudonné, A., Conti, M., & Buvat, I. (2016) · Medical Physics · doi:10.1118/1.4961747 · Cited by 17
Geramifar, P., Ay, M. R., Zafarghandi, M. S., Sarkar, S., Loudos, G. K., & Rahmim, A. (2011) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2011.03.030 · Cited by 14
Self-citationLee, Y. S., Kim, J. S., Kim, K. M., Lim, S. M., & Kim, H.-J. (2015) · Journal of Instrumentation · doi:10.1088/1748-0221/10/01/p01004 · Cited by 14
Sarrut, D., Krah, N., Badel, J., et al. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aae331 · Cited by 11
Self-citationNeph, R., Huang, Y., Yang, Y., et al. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32486-5_17 · Cited by 10
3-D Reconstruction Benchmark of a Compton Camera Against a Parallel-Hole Gamma Camera on Ideal Data
Feng, Y., Etxebeste, A., Sarrut, D., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2019.2955745 · Cited by 10
Self-citationKirov, A. S., Fanchon, L. M., Seiter, D., Czmielewski, C., Russell, J., Doğan, S., Carlin, S., Pinker, K., Yorke, E. D., Schmidtlein, C. R., et al. (2018) · Medical Physics · doi:10.1002/mp.12836 · Cited by 9
Self-citationXu, H., Lenz, M., Caldeira, L., Ma, B., Pietrzyk, U., Lerche, C. W., Shah, N. J., & Scheins, J. J. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab266b · Cited by 7
Self-citationTotal‐body PET is ready for prime time
Surti, S., Guerra, A. D., & Zaidi, H. (2020) · Medical Physics · doi:10.1002/mp.14520 · Cited by 3
Metadata
- Authors
- Sarrut, D., Bała, M., Bardiès, M., Bert, J., Chauvin, M., Chatzipapas, K., Dupont, M., Etxebeste, A., M Fanchon, L., Jan, S., Kayal, G., S Kirov, A., Kowalski, P., Krzemien, W., Labour, J., Lenz, M., Loudos, G., Mehadji, B., Ménard, L., Morel, C., Papadimitroulas, P., Rafecas, M., Salvadori, J., Seiter, D., Stockhoff, M., Testa, E., Trigila, C., Pietrzyk, U., Vandenberghe, S., Verdier, M.-A., Visvikis, D., Ziemons, K., Zvolský, M., & Roncali, E.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2021-05-14
- Volume
- 66
- Issue
- 10
- Pages
- 10TR03
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W3137889704
- Cited by
- 204
- References
- 93
- FWCI
- 17.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.