CoChat

An accurate and robust metrological network for coherent optical frequency dissemination

Open access
Cantin, Etienne, Tønnes, Mads, Le Targat, Rodolphe, Amy-Klein, Anne, Lopez, Olivier, Pottie, Paul-Eric · 2021 · New Journal of Physics

The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index.

Abstract

We introduce multi-branch repeater laser stations (MLSs) for the dissemination of an ultra-stable signal from one point to multiple users and the simultaneous evaluation of the stability and accuracy of multiple links. We perform the study of the noise floor of this new instrument. We present then an optical fiber network of 4800 km built with three MLSs and 13 repeater laser stations (RLSs). We show the multi-user optical frequency dissemination on four links totalizing 2198 km with uncertainties below 1.1 × 10 −19 . The robustness of the network over two years is presented and stability and accuracy at 10 7 seconds integration time are finally showed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1367-2630/abe79e

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 (a) REFIMEVE + metrological network in France with laboratories currently benefiting from the signal. (b) Sketch of the network architecture, MLS: multi-branch laser station, RLS: repeater laser station, bEDFA: bidirectional erbium doped fiber amplifier, U: user.
Figure 1 (a) REFIMEVE + metrological network in France with laboratories currently benefiting from the signal. (b) Sketch of the network architecture, MLS: multi-branch laser station, RLS: repeater laser station, bEDFA: bidirectional erbium doped fiber amplifier, U: user.CC-BY · From the PDF
Figure 2 Principle of an optical link with simultaneous assessment of the residual noise and accuracy. The input and transmitted frequency comparison, so-called end-to-end measurement, gives an upper value of the up-link and down-link stabilities and accuracies (see supplementary for details).
Figure 2 Principle of an optical link with simultaneous assessment of the residual noise and accuracy. The input and transmitted frequency comparison, so-called end-to-end measurement, gives an upper value of the up-link and down-link stabilities and accuracies (see supplementary for details).CC-BY · From the PDF
Figure 3 (a) Schematic of a multi-branch laser station (PD = photodiode, PC = polarization controller, AOM = acousto-optic modulator, TW = two-way, ANC = active noise compensation). (b) Schematic of the interferometric ensemble (FM = Faraday mirror, PD = photodiode).
Figure 3 (a) Schematic of a multi-branch laser station (PD = photodiode, PC = polarization controller, AOM = acousto-optic modulator, TW = two-way, ANC = active noise compensation). (b) Schematic of the interferometric ensemble (FM = Faraday mirror, PD = photodiode).CC-BY · From the PDF
Figure 4 Characterization of the noise floor of the multi-branch interferometric ensemble of the different MLSs. Fractional stability versus averaging time of the free space interferometer from MLS1 (blue circles) and from ML2 (red triangles) without (continuous line) and with (dashed line) correction or common noise rejection and of the free space interferometer from MLS3 (green squares). Inset: phase fluctuations of the three measurements (one optical cycle lasts 5 fs).
Figure 4 Characterization of the noise floor of the multi-branch interferometric ensemble of the different MLSs. Fractional stability versus averaging time of the free space interferometer from MLS1 (blue circles) and from ML2 (red triangles) without (continuous line) and with (dashed line) correction or common noise rejection and of the free space interferometer from MLS3 (green squares). Inset: phase fluctuations of the three measurements (one optical cycle lasts 5 fs).CC-BY · From the PDF
Image 5
CC-BY · From the PDF
Figure 6 Stability (MDEV) of the four links using MLSs, for the data displayed on figure 5, together with the free-running stability of the first span of each links.
Figure 6 Stability (MDEV) of the four links using MLSs, for the data displayed on figure 5, together with the free-running stability of the first span of each links.CC-BY · From the PDF
Figure 7 Uptime and stabilities over 2 years of two links departing from an MLS. The period is divided into bins of 15 days. Data concerning the Paris-Strasbourg-Paris link (link C) are in blue, and the ones concerning the SYRTE-LPL-SYRTE link (link A) in red. The circles correspond to stabilities at 1 s averaging time and the squares at 100 000 s. These stabilities are calculated for bins with uptime greater than the mean uptime, 75% and 66% for links A and C respectively (black dotted lines on upper graph). Data meeting these criteria are highlighted in sky blue in the lower graphs.
Figure 7 Uptime and stabilities over 2 years of two links departing from an MLS. The period is divided into bins of 15 days. Data concerning the Paris-Strasbourg-Paris link (link C) are in blue, and the ones concerning the SYRTE-LPL-SYRTE link (link A) in red. The circles correspond to stabilities at 1 s averaging time and the squares at 100 000 s. These stabilities are calculated for bins with uptime greater than the mean uptime, 75% and 66% for links A and C respectively (black dotted lines on upper graph). Data meeting these criteria are highlighted in sky blue in the lower graphs.CC-BY · From the PDF
Figure 8 Long-term stability (OADEV) of the SYRTE-Strasbourg-SYRTE link (C, solid line and blue squares) and the SYRTE-LPL-SYRTE link (A, solid line and red squares) calculated from the averaged frequencies on periods spanning 2160 s. 31% and 47% of the data have been removed for links A and C respectively. Dotted lines follow a slope of τ -1/2 (represented by the dashed lines in light blue and red). Dotted lines and circles show the long-term stability when removed data were replaced by Gaussian noise. Dashed vertical lines correspond to the position of the bump expected for sinusoidal frequency fluctuations with periods 1 day and 1 year respectively.
Figure 8 Long-term stability (OADEV) of the SYRTE-Strasbourg-SYRTE link (C, solid line and blue squares) and the SYRTE-LPL-SYRTE link (A, solid line and red squares) calculated from the averaged frequencies on periods spanning 2160 s. 31% and 47% of the data have been removed for links A and C respectively. Dotted lines follow a slope of τ -1/2 (represented by the dashed lines in light blue and red). Dotted lines and circles show the long-term stability when removed data were replaced by Gaussian noise. Dashed vertical lines correspond to the position of the bump expected for sinusoidal frequency fluctuations with periods 1 day and 1 year respectively.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Delva, 2017, Test of special relativity using a fiber network of optical clocks, Phys. Rev. Lett., 118, 10.1103/physrevlett.118.221102 · DOI · Paper page

Cited by

See all 76

Metadata

Authors
Cantin, E., Tønnes, M., Le Targat, R., Amy-Klein, A., Lopez, O., & Pottie, P.-E.
Affiliations
Centre National de la Recherche Scientifique (FR)
Corresponding author
Cantin, Etienne
Venue
New Journal of Physics
Published
2021-05-01
Volume
23
Issue
5
Pages
053027
ISSN
1367-2630 (ISSN-L)
OpenAlex
W3130885920
Cited by
59
References
38
Citations by year
2026: 10 · 2025: 8 · 2024: 9 · 2023: 15 · 2022: 11 · 2021: 6
FWCI
4.69
Type
journal article
Language
en
Open access
Licence
Locations
  • New Journal of Physics (publishedVersion, cc-by)
  • HAL (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • Agence Nationale de la Recherche (ANR-10-IDEX-0001-002-PSL, Equipex REFIMEVE+ ANR-11-EQPX-0039, Labex First TF ANR-10-LABX-48-01)
  • European Metrology Programme for Innovation and Research (OFTEN 15SIB05)
  • Conseil Régional Ile de France (DIM IFRAF)
  • Conseil Régional Bourgogne Franche Comté
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
Keywords
frequency stability, frequency accuracy, noise floor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.