Absolute frequency measurement of the 88 Sr + clock transition using a GPS link to the SI second
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
We report the results of a recent measurement of the absolute frequency of the 5 s 2 S 1 / 2 – 4 d 2 D 5 / 2 transition of the 88 S r + ion. The optical frequency was measured against the international atomic time realization of the SI second on the geoid as obtained by frequency transfer using a global positioning system link and the precise point positioning technique. The measurement campaign yielded more than 100 h of frequency data. It was performed with improvements to the stability and accuracy of the single-ion clock compared to the last measurement made in 2012. The single ion clock uncertainty is evaluated at 1.5 × 10 − 17 when contributions from acousto-optic modulator frequency chirps and servo errors are taken into account. The stability of the ion clock is 3 × 10 − 15 at 1 s averaging, a factor of three better than in the previous measurement. The results from the two measurement campaigns are in good agreement. The uncertainty of the measurement, primarily from the link to the SI second, is 0.75 Hz ( 1.7 × 10 − 15 ). The frequency measured for the S – D clock transition of 88 S r + is ν 0 = 444 779 044 095 485.27 ( 75 ) Hz.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. (2004) · Science · doi:10.1126/science.1105497 · Cited by 301
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279
Fortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Shift ofS122hyperfine splittings due to blackbody radiation
Itano, W. M., Lewis, L. L., & Wineland, D. J. (1982) · Physical Review A · doi:10.1103/physreva.25.1233 · Cited by 219
Geodetic techniques for time and frequency comparisons using GPS phase and code measurements
Ray, J., & Senior, K. (2005) · Metrologia · doi:10.1088/0026-1394/42/4/005 · Cited by 173
Schrama, C. A., Peik, E., Smith, W. W., & WALTHER, H. (1993) · Optics Communications · doi:10.1016/0030-4018(93)90318-y · Cited by 172
1 × 10−16frequency transfer by GPS PPP with integer ambiguity resolution
Petit, G., Kanj, A., Loyer, S., Delporte, J., Mercier, F., & Perosanz, F. (2015) · Metrologia · doi:10.1088/0026-1394/52/2/301 · Cited by 168
Research works printed but not linked: 1
- Mireault, 2008, Online precise point positioning: a new, timely service from Natural Resources Canada, GPS World, 19, 59
Cited by
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Pizzocaro, M., Bregolin, F., Barbieri, P., Rauf, B., Levi, F., & Calonico, D. (2020) · Metrologia · doi:10.1088/1681-7575/ab50e8 · Cited by 63
Hobson, R., Bowden, W., Vianello, A., Silva, A., Baynham, C. F. A., Margolis, H. S., Baird, P. E. G., Gill, P., & Hill, I. R. (2020) · Metrologia · doi:10.1088/1681-7575/abb530 · Cited by 58
First accuracy evaluation of the NRC-FCs2 primary frequency standard
Beattie, S., Jian, B., Alcock, J. A., Gertsvolf, M., Hendricks, R., Szymaniec, K., & Gibble, K. (2020) · Metrologia · doi:10.1088/1681-7575/ab7c54 · Cited by 52
Self-citationThe CIPM list ‘Recommended values of standard frequencies’: 2021 update
Margolis, H. S., Panfilo, G., Petit, G., Oates, C. W., Ido, T., & Bize, S. (2024) · Metrologia · doi:10.1088/1681-7575/ad3afc · Cited by 48
Precision Measurements of the Ba+138 6sS21/2−5dD25/2 Clock Transition
Arnold, K. J., Kaewuam, R., Chanu, S. R., Tan, T. R., Zhang, Z., & Barrett, M. D. (2020) · Physical Review Letters · doi:10.1103/physrevlett.124.193001 · Cited by 34
Baynham, C. F. A., Godun, R. M., Jones, J. M., King, S. A., Nisbet-Jones, P. B. R., Baynes, F., Rolland, A., Baird, P. E. G., Bongs, K., Gill, P., et al. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2017.1384514 · Cited by 32
Steinel, M., Shao, H., Filzinger, M., Lipphardt, B., Brinkmann, M., Didier, A., Mehlstäubler, T. E., Lindvall, T., Peik, E., & Huntemann, N. (2023) · Physical Review Letters · doi:10.1103/physrevlett.131.083002 · Cited by 44
Chronometric Geodesy: Methods and Applications
Delva, P., Denker, H., & Lion, G. (2019) · Fundamental Theories of Physics · doi:10.1007/978-3-030-11500-5_2 · Cited by 28
“transfer can be realized using radiofrequency signals (of order 1-10 GHz) with well established techniques [83], and in the optical domain with lasers [84]. GNSS (Global Navigation Satellite Systems) [85, 86, 87, 88, 89] and TWSTFT (Two-Way Satellite Time and Frequency Transfer) [90, 91, 83, 92, 93] have been widely u…”
MethodLindvall, T., Fordell, T., Hanhijärvi, K., Doležal, M., Rahm, J., Weyers, S., & Wallin, A. E. (2025) · Physical Review Applied · doi:10.1103/czlf-bfvp · Cited by 29
Ma, Z. Y., Liu, H.-X., Wei, W. Z., Yuan, W. H., Hao, P., Deng, Z., Che, H., Xu, Z., Cheng, F. H., Wang, Z., et al. (2020) · Applied Physics B · doi:10.1007/s00340-020-07479-4 · Cited by 15
Improved absolute frequency measurement of the strontium ion clock using a GPS link to the SI second
Jian, B., Bernard, J. E., Gertsvolf, M., & Dubé, P. (2022) · Metrologia · doi:10.1088/1681-7575/aca615 · Cited by 17
Self-citationMagic polarization for cancellation of light shifts in two-photon optical clocks
Jackson, S., & Vutha, A. C. (2019) · Physical Review A · doi:10.1103/physreva.99.063422 · Cited by 13
Absolute frequency measurement of a 88Sr+ clock by direct comparison to a primary frequency standard
Marceau, C., Beattie, S., Kato, K., Jian, B., Gertsvolf, M., & Dubé, P. (2025) · Metrologia · doi:10.1088/1681-7575/ade4d1 · Cited by 10
Self-citationIntercombination line frequencies in 171 Yb validated with the clock transition
Jones, D. M., van Kann, F. J., & McFerran, J. J. (2023) · Applied Optics · doi:10.1364/ao.488653 · Cited by 8
“The difference between the predicted UTC (as GNSS uses) and the post-processed true-UTC published in the BIPM Circular T should not affect the results here, as they are in the 10−15 range [33]”
MethodPast and Future of Optical Clocks Toward Redefinition of the SI Second
Ido, T. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2874333 · Cited by 8
Advances in the uncertainty evaluation of a 88Sr+ single ion optical clock
Dubé, P., Jian, B., & Vutha, A. C. (2018) · European Frequency and Time Forum · doi:10.1109/eftf.2018.8409058 · Cited by 4
“The servo algorithm was modified to include tracking of the cavity drift rate [10], [11].”
BackgroundMethodSelf-citationNoise-induced servo errors in optical clocks utilizing Rabi interrogation
Lindvall, T., Wallin, A. E., Hanhijärvi, K., & Fordell, T. (2023) · Metrologia · doi:10.1088/1681-7575/acdfd4 · Cited by 3
Guodong, 赵. Z., Lu, X., & Chang, H. (2023) · Laser & Optoelectronics Progress · doi:10.3788/lop223237 · Cited by 3
Godun, R. M., Baynham, C. F. A., Jones, J. M., King, S. A., Nisbet-Jones, P. B. R., Baynes, F. N., Rolland, A., Baird, P. E. G., Bongs, K., Gill, P., et al. (2018) · European Frequency and Time Forum · doi:10.1109/eftf.2018.8409057 · Cited by 3
“Alternatively, however, the SI second can be accessed via a frequency link to International Atomic Time (TAI) [2-7].”
BackgroundCalibration of Gigahertz Microwave Generator for the Programmable Josephson Voltage Standard at NRC
Gertsvolf, M., & Granger, G. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2884047 · Cited by 1
Self-citationAbsolute frequency measurement of the electric quadrupole transition of 88Sr+
Dubé, P., Bernard, J. E., & Gertsvolf, M. (2017) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2017.8089042
“The maser was itself calibrated using a GPS frequency link to the SI second [7].”
MethodInfluentialSelf-citationDesign of a Low Uncertainty Ion Trap for a Transportable Ion Optical Clock
Dubé, P. (2019) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2019.8855992
“At the National Research Council of Canada (NRC), the only method at our disposal to compare our 88Sr+ ion clock to other optical clocks or to the SI second is with a GPS link, currently limited in accuracy to about 10−15 in fractional frequency units [2].”
MethodSelf-citationHiggins, G. T. (2019) · Springer theses · doi:10.1007/978-3-030-33770-4_3
Frequency Comb Development at the NRC
Marceau, C., Beattie, S., & Gertsvolf, M. (2022) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs54560.2022.9850503
Self-citationAbsolute Frequency Measurement of the Sr+ Ion Optical Clock With a Fourfold Uncertainty Reduction
Dubé, P., Jian, B., & Gertsvolf, M. (2022) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs54560.2022.9850706
Self-citationTraceability of optical frequency to SI second via UTC(NIM)
Wang, Y., Lin, Y., Gao, Y., & Zhang, A. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.970450
Experimental platform towards in-fibre atom optics and laser cooling
Adnan, M. (2017) · theses.fr (ABES) · doi:10.70675/0196aff3z168cz4ee9zaeafzf2277149b707 · Cited by 2
Martínez, H. Á. (2021) · theses.fr (ABES) · doi:10.70675/f4d4b814z0e3bz417fz9e16z11828e4b2ec3 · Cited by 3
High-Accuracy Optical Frequency Metrology: traceability at the 1E-17 level
Barbieri, P. (2020) · PORTO@Iris
Metadata
- Authors
- Dubé, P., Bernard, J. E., & Gertsvolf, M.
- Affiliations
- National Research Council Canada (CA)
- Corresponding author
- Dubé, Pierre
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2017-03-05
- Volume
- 54
- Issue
- 3
- Pages
- 290-298
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2605209510
- Cited by
- 28
- References
- 36
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 4 · 2022: 4 · 2021: 1 · 2020: 4 · 2019: 5 · 2018: 5 · 2017: 3
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Metrologia (publishedVersion)
- NPARC (submittedVersion)
- Funders
- National Research Council Canada
- Natural Resources Canada
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- optical frequency measurement, SI second, frequency transfer, precise point positioning, frequency stability, frequency metrology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.