Electric stimulus duration alters network-mediated responses depending on retinal ganglion cell type
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To improve the quality of artificial vision that arises from retinal prostheses, it is important to bring electrically-elicited neural activity more in line with the physiological signaling patterns that arise normally in the healthy retina. Our previous study reported that indirect activation produces a closer match to physiological responses in ON retinal ganglion cells (RGCs) than in OFF cells (Im and Fried 2015 J. Physiol. 593 3677-96). This suggests that a preferential activation of ON RGCs would shape the overall retinal response closer to natural signaling. Recently, we found that changes to the rate at which stimulation was delivered could bias responses towards a stronger ON component (Im and Fried 2016a J. Neural Eng. 13 025002), raising the possibility that changes to other stimulus parameters can similarly bias towards stronger ON responses. Here, we explore the effects of changing stimulus duration on the responses in ON and OFF types of brisk transient (BT) and brisk sustained (BS) RGCs. APPROACH: We used cell-attached patch clamp to record RGC spiking in the isolated rabbit retina. Targeted RGCs were first classified as ON or OFF type by their light responses, and further sub-classified as BT or BS types by their responses to both light and electric stimuli. Spiking in targeted RGCs was recorded in response to electric pulses with durations varying from 5 to100 ms. Stimulus amplitude was adjusted at each duration to hold total charge constant for all experiments. MAIN RESULTS: We found that varying stimulus durations modulated responses differentially for ON versus OFF cells: in ON cells, spike counts decreased significantly with increasing stimulus duration while in OFF cells the changes were more modest. The maximum ratio of ON versus OFF responses occurred at a duration of ~10 ms. The difference in response strength for BT versus BS cells was much larger in ON cells than in OFF cells. SIGNIFICANCE: The stimulation rates preferred by subjects during clinical trials are similar to the rates that maximize the ON/OFF response ratio in in vitro testing (Im and Fried 2016a J. Neural Eng. 13 025002). Here, we determine the stimulus duration that produces the strongest bias towards ON responses and speculate that it will further enhance clinical effectiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The functional diversity of retinal ganglion cells in the mouse
Baden, T., Berens, P., Franke, K., Román Rosón, M., Bethge, M., & Euler, T. (2016) · Nature · doi:10.1038/nature16468 · Cited by 999
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 1×
“Proof of principle for this approach has been repeatedly demonstrated in clinical testing (Humayun et al 2003, Rizzo et al 2003, Fujikado et al 2007, Zrenner et al 2011, Stingl et al 2013, da Cruz et al 2013, Shivdasani et al 2014, 2017, Hornig et al 2017) but unfortunately, the quality of…”
ResultSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 1×
“Proof of principle for this approach has been repeatedly demonstrated in clinical testing (Humayun et al 2003, Rizzo et al 2003, Fujikado et al 2007, Zrenner et al 2011, Stingl et al 2013, da Cruz et al 2013, Shivdasani et al 2014, 2017, Hornig et al 2017) but unfortunately, the quality of…”
ResultRetinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · cited 2×
“…et al 2007, Zrenner et al 2011, Stingl et al 2013, da Cruz et al 2013, Shivdasani et al 2014, 2017, Hornig et al 2017) but unfortunately, the quality of vision elicited is still far removed from that which occurs naturally (Zrenner et al 2011, Stingl et al 2013, da Cruz et al 2013).”
BackgroundWilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155 · cited 1×
“…intriguing that stimulation strategies that preferentially bias the ON system in our in vitro experiments (Im and Fried 2016a) are similar to those that improve psychophysical outcomes (Wilke et al 2011, Zrenner et al 2011, Pérez Fornos et al 2012, Stingl et al 2013, 2015, Chuang et al 2014).”
ResultImproving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154
Cited by
Optically Stimulated Artificial Synapse Based on Layered Black Phosphorus
Ahmed, T., Kuriakose, S., Mayes, E. L. H., Ramanathan, R., Bansal, V., Bhaskaran, M., Sriram, S., & Walia, S. (2019) · Small · doi:10.1002/smll.201900966 · Cited by 335
Stimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
“The same group later also found that the duration strength curves were different for brisk transient and brisk sustained cells (Im et al., 2018).”
BackgroundInfluentialAdvances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19
Corna, A., Ramesh, P., Jetter, F., Lee, M.-J., Macke, J. H., & Zeck, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0679 · Cited by 18
Metadata
- Authors
- Im, M., Werginz, P., & Fried, S. I.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-03-06
- Volume
- 15
- Issue
- 3
- Pages
- 036010
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2588690677
- Cited by
- 58
- References
- 17
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electric stimulus duration alters network-mediated responses depending on retinal ganglion cell type. https://app.cochat.ai/papers/10.1088/1741-2552/aaadc1
- The paper
- Im, M., Werginz, P., & Fried, S. I. (2018). Electric stimulus duration alters network-mediated responses depending on retinal ganglion cell type. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/aaadc1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.