Compliant peripheral nerve interfaces.
Open accessThe DOI matches its Crossref record; 247 of the 253 references it cites were found in a registry or an index; none of the 3 sources its claims cite is checked for support yet.
Abstract
This paper reviews recent progress in the development of flexible and implantable PNIs, highlighting materials selection, fabrication methods, and interface designs.
Overview
CoChat Summary
TL;DR
This topical review surveys recent progress in mechanically compliant peripheral nerve interfaces (PNIs), focusing on materials, fabrication, and integrated functions for flexible implantable systems. It argues that long-term PNI performance is limited by implant–tissue damage and foreign body response, and that compliance is a key strategy to improve chronic function.
Key findings
- PNIs are used for both research and therapy, including closed-loop control of neuroprosthetic limbs, treatment of neuropathic pain, and restoration of functions such as breathing and bladder management.
- The review highlights three main interface classes: intraneural, extraneural, and regenerative, and three modulation modalities: electrical, optical, and chemical.
- A central challenge is that implantable PNIs can provide enhanced selectivity over non-invasive approaches, but their long-term functionality is limited by tissue damage at the implant–tissue interface.
- The paper emphasizes that compliant PNIs are designed to match nerve anatomy and dynamic motion in order to limit foreign body response.
Methods
- Topical review article: the paper synthesizes recent literature rather than reporting a new experimental study.
- Scope of the review covers flexible and implantable PNIs, with attention to materials selection, fabrication methods, integrated functions, and interface design categories.
- Main analysis is qualitative and comparative, discussing design trade-offs and challenges in integrating PNIs on compliant substrates.
Limitations
- The paper does not present original experimental data or a quantitative meta-analysis; this is evident from the text as a review article.
- It states that long-term functionality remains limited by tissue damage and implant–tissue interface issues, indicating an unresolved design limitation.
- The text makes clear that integrating electrical, optical, and chemical functions on compliant substrates remains challenging.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 2 Not valid · 2 Not checked · 5 Own results and interpretations
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Nevertheless, the long-term functionality of implantable PNIs is limited by tissue damage, which occurs at the implant–tissue interface”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim have been checked yet.
In the paper
“challenging to capture following PN injury [15, 16]”
What the sources say
- Not checked yetcites [15] Navarro, 1998, Stimulation and recording from regenerated peripheral nerves through polyimide sieve electrodes, J. Peripher. Nerv. Syst.
- Not checked — no full text of the sourcecites [16] Dario, 1998, Neural interfaces for regenerated nerve stimulation and recording, IEEE Trans. Rehabil. Eng. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
1 reference still to check
A free account verifies the references that are still open.
- Probably not a substantial claim. 7
- It may state two separate claims as one. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Neuromodulation of the autonomic nerves, which regulates non-volitional bodily processes such as those of the cardiovascular, gastrointestinal, and immune systems, has shown therapeutic benefits in diseases including heart failure, lung injury, inflammation, rheumatoid arthritis, obesity, and diabetes [11], [12].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [12]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Recently, interfascicular interfaces were called the 'least common in literature' [47].”
From Directed stimulation with interfascicular interfaces for peripheral nerve stimulation (2021) · cites this paper as [47]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Patientspecific methods of addressing the peripheral nerves require close inspection of neural activity to optimise the position of electrodes [12], the stimulation algorithm, and analysis methods of neural activity according to the individual needs of patients [218].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [12]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“This improves longevity by addressing interface compromising factors such as the foreign body reaction, which can deteriorate the neural interface and isolate the nerve fibers through scarring [12], [206].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [12]
Experimental — accuracy not yet measured
Citations
Cites
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861 · cited 2×
“Specifically, when designing optical interfaces for optogenetics, it is necessary to ensure a minimum irradiance in the range of 1–5 mW mm−2 to target fibers [183, 184].”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 2×
“Electrical stimulation also contributes to the degradation of metallic electrodes, as non-reversible electrochemical reactions may occur when injecting high currents [88, 89].”
BackgroundCurrent Problems of Lower Vertebrate Phylogeny
Romanes, G. J. (1969) · Journal of Anatomy · Cited by 1,830
The stiffness of living tissues and its implications for tissue engineering
Guimarães, C. F., Gasperini, L., Marques, A. P., & Reis, R. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0169-1 · Cited by 1,515 · cited 2×
“PNs are heterogeneous anisotropic structures and, similarly to other tissues in the body [44], they display highly nonlinear and viscoelastic properties, stiffening at large strains, and they present stress relaxation behaviour when stretched.”
BackgroundMechanisms of neuropathic pain
Campbell, J. N., & Meyer, R. A. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.021 · Cited by 1,471
Guyton and Hall: Textbook of Medical Physiology
Khonsary, S. (2017) · Surgical Neurology International · doi:10.4103/sni.sni_327_17 · Cited by 1,394 · cited 2×
“and function have been shown to be strictly correlated [24, 25] (figure 2(c)).”
BackgroundKoopman, F. A., Chavan, S. S., Miljko, S., Grazio, S., Sokolovic, S., Schuurman, P. R., Mehta, A. D., Levine, Y. A., Faltys, M., Zitnik, R., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605635113 · Cited by 1,024 · cited 2×
“[32] Koopman F A et al 2016 Vagus nerve stimulation inhibits”
BackgroundRestoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 2×
“[205] Raspopovic S et al 2014 Restoring natural sensory feedback”
BackgroundSelf-citationAravanis, A. M., Wang, L.-P., Zhang, F., Meltzer, L. A., Mogri, M. Z., Schneider, M. B., & Deisseroth, K. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s02 · Cited by 970 · cited 6×
“For applications in the CNS, these limitations have been partially overcome by fabricating thin film GaN microLEDs [180, 181], while similar approaches remain to be tested in the PNS.”
BackgroundInfluentialCONDUCTION VELOCITY AND DIAMETER OF NERVE FIBERS
Hursh, J. B. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.131 · Cited by 916
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics
Park, S. I., Brenner, D. S., Shin, G., Morgan, C. D., Copits, B. A., Chung, H. U., Pullen, M. Y., Noh, K. N., Davidson, S., Oh, S. J., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3415 · Cited by 794 · cited 2×
“These miniaturized components feature a relatively low power consumption, which makes it possible to employ wireless operation, whether it is through the use of an RF harvesting unit and rectifier circuit for power and data transmission [176] or through the use of a battery-powered headstage component [179].”
BackgroundMaterials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738 · cited 3×
“Consequently, in recent years, the field has evolved requiring not only expertise in neuroscience and engineering, but also in materials science to develop implantable interfaces with flexible and soft materials to minimize implant invasiveness and footprint [20].”
BackgroundSelf-citationMenorca, R. M. G., Fussell, T. S., & Elfar, J. C. (2013) · Hand Clinics · doi:10.1016/j.hcl.2013.04.002 · Cited by 729
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708 · cited 2×
“Moreover, like other organs, the behaviour at the microscopic level does not translate linearly to the whole nerve, making mechanical studies also scale-dependent [45].”
BackgroundChannelrhodopsin-2 and optical control of excitable cells
Zhang, F., Wang, L.-P., Boyden, E. S., & Deisseroth, K. (2006) · Nature Methods · doi:10.1038/nmeth936 · Cited by 689 · cited 2×
“Specifically, when designing optical interfaces for optogenetics, it is necessary to ensure a minimum irradiance in the range of 1–5 mW mm−2 to target fibers [183, 184].”
BackgroundCanales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668 · cited 2×
“The ability to manipulate nerves with combined approaches is of broad interest in the field of PNIs and could still potentially benefit from current technologies, such as multimaterial and multifunctional flexible fibers [198].”
BackgroundWireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
A biodegradable and biocompatible gecko-inspired tissue adhesive
Mahdavi, A., Ferreira, L., Sundback, C., Nichol, J. W., Chan, E. P., Carter, D. J. D., Bettinger, C. J., Patanavanich, S., Chignozha, L., Ben-Joseph, E., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0712117105 · Cited by 554 · cited 3×
“[107] Mahdavi A et al 2008 A biodegradable and biocompatible”
BackgroundMethodA wireless closed-loop system for optogenetic peripheral neuromodulation
Mickle, A. D., Won, S. M., Noh, K. N., Yoon, J., Meacham, K. W., Xue, Y., McIlvried, L. A., Copits, B. A., Samineni, V. K., Crawford, K. E., et al. (2019) · Nature · doi:10.1038/s41586-018-0823-6 · Cited by 514 · cited 2×
“Alternatively to temperature monitoring, heat generation in PNIs can be directly limited by mounting micro-LEDs on heat dissipating substrates such as stainless steel [188].”
BackgroundKoo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0196-2 · Cited by 496 · cited 2×
“38 1031–6 [235] Koo J et al 2018 Wireless bioresorbable electronic system enables sustained nonpharmacological neuroregenerative therapy Nat.”
BackgroundUsing temperature to analyse temporal dynamics in the songbird motor pathway
Long, M. A., & Fee, M. S. (2008) · Nature · doi:10.1038/nature07448 · Cited by 491 · cited 2×
“Cooling is known to reduce or silence neural activity, inducing physiological and behavioural changes [160].”
BackgroundImplanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · cited 1×
“[109] Grill W M, Norman S E and Bellamkonda R V 2009”
BackgroundA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 2×
“[97] Naples G G, Mortimer J T, Scheiner A and Sweeney J D”
BackgroundThermal constraints on in vivo optogenetic manipulations
Owen, S. F., Liu, M. H., & Kreitzer, A. C. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0422-3 · Cited by 413 · cited 2×
“[187] Owen S F, Liu M H and Kreitzer A C 2019 Thermal”
BackgroundEldabe, S., Buchser, E., & Duarte, R. V. (2016) · Pain Medicine · doi:10.1093/pm/pnv025 · Cited by 403 · cited 2×
“76 47–55 [61] Eldabe S, Buchser E and Duarte R V 2015 Complications of spinal cord stimulation and peripheral nerve stimulation techniques: a review of the literature Pain Med.”
BackgroundFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 3×
“Tyler and Durand have developed a slowly penetrating interfascicular nerve electrode (SPINE) [108], that consists of a cuff integrated with protruding finlike structures intended to pierce through the epineurium and settle close to internal fascicles.”
BackgroundDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 2×
“Despite welldocumented use in animal models, chronic testing in human nerves [77, 205, 206] and existing commercial devices (NeuroNexus Nerve Cuffs), PI is still not approved by the FDA to be used in implantable devices such as PNIs.”
BackgroundSelf-citationBiophysical Mechanisms of Transient Optical Stimulation of Peripheral Nerve
Wells, J., Kao, C., Konrad, P., Milner, T., Kim, J., Mahadevan-Jansen, A., & Jansen, E. D. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104786 · Cited by 386
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386 · cited 4×
“[133] Cogan S F, Ludwig K A, Welle C G and Takmakov P 2016”
BackgroundInfluentialTopp, K. S., & Boyd, B. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.1.92 · Cited by 361 · cited 3×
“their dynamic environment [17], and innately high immune surveillance [18, 19].”
BackgroundValle, G., Mazzoni, A., Iberite, F., D’Anna, E., Strauss, I., Granata, G., Controzzi, M., Clemente, F., Rognini, G., Cipriani, C., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.08.033 · Cited by 345
Self-citationMorphing electronics enable neuromodulation in growing tissue
Liu, Y., Li, J., Song, S., Kang, J., Tsao, Y., Chen, S., Mottini, V., McConnell, K., Xu, W., Zheng, Y.-Q., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0495-2 · Cited by 325 · cited 2×
“5 eaaw1066 [234] Liu Y et al 2020 Morphing electronics enable neuromodulation in growing tissue Nat.”
BackgroundSelective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320 · cited 2×
“For instance, tripolar electrodes that present evenly spaced rows of three contacts, can generate modulated transversal and/or longitudinal currents, targetingmore superficial fascicles [63, 64].”
BackgroundShon, A., Chu, J.-U., Jung, J., Kim, H., & Youn, I. (2017) · Sensors · doi:10.3390/s18010001 · Cited by 320 · cited 2×
“By integrating stimulation and recording electrodes in a single PNI, however, a major concern is associated with the generation of stimulation artifacts, which can lead to loss of recording information and requires specific signal processing or additional circuitry to be rejected [197].”
BackgroundLundborg, G., Myers, R., & Powell, H. (1983) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.46.12.1119 · Cited by 316 · cited 2×
“The perineurium forms the socalled ‘blood-nerve barrier’ (BNB), that biologically seals the fascicular environment, regulating protein diffusion and blocking external pathogens thanks to a slightly positive inner pressure [22].”
BackgroundComplications of peripheral nerve blocks
Jeng, C. L., Torrillo, T. M., & Rosenblatt, M. A. (2010) · British Journal of Anaesthesia · doi:10.1093/bja/aeq273 · Cited by 314
Zhang, Y., Zheng, N., Cao, Y., Wang, F., Wang, P., Ma, Y., Lu, B., Hou, G., Fang, Z., Liang, Z., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw1066 · Cited by 314
Induced Hypothermia Does Not Harm Hemodynamics after Polytrauma: A Porcine Model
Weuster, M., Mommsen, P., Pfeifer, R., Mohr, J., Ruchholtz, S., Flohé, S., Fröhlich, M., Keibl, C., Seekamp, A., van Griensven, M., et al. (2015) · Mediators of Inflammation · doi:10.1155/2015/829195 · Cited by 313
Sacral anterior root stimulators for bladder control in paraplegia: the first 50 cases
Brindley, G. S., Polkey, C. E., Rushton, D. N., & Cardozo, L. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.10.1104 · Cited by 313 · cited 4×
“[12] Brindley G S, Polkey C E, Rushton D N and Cardozo L”
BackgroundInfluentialEmerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 291
Mechanical properties of acellular peripheral nerve
Borschel, G. H., Kia, K. F., Kuzon, W. M., & Dennis, R. G. (2003) · Journal of Surgical Research · doi:10.1016/s0022-4804(03)00255-5 · Cited by 284 · cited 2×
“316 115–21 [55] Borschel G H, Kia K F, Kuzon WM and Dennis R G 2003 Mechanical properties of acellular peripheral nerve J.”
BackgroundStimulus waveforms for selective neural stimulation
Grill, W. M., & Mortimer, J. T. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.395310 · Cited by 280 · cited 2×
“40 640–53 [65] Mortimer J T and Bhadra N 2018 Chapter 6—fundamentals of electrical stimulation Neuromodulation 2nd edn, ed E S Krames, P H Peckham and A R Rezai (New York: Academic) pp 71–82 [66] Grill W M and Mortimer J T 1995 Stimulus waveforms for selective neural stimulation IEEE Eng.”
BackgroundMethodSensory feedback restoration in leg amputees improves walking speed, metabolic cost and phantom pain
Petrini, F. M., Bumbasirevic, M., Valle, G., Ilic, V., Mijović, P., Čvančara, P., Barberi, F., Katic, N., Bortolotti, D., Andreu, D., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0567-3 · Cited by 269
Self-citationEnhancing functional abilities and cognitive integration of the lower limb prosthesis
Petrini, F. M., Valle, G., Bumbasirevic, M., Barberi, F., Bortolotti, D., Cvancara, P., Hiairrassary, A., Mijovic, P., Sverrisson, A. Ö., Pedrocchi, A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav8939 · Cited by 265 · cited 2×
“[76] Petrini F M et al 2019 Enhancing functional abilities and”
BackgroundSelf-citationStrong adhesion of wet conducting polymers on diverse substrates
Inoue, A., Yuk, H., Lu, B., & Zhao, X. (2020) · Science Advances · doi:10.1126/sciadv.aay5394 · Cited by 260
Self-Contained Neuromusculoskeletal Arm Prostheses
Ortiz-Catalan, M., Mastinu, E., Sassu, P., Aszmann, O., & Brånemark, R. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1917537 · Cited by 256 · cited 2×
“[212] Ortiz-Catalan M, Mastinu E, Sassu P, Aszmann O and”
BackgroundOrganic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · cited 3×
“[112] Lago N, Yoshida K, Koch K P and Navarro X 2007”
BackgroundBueche, F. (1977) · The Physics Teacher · doi:10.1119/1.2339783 · Cited by 224
Virally mediated optogenetic excitation and inhibition of pain in freely moving nontransgenic mice
Iyer, S. M., Montgomery, K. L., Towne, C., Lee, S. Y., Ramakrishnan, C., Deisseroth, K., & Delp, S. L. (2014) · Nature Biotechnology · doi:10.1038/nbt.2834 · Cited by 218 · cited 1×
“[144] Iyer S M, Montgomery K L, Towne C, Lee S Y,”
BackgroundPeripheral Nerve Stimulation for Neuropathic Pain
Slavin, K. V. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.11.005 · Cited by 217 · cited 2×
“1 251–9 [5] Slavin K V 2008 Peripheral nerve stimulation for neuropathic pain Neurotherapeutics 5 100–6”
BackgroundGraczyk, E. L., Resnik, L., Schiefer, M. A., Schmitt, M. S., & Tyler, D. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-26952-x · Cited by 216 · cited 2×
“Similarly, other silicone-based extraneural interfaces, such as the FINE electrodes developed at Case Western Reserve University, have been implanted for up to 6 years restoring naturalistic sensation in upper limb amputees [103].”
BackgroundMethodNoninvasive sub-organ ultrasound stimulation for targeted neuromodulation
Cotero, V., Fan, Y., Tsaava, T., Kressel, A. M., Hancu, I., Fitzgerald, P., Wallace, K., Kaanumalle, S., Graf, J., Rigby, W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-08750-9 · Cited by 216 · cited 1×
“[147] Cotero V et al 2019 Noninvasive sub-organ ultrasound”
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215 · cited 2×
“Different designs and materials therefore influence the implantation protocols and the long-term performance of the device, affecting parameters such as SNR and scarring [94].”
BackgroundPrinciples Underlying New Methods for Chronic Neural Recording
Stein, R. B., Charles, D., Davis, L., Jhamandas, J., Mannard, A., & Nichols, T. R. (1975) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100020333 · Cited by 210 · cited 2×
“The earliest [95] and simplest geometry consists of split-cylinders: the nerve is gently laid into the tube held split open and secured in place upon closing of the cuff.”
BackgroundUltrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · cited 2×
“15 031001 [200] Rodri ́guez F J, Ceballos D, Schüttler M, Valero A, Valderrama E, Stieglitz T and Navarro X 2000 Polyimide cuff electrodes for peripheral nerve stimulation J.”
BackgroundA review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205 · cited 5×
“Standard methods, including casting, dipcoating, transfer processing and printing [199] are limited in resolution.”
BackgroundMethodInfluentialA nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196 · cited 2×
“For instance, tripolar electrodes that present evenly spaced rows of three contacts, can generate modulated transversal and/or longitudinal currents, targetingmore superficial fascicles [63, 64].”
BackgroundSix‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195 · cited 2×
“Despite welldocumented use in animal models, chronic testing in human nerves [77, 205, 206] and existing commercial devices (NeuroNexus Nerve Cuffs), PI is still not approved by the FDA to be used in implantable devices such as PNIs.”
BackgroundSelf-citationZhang, Y., Mickle, A. D., Gutruf, P., McIlvried, L. A., Guo, H., Wu, Y., Golden, J. P., Xue, Y., Grajales-Reyes, J. G., Wang, X., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw5296 · Cited by 195
Fully stretchable active-matrix organic light-emitting electrochemical cell array
Liu, J., Wang, J., Zhang, Z., Molina-Lopez, F., Wang, G.-J. N., Schroeder, B. C., Yan, X., Zeng, Y., Zhao, O., Tran, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17084-w · Cited by 195 · cited 2×
“11 8539–49 [247] Liu J et al 2020 Fully stretchable active-matrix organic light-emitting electrochemical cell array Nat.”
BackgroundNeurotrauma and Inflammation: CNS and PNS Responses
Mietto, B. S., Mostacada, K., & Martinez, A. M. B. (2015) · Mediators of Inflammation · doi:10.1155/2015/251204 · Cited by 181 · cited 2×
“their dynamic environment [17], and innately high immune surveillance [18, 19].”
BackgroundLago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176 · cited 3×
“As a result, these polymers have been used in recent decades to develop extraneural [186, 200, 201], intraneural [80, 112, 116, 202] and regenerative [123, 203, 204] devices alike.”
BackgroundSelf-citationRemote Optogenetic Activation and Sensitization of Pain Pathways in Freely Moving Mice
Daou, I., Tuttle, A. H., Longo, G., Wieskopf, J. S., Bonin, R. P., Ase, A. R., Wood, J. N., De Koninck, Y., Ribeiro-da-Silva, A., Mogil, J. S., et al. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.2424-13.2013 · Cited by 175 · cited 2×
“For instance, transdermal optical stimulation, performed via a laser, is often limited to superficial nerve endings [150, 151], as the light scatters within the tissue and can prevent the stimulation of deeper targets.”
BackgroundVagus nerve stimulation in experimental heart failure
Sabbah, H. N., Ilsar, I., Zaretsky, A., Rastogi, S., Wang, M., & Gupta, R. C. (2011) · Heart Failure Reviews · doi:10.1007/s10741-010-9209-z · Cited by 166 · cited 2×
“[33] Sabbah H N, Ilsar I, Zaretsky A, Rastogi S, Wang M and”
BackgroundStable long-term recordings from cat peripheral nerves
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D. (1977) · Brain Research · doi:10.1016/0006-8993(77)90233-5 · Cited by 160 · cited 2×
“[13] Stein R B, Nichols T R, Jhamandas J, Davis L and Charles D”
BackgroundEfficacy of vector control tools against malaria-infected mosquitoes
Mulatier, M., Camara, S., Koffi, A., Carrasco, D., Porciani, A., Chandre, F., Moiroux, N., Lefevre, T., Dabiré, R., Assi, S., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-43195-6 · Cited by 158
Optogenetic Control of Targeted Peripheral Axons in Freely Moving Animals
Towne, C., Montgomery, K. L., Iyer, S. M., Deisseroth, K., & Delp, S. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0072691 · Cited by 156 · cited 21×
“Sections 4.2 and 5.2 are dedicated to the strategies to reduce the FBR through different interactionmechanisms, drug eluting devices and soft biocompatible materials.”
BackgroundInfluentialKozai, T. D. Y., & Vazquez, A. L. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00108k · Cited by 150 · cited 2×
“The consequences of light propagation and intensity are also relevant when electrically recording elicited neural activity: the generation of photoelectric artifact, whose waveform can be similar to an AP, can contaminate data and complicate our understanding of the results [185].”
BackgroundBeyond the brain: Optogenetic control in the spinal cord and peripheral nervous system
Montgomery, K. L., Iyer, S. M., Christensen, A. J., Deisseroth, K., & Delp, S. L. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad7577 · Cited by 147 · cited 3×
“Despite the number of open issues in the application of optogenetics to the PNS, namely heat management and the immune response after viral injection [169], and, despite the currently limited translational prospective of this technique, optogenetics is becoming a well-established”
BackgroundInfluentialNoninvasive ultrasound stimulation of the spleen to treat inflammatory arthritis
Zachs, D. P., Offutt, S. J., Graham, R. S., Kim, Y., Mueller, J., Auger, J. L., Schuldt, N. J., Kaiser, C. R. W., Heiller, A. P., Dutta, R., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-08721-0 · Cited by 143 · cited 1×
“[146] Zachs D P et al 2019 Noninvasive ultrasound stimulation of”
BackgroundPardo, J. V., Sheikh, S. A., Kuskowski, M. A., Surerus-Johnson, C., Hagen, M. C., Lee, J. T., Rittberg, B. R., & Adson, D. E. (2007) · International Journal of Obesity · doi:10.1038/sj.ijo.0803666 · Cited by 142
Ware, T., Simon, D., Hearon, K., Liu, C., Shah, S., Reeder, J., Khodaparast, N., Kilgard, M. P., Maitland, D. J., Rennaker, R. L., et al. (2012) · Macromolecular Materials and Engineering · doi:10.1002/mame.201200241 · Cited by 138 · cited 2×
“7 15 [237] Ware T et al 2012 Three-dimensional flexible electronics enabled by shape memory polymer substrates for responsive neural interfacesMacromol.”
BackgroundOptimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies
Viswam, V., Obien, M. E. J., Franke, F., Frey, U., & Hierlemann, A. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00385 · Cited by 137
Emerging Soft Conductors for Bioelectronic Interfaces
Gao, D., Parida, K., & Lee, P. S. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201907184 · Cited by 136 · cited 2×
“noble metals can offer values up to 600 000 S cm−1 [242, 243].”
BackgroundThe foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135 · cited 20×
“[110] Christensen M B, Pearce S M, Ledbetter N M, Warren D J,”
BackgroundInfluentialA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · cited 2×
“Significant design and technological efforts have been dedicated to developing and improving implantable peripheral nerve interfaces (PNIs) that restore these impaired functions or alleviate debilitating conditions [9].”
BackgroundComplications of vagal nerve stimulation for drug-resistant epilepsy
Kahlow, H., & Olivecrona, M. (2013) · Seizure · doi:10.1016/j.seizure.2013.06.011 · Cited by 132 · cited 2×
“[92] Kahlow H and Olivecrona M 2013 Complications of vagal”
BackgroundCharkhkar, H., Shell, C. E., Marasco, P. D., Pinault, G. J., Tyler, D. J., & Triolo, R. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac964 · Cited by 131 · cited 1×
“[230] Charkhkar H, Shell C E, Marasco P D, Pinault G J, Tyler D J”
BackgroundSelective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · cited 1×
“[229] Schiefer M A, Polasek K H, Triolo R J, Pinault G C J and”
BackgroundNeural Prostheses for Restoration of Sensory and Motor Function
(2000) · CRC Press eBooks · doi:10.1201/9781420039054 · Cited by 122
Principles of designing interpretable optogenetic behavior experiments
Allen, B. D., Singer, A. C., & Boyden, E. S. (2015) · Learning & Memory · doi:10.1101/lm.038026.114 · Cited by 122 · cited 2×
“[166] Allen B D, Singer A C and Boyden E S 2015 Principles of”
BackgroundNon-invasive peripheral nerve stimulation via focused ultrasound in vivo
Downs, M. E., Lee, S. A., Yang, G., Kim, S., Wang, Q., & Konofagou, E. E. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa9fc2 · Cited by 121 · cited 1×
“58 692–700 [143] Downs M E, Lee S A, Yang G, Kim S, Wang Q and”
BackgroundConformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113 · cited 2×
“[182] Fallegger F, Schiavone G and Lacour S P 2020 Conformable”
BackgroundSelf-citationHuman nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode
Polasek, K. H., Hoyen, H. A., Keith, M. W., & Tyler, D. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891383 · Cited by 111 · cited 1×
“[31] Polasek K H, Hoyen H A, Keith MW and Tyler D J 2007”
BackgroundLower Extremity Functional Neuromuscular Stimulation in Cases of Spinal Cord Injury
Cybulski, G. R., Penn, R. D., & Jaeger, R. J. (1984) · Neurosurgery · doi:10.1227/00006123-198407000-00027 · Cited by 110 · cited 1×
“[29] Cybulski G R, Penn R D and Jaeger R J 1984 Lower”
BackgroundA slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · cited 4×
“[108] Tyler D J and Durand D M 1997 A slowly penetrating”
BackgroundInfluential(1998) · PubMed · Cited by 107
Optically mediated nerve stimulation: Identification of injury thresholds
Wells, J. D., Thomsen, S., Whitaker, P., Jansen, E. D., Kao, C. C., Konrad, P. E., & Mahadevan‐Jansen, A. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20522 · Cited by 105
Judson, J. P. (1968) · JAMA · doi:10.1001/jama.1968.03140120031007 · Cited by 103 · cited 3×
“The first PNIs appeared in the late 1960s and consisted in simple lead wires or metal foils, insulated in silicone rubber, and were applied primarily to the phrenic nerve for diaphragm pacing [2, 10] and to sacral roots for bladder control [11, 12].”
BackgroundBadia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103
Chronic interfacing with the autonomic nervous system using carbon nanotube (CNT) yarn electrodes
McCallum, G. A., Sui, X., Qiu, C., Marmerstein, J., Zheng, Y., Eggers, T. E., Hu, C., Dai, L., & Durand, D. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-10639-w · Cited by 102 · cited 2×
“For instance carbon fibers [218] or carbon nanotube yarn electrodes [219] have allowed chronic interfacing and easy access to small nerves (sub-mm) which are typically difficult to target with thick conventional materials.”
BackgroundCaldwell, R., Street, M. G., Sharma, R., Takmakov, P., Baker, B., & Rieth, L. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119731 · Cited by 100 · cited 2×
“The main concerns in the use of polymer-based implants are related to device encapsulation and longterm reliability and stability [207], and delamination within themultilayer structure that may be promoted by the wet and ionic environment of the body.”
BackgroundEffects of vagal stimulation on S-A and A-V nodes
Hamlin, R. L., & Cr, S. (1968) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1968.215.3.560 · Cited by 98 · cited 1×
“13 041002 [2] Glenn WW L and Phelps M L 1985 Diaphragm pacing by electrical stimulation of the phrenic nerve Neurosurgery 17 974–84 [3] Hamlin R and Smith C 1968 Effects of vagal stimulation on S-A and A-V nodes Am.”
BackgroundEpineural optogenetic activation of nociceptors initiates and amplifies inflammation
Michoud, F., Seehus, C. R., Schönle, P., Brun, N., Taub, D. G., Zhang, Z., Jain, A., Furfaro, I., Akouissi, O., Moon, R., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0673-2 · Cited by 98 · cited 2×
“These miniaturized components feature a relatively low power consumption, which makes it possible to employ wireless operation, whether it is through the use of an RF harvesting unit and rectifier circuit for power and data transmission [176] or through the use of a battery-powered headstage component [179].”
BackgroundSelf-citation“Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves”
Christie, B. P., Freeberg, M., Memberg, W. D., Pinault, G. J. C., Hoyen, H. A., Tyler, D. J., & Triolo, R. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0285-3 · Cited by 97 · cited 2×
“[211] Christie B P, Freeberg M, Memberg W D, Pinault G J C,”
BackgroundThin film multi-electrode softening cuffs for selective neuromodulation
González-González, M. A., Kanneganti, A., Joshi-Imre, A., Hernandez-Reynoso, A. G., Bendale, G., Modi, R., Ecker, M., Khurram, A., Cogan, S. F., Voit, W. E., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-34566-6 · Cited by 97 · cited 2×
“Electrochemically, coatings such as Pt black, IrOx and TiN are known to improve safety and stability of stimulation delivery [133], and can decrease electrode impedance ensuring better quality recordings [220].”
BackgroundEffects of high‐intensity focused ultrasound on nerve conduction
Foley, J. L., Little, J. W., & Vaezy, S. (2007) · Muscle & Nerve · doi:10.1002/mus.20932 · Cited by 91
Nicolai, E. N., Settell, M. L., Knudsen, B. E., McConico, A. L., Gosink, B. A., Trevathan, J. K., Baumgart, I. W., Ross, E. K., Pelot, N. A., Grill, W. M., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9db8 · Cited by 91 · cited 2×
“Methods 336 108602 [132] Nicolai E N et al 2020 Sources of off-target effects of vagus nerve stimulation using the helical clinical lead in domestic pigs J.”
BackgroundGuiraud, D., Andreu, D., Bonnet, S., Carrault, G., Couderc, P., Hagège, A., Henry, C., Hernandez, A., Karam, N., Le Rolle, V., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/041002 · Cited by 87 · cited 2×
“For amore comprehensive overviewof emerging therapeutic applications of VNSwe refer the reader to Guiraud et al [1].”
BackgroundStieglitz, T., Ruf, H. H., Gross, M., Schüettler, M., & Meyer, J.-U. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00019-2 · Cited by 86 · cited 2×
“Multiple configurations have been exposed in literature, using perforated arrays [15, 119, 120] and slotted structures [121].”
BackgroundOptogenetic control of nerve growth
Park, S., Koppes, R. A., Froriep, U. P., Jia, X., Achyuta, A. K. H., McLaughlin, B. L., & Anikeeva, P. (2015) · Scientific Reports · doi:10.1038/srep09669 · Cited by 83 · cited 2×
“Aside from neuromodulation purposes, optogenetic techniques are also being applied to promote nerve regrowth from specific cell populations, which can allow a better understanding of axonal growth mechanisms [140, 165].”
BackgroundMethodA three-dimensional self-opening intraneural peripheral interface (SELINE)
Cutrone, A., Valle, J. D., Santos, D., Badia, J., Filippeschi, C., Micera, S., Navarro, X., & Bossi, S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016016 · Cited by 82 · cited 2×
“Self-opening intraneural peripheral interfaces (SELINEs) are another evolution of the TIME: threedimensional (3D) shanks protruding out of the main shaft provide improved mechanical anchoring and nerve coverage [118].”
BackgroundSelf-citationHigh-Density μLED-Based Optical Cochlear Implant With Improved Thermomechanical Behavior
Klein, E., Gossler, C., Paul, O., & Ruther, P. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00659 · Cited by 81
Complications of Regional Anesthesia
Liguori, G. A. (2003) · Journal of Neurosurgical Anesthesiology · doi:10.1097/00008506-200401000-00018 · Cited by 80 · cited 2×
“Methods 156 71–75 [192] Liguori G A 2004 Complications of regional anesthesia: nerve injury and peripheral neural blockade J.”
BackgroundJuan, E. J., González, R., Albors, G., Ward, M. P., & Irazoqui, P. (2014) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22080 · Cited by 78 · cited 2×
“The fundamental mechanism through which ultrasounds interact with neural tissue is still unclear, with most theories being explored either through modelling [154] or acute experiments on exposed nerves [155, 156], which have often provided conflicting results.”
BackgroundRecent advances in materials and flexible electronics for peripheral nerve interfaces
Bettinger, C. J. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0007-6 · Cited by 77 · cited 2×
“37 573–80 [85] Bettinger C J 2018 Recent advances in materials and flexible electronics for peripheral nerve interfaces Bioelectron.”
BackgroundTripolar nerve cuff recording: stimulus artifact, EMG and the recorded nerve signal
Struijk, J. J., & Thomsen, M. (2002) · Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society · doi:10.1109/iembs.1995.579534 · Cited by 76 · cited 2×
“[71] Struijk J J and Thomsen M 1995 Tripolar nerve cuff”
BackgroundLong Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75 · cited 2×
“As a result, these polymers have been used in recent decades to develop extraneural [186, 200, 201], intraneural [80, 112, 116, 202] and regenerative [123, 203, 204] devices alike.”
BackgroundSelf-citationStretchable Low Impedance Electrodes for Bioelectronic Recording from Small Peripheral Nerves
Decataldo, F., Cramer, T., Martelli, D., Gualandi, I., Korim, W. S., Yao, S. T., Tessarolo, M., Murgia, M., Scavetta, E., Amici, R., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-46967-2 · Cited by 74 · cited 2×
“on Nano/Micro Engineered and Molecular Systems (NEMS) pp 452–5 [105] Decataldo F et al 2019 Stretchable low impedance”
BackgroundMethodSpatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73 · cited 2×
“12 420 [37] Gaillet V, Cutrone A, Artoni F, Vagni P, Mega Pratiwi A, Romero S A, Paola L D, Micera D and Ghezzi D 2020 Spatially selective activation of the visual cortex via”
BackgroundSelf-citationIn vitro and in vivo mechanical properties of human ulnar and median nerves
Ma, Z., Hu, S., Tan, J. S., Myer, C., Njus, N. M., & Xia, Z. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34573 · Cited by 72 · cited 2×
“[49] Ma Z, Hu S, Tan J S, Myer C, Njus N M and Xia Z 2013 In”
BackgroundChronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70 · cited 2×
“One technique consists in engineering stretchable microcracked interconnects through gold evaporation and has been successfully used to record PN activity in regenerativemicrochannel interfaces [126].”
BackgroundMethodSelf-citationRosso, G., & Guck, J. R. (2019) · APL Bioengineering · doi:10.1063/1.5108867 · Cited by 69 · cited 4×
“Rat—sciatic Linear E = 390 Pa; 131 Pa; 226 Pa AFM indentation [50]”
BackgroundMethodInfluentialDelivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68
Self-citationAn anatomical study of porcine peripheral nerve and its potential use in nerve tissue engineering
Žilić, L., Garner, P. E., Yu, T., Román, S., Haycock, J. W., & Wilshaw, S. (2015) · Journal of Anatomy · doi:10.1111/joa.12341 · Cited by 66 · cited 2×
“[52] Zilic L, Garner P E, Yu T, Roman S, Haycock J W and”
BackgroundBadia, J., Raspopovic, S., Carpaneto, J., Micera, S., & Navarro, X. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2440768 · Cited by 65 · cited 3×
“The latter can be classified into two categories: spatial and functional [62].”
BackgroundSelf-citationKilgard, M. P., Rennaker, R. L., Alexander, J., & Dawson, J. (2018) · Neurorehabilitation · doi:10.3233/nre-172273 · Cited by 65
Riso, R. R., Mosallaie, F. K., Jensen, W., & Sinkjaer, T. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847826 · Cited by 64 · cited 1×
“[39] Riso R R, Mosallaie F K, Jensen W and Sinkjaer T 2000”
BackgroundA computational model to design neural interfaces for lower-limb sensory neuroprostheses
Zelechowski, M., Valle, G., & Raspopovic, S. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00657-7 · Cited by 63
A silicon carbide array for electrocorticography and peripheral nerve recording
Diaz-Botia, C. A., Luna, L. E., Neely, R. M., Chamanzar, M., Carraro, C., Carmena, J. M., Sabes, P. N., Maboudian, R., & Maharbiz, M. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7698 · Cited by 61 · cited 2×
“(BioCAS) (Torino: IEEE) pp 1–4 [210] Diaz-Botia C A, Luna L E, Neely R M, Chamanzar M, Carraro C, Carmena J M, Sabes P N, Maboudian R and Maharbiz MM 2017 A silicon carbide array for electrocorticography and peripheral nerve recording J.”
BackgroundJiman, A. A., Ratze, D. C., Welle, E. J., Patel, P. R., Richie, J. M., Bottorff, E. C., Seymour, J. P., Chestek, C. A., & Bruns, T. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72512-7 · Cited by 61 · cited 2×
“Functional Electrical Stimulation Society pp 265–8 [217] Lee Y J, Kim H-J, Do S H, Kang J Y and Lee S H 2016 Characterization of nerve-cuff electrode interface for biocompatible and chronic stimulating application Sensors Actuators B 237 924–34 [218] Jiman A A, Ratze D C, Welle E J, Patel P R, Richie J M, Bottorff E C…”
Time-Resolved Fast Mammalian Behavior Reveals the Complexity of Protective Pain Responses
Browne, L. E., Latrémolière, A., Lehnert, B. P., Grantham, A., Ward, C., Alexandre, C., Costigan, M., Michoud, F., Roberson, D. P., Ginty, D. D., et al. (2017) · Cell Reports · doi:10.1016/j.celrep.2017.06.024 · Cited by 60
Neural interfaces for regenerated nerve stimulation and recording
Dario, P., Garzella, P., Toro, M., Micera, S., Alavi, M., Meyer, U., Valderrama, E., Sebatiani, L., Ghelarducci, B., Mazzoni, C., et al. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736149 · Cited by 58 · cited 2×
“Additionally, recording is often occurring in the noisy innate environment of the peripheral nerves (PNs), where tiny neural signals may be shadowed bymuscle activity [13, 14] or challenging to capture following PN injury [15, 16].”
BackgroundSelf-citationA shape-memory and spiral light-emitting device for precise multisite stimulation of nerve bundles
Zheng, H., Zhang, Z., Jiang, S., Yan, B., Shi, X., Xie, Y., Huang, X., Yu, Z., Liu, H., Weng, S., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10418-3 · Cited by 58 · cited 16×
“The electrical properties of PNs have been characterized thoroughly also to enable the development of lumped electrical models and therefore realistic FEM simulations.”
BackgroundInfluentialČvančara, P., Boretius, T., López-Álvarez, V. M., Maciejasz, P., Andreu, D., Raspopovic, S., Petrini, F., Micera, S., Granata, G., Fernandez, E., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9a9a · Cited by 58 · cited 4×
“Flexible and stretchable implants, fabricated using thin film technologies or organic polymers, are further susceptible to ROS-mediated corrosion: bridging between electrodes, circuit opening and mechanical cracks are some of the potential issues that can present when using microfabricated implants [87].”
BackgroundSelf-citationThe role of growth factors in nerve regeneration
Önger, M. E., Delibaş, B., Türkmen, A. P., Erener, E., Altunkaynak, B. Z., & Kaplan, S. (2016) · Drug Discoveries & Therapeutics · doi:10.5582/ddt.2016.01058 · Cited by 57 · cited 2×
“[193] Önger M E, Delibaş B, Türkmen A P, Erener E,”
BackgroundCaravaca, A. S., Tsaava, T., Goldman, L., Silverman, H., Riggott, G., Chavan, S. S., Bouton, C., Tracey, K. J., Desimone, R., Boyden, E. S., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7a42 · Cited by 57 · cited 2×
“[134] Caravaca A S et al 2017 A novel flexible cuff-like”
BackgroundPolyimide micro-channel arrays for peripheral nerve regenerative implants
Lacour, S. P., Atta, R., FitzGerald, J. J., Blamire, M., Tarte, E., & Fawcett, J. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.05.031 · Cited by 56
Self-citationWallman, L., Zhang, Y., Laurell, T., & Danielsen, N. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00342-2 · Cited by 55 · cited 2×
“However, the natural disposition of regenerating neurons to avoid the implant walls often limits intimate electrode-axon contact or proximity [124].”
BackgroundHigh Density, Double-Sided, Flexible Optoelectronic Neural Probes With Embedded μLEDs
Reddy, J. W., Kimukin, I., Stewart, L. T., Ahmed, Z., Barth, A. L., Towe, E., & Chamanzar, M. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00745 · Cited by 55
Neural signal recording and processing in somatic neuroprosthetic applications. A review
Raspopović, S., Cimolato, A., Panarese, A., Vallone, F., del Valle, J., Micera, S., & Navarro, X. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108653 · Cited by 55 · cited 3×
“Less invasive solutions are typically able to record compound APs from large myelinated fibers, while more invasive ones are required to detect the activity of small unmyelinated fibers [26].”
BackgroundInfluentialSelf-citationMotor neuron activation in peripheral nerves using infrared neural stimulation
Peterson, E. J., & Tyler, D. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016001 · Cited by 54 · cited 1×
“[164] Peterson E J and Tyler D J 2014 Motor neuron activation in”
BackgroundLee, Y. J., Kim, H.-J., Do, S. H., Kang, J. Y., & Lee, S. H. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.06.169 · Cited by 54 · cited 2×
“Functional Electrical Stimulation Society pp 265–8 [217] Lee Y J, Kim H-J, Do S H, Kang J Y and Lee S H 2016 Characterization of nerve-cuff electrode interface for biocompatible and chronic stimulating application Sensors Actuators B 237 924–34 [218] Jiman A A, Ratze D C, Welle E J, Patel P R, Richie J M, Bottorff E C…”
BackgroundThe design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54 · cited 2×
“A variation of the FINE, the composite FINE (C-FINE) employs a combination of flexible materials, silicone and a layer of polyether ether ketone (PEEK), to modulate the device stiffness in different locations, flattening the nerve along its width and maintaining flexibility along its length [215].”
BackgroundMethodDali, M., Rossel, O., Andreu, D., Laporte, L., Hernandez, A. I., Laforêt, J., Marijon, É., Hagège, A. A., Clerc, M., Henry, C., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aabeb9 · Cited by 54 · cited 2×
“For example, FEM models have shown the effect of different electrode configurations and recording modalities on the reduction of artifacts derived from external sources such as muscles [72, 73].”
BackgroundSchiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53
Rosso, G., Liashkovich, I., Gess, B., Young, P., Kun, A., & Shahin, V. (2014) · Scientific Reports · doi:10.1038/srep07286 · Cited by 52 · cited 1×
“[59] Rosso G, Liashkovich I, Gess B, Young P, Kun A and”
BackgroundFibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff
Schuettler, M., Donaldson, N., Seetohul, V., & Taylor, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036016 · Cited by 50 · cited 2×
“For example, the velocity of a signal can be extrapolated from multiple electrodes along the length of the nerve and can then be used to discriminate the different source fibers [69, 70].”
BackgroundImpact of Peripheral Nerve Injury on Sensorimotor Control
Duff, S. (2005) · Journal of Hand Therapy · doi:10.1197/j.jht.2005.02.007 · Cited by 50
Conductive Hydrogel Electrodes for Delivery of Long-Term High Frequency Pulses
Staples, N. A., Goding, J. A., Gilmour, A. D., Aristovich, K. Y., Byrnes-Preston, P., Holder, D. S., Morley, J. W., Lovell, N. H., Chew, D. J., & Green, R. A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00748 · Cited by 50
A guide towards long-term functional electrodes interfacing neuronal tissue
Renz, A. F., Reichmuth, A. M., Stauffer, F., Thompson-Steckel, G., & Vörös, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae0c2 · Cited by 50 · cited 2×
“[86] Renz A F, Reichmuth A M, Stauffer F, Thompson-Steckel G”
BackgroundLemaire, T., Neufeld, E., Kuster, N., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab1685 · Cited by 50 · cited 2×
“The fundamental mechanism through which ultrasounds interact with neural tissue is still unclear, with most theories being explored either through modelling [154] or acute experiments on exposed nerves [155, 156], which have often provided conflicting results.”
BackgroundSelf-citationRomero, E., Denef, J. F., Delbeke, J., Robert, A., & Veraart, C. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345271 · Cited by 49 · cited 2×
“[214] Romero E, Denef J F, Delbeke J, Robert A and Veraart C”
BackgroundRegenerated sciatic nerve axons stimulated through a chronically implanted macro-sieve electrode
MacEwan, M. R., Zellmer, E. R., Wheeler, J. J., Burton, H., & Moran, D. W. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00557 · Cited by 48 · cited 2×
“Multiple configurations have been exposed in literature, using perforated arrays [15, 119, 120] and slotted structures [121].”
BackgroundMaterial considerations for peripheral nerve interfacing
Kim, Y.-T., & Romero-Ortega, M. I. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.99 · Cited by 47
Challenges associated with nerve conduction block using kilohertz electrical stimulation
Patel, Y., & Butera, R. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaadc0 · Cited by 47 · cited 2×
“14 375–85 [67] Patel Y A and Butera R J 2018 Challenges associated with nerve conduction block using kilohertz electrical stimulation J.”
BackgroundMethodLabel-free optical detection of bioelectric potentials using electrochromic thin films
Alfonso, F. S., Zhou, Y. P., Liu, E., McGuire, A. F., Yang, Y., Kantarci, H., Li, D., Copenhaver, E., Zuchero, J. B., Müller, H., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2002352117 · Cited by 47
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46 · cited 2×
“To increase the number of addressable electrodes for recording and stimulation, sieves have been also integrated with analog multiplexers [122].”
BackgroundCarnicer-Lombarte (2019) · doi:10.1101/829648 · Cited by 46 · cited 4×
“[58] Carnicer-Lombarte A et al 2019 Mechanical matching of”
BackgroundInfluentialInsulation lifetime improvement of polyimide thin film neural implants
Ceyssens, F., & Puers, R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/054001 · Cited by 45 · cited 2×
“[208] Ceyssens F and Puers R 2015 Insulation lifetime”
BackgroundPERIPHERAL NERVE AND LOCAL ANAESTHETIC DRUGS
Wildsmith, J. A. W. (1986) · British Journal of Anaesthesia · doi:10.1093/bja/58.7.692 · Cited by 44
Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
Restaino, S. M., Abliz, E., Wachrathit, K., Krauthamer, V., & Shah, S. B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-73 · Cited by 44 · cited 2×
“[90] Restaino S M, Abliz E, Wachrathit K, Krauthamer V and”
BackgroundStable Detection of Movement Intent From Peripheral Nerves: Chronic Study in Dogs
Dweiri, Y. M., Eggers, T. E., Gonzalez-Reyes, L. E., Drain, J., McCallum, G. A., & Durand, D. M. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2607520 · Cited by 44 · cited 2×
“FINE devices of different sizes and electrode configurations have been successfully used chronically in a wide range of animals [30, 99, 100] and also in humans [101–103], both to stimulate and record the activity of PNs.”
BackgroundDevelopment of the thin-film longitudinal intra-fascicular electrode
Yoshida, K., Pellinen, D. S., Pivin, D. P., Rousche, P. J., & Kipke, D. R. (2000) · Cited by 44
Jowett, N., Kearney, R. E., Knox, C., & Hadlock, T. A. (2018) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000005164 · Cited by 44
Lee, J., Ko, K., Shin, H., Oh, S.-J., Lee, C. J., Chou, N., Choi, N., Tack Oh, M., Chul Lee, B., Chan Jun, S., et al. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0070-5 · Cited by 44
Fascicle specific targeting for selective peripheral nerve stimulation
Overstreet, C. K., Cheng, J., & Keefer, E. W. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4370 · Cited by 44 · cited 2×
“However, the implantation procedure appears to be more complicated with respect to other standard devices, requiring careful excision of the epineurium and clipping of the cuff around smaller and more fragile individual fascicles [130].”
BackgroundChronic histological effects of the flat interface nerve electrode
Leventhal, D. K., Cohen, M., & Durand, D. M. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/004 · Cited by 43 · cited 1×
“[228] Leventhal D K, Cohen M and Durand D M 2006 Chronic”
BackgroundCobo, A. M., Larson, C. E., Scholten, K., Miranda, J. A., Elyahoodayan, S., Song, D., Pikov, V., & Meng, E. (2019) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2018.2881908 · Cited by 43 · cited 4×
“A common method for drug delivery in flexible chemical PNIs consists in fabricating microfluidic channels on cuff electrodes [173, 178, 186] which can then be connected to external syringe pumps [186] to provide pharmacological treatment over time.”
BackgroundMethodInfluentialKoch, J., Schuettler, M., Pasluosta, C., & Stieglitz, T. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab36df · Cited by 43 · cited 2×
“[91] Koch J, Schuettler M, Pasluosta C and Stieglitz T 2019”
Backgrounddel Valle, J., de la Oliva, N., Muller, M., Stieglitz, T., & Navarro, X. (2015) · 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2015.7146654 · Cited by 42 · cited 21×
“Sections 4.2 and 5.2 are dedicated to the strategies to reduce the FBR through different interactionmechanisms, drug eluting devices and soft biocompatible materials.”
BackgroundInfluentialTransdermal optogenetic peripheral nerve stimulation
Maimon, B. E., Zorzos, A. N., Bendell, R., Harding, A., Fahmi, M., Srinivasan, S., Calvaresi, P., & Herr, H. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5e20 · Cited by 42 · cited 1×
“[145] Maimon B E, Zorzos A N, Bendell R, Harding A, Fahmi M,”
BackgroundPark, S. J., Lee, Y. J., Heo, D. N., Kwon, I. K., Yun, K., Kang, J. Y., & Lee, S. H. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.03.036 · Cited by 41 · cited 3×
“Alternatively, hydrogel-based [174] or nanofiber-based [194] drug-loaded coatings have been used, allowing a controlled release in a fixed”
BackgroundMethodInfluentialMechanical functioning of peripheral nerves: linkage with the “mushrooming” effect
Walbeehm, E. T., Afoke, A., de Wit, T., Holman, F. A., Hovius, S. E. R., & Brown, R. A. (2004) · Cell and Tissue Research · doi:10.1007/s00441-004-0867-9 · Cited by 41
Boretius, T., Yoshida, K., Badia, J., Harreby, K., Kundu, A., Navarro, X., Jensen, W., & Stieglitz, T. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290787 · Cited by 39 · cited 2×
“The transversal intraneural multichannel electrode (TIME) design is inspired by the tf-LIFE except for the implantation direction, that is perpendicular with respect to the nerve’s orientation [114].”
BackgroundMethodOptical cuff for optogenetic control of the peripheral nervous system
Michoud, F., Sottas, L., Browne, L. E., Asboth, L., Latremoliere, A., Sakuma, M., Courtine, G., Woolf, C. J., & Lacour, S. P. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9126 · Cited by 39 · cited 22×
“Sections 4.2 and 5.2 are dedicated to the strategies to reduce the FBR through different interactionmechanisms, drug eluting devices and soft biocompatible materials.”
BackgroundInfluentialSelf-citationMain, E. K., Goetz, J. E., Rudert, M., et al. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.12.005 · Cited by 38 · cited 3×
“Viscoelasticity and hyperelasticity models offer a more accurate view of the nerve mechanics [48, 49].”
BackgroundRecent Progress of Development of Optogenetic Implantable Neural Probes
Zhao, H. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18081751 · Cited by 38 · cited 6×
“For applications in the CNS, these limitations have been partially overcome by fabricating thin film GaN microLEDs [180, 181], while similar approaches remain to be tested in the PNS.”
BackgroundInfluentialFeasibility of inducing micturition through chronic stimulation of sacral roots
Schmidt, R. A., Bruschini, H., & Tanagho, E. A. (1978) · Urology · doi:10.1016/0090-4295(78)90309-6 · Cited by 37
Transverse elasticity and blood perfusion of sciatic nerves under in situ circular compression
Ju, M., Lin, C. K., Fan, J.-L., & Chen, R.-J. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.10.026 · Cited by 37 · cited 3×
“B 17 155–64 [46] Ju M-S, Lin -C-C K, Fan J-L and Chen R-J 2006 Transverse elasticity and blood perfusion of sciatic nerves under in situ circular compression J.”
BackgroundMetcalfe, B., Nielsen, T. N., Donaldson, N., Hunter, A. J., & Taylor, J. T. (2017) · Biomedical Engineering Letters · doi:10.1007/s13534-017-0054-z · Cited by 37 · cited 2×
“[69] Metcalfe B W, Nielsen T N, Donaldson N D N, Hunter A J”
BackgroundFeng, B., Chen, L., & Ilham, S. J. (2019) · Applied Sciences · doi:10.3390/app9081637 · Cited by 37 · cited 1×
“(BioCAS) pp 1–4 [137] Feng B, Chen L and Ilham S J 2019 A review on ultrasonic neuromodulation of the peripheral nervous system: enhanced or suppressed activities? Appl.”
BackgroundAll-Optical Detection of Neuronal Membrane Depolarization in Live Cells Using Colloidal Quantum Dots
Çaǧlar, M., Pandya, R., Xiao, J., Foster, S. K., Divitini, G., Chen, R. Y. S., Greenham, N. C., Franze, K., Rao, A., & Keyser, U. F. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b03026 · Cited by 37 · cited 2×
“117 17260–8 [246] Caglar M, Pandya R, Xiao J, Foster S K, Divitini G, Chen R Y S, Greenham N C, Franze K, Rao A and Keyser U F 2019 All-optical detection of neuronal membrane depolarization in live cells using colloidal quantum dots Nano Lett.”
BackgroundMethodElectrical Stimulation as Treatment for Obesity and Diabetes
Greenway, F. L., & Zheng, J. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100216 · Cited by 35 · cited 1×
“Content 215 560–8 [4] Greenway F and Zheng J 2007 Electrical stimulation as treatment for obesity and diabetes J.”
BackgroundFascicular nerve stimulation and recording using a novel double-aisle regenerative electrode
Delgado-Martínez, I., Righi, M., Santos, D., Cutrone, A., Bossi, S., D’Amico, S., Del Valle, J., Micera, S., & Navarro, X. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6bac · Cited by 35 · cited 4×
“As fibers regrow, electrodes can pick-up their activity [123].”
BackgroundInfluentialSelf-citationA Respiratory Marker Derived From Left Vagus Nerve Signals Recorded With Implantable Cuff Electrodes
Sevcencu, C., Nielsen, T. N., Kjærgaard, B., & Struijk, J. J. (2017) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12630 · Cited by 35 · cited 2×
“Lastly, recordings from autonomic nerves can give insight on the body’s internal state and may act as biomarkers for different pathologies: activity from the vagus nerve has been shown to be correlated with respiratory cycle and blood pressure [41, 42], while metabolic information derived from the carotid sinus nerve…”
BackgroundAckermann, D. M., Foldes, E. L., Bhadra, N., et al. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.043 · Cited by 34 · cited 3×
“One primary concern relates to the possible damage to neural tissue which would derive from long-term use of heating or cooling strategies [138].”
BackgroundInfluentialCha, J., Broch, A., Mudge, S., Kim, K., Namgoong, J., Oh, E., & Kim, P. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.001097 · Cited by 34 · cited 1×
“41 20–28 [28] Cha J, Broch A, Mudge S, Kim K, Namgoong J-M, Oh E”
BackgroundDecoding Neural Metabolic Markers From the Carotid Sinus Nerve in a Type 2 Diabetes Model
Cracchiolo, M., Sacramento, J. F., Mazzoni, A., Panarese, A., Carpaneto, J., Conde, S. V., & Micera, S. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2942398 · Cited by 34 · cited 2×
“Lastly, recordings from autonomic nerves can give insight on the body’s internal state and may act as biomarkers for different pathologies: activity from the vagus nerve has been shown to be correlated with respiratory cycle and blood pressure [41, 42], while metabolic information derived from the carotid sinus nerve…”
BackgroundSelf-citationMechanically Robust, Softening Shape Memory Polymer Probes for Intracortical Recording
Stiller, A. M., Usoro, J. O., Lawson, J. M., Araya, B., González‐González, M. A., Danda, V. R., Voit, W., Black, B., & Pancrazio, J. J. (2020) · Micromachines · doi:10.3390/mi11060619 · Cited by 32
Automated reactive accelerated aging for rapid in vitro evaluation of neural implant performance
Street, M. G., Welle, C. G., & Takmakov, P. A. (2018) · Review of Scientific Instruments · doi:10.1063/1.5024686 · Cited by 31
Cuff electrodes for very small diameter nerves — Prototyping and first recordings in vivo
Ordonez, J. S., Pikov, V., Wiggins, H., Patten, C., Stieglitz, T., Rickert, J., & Schuettler, M. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6945201 · Cited by 30
Shape Memory Alloy Microactuation of tf-LIFEs: Preliminary Results
Bossi, S., Menciassi, A., Koch, K. P., Hoffmann, K.-P., Yoshida, K., Dario, P., & Micera, S. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895186 · Cited by 29 · cited 2×
“[113] Bossi S, Menciassi A, Koch K P, Hoffmann K-P, Yoshida K, Dario P and Micera S 2007 Shape memory alloy microactuation of tf-LIFEs: preliminary results IEEE Trans.”
BackgroundMethodSelf-citationEvaluation of high-density, multi-contact nerve cuffs for activation of grasp muscles in monkeys
Brill, N. A., Naufel, S. N., Polasek, K., Ethier, C., Cheesborough, J., Agnew, S., Miller, L. E., & Tyler, D. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8735 · Cited by 28 · cited 2×
“FINE devices of different sizes and electrode configurations have been successfully used chronically in a wide range of animals [30, 99, 100] and also in humans [101–103], both to stimulate and record the activity of PNs.”
BackgroundXue, N., Delgado-Martínez, I., Sun, J., Cheng, Y., & Liu, C. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.04.043 · Cited by 27
Song, K., Park, S. E., Lee, S., Kim, H., Lee, S. H., & Youn, I. (2018) · Scientific Reports · doi:10.1038/s41598-018-33695-2 · Cited by 27
Increased stiffness of median nerve in systemic sclerosis
Yağcı, İ., Keniş-Coşkun, Ö., Özsoy, T., Özen, G., & Direskeneli, H. (2017) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-017-1793-9 · Cited by 25 · cited 2×
“[51] Yagci I, Kenis-Coskun O, Ozsoy T, Ozen G and Direskeneli”
BackgroundMethodElyahoodayan, S., Larson, C., Cobo, A. M., Meng, E., & Song, D. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108634 · Cited by 25 · cited 2×
“6 26910 [196] Elyahoodayan S, Larson C, Cobo A M, Meng E and Song D 2020 Acute in vivo testing of a polymer cuff electrode with integrated microfluidic channels for stimulation, recording, and drug delivery on rat sciatic nerve J.”
BackgroundFinite element modeling of hyper-viscoelasticity of peripheral nerve ultrastructures
Chang, C., Chen, Y.-H., Lin, C. K., & Ju, M. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.04.004 · Cited by 24 · cited 2×
“4 Compressive [57] Rat—sciatic Linear E = 140 Pa AFM indentation [58] Endoneurium Rat—sciatic Ogden μ= 55 kPa, α= 6.”
BackgroundTian, H., Liu, J.-Q., Kang, X.-Y., Tang, L.-J., Wang, M.-H., Bo-Wen, J., Yang, B. T., Wang, X. L., Chen, X., & Yang, C.-S. (2016) · Scientific Reports · doi:10.1038/srep26910 · Cited by 24 · cited 2×
“Concurrent electrophysiological recording from microelectrodes integrated with a drug delivery outlet allows for in situ verification of nerve blocking effects [195].”
BackgroundA neural blood pressure marker for bioelectronic medicines for treatment of hypertension
Sevcencu, C., Nielsen, T. N., & Struijk, J. J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.06.031 · Cited by 24 · cited 2×
“Lastly, recordings from autonomic nerves can give insight on the body’s internal state and may act as biomarkers for different pathologies: activity from the vagus nerve has been shown to be correlated with respiratory cycle and blood pressure [41, 42], while metabolic information derived from the carotid sinus nerve…”
BackgroundMayer, P., Sivakumar, N., Pritz, M., Varga, M., Mehmann, A., Lee, S., Salvatore, A., Magno, M., Pharr, M., Johannssen, H. C., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00819 · Cited by 24 · cited 2×
“Currently only one solution of this kind has been proposed in the PNS, using negative temperature coefficient components [175], which are rigid and bulky, significantly affecting the overall thickness and flexibility of the device.”
BackgroundUltra-thin biocompatible implantable chip for bidirectional communication with peripheral nerves
de Beeck, M. O., Verplancke, R., Schaubroeck, D., Cuypers, D., Cauwe, M., Vandecasteele, B., O'Callaghan, J. M., Braeken, D., Andrei, A., Firrincieli, A., et al. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325206 · Cited by 21 · cited 2×
“These can be deposited through atomic layer deposition, and further capped by an additional inorganic layer, such as HfO2, to limit issues related towater hydrolysis of alumina [209].”
BackgroundDevelopment of an active high-density transverse intrafascicular micro-electrode probe
Verplancke, R., Cauwe, M., Schaubroeck, D., Cuypers, D., Vandecasteele, B., Mader, L., Vanhaverbeke, C., Ballini, M., O’Callaghan, J., Goikoetxea, E., et al. (2020) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab5df2 · Cited by 21 · cited 2×
“[117] Verplancke R et al 2019 Development of an active”
BackgroundMethodSrinivasan, A., Tipton, J., Tahilramani, M., Kharbouch, A., Gaupp, E., Song, C., Venkataraman, P., Falcone, J., Lacour, S. P., Stanley, G. B., et al. (2016) · European Journal of Neuroscience · doi:10.1111/ejn.13080 · Cited by 20 · cited 1×
“[128] Srinivasan A et al 2016 A regenerative microchannel device”
Self-citationConduction block of mammalian myelinated nerve by local cooling to 15–30°C after a brief heating
Zhang, Z., Lyon, T. D., Kadow, B. T., Shen, B. Q., Wang, J., Lee, A., Kang, A., Roppolo, J. R., de Groat, W. C., & Tai, C. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00954.2015 · Cited by 20 · cited 1×
“Methods 193 72–76 [139] Zhang Z, Lyon T D, Kadow B T, Shen B, Wang J, Lee A, Kang A, Roppolo J R, de Groat W C and Tai C 2016 Conduction block of mammalian myelinated nerve by local cooling to 15–30◦C after a brief heating J.”
Background
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
“Although long-term nerve implants are feasible 103,114,195,231–234 and promising for versatile clinical and home uses 96,235 , their wider clinical translation will require substantial developments regarding device stability, their integration into fully implantable systems, and the modularity of…”
BackgroundSelf-citationBioadhesive Technology Platforms
Wu, S. J., & Zhao, X. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00380 · Cited by 218
“450 Poor control over cooling can pose the risk of cold nerve injury, underscoring the importance of achieving proper nerve integration.”
BackgroundHighly-stable, injectable, conductive hydrogel for chronic neuromodulation
Yang, M., Wang, L., Liu, W., Li, W., Huang, Y., Jin, Q., Zhang, L., Jiang, Y., & Luo, Z. (2024) · Nature Communications · doi:10.1038/s41467-024-52418-y · Cited by 143
Electrochemically actuated microelectrodes for minimally invasive peripheral nerve interfaces
Dong, C., Carnicer‐Lombarte, A., Bonafè, F., Huang, B., Middya, S., Jin, A. T., Tao, X., Han, S., Bance, M., Barone, D. G., et al. (2024) · Nature Materials · doi:10.1038/s41563-024-01886-0 · Cited by 133
“A mixed aqueous solution containing 0.1 M pyrrole and 0.1 M NaDBS was used as the electrolyte.”
InfluentialYang, M., Chen, P., Qu, X., Zhang, F., Ning, S., Ma, L., YANG, K. Y., Su, Y., Zang, J., Jiang, W., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c04606 · Cited by 109
Metadata
- Authors
- Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Scuola Superiore Sant'Anna (IT)
- Corresponding author
- Micera, Silvestro
- Lacour, Stéphanie P
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2021-03-08
- Volume
- 18
- Issue
- 3
- Pages
- 031001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3137684282
- Cited by
- 60
- References
- 253
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 16 · 2023: 11 · 2022: 14 · 2021: 5
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- Fondation Bertarelli
- Horizon 2020 Framework Programme (NeuTouch 813713)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (CHRONOS)
- H2020 Marie Skłodowska-Curie Actions (754354)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- peripheral nerve interfaces, implantable neural interfaces, flexible electronics, biocompatibility, foreign body reaction, neural recording, neurostimulation, optical stimulation, chemical stimulation, implant-tissue interface, neuroprosthetics, neuropathic pain
- MeSH terms
- Neurosciences, Peripheral Nerves, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.