Compliant peripheral nerve interfaces.
Open accessThe DOI matches its Crossref record; 247 of the 253 references it cites were found in a registry or an index; none of the 3 sources its claims cite is checked for support yet.
Abstract
This paper reviews recent progress in the development of flexible and implantable PNIs, highlighting materials selection, fabrication methods, and interface designs.
Overview
CoChat Summary
TL;DR
This topical review surveys recent progress in mechanically compliant peripheral nerve interfaces (PNIs), focusing on materials, fabrication, and integrated functions for flexible implantable systems. It argues that long-term PNI performance is limited by implant–tissue damage and foreign body response, and that compliance is a key strategy to improve chronic function.
Key findings
- PNIs are used for both research and therapy, including closed-loop control of neuroprosthetic limbs, treatment of neuropathic pain, and restoration of functions such as breathing and bladder management.
- The review highlights three main interface classes: intraneural, extraneural, and regenerative, and three modulation modalities: electrical, optical, and chemical.
- A central challenge is that implantable PNIs can provide enhanced selectivity over non-invasive approaches, but their long-term functionality is limited by tissue damage at the implant–tissue interface.
- The paper emphasizes that compliant PNIs are designed to match nerve anatomy and dynamic motion in order to limit foreign body response.
Methods
- Topical review article: the paper synthesizes recent literature rather than reporting a new experimental study.
- Scope of the review covers flexible and implantable PNIs, with attention to materials selection, fabrication methods, integrated functions, and interface design categories.
- Main analysis is qualitative and comparative, discussing design trade-offs and challenges in integrating PNIs on compliant substrates.
Limitations
- The paper does not present original experimental data or a quantitative meta-analysis; this is evident from the text as a review article.
- It states that long-term functionality remains limited by tissue damage and implant–tissue interface issues, indicating an unresolved design limitation.
- The text makes clear that integrating electrical, optical, and chemical functions on compliant substrates remains challenging.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 2 Not valid · 2 Not checked · 5 Own results and interpretations
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Nevertheless, the long-term functionality of implantable PNIs is limited by tissue damage, which occurs at the implant–tissue interface”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim have been checked yet.
In the paper
“challenging to capture following PN injury [15, 16]”
What the sources say
- Not checked yetcites [15] Navarro, 1998, Stimulation and recording from regenerated peripheral nerves through polyimide sieve electrodes, J. Peripher. Nerv. Syst.
- Not checked — no full text of the sourcecites [16] Dario, 1998, Neural interfaces for regenerated nerve stimulation and recording, IEEE Trans. Rehabil. Eng. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
1 reference still to check
A free account verifies the references that are still open.
- Probably not a substantial claim. 7
- It may state two separate claims as one. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Neuromodulation of the autonomic nerves, which regulates non-volitional bodily processes such as those of the cardiovascular, gastrointestinal, and immune systems, has shown therapeutic benefits in diseases including heart failure, lung injury, inflammation, rheumatoid arthritis, obesity, and diabetes [11], [12].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [12]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Recently, interfascicular interfaces were called the 'least common in literature' [47].”
From Directed stimulation with interfascicular interfaces for peripheral nerve stimulation (2021) · cites this paper as [47]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Patientspecific methods of addressing the peripheral nerves require close inspection of neural activity to optimise the position of electrodes [12], the stimulation algorithm, and analysis methods of neural activity according to the individual needs of patients [218].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [12]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“This improves longevity by addressing interface compromising factors such as the foreign body reaction, which can deteriorate the neural interface and isolate the nerve fibers through scarring [12], [206].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [12]
Experimental — accuracy not yet measured
Citations
Cites
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861 · cited 2×
“Specifically, when designing optical interfaces for optogenetics, it is necessary to ensure a minimum irradiance in the range of 1–5 mW mm−2 to target fibers [183, 184].”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 2×
“Electrical stimulation also contributes to the degradation of metallic electrodes, as non-reversible electrochemical reactions may occur when injecting high currents [88, 89].”
BackgroundCurrent Problems of Lower Vertebrate Phylogeny
Romanes, G. J. (1969) · Journal of Anatomy · Cited by 1,830
The stiffness of living tissues and its implications for tissue engineering
Guimarães, C. F., Gasperini, L., Marques, A. P., & Reis, R. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0169-1 · Cited by 1,515 · cited 2×
“PNs are heterogeneous anisotropic structures and, similarly to other tissues in the body [44], they display highly nonlinear and viscoelastic properties, stiffening at large strains, and they present stress relaxation behaviour when stretched.”
BackgroundMechanisms of neuropathic pain
Campbell, J. N., & Meyer, R. A. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.021 · Cited by 1,471
Guyton and Hall: Textbook of Medical Physiology
Khonsary, S. (2017) · Surgical Neurology International · doi:10.4103/sni.sni_327_17 · Cited by 1,394 · cited 2×
“and function have been shown to be strictly correlated [24, 25] (figure 2(c)).”
BackgroundKoopman, F. A., Chavan, S. S., Miljko, S., Grazio, S., Sokolovic, S., Schuurman, P. R., Mehta, A. D., Levine, Y. A., Faltys, M., Zitnik, R., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605635113 · Cited by 1,024 · cited 2×
“[32] Koopman F A et al 2016 Vagus nerve stimulation inhibits”
BackgroundRestoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 2×
“[205] Raspopovic S et al 2014 Restoring natural sensory feedback”
BackgroundSelf-citationAravanis, A. M., Wang, L.-P., Zhang, F., Meltzer, L. A., Mogri, M. Z., Schneider, M. B., & Deisseroth, K. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s02 · Cited by 970 · cited 6×
“For applications in the CNS, these limitations have been partially overcome by fabricating thin film GaN microLEDs [180, 181], while similar approaches remain to be tested in the PNS.”
BackgroundInfluentialCONDUCTION VELOCITY AND DIAMETER OF NERVE FIBERS
Hursh, J. B. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.131 · Cited by 916
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
“Although long-term nerve implants are feasible 103,114,195,231–234 and promising for versatile clinical and home uses 96,235 , their wider clinical translation will require substantial developments regarding device stability, their integration into fully implantable systems, and the modularity of…”
BackgroundSelf-citationBioadhesive Technology Platforms
Wu, S. J., & Zhao, X. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00380 · Cited by 218
“450 Poor control over cooling can pose the risk of cold nerve injury, underscoring the importance of achieving proper nerve integration.”
BackgroundHighly-stable, injectable, conductive hydrogel for chronic neuromodulation
Yang, M., Wang, L., Liu, W., Li, W., Huang, Y., Jin, Q., Zhang, L., Jiang, Y., & Luo, Z. (2024) · Nature Communications · doi:10.1038/s41467-024-52418-y · Cited by 143
Electrochemically actuated microelectrodes for minimally invasive peripheral nerve interfaces
Dong, C., Carnicer‐Lombarte, A., Bonafè, F., Huang, B., Middya, S., Jin, A. T., Tao, X., Han, S., Bance, M., Barone, D. G., et al. (2024) · Nature Materials · doi:10.1038/s41563-024-01886-0 · Cited by 133
“A mixed aqueous solution containing 0.1 M pyrrole and 0.1 M NaDBS was used as the electrolyte.”
InfluentialYang, M., Chen, P., Qu, X., Zhang, F., Ning, S., Ma, L., YANG, K. Y., Su, Y., Zang, J., Jiang, W., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c04606 · Cited by 109
4D‐Printed Soft and Stretchable Self‐Folding Cuff Electrodes for Small‐Nerve Interfacing
Hiendlmeier, L., Zurita, F., Vogel, J., Duca, F. D., Boustani, G. A., Hu, P., Kopic, I., Nikić, M., Teshima, T., & Wolfrum, B. L. (2023) · Advanced Materials · doi:10.1002/adma.202210206 · Cited by 75
Stretchable gold nanowire-based cuff electrodes for low-voltage peripheral nerve stimulation
Lienemann, S., Zötterman, J., Farnebo, S., & Tybrandt, K. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abfebb · Cited by 48
“The Young’s modulus of a flexible cuff electrode is typically in the GPa range, which is more than three orders of magnitude higher than reported values for peripheral nerves (typically 40 kPa–20 MPa, nerves are however heterogeneous anisotropic structures of a hyperelastic nature) [7, 29, 30].”
BackgroundAdvances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44
Rezza, A. S., Külahçı, Y., Gorantla, V. S., Zor, F., & Drzeniek, N. M. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.863969 · Cited by 51
“2 Neural Interfaces Peripheral nerve interfaces’ primary function is to interrogate or actuate the peripheral nervous system with electrode arrays for applications such as neuropathic pain management, nerve recording for limb prosthetics or replacement of peripheral nerve function for bladder control, as reviewed by P…”
BackgroundInfluentialWang, L., Zhang, T., Lei, J., Wang, S., Guan, Y., Chen, K., Li, C., Song, Y., Li, W., Wang, S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-56089-1 · Cited by 63
Perspectives on tissue-like bioelectronics for neural modulation
Sun, C., Cheng, Z., Abu-Halimah, J., & Tian, B. (2023) · iScience · doi:10.1016/j.isci.2023.106715 · Cited by 40
Non-invasive electrical stimulation of peripheral nerves for the management of tremor
Valdunciel, A. P., Rajagopal, A., Pons, J. L., & Delp, S. L. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120195 · Cited by 38
Modulus‐Tailorable, Stretchable, and Biocompatible Carbonene Fiber for Adaptive Neural Electrode
Gong, Q., Yu, Y., Kang, L., Zhang, M., Zhang, Y., Wang, S., Niu, Y., Zhang, Y., Di, J., Li, Q., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202107360 · Cited by 31
A soft, scalable and adaptable multi-contact cuff electrode for targeted peripheral nerve modulation
Paggi, V., Fallegger, F., Serex, L., Rizzo, O., Galan, K., Giannotti, A., Furfaro, I., Zinno, C., Bernini, F., Micera, S., et al. (2024) · Bioelectronic Medicine · doi:10.1186/s42234-023-00137-y · Cited by 35
“Extraneural cuff electrodes are widely considered the safest yet least selective among implantable nerve interfaces (Paggi et al. 2021).”
BackgroundMethodInfluentialSelf-citationStretchable Tissue‐Like Gold Nanowire Composites with Long‐Term Stability for Neural Interfaces
Seufert, L., ElMahmoudy, M., Theunis, C., Lienemann, S., Li, Y., Mohammadi, M., Boda, U., Carnicer‐Lombarte, A., Kroon, R., Persson, P. O. Å., et al. (2024) · Small · doi:10.1002/smll.202402214 · Cited by 26
Physical cues of scaffolds promote peripheral nerve regeneration
Cao, W., Zhang, Y., Li, L., Liu, B., Ding, J., & Chen, X. (2024) · Applied Physics Reviews · doi:10.1063/5.0189181 · Cited by 24
Koppaka, S., Hess‐Dunning, A., & Tyler, D. J. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111058 · Cited by 21
A Soft and Stretchable Multielectrode Cuff for Selective Peripheral Nerve Stimulation
Lienemann, S., Donahue, M. J., Zötterman, J., Farnebo, S. J., & Tybrandt, K. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201322 · Cited by 23
Conformable neural interface based on off-stoichiometry thiol-ene-epoxy thermosets
Borda, E., Medagoda, D. I., Leccardi, M. J. I. A., Zollinger, E. G., & Ghezzi, D. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121979 · Cited by 20
Challenges and opportunities in flexible, stretchable and morphable bio-interfaced technologies
Vázquez‐Guardado, A., Yang, Y., & Rogers, J. A. (2022) · National Science Review · doi:10.1093/nsr/nwac016 · Cited by 19
Andreis, F. R., Metcalfe, B., Janjua, T. A. M., Jensen, W., Meijs, S., & Nielsen, T. N. (2021) · Sensors · doi:10.3390/s22010058 · Cited by 13
Gregory, E., Baek, I., Ala-Kokko, N., Dugan, R., Pinzon‐Herrera, L., Almodóvar, J., & Song, Y. H. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00034 · Cited by 14
Riva, E. R., Pérez‐Izquierdo, M., Zinno, C., Contreras, E., Rodríguez‐Meana, B., Iberite, F., Ricotti, L., Micera, S., & Navarro, X. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202300136 · Cited by 13
Self-citationBorda, E., Gaillet, V., Airaghi Leccardi, M. J. I., Zollinger, E. G., Moreira, R. C., & Ghezzi, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6d7e · Cited by 11
“Spatial selectivity in neuromodulation refers to interacting with neurons in a predefined and limited volume of tissue [36].”
BackgroundSingle-interface bioelectronic medicines—concept, clinical applications and preclinical data
Sevcencu, C. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6e08 · Cited by 14
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“This improves longevity by addressing interface compromising factors such as the foreign body reaction, which can deteriorate the neural interface and isolate the nerve fibers through scarring [12], [206].”
Spatio-temporal feature extraction in sensory electroneurographic signals
Silveira, C. R. A., Khushaba, R. N., Brunton, E., & Nazarpour, K. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0268 · Cited by 8
Taghlabi, K. M., Cruz-Garza, J. G., Hassan, T., Potnis, O., Bhenderu, L. S. S., Guerrero, J. R., Whitehead, R. E., Wu, Y. C., Luan, L., Xie, C., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad200f · Cited by 9
Quinn, K. N., Tian, Y., Budde, R. B., Irazoqui, P. P., TUFFAHA, S. H., & Thakor, N. V. (2023) · Muscle & Nerve · doi:10.1002/mus.28029 · Cited by 9
Characterization of a conductive hydrogel@Carbon fibers electrode as a novel intraneural interface
Giannotti, A., Santanché, R., Zinno, C., Carpaneto, J., Micera, S., & Riva, E. R. (2024) · Bioelectronic Medicine · doi:10.1186/s42234-024-00154-5 · Cited by 10
“This limitation prevents achieving the spatial selectivity needed to discriminate between various nerve fibers, thereby hindering precise neuromodulation that elicits a specific physiological function and increasing the risk of secondary effects on other organs (Paggi et al. 2021).”
BackgroundSelf-citationDirected stimulation with interfascicular interfaces for peripheral nerve stimulation
Koppaka, S., Hess-Dunning, A., & Tyler, D. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac33e8 · Cited by 7
“Recently, interfascicular interfaces were called the ‘least common in literature’ [47].”
BackgroundBarberat, S., Nagarajan, S., Habib, M., Lebrun, A., Nieswic, N., Lauzon, M.-A., Aubert‐Pouëssel, A., Blanquer, S., & Labour, M.-N. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c00479 · Cited by 8
Akouissi, O., Lacour, S. P., Micera, S., & DeSimone, A. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7d0e · Cited by 7
Self-citationReddy, R. S., Alshahrani, M. S., ALMohiza, M. A., Alkhamis, B. A., Tedla, J. S., Kakaraparthi, V. N., Koura, G. M., Mukherjee, D., Alnakhli, H. H., Ghulam, H. S. H., et al. (2024) · PeerJ · doi:10.7717/peerj.17630 · Cited by 7
“In T2DM, alterations in blood glucose levels may impact nerve function and potentially disrupt proprioceptive feedback, which could, in turn, affect joint repositioning accuracy ( Paggi et al., 2021 ; Reddy et al., 2023 ).”
BackgroundLee, J. Y., Kim, T., Cho, S., Shin, J. H., Yeo, W., Kim, T. S., & Yu, K. J. (2025) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.02.006 · Cited by 11
“For this reason, a key design rule for LED devices targeting the SNS is ensuring stable and secure fixation at the implantation site [235,237].”
Zeng, M., Li, R., Pan, Y., Chen, Z., Zhang, Y., Ding, J., Wu, C., Sun, J., Yin, H., Wei, D., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202527261 · Cited by 5
Payne, S. C., Osborne, P. B., Thompson, A., Eiber, C. D., Keast, J. R., & Fallon, J. B. (2023) · APL Bioengineering · doi:10.1063/5.0164951 · Cited by 5
Accelerating neurotechnology development using an Agile methodology
Thota, A. K., & Jung, R. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1328540 · Cited by 7
“…Wu and Peng, 2019; Cho et al., 2020; Larson and Meng, 2020; Wu and Guo, 2020; Yildiz et al., 2020; del Valle et al., 2021; Eiber et al., 2021; Farina et al., 2021; Paggi et al., 2021; Selim et al., 2021) provide different perspectives but a convergent view on primary design requirements for PNI.”
BackgroundBianchini, M., Iacoponi, F., Battaglini, M., Ciofani, G., Micera, S., Ricotti, L., Riva, E. R., & Cafarelli, A. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c01086 · Cited by 8
Self-citationOn the Effect of Vibrotactile Stimulation in Essential Tremor
Cabral, A. M., Lora-Millán, J. S., Pereira, A. A., Rocón, E., & Andrade, A. D. O. (2024) · Healthcare · doi:10.3390/healthcare12040448 · Cited by 7
“These findings corroborate the analysis conducted for each participant (Figures 21 and 22).”
BackgroundResultLeung, E. S., & Mofatteh, M. (2025) · Cureus · doi:10.7759/cureus.82567 · Cited by 7
“Implantable PNIs allow more selectivity in recording and stimulation compared to non-invasive methods but face long-term challenges due to micromotion and signal degradation [24].”
Engineering Materials for Neurotechnology
Ghezzi, D. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202201412 · Cited by 2
Development of a 3D Printing Strategy for Completely Polymeric Neural Interfaces Fabrication
Zinno, C., Cedrola, I., Giannotti, A., Riva, E. R., & Micera, S. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123838 · Cited by 4
“Moreover, the material choice is highly limited by the need to use harsh reagents during manufacturing [1], [2].”
BackgroundSelf-citationOptogenetic modulation of peripheral nociceptive neurons with biocompatible optoelectronic implants
Chung, P. C. S., Paggi, V., Pertin, M., Kirschmann, G., Konnova, E. A., Michoud, F., Furfaro, I., Schneider, B. L., Lacour, S. P., & Décosterd, I. (2025) · Bioengineering & Translational Medicine · doi:10.1002/btm2.70034 · Cited by 2
Self-citationDeveloping Conductive Materials for Peripheral Nerve Interfaces
Zhang, H., Lü, L., Wang, Y., & Zhao, Y. (2025) · Small Methods · doi:10.1002/smtd.202501219 · Cited by 5
Conde, S. V., Sacramento, J. F., Zinno, C., Mazzoni, A., Micera, S., & Guarino, M. P. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1378473 · Cited by 3
“Moreover, the mechanical properties and the shape of the device also influence the degree of severity of the FBR. Typically, the use of soft inert materials is preferred for neural electrode, to reduce both the mechanical and chemical mismatch between the device and the nerves (Paggi et al., 2021).”
BackgroundSelf-citationMaterials and Devices for Stretchable Electronic Nerve Interfaces
Lienemann, S. (2022) · Linköping studies in science and technology. Dissertations · doi:10.3384/9789179293666 · Cited by 1
Woo, H. T., Yun, J., Lee, J., Song, K., & Chi, H. J. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123904 · Cited by 1
Mechanical behavior of nerve roots and pain mechanisms: insights and opportunities for advancement
Hoey, M., Estorge, R. B., Gallagher, K. M., Vadati, A., & Domire, Z. J. (2026) · Medical Engineering & Physics · doi:10.1088/1873-4030/ae28ed · Cited by 1
A High-Voltage, Implantable ASIC for Active Interfaces of the Vagus Nerve
Habibollahi, M., Li, J., Almarri, N., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10389014 · Cited by 1
“Bioelectronic solutions employ a wide range of neural electrodes to interface the nervous tissues, enabling direct communication with the fibres in the central or peripheral nervous system by providing the pathways for neural modulation, recording, and regeneration [2].”
BackgroundBorda, E., Gaillet, V., Leccardi, M. J. I. A., Zollinger, E. G., Moreira, R. C., & Ghezzi, D. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.03.21.485100
“Spatial selectivity in neuromodulation refers to interacting with neurons in a predefined and limited volume of tissue [35].”
BackgroundAdvancing Peripheral Nerve Interfaces in a Large Animal Model
Andreis, F. R. (2022) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau478976327
Zhong, Y., Luo, P., Wen, X., et al. (2024) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/j.aanat.2024.152231
Rosario, M., Zhang, J., Kaleem, M. I., Chandra, N. S., Yan, Y., Moran, D. W., Wood, M. D., Ray, W. Z., & MacEwan, M. R. (2024) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2024.110295
Peresada, D., Mzeihem, M., & Rybalko, D. A. (2025) · Springer eBooks · doi:10.1007/978-3-032-04688-8_26
Paggi, V., Fallegger, F., Serex, L., Rizzo, O., Galan, K., Giannotti, A., Furfaro, I., Zinno, C., Bernini, F., Micera, S., et al. (2024) · Figshare · doi:10.6084/m9.figshare.25216803
Self-citationGiannotti, A., Santanché, R., Zinno, C., Carpaneto, J., Micera, S., & Riva, E. R. (2024) · Figshare · doi:10.6084/m9.figshare.26839025
Self-citationA temporally biosynchronized and physically transient peripheral nerve interface
Yang, C., Hou, H., Sun, P., Dong, Y., Gao, X., Chen, L., Tan, J., Lu, Y., Yang, Z., Liu, S., et al. (2026) · Soft Science · doi:10.20517/ss.2026.11
Femtosecond-laser interfacial volume engineering for stable PEDOT: PSS/PtIr neural interfaces
You, X., Wang, X., Zhang, Y., Yang, Y., Bai, R., Huang, Y., Zhang, Z., Chen, H., Li, S., Yu, Q., et al. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.181967 · Cited by 1
Metadata
- Authors
- Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Scuola Superiore Sant'Anna (IT)
- Corresponding author
- Micera, Silvestro
- Lacour, Stéphanie P
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2021-03-08
- Volume
- 18
- Issue
- 3
- Pages
- 031001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3137684282
- Cited by
- 60
- References
- 253
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 16 · 2023: 11 · 2022: 14 · 2021: 5
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- Fondation Bertarelli
- Horizon 2020 Framework Programme (NeuTouch 813713)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (CHRONOS)
- H2020 Marie Skłodowska-Curie Actions (754354)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- peripheral nerve interfaces, implantable neural interfaces, flexible electronics, biocompatibility, foreign body reaction, neural recording, neurostimulation, optical stimulation, chemical stimulation, implant-tissue interface, neuroprosthetics, neuropathic pain
- MeSH terms
- Neurosciences, Peripheral Nerves, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.