A brain–computer interface using electrocorticographic signals in humans
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Brain-computer interfaces (BCIs) enable users to control devices with electroencephalographic (EEG) activity from the scalp or with single-neuron activity from within the brain. Both methods have disadvantages: EEG has limited resolution and requires extensive training, while single-neuron recording entails significant clinical risks and has limited stability. We demonstrate here for the first time that electrocorticographic (ECoG) activity recorded from the surface of the brain can enable users to control a one-dimensional computer cursor rapidly and accurately. We first identified ECoG signals that were associated with different types of motor and speech imagery. Over brief training periods of 3-24 min, four patients then used these signals to master closed-loop control and to achieve success rates of 74-100% in a one-dimensional binary task. In additional open-loop experiments, we found that ECoG signals at frequencies up to 180 Hz encoded substantial information about the direction of two-dimensional joystick movements. Our results suggest that an ECoG-based BCI could provide for people with severe motor disabilities a non-muscular communication and control option that is more powerful than EEG-based BCIs and is potentially more stable and less traumatic than BCIs that use electrodes penetrating the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“Brain–computer interfaces (BCIs) convert brain signals into outputs that communicate a user’s intent [1].”
BackgroundMethodSelf-citationFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Non-invasive BCIs use electroencephalographic activity (EEG) [2–7] recorded from the scalp.”
MethodNeuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationDigital Spectral Analysis with Applications.
Porat, B., & Marple, S. L. (1988) · Mathematics of Computation · doi:10.2307/2008605 · Cited by 2,644
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
Digital spectral analysis : with applications
Marple, S. L. (1987) · International Linear Collider · Cited by 1,732
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
(2021) · Applied Univariate, Bivariate, and Multivariate Statistics · doi:10.1002/9781119583004.ch2 · Cited by 1,327
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Self-citation
Research works printed but not linked: 4
- Pilcher W H, 1993, Neurosurg. Clin. N. Am., 4, 311, 10.1016/S1042-3680(18)30597-7 · DOI
- Wolpaw J R, 2003, Abstract Viewer/Itinerary Planner
- Schalk G, 2004, IEEE Trans. Biomed. Eng., at press
- Talairach J, 1988, Co-Planar Sterotaxic Atlas of the Human Brain
Cited by
Items 101–115 of 115
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
Christie, B. P., Tat, D. M., Irwin, Z. T., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., Thompson, D. E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016009 · Cited by 103
Ma, Z.-Z., Wu, J.-J., Cao, Z., Hua, X.-Y., Zheng, M.-X., Xing, X.-X., Ma, J., & Xu, J.-G. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01387-w · Cited by 97
“Many BCI systems are controlled through MI, but these systems may not have been developed specifically for dyskinesia, which is independent of normal motor control [46].”
BackgroundDeep brain stimulation: current and future perspectives
Awan, N. R., Lozano, A., & Hamani, C. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0982 · Cited by 83
Fifer, M. S., Acharya, S., Benz, H. L., Mollazadeh, M., Crone, N. E., & Thakor, N. V. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2175636 · Cited by 74
Collinger, J. L., Kryger, M. A., Barbara, R., Betler, T., Bowsher, K., Brown, E. H. P., Clanton, S. T., Degenhart, A. D., Foldes, S. T., Gaunt, R. A., et al. (2014) · Clinical and Translational Science · doi:10.1111/cts.12086 · Cited by 68
Moly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65
Hiremath, S. V., Chen, W., Wang, W., Foldes, S., Yang, Y., Tyler-Kabara, E. C., Collinger, J. L., & Boninger, M. L. (2015) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2015.00040 · Cited by 53
“BCI illiteracy has not been reported by BCI studies using implantable electrodes, but the number of subjects studied is typically small (Leuthardt et al., 2004; Hochberg et al., 2012; Collinger et al., 2013a; Wang et al., 2013).”
BackgroundRecording and decoding for neural prostheses
Warren, D. J., Kellis, S., Nieveen, J. G., Wendelken, S. M., Dantas, H., Davis, T. S., Hutchinson, D. T., Normann, R. A., Clark, G. A., & Mathews, V. J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2507180 · Cited by 52
“Early studies used motor and speech imagery to control up to 2 DoFs [122], [123].”
BackgroundSystems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45
“ECoG was first applied to BMI technology in the mid 2000s with human epilepsy patients undergoing temporary seizure monitoring [96], and achieved successful one-dimensional cursor control.”
MethodWireless opto-electro neural interface for experiments with small freely behaving animals
Jia, Y., Khan, W., Lee, B., Fan, B., Madi, F., Weber, A., Li, W., & Ghovanloo, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac810 · Cited by 47
“Each channel ECoG signal was averaged over four consecutive experiments and mapped onto a time-frequency map of the color-coded normalized power spectral density (PSD) distribution in 1–200 Hz frequency range [43].”
MethodEliseyev, A., Auboiroux, V., Costecalde, T., Langar, L., Charvet, G., Mestais, C., Aksenova, T., & Benabid, A.-L. (2017) · Scientific Reports · doi:10.1038/s41598-017-16579-9 · Cited by 42
Long-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients
Larzabal, C., Bonnet, S., Costecalde, T., Auboiroux, V., Charvet, G., Chabardes, S., Aksenova, T., & Sauter-Starace, F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2003 · Cited by 37
A Low-Power 0.7 $\mu {\rm V_{rms}}$ 32-Channel Mixed-Signal Circuit for ECoG Recordings
Robinet, S., Audebert, P., Regis, G., Zongo, B., Beche, J.-F., Condemine, C., Filipe, S., & Charvet, G. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2180835 · Cited by 30
“ECoG recordings, less invasive than deep brain measurements, show an interesting prospect as they naturally present higher signal-to-noise ratio (partly thanks to higher amplitudes 50–100 versus 10–20 ) and larger bandwidth than EEG recordings ([0–200 Hz] versus [0–40 Hz]) [15].”
BackgroundSpectral distribution of local field potential responses to electrical stimulation of the retina
Wong, Y. T., Halupka, K., Kameneva, T., Cloherty, S. L., Grayden, D. B., Burkitt, A. N., Meffin, H., & Shivdasani, M. N. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036003 · Cited by 16
Metadata
- Authors
- Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2004-06-01
- Volume
- 1
- Issue
- 2
- Pages
- 63-71
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2135825876
- Cited by
- 1,188
- References
- 50
- FWCI
- 18.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.