Automated MRI segmentation for individualized modeling of current flow in the human head
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: High-definition transcranial direct current stimulation (HD-tDCS) and high-density electroencephalography require accurate models of current flow for precise targeting and current source reconstruction. At a minimum, such modeling must capture the idiosyncratic anatomy of the brain, cerebrospinal fluid (CSF) and skull for each individual subject. Currently, the process to build such high-resolution individualized models from structural magnetic resonance images requires labor-intensive manual segmentation, even when utilizing available automated segmentation tools. Also, accurate placement of many high-density electrodes on an individual scalp is a tedious procedure. The goal was to develop fully automated techniques to reduce the manual effort in such a modeling process. APPROACH: A fully automated segmentation technique based on Statical Parametric Mapping 8, including an improved tissue probability map and an automated correction routine for segmentation errors, was developed, along with an automated electrode placement tool for high-density arrays. The performance of these automated routines was evaluated against results from manual segmentation on four healthy subjects and seven stroke patients. The criteria include segmentation accuracy, the difference of current flow distributions in resulting HD-tDCS models and the optimized current flow intensities on cortical targets. MAIN RESULTS: The segmentation tool can segment out not just the brain but also provide accurate results for CSF, skull and other soft tissues with a field of view extending to the neck. Compared to manual results, automated segmentation deviates by only 7% and 18% for normal and stroke subjects, respectively. The predicted electric fields in the brain deviate by 12% and 29% respectively, which is well within the variability observed for various modeling choices. Finally, optimized current flow intensities on cortical targets do not differ significantly. SIGNIFICANCE: Fully automated individualized modeling may now be feasible for large-sample EEG research studies and tDCS clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“Electrode montages are depicted schematically (Delorme and Makeig 2004) for the two approaches with anodes and cathodes in red and blue, respectively.”
BackgroundAdvances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 1×
“There are many open-source packages and commercial software tools for automatic MRI segmentation other than SPM8, e.g., FMRIB Software Library (FSL, Smith et al 2004), FieldTrip (Oostenveld et al 2011), FreeSurfer (Dale et al 1999, Fischl et al 1999), ITK-SNAP (Yushkevich et al 2006), NFT (Acar and…”
MethodCortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910 · cited 3×
“FreeSurfer appears slow in segmentation (22 h for one head, see Windhoff et al (2011)).”
MethodFast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496 · cited 1×
“FSL Brain Extraction Tool (BET, Smith 2002) and FieldTrip can extract the skull and scalp surfaces, but it only operates on the standard FOV (the brain area only).”
MethodOostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323 · cited 5×
“Additionally, manually placing tens to hundreds of electrodes onto these models can be a tedious process, though some techniques have already been proposed (Oostenveld et al 2011, see section 2.4).”
MethodInfluentialYushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868 · cited 3×
“…e.g., FMRIB Software Library (FSL, Smith et al 2004), FieldTrip (Oostenveld et al 2011), FreeSurfer (Dale et al 1999, Fischl et al 1999), ITK-SNAP (Yushkevich et al 2006), NFT (Acar and Makeig 2010), ASA (ANT Software BV, Enschede, Netherlands), Curry (Compumedics NeuroScan, Charlotte, NC), BESA…”
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Cortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147 · cited 1×
“…segmentation other than SPM8, e.g., FMRIB Software Library (FSL, Smith et al 2004), FieldTrip (Oostenveld et al 2011), FreeSurfer (Dale et al 1999, Fischl et al 1999), ITK-SNAP (Yushkevich et al 2006), NFT (Acar and Makeig 2010), ASA (ANT Software BV, Enschede, Netherlands), Curry (Compumedics…”
Method(1982) · Elsevier eBooks · doi:10.1016/c2009-0-21955-6 · Cited by 4,596
Klem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361
Cited by
Thielscher, A., Antunes, A., & Saturnino, G. B. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318340 · Cited by 942
“It might also be worth to improve the automatic segmentation of the skull by distinguishing between compartments of spongy and compact bone [22] in order to further improve the accuracy of the head model in case of tDCS.”
BackgroundHuang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Self-citationApplications of transcranial direct current stimulation for understanding brain function
Filmer, H. L., Dux, P. E., & Mattingley, J. B. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2014.08.003 · Cited by 519
Huang, Y., Datta, A., Bikson, M., & Parra, L. C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab208d · Cited by 362
Self-citationNielsen, J. D., Madsen, K. H., Puonti, O., Siebner, H. R., Bauer, C., Madsen, C. G., Saturnino, G. B., & Thielscher, A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.001 · Cited by 271
Huang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
Self-citationPuonti, O., Van Leemput, K., Saturnino, G. B., Siebner, H. R., Madsen, K. H., & Thielscher, A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117044 · Cited by 235
“The segmentations used to build the extended tissue probability maps used in HEADRECO and ROAST use different tissue class assignments (Huang et al., 2013), which likely results in underestimation of the segmentation accuracy for the WM and GM tissues.”
MethodInfluentialBikson, M., Brunoni, A. R., Charvet, L. E., Clark, V. P., Cohen, L. G., Deng, Z.-D., Dmochowski, J., Edwards, D. J., Frohlich, F., Kappenman, E. S., et al. (2018) · Brain Stimulation · doi:10.1016/j.brs.2017.12.008 · Cited by 213
“will reduce the computational burden [78] and automate image processing for individual electric field modeling [92,93].”
BackgroundSelf-citationLafon, B., Henin, S., Huang, Y., Friedman, D., Melloni, L., Thesen, T., Doyle, W., Buzsáki, G., Devinsky, O., Parra, L. C., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01045-x · Cited by 198
Self-citationAlam, M., Truong, D. Q., Khadka, N., & Bikson, M. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/4506 · Cited by 197
“A MATLAB script was then used to smooth artifacts and correct for discontinuities (Huang et al 2013).”
MethodDose-controlled tDCS reduces electric field intensity variability at a cortical target site
Evans, C., Bachmann, C., Lee, J. S. A., Gregoriou, E., Ward, N., & Bestmann, S. (2020) · Brain Stimulation · doi:10.1016/j.brs.2019.10.004 · Cited by 164
Salehinejad, M. A., Nejati, V., Mosayebi-Samani, M., Mohammadi, A., Wischnewski, M., Kuo, M.-F., Avenanti, A., Vicario, C. M., & Nitsche, M. A. (2020) · Neuroscience Bulletin · doi:10.1007/s12264-020-00501-x · Cited by 118
Modeling transcranial electrical stimulation in the aging brain
Indahlastari, A., Albizu, A., O’Shea, A., Forbes, M. A., Nissim, N. R., Kraft, J. N., Evangelista, N. D., Hausman, H. K., & Woods, A. J. (2020) · Brain Stimulation · doi:10.1016/j.brs.2020.02.007 · Cited by 113
“In ROAST, each head volume was segmented into white matter (WM), g ray matter (GM), CSF, bone, skin, and air compartments [27,28].”
MethodAlbizu, A., Fang, R., Indahlastari, A., O’Shea, A., Stolte, S. E., See, K. B., Boutzoukas, E. M., Kraft, J. N., Nissim, N. R., & Woods, A. J. (2020) · Brain Stimulation · doi:10.1016/j.brs.2020.10.001 · Cited by 79
“Segmentations from FreeSurfer were then combined with segmented CSF, bone, skin, and air from ROAST (See Supplemental Fig.”
MethodInfluentialSenço, N. M., Huang, Y., D’Urso, G., Parra, L. C., Bikson, M., Mantovani, A., Shavitt, R. G., Hoexter, M. Q., Miguel, E. C., & Brunoni, A. R. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1037832 · Cited by 67
Self-citationBiophysically detailed forward modeling of the neural origin of EEG and MEG signals
Næss, S., Halnes, G., Hagen, E., Hagler, D. J., Dale, A. M., Einevoll, G. T., & Ness, T. V. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117467 · Cited by 66
“However, from mochowski et al. (2017) and Huang et al. (2013) it appears that an njected current I of 1 mA gives an electric potential E in V/m, meaning hat a current dipole moment p in the unit of mAm gives EEG signals in he unit of V. .3.”
BackgroundMethodIndahlastari, A., Hardcastle, C., Albizu, A., Alvarez-Alvarado, S., Boutzoukas, E. M., Evangelista, N. D., Hausman, H. K., Kraft, J., Langer, K., & Woods, A. J. (2021) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s259499 · Cited by 64
Rasmussen, I. D., Boayue, N. M., Mittner, M., Bystad, M., Grønli, O. K., Vangberg, T. R., Csifcsák, G., & Aslaksen, P. M. (2021) · Journal of Alzheimer's Disease · doi:10.3233/jad-210378 · Cited by 42
Metadata
- Authors
- Huang, Y., Dmochowski, J. P., Su, Y., Datta, A., Rorden, C., & Parra, L. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-10-08
- Volume
- 10
- Issue
- 6
- Pages
- 066004
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2123171443
- Cited by
- 162
- References
- 44
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.