Automated MRI segmentation for individualized modeling of current flow in the human head
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: High-definition transcranial direct current stimulation (HD-tDCS) and high-density electroencephalography require accurate models of current flow for precise targeting and current source reconstruction. At a minimum, such modeling must capture the idiosyncratic anatomy of the brain, cerebrospinal fluid (CSF) and skull for each individual subject. Currently, the process to build such high-resolution individualized models from structural magnetic resonance images requires labor-intensive manual segmentation, even when utilizing available automated segmentation tools. Also, accurate placement of many high-density electrodes on an individual scalp is a tedious procedure. The goal was to develop fully automated techniques to reduce the manual effort in such a modeling process. APPROACH: A fully automated segmentation technique based on Statical Parametric Mapping 8, including an improved tissue probability map and an automated correction routine for segmentation errors, was developed, along with an automated electrode placement tool for high-density arrays. The performance of these automated routines was evaluated against results from manual segmentation on four healthy subjects and seven stroke patients. The criteria include segmentation accuracy, the difference of current flow distributions in resulting HD-tDCS models and the optimized current flow intensities on cortical targets. MAIN RESULTS: The segmentation tool can segment out not just the brain but also provide accurate results for CSF, skull and other soft tissues with a field of view extending to the neck. Compared to manual results, automated segmentation deviates by only 7% and 18% for normal and stroke subjects, respectively. The predicted electric fields in the brain deviate by 12% and 29% respectively, which is well within the variability observed for various modeling choices. Finally, optimized current flow intensities on cortical targets do not differ significantly. SIGNIFICANCE: Fully automated individualized modeling may now be feasible for large-sample EEG research studies and tDCS clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“Electrode montages are depicted schematically (Delorme and Makeig 2004) for the two approaches with anodes and cathodes in red and blue, respectively.”
BackgroundAdvances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 1×
“There are many open-source packages and commercial software tools for automatic MRI segmentation other than SPM8, e.g., FMRIB Software Library (FSL, Smith et al 2004), FieldTrip (Oostenveld et al 2011), FreeSurfer (Dale et al 1999, Fischl et al 1999), ITK-SNAP (Yushkevich et al 2006), NFT (Acar and…”
MethodCortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910 · cited 3×
“FreeSurfer appears slow in segmentation (22 h for one head, see Windhoff et al (2011)).”
MethodFast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496 · cited 1×
“FSL Brain Extraction Tool (BET, Smith 2002) and FieldTrip can extract the skull and scalp surfaces, but it only operates on the standard FOV (the brain area only).”
MethodOostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323 · cited 5×
“Additionally, manually placing tens to hundreds of electrodes onto these models can be a tedious process, though some techniques have already been proposed (Oostenveld et al 2011, see section 2.4).”
MethodInfluentialYushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868 · cited 3×
“…e.g., FMRIB Software Library (FSL, Smith et al 2004), FieldTrip (Oostenveld et al 2011), FreeSurfer (Dale et al 1999, Fischl et al 1999), ITK-SNAP (Yushkevich et al 2006), NFT (Acar and Makeig 2010), ASA (ANT Software BV, Enschede, Netherlands), Curry (Compumedics NeuroScan, Charlotte, NC), BESA…”
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Cortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147 · cited 1×
“…segmentation other than SPM8, e.g., FMRIB Software Library (FSL, Smith et al 2004), FieldTrip (Oostenveld et al 2011), FreeSurfer (Dale et al 1999, Fischl et al 1999), ITK-SNAP (Yushkevich et al 2006), NFT (Acar and Makeig 2010), ASA (ANT Software BV, Enschede, Netherlands), Curry (Compumedics…”
Method(1982) · Elsevier eBooks · doi:10.1016/c2009-0-21955-6 · Cited by 4,596
Klem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361
Datta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290 · cited 6×
“To simulate the current flow distribution inside the head, the Laplace equation (−∇ · (σ∇V ) = 0, V : electric potential distribution in the volume; σ : tissue conductivity) needs to be solved (Griffiths 1999, Datta et al 2009).”
BackgroundMethodInfluentialSelf-citationIntroduction to electrodynamics
CAPRI, A. Z. (2000) · Cited by 1,211
Tetrahedral mesh generation from volumetric binary and grayscale images
Fang, Q., & Boas, D. A. (2009) · 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2009.5193259 · Cited by 691 · cited 1×
“This may be useful in particular if one wishes to circumvent proprietary softwares (ScanIP and Abaqus) and use free tools such as iso2mesh (Fang and Boas 2009) and GetFEM++ (Renard and Pommier 2010) for meshing and FEM solving.”
MethodOptimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 590 · cited 3×
“Electrode locations for transcranial stimulation are selected such that ‘hot-spots’ of stimulation coincide with the targeted brain area (Datta et al 2009, Dmochowski et al 2011).”
BackgroundMethodSelf-citationAn Open Source Multivariate Framework for n-Tissue Segmentation with Evaluation on Public Data
Avants, B. B., Tustison, N. J., Wu, J., Cook, P. A., & Gee, J. C. (2011) · Neuroinformatics · doi:10.1007/s12021-011-9109-y · Cited by 576 · cited 2×
“There are many open-source packages and commercial software tools for automatic MRI segmentation other than SPM8, e.g., FMRIB Software Library (FSL, Smith et al 2004), FieldTrip (Oostenveld et al 2011), FreeSurfer (Dale et al 1999, Fischl et al 1999), ITK-SNAP (Yushkevich et al 2006), NFT (Acar and Makeig 2010), ASA (…”
BackgroundTranscranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567 · cited 2×
“To the best of our knowledge, there are only a few modeling studies for stroke patients, e.g. Wagner et al (2007) and Datta et al (2011), and they use conventional manual segmentation.”
MethodInfluentialUsing transcranial direct-current stimulation to treat stroke patients with aphasia
Baker, J. M., Rorden, C., & Fridriksson, J. (2010) · Stroke · doi:10.1161/strokeaha.109.576785 · Cited by 516 · cited 1×
“The targets are at eloquent peri-lesional cortical areas (figure 11), and were determined from functional MRI (Baker et al 2010).”
BackgroundSelf-citationWindhoff, M., Opitz, A., & Thielscher, A. (2013) · Human Brain Mapping · doi:10.1002/hbm.21479 · Cited by 441
Datta, A., Truong, D., Minhas, P., Parra, L. C., & Bikson, M. (2012) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2012.00091 · Cited by 404 · cited 2×
“…of accuracy yielded by modern modeling techniques, generic 1741-2560/13/066004+13$33.00 1 © 2013 IOP Publishing Ltd Printed in the UK & the USA head models are no longer useful: cortical folding is highly idiosyncratic and drastically affects the resulting current flow (Datta et al 2009, 2012).”
MethodInfluentialSelf-citationDatta, A., Baker, J. M., Bikson, M., & Fridriksson, J. (2011) · Brain Stimulation · doi:10.1016/j.brs.2010.11.001 · Cited by 325 · cited 1×
“To the best of our knowledge, there are only a few modeling studies for stroke patients, e.g. Wagner et al (2007) and Datta et al (2011), and they use conventional manual segmentation.”
MethodSelf-citationLesion identification using unified segmentation-normalisation models and fuzzy clustering
Seghier, M. L., Ramlackhansingh, A., Crinion, J., Leff, A. P., & Price, C. J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.028 · Cited by 317 · cited 1×
“A few automated segmentation algorithms do exist that are specifically intended for lesioned brain anatomies, e.g. Seghier et al (2008).”
BackgroundModeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268 · cited 1×
“This differentiation is important because these two types of bone have different electrical conductivities (Dannhauer et al 2011).”
BackgroundEffects of Forward Model Errors on EEG Source Localization
Akalin Acar, Z., & Makeig, S. (2013) · Brain Topography · doi:10.1007/s10548-012-0274-6 · Cited by 265 · cited 1×
“The same applies to current source reconstruction in high-density electroencephalography (HD-EEG) (Vatta et al 2010, Gllmar et al 2010, Akalin Acar and Makeig 2013).”
BackgroundNeuling, T., Wagner, S., Wolters, C. H., Zaehle, T., & Herrmann, C. S. (2012) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2012.00083 · Cited by 227 · cited 1×
“There are a number of approaches to convert diffusion tensor imaging (DTI) data to conductivity tensor data thereby incorporating anisotropy in the modeling for tDCS (Windhoff et al 2011, Neuling et al 2012, Suh et al 2012, Shahid et al 2013).”
MethodGüllmar, D., Haueisen, J., & Reichenbach, J. R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.014 · Cited by 214
Datta, A., Bikson, M., & Fregni, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.252 · Cited by 211 · cited 2×
“We opted to reassign GM (as opposed to the skull), as intuition suggests that this will perturb current flow less severely, because the skull is a thinner layer compared to GM, lending itself less well to displacement (Datta et al 2010).”
BackgroundMethodSelf-citationSubject position affects EEG magnitudes
Rice, J. K., Rorden, C., Little, J. S., & Parra, L. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.041 · Cited by 181 · cited 7×
“Finally, while the highly resistive skull is the main attenuating barrier for tDCS and EEG currents, and its thickness is quite variable within and across subjects, the current flow modeling can be greatly affected if the model does not accurately capture the exact skull geometry (Datta et al 2010, Lanfer et al 2012).”
BackgroundInfluentialSelf-citationMendonca, M. E., Santana, M. B., Baptista, A. F., Datta, A., Bikson, M., Fregni, F., & Araujo, C. P. (2011) · The Journal of Pain · doi:10.1016/j.jpain.2010.12.015 · Cited by 163 · cited 1×
“High-definition transcranial direct current stimulation (HD-tDCS) requires accurate models of current flow for precise targeting (Datta et al 2009, 2012, Mendonca et al 2011, Caparelli-Daquer et al 2012, Minhas et al 2012).”
MethodSelf-citationTargeted transcranial direct current stimulation for rehabilitation after stroke
Dmochowski, J., Datta, A., Huang, Y., Richardson, J. D., Bikson, M., Fridriksson, J., & Parra, L. C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.02.049 · Cited by 162 · cited 5×
“In our experiments, we have provided the 3D rendering (figure 6(a)) and electrode locations of the model to the experimenters so as to facilitate proper cap adjustment (Dmochowski et al 2013).”
BackgroundMethodInfluentialSelf-citationSegmentation of MR images with intensity inhomogeneities
Rajapakse, J. C., & Kruggel, F. (1998) · Image and Vision Computing · doi:10.1016/s0262-8856(97)00067-x · Cited by 159 · cited 1×
“In one study (Rajapakse and Kruggel 1998), expert operators segmenting the same brains obtained Jaccard indices of 0.876 and 0.832 for GM and WM, respectively.”
InfluentialDatta, A., Zhou, X., Su, Y., Parra, L. C., & Bikson, M. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036018 · Cited by 145 · cited 1×
“Initial efforts to validate the models have been limited to voltage recordings on the surface of the scalp (Datta et al 2013) and indirect measurements using functional MRI (Antal et al 2012).”
BackgroundSelf-citationImaging artifacts induced by electrical stimulation during conventional fMRI of the brain
Antal, A., Bikson, M., Datta, A., Lafon, B., Dechent, P., Parra, L. C., & Paulus, W. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.026 · Cited by 136
Self-citationNeuroelectromagnetic Forward Head Modeling Toolbox
Acar, Z. A., & Makeig, S. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.031 · Cited by 134 · cited 3×
“There are many open-source packages and commercial software tools for automatic MRI segmentation other than SPM8, e.g., FMRIB Software Library (FSL, Smith et al 2004), FieldTrip (Oostenveld et al 2011), FreeSurfer (Dale et al 1999, Fischl et al 1999), ITK-SNAP (Yushkevich et al 2006), NFT (Acar and Makeig 2010), ASA (…”
BackgroundTranscranial direct current stimulation in pediatric brain: A computational modeling study
Minhas, P., Bikson, M., Woods, A. J., Rosen, A. R., & Kessler, S. K. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346067 · Cited by 126
Influences of skull segmentation inaccuracies on EEG source analysis
Lanfer, B., Scherg, M., Dannhauer, M., Knösche, T. R., Burger, M., & Wolters, C. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.006 · Cited by 113 · cited 1×
“…resistive skull is the main attenuating barrier for tDCS and EEG currents, and its thickness is quite variable within and across subjects, the current flow modeling can be greatly affected if the model does not accurately capture the exact skull geometry (Datta et al 2010, Lanfer et al 2012).”
BackgroundA pilot study on effects of 4×1 High-Definition tDCS on motor cortex excitability
Caparelli-Dáquer, E. M., Zimmermann, T. J., Mooshagian, E., Parra, L. C., Rice, J. K., Datta, A., Bikson, M., & Wassermann, E. M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346036 · Cited by 100
Self-citationSuh, H. S., Lee, W. H., & Kim, T.-S. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/6961 · Cited by 84 · cited 2×
“…electric and DTI anisotropy has not yet been established experimentally, and thus there is a certain level of arbitrariness to the different choices made by these techniques (from 3% to 58% difference in current flow distribution compared to isotropic modeling (Suh et al 2012, Shahid et al 2013)).”
BackgroundMethodVatta, F., Meneghini, F., Esposito, F., Mininel, S., & Salle, F. D. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/972060 · Cited by 84 · cited 3×
“Accurate current flow models for HD-tDCS and forward modeling for HD-EEG require detailed anatomical models of the human head as well as placement of a large number of electrodes.”
BackgroundShahid, S. S., Wen, P. P., & Ahfock, T. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.09.001 · Cited by 71 · cited 2×
“…electric and DTI anisotropy has not yet been established experimentally, and thus there is a certain level of arbitrariness to the different choices made by these techniques (from 3% to 58% difference in current flow distribution compared to isotropic modeling (Suh et al 2012, Shahid et al 2013)).”
BackgroundMethodDannhauer, M., Brooks, D. H., Tucker, D. M., & MacLeod, R. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347236 · Cited by 56
On the convergence of EM-like algorithms for image segmentation using Markov random fields
Roche, A., Ribes, D., Cuadra, M. B., & Krüger, G. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.05.002 · Cited by 51 · cited 1×
“Future work will aim to integrate smoothing and segmentation into a single step by merging Markov random field models (Roche et al 2011) with the New Segment formalism (Ashburner and Friston 2005).”
MethodAutomatic localization and labeling of EEG sensors (ALLES) in MRI volume
Koessler, L., Benhadid, A., Maillard, L. G., Vignal, J., Felblinger, J., Vespignani, H., & Braun, M. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.02.039 · Cited by 44 · cited 1×
“Therefore, we developed an automated algorithm for electrode placement which can place and model multiple electrodes following a standard montage in several minutes (some ideas adapted from Koessler et al (2008)).”
MethodDmochowski, J., Bikson, M., & Parra, L. C. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/20/6459 · Cited by 42 · cited 8×
“Accurate current flow models for HD-tDCS and forward modeling for HD-EEG require detailed anatomical models of the human head as well as placement of a large number of electrodes.”
BackgroundInfluentialSelf-citationSingle-Layer Skull Approximations Perform Well in Transcranial Direct Current Stimulation Modeling
Rampersad, S. M., Stegeman, D. F., & Oostendorp, T. F. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2206829 · Cited by 27
Cited by
Thielscher, A., Antunes, A., & Saturnino, G. B. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318340 · Cited by 942
“It might also be worth to improve the automatic segmentation of the skull by distinguishing between compartments of spongy and compact bone [22] in order to further improve the accuracy of the head model in case of tDCS.”
BackgroundHuang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Self-citationApplications of transcranial direct current stimulation for understanding brain function
Filmer, H. L., Dux, P. E., & Mattingley, J. B. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2014.08.003 · Cited by 519
Huang, Y., Datta, A., Bikson, M., & Parra, L. C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab208d · Cited by 362
Self-citationNielsen, J. D., Madsen, K. H., Puonti, O., Siebner, H. R., Bauer, C., Madsen, C. G., Saturnino, G. B., & Thielscher, A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.001 · Cited by 271
Metadata
- Authors
- Huang, Y., Dmochowski, J. P., Su, Y., Datta, A., Rorden, C., & Parra, L. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-10-08
- Volume
- 10
- Issue
- 6
- Pages
- 066004
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2123171443
- Cited by
- 162
- References
- 44
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.