Robust artifactual independent component classification for BCI practitioners
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: EEG artifacts of non-neural origin can be separated from neural signals by independent component analysis (ICA). It is unclear (1) how robustly recently proposed artifact classifiers transfer to novel users, novel paradigms or changed electrode setups, and (2) how artifact cleaning by a machine learning classifier impacts the performance of brain-computer interfaces (BCIs). APPROACH: Addressing (1), the robustness of different strategies with respect to the transfer between paradigms and electrode setups of a recently proposed classifier is investigated on offline data from 35 users and 3 EEG paradigms, which contain 6303 expert-labeled components from two ICA and preprocessing variants. Addressing (2), the effect of artifact removal on single-trial BCI classification is estimated on BCI trials from 101 users and 3 paradigms. MAIN RESULTS: We show that (1) the proposed artifact classifier generalizes to completely different EEG paradigms. To obtain similar results under massively reduced electrode setups, a proposed novel strategy improves artifact classification. Addressing (2), ICA artifact cleaning has little influence on average BCI performance when analyzed by state-of-the-art BCI methods. When slow motor-related features are exploited, performance varies strongly between individuals, as artifacts may obstruct relevant neural activity or are inadvertently used for BCI control. SIGNIFICANCE: Robustness of the proposed strategies can be reproduced by EEG practitioners as the method is made available as an EEGLAB plug-in.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 4×
“We provide the ready-to-use artifact classifier to the community as an open-source EEGLAB plug-in called MARA (multiple artifact rejection algorithm).”
MethodInfluentialAdvances in neural information processing systems 7
(1996) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(96)90463-0 · Cited by 14,281
A Fast Fixed-Point Algorithm for Independent Component Analysis
Hyvärinen, A., & Oja, E. (1997) · Neural Computation · doi:10.1162/neco.1997.9.7.1483 · Cited by 3,391
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Unbiased average age-appropriate atlases for pediatric studies
Fonov, V., Evans, A. C., Botteron, K., Almli, C. R., McKinstry, R. C., & Collins, D. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.033 · Cited by 2,290 · cited 1×
“We considered 2142 locations arranged in a 1 cm spaced 3D-grid, formulated the forward problem according to [41–43] and sought the source distribution with minimal l2-norm (i.”
MethodUnbiased nonlinear average age-appropriate brain templates from birth to adulthood
Fonov, V., Evans, A., McKinstry, R., Almli, C., & Collins, D. (2009) · NeuroImage · doi:10.1016/s1053-8119(09)70884-5 · Cited by 2,102
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 1×
“After enhancing the SNR of these effects by individual data-driven spatial filters, which are derived by the common spatial patterns (CSP) analysis [51], CSPfeatures can be classified by a shrinkage-regularized linear classifier.”
MethodInterpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
Cited by
ICLabel: An automated electroencephalographic independent component classifier, dataset, and website
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.026 · Cited by 2,267
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
Gabard-Durnam, L. J., Mendez Leal, A. S., Wilkinson, C. L., & Levin, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00097 · Cited by 535
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP
Winkler, I., Debener, S., Muller, K.-R., & Tangermann, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319296 · Cited by 407
Self-citationSmith, E. E., Reznik, S. J., Stewart, J. L., & Allen, J. J. B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.11.005 · Cited by 335
Automagic: Standardized preprocessing of big EEG data
Pedroni, A., Bahreini, A., & Langer, N. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.046 · Cited by 292
Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
“ICA is the most commonly employed BSS technique in EEG artifact removal studies [22], [23], [25], [81]–[83].”
MethodEEG power spectral slope differs by ADHD status and stimulant medication exposure in early childhood
Robertson, M. M., Furlong, S., Voytek, B., Donoghue, T., Boettiger, C. A., & Sheridan, M. A. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00388.2019 · Cited by 203
“The ICA decomposition was then calculated in EEGLAB, and we used the MARA EEGLAB plug-in (Winkler et al. 2011, 2014).”
MethodZuCo, a simultaneous EEG and eye-tracking resource for natural sentence reading
Hollenstein, N., Rotsztejn, J., Troendle, M., Pedroni, A., Zhang, C., & Langer, N. (2018) · Scientific Data · doi:10.1038/sdata.2018.291 · Cited by 199
Škola, F., Rizvić, S., Cozza, M., Barbieri, L., Bruno, F., Skarlatos, D., & Liarokapis, F. (2020) · Sensors · doi:10.3390/s20205851 · Cited by 180
“Removal of the artifactual components was automatized using a multiple-artifact rejection algorithm [55] (available as a plugin for EEGLAB).”
MethodLongitudinal EEG power in the first postnatal year differentiates autism outcomes
Gabard-Durnam, L. J., Wilkinson, C., Kapur, K., Tager-Flusberg, H., Levin, A. R., & Nelson, C. A. (2019) · Nature Communications · doi:10.1038/s41467-019-12202-9 · Cited by 179
Wang, M., El-Fiqi, H., Hu, J., & Abbass, H. A. (2019) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2019.2916403 · Cited by 172
“For signal pre-processing, an FIR filter with Hamming window was implemented to restrict the available frequency range to [0.5 42]Hz after removing the DC offset (the linear trend), then artifacts were removed using independent component analysis (ICA) [46].”
MethodInfluentialYeom, S., Kim, H., & Hong, T. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108134 · Cited by 172
Augmenting the size of EEG datasets using generative adversarial networks
Abdelfattah, S. M., Abdelrahman, G. M., & Wang, M. (2018) · 2018 International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2018.8489727 · Cited by 122
Škola, F., Tinková, S., & Liarokapis, F. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00329 · Cited by 102
“ICA decomposition was calculated for each dataset separately, and artifactual components were identified using the Multiple Artifact Rejection Algorithm (Winkler et al., 2014).”
MethodSignal Artifacts and Techniques for Artifacts and Noise Removal
Islam, M. K., Rastegarnia, A., & Sanei, S. (2021) · Intelligent Systems Reference Library · doi:10.1007/978-3-030-54932-9_2 · Cited by 54
Arciniega, H., Shires, J., Furlong, S., Kilgore-Gomez, A., Cerreta, A., Murray, N. G., & Berryhill, M. E. (2021) · Scientific Reports · doi:10.1038/s41598-021-80995-1 · Cited by 33
Metadata
- Authors
- Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-05-19
- Volume
- 11
- Issue
- 3
- Pages
- 035013
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1994321338
- Cited by
- 327
- References
- 48
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.