Robust artifactual independent component classification for BCI practitioners
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: EEG artifacts of non-neural origin can be separated from neural signals by independent component analysis (ICA). It is unclear (1) how robustly recently proposed artifact classifiers transfer to novel users, novel paradigms or changed electrode setups, and (2) how artifact cleaning by a machine learning classifier impacts the performance of brain-computer interfaces (BCIs). APPROACH: Addressing (1), the robustness of different strategies with respect to the transfer between paradigms and electrode setups of a recently proposed classifier is investigated on offline data from 35 users and 3 EEG paradigms, which contain 6303 expert-labeled components from two ICA and preprocessing variants. Addressing (2), the effect of artifact removal on single-trial BCI classification is estimated on BCI trials from 101 users and 3 paradigms. MAIN RESULTS: We show that (1) the proposed artifact classifier generalizes to completely different EEG paradigms. To obtain similar results under massively reduced electrode setups, a proposed novel strategy improves artifact classification. Addressing (2), ICA artifact cleaning has little influence on average BCI performance when analyzed by state-of-the-art BCI methods. When slow motor-related features are exploited, performance varies strongly between individuals, as artifacts may obstruct relevant neural activity or are inadvertently used for BCI control. SIGNIFICANCE: Robustness of the proposed strategies can be reproduced by EEG practitioners as the method is made available as an EEGLAB plug-in.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 4×
“We provide the ready-to-use artifact classifier to the community as an open-source EEGLAB plug-in called MARA (multiple artifact rejection algorithm).”
MethodInfluentialAdvances in neural information processing systems 7
(1996) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(96)90463-0 · Cited by 14,281
A Fast Fixed-Point Algorithm for Independent Component Analysis
Hyvärinen, A., & Oja, E. (1997) · Neural Computation · doi:10.1162/neco.1997.9.7.1483 · Cited by 3,391
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Unbiased average age-appropriate atlases for pediatric studies
Fonov, V., Evans, A. C., Botteron, K., Almli, C. R., McKinstry, R. C., & Collins, D. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.033 · Cited by 2,290 · cited 1×
“We considered 2142 locations arranged in a 1 cm spaced 3D-grid, formulated the forward problem according to [41–43] and sought the source distribution with minimal l2-norm (i.”
MethodUnbiased nonlinear average age-appropriate brain templates from birth to adulthood
Fonov, V., Evans, A., McKinstry, R., Almli, C., & Collins, D. (2009) · NeuroImage · doi:10.1016/s1053-8119(09)70884-5 · Cited by 2,102
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 1×
“After enhancing the SNR of these effects by individual data-driven spatial filters, which are derived by the common spatial patterns (CSP) analysis [51], CSPfeatures can be classified by a shrinkage-regularized linear classifier.”
MethodInterpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Self-citationSingle-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Winkler, I., Haufe, S., & Tangermann, M. (2011) · Behavioral and Brain Functions · doi:10.1186/1744-9081-7-30 · Cited by 778
Self-citationNeurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674 · cited 1×
“During the three online runs of 100 trials each participant controlled an application which provided continuous visual feedback in the form of a horizontally moving cursor [50].”
MethodBrain basis of human social interaction: from concepts to brain imaging
Hari, R., & Kujala, M. V. (2009) · Physiological Reviews · doi:10.1152/physrev.00041.2007 · Cited by 638
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Pfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
How about taking a low‐cost, small, and wireless EEG for a walk?
Debener, S., Minow, F., Emkes, R., Gandras, K., & de Vos, M. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01471.x · Cited by 540
Patients with ALS can use sensorimotor rhythms to operate a brain-computer interface
Kübler, A., Nijboer, F., Mellinger, J., Vaughan, T. M., Pawelzik, H., Schalk, G., McFarland, D. J., Birbaumer, N., & Wolpaw, J. R. (2005) · Neurology · doi:10.1212/01.wnl.0000158616.43002.6d · Cited by 539
Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00105.2010 · Cited by 481
Blind Source Separation and Independent Component Analysis: A Review
Lee, S.-Y. (2005) · International Conference on Neural Information Processing · Cited by 374
Semi-automatic identification of independent components representing EEG artifact
Campos Viola, F., Thorne, J., Edmonds, B., Schneider, T., Eichele, T., & Debener, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.015 · Cited by 364
Brain-Computer Interfaces: Beyond Medical Applications
van Erp, J., Lotte, F., & Tangermann, M. (2012) · Computer · doi:10.1109/mc.2012.107 · Cited by 362
Self-citationThe Berlin Brain–Computer Interface: Non-Medical Uses of BCI Technology
Blankertz, B., Tangermann, M., Vidaurre, C., Fazli, S., Sannelli, C., Haufe, S., Maeder, C., Ramsey, L., Sturm, I., Curio, G., et al. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00198 · Cited by 357 · cited 1×
“Such studies include users (inter-)acting in space [7–9] like in collaborative and social paradigms (for a review see [10]), the interaction between users and machines [11] and the nonmedical use of BCI methods [12, 13].”
BackgroundSelf-citationCognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K., Jung, T.-P., Lin, C.-T., Liao, L.-D., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 302
Automatic Removal of Ocular Artifacts in the EEG without an EOG Reference Channel
Gomez-Herrero, G., De Clercq, W., Anwar, H., Kara, O., Egiazarian, K., Van Huffel, S., & Van Paesschen, W. (2006) · Proceedings of the 7th Nordic Signal Processing Symposium - NORSIG 2006 · doi:10.1109/norsig.2006.275210 · Cited by 241
Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG
McMenamin, B. W., Shackman, A. J., Maxwell, J. S., Bachhuber, D. R. W., Koppenhaver, A. M., Greischar, L. L., & Davidson, R. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.010 · Cited by 211
Romero, S., Mañanas, M. A., & Barbanoj, M. J. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.12.001 · Cited by 191
LeVan, P., Urrestarazu, E., & Gotman, J. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.12.013 · Cited by 166
Artifact removal from electroencephalograms using a hybrid BSS-SVM algorithm
Shoker, L., Sanei, S., & Chambers, J. (2005) · IEEE Signal Processing Letters · doi:10.1109/lsp.2005.855539 · Cited by 160
Listen, You are Writing! Speeding up Online Spelling with a Dynamic Auditory BCI
Schreuder, M., Rost, T., & Tangermann, M. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00112 · Cited by 150
Self-citationArtifact reduction in magnetoneurography based on time-delayed second-order correlations
Ziehe, A., Muller, K.-R., Nolte, G., Mackert, B.-M., & Curio, G. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.817622 · Cited by 140
Muscle Artifact Removal from Human Sleep EEG by Using Independent Component Analysis
Crespo‐García, M., Atienza, M., & Cantero, J. L. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9442-y · Cited by 138
Combining sparsity and rotational invariance in EEG/MEG source reconstruction
Haufe, S., Nikulin, V. V., Ziehe, A., Müller, K.-R., & Nolte, G. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.246 · Cited by 130 · cited 1×
“We considered 2142 locations arranged in a 1 cm spaced 3D-grid, formulated the forward problem according to [41–43] and sought the source distribution with minimal l 2 -norm (i.e. the ‘simplest’ solution) [44, 45].”
MethodElectromyogenic Artifacts and Electroencephalographic Inferences
Shackman, A. J., McMenamin, B. W., Slagter, H. A., Maxwell, J. S., Greischar, L. L., & Davidson, R. J. (2009) · Brain Topography · doi:10.1007/s10548-009-0079-4 · Cited by 125
Halder, S., Bensch, M., Mellinger, J., Bogdan, M., Kübler, A., Birbaumer, N., & Rosenstiel, W. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/82069 · Cited by 123
Hill, N. J., Lal, T. N., Schroder, M., Hinterberger, T., Wilhelm, B., Nijboer, F., Mochty, U., Widman, G., Elger, C., Scholkopf, B., et al. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875548 · Cited by 119
Meinecke, F. C., Ziehe, A., Kawanabe, M., & Müller, K. R. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805480 · Cited by 112
Removal of EEG Noise and Artifact Using Blind Source Separation
Fitzgibbon, S. P., Powers, D. M. W., Pope, K. J., & Clark, C. R. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3180556926 · Cited by 106
Content-specific coordination of listeners' to speakers' EEG during communication
Kuhlen, A. K., Allefeld, C., & Haynes, J.-D. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00266 · Cited by 87
Self-citationViola, F. C., Vos, M. D., Hine, J. E., Sandmann, P., Bleeck, S., Eyles, J., & Debener, S. (2012) · Hearing Research · doi:10.1016/j.heares.2011.12.010 · Cited by 79
Bigdely-Shamlo, N., Kreutz-Delgado, K., Kothe, C., & Makeig, S. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610881 · Cited by 78
Analytic expansion of the EEG lead field for realistic volume conductors
Nolte, G., & Dassios, G. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/16/010 · Cited by 78
Classification of independent components of EEG into multiple artifact classes
Frølich, L., Andersen, T., & Mørup, M. (2014) · Psychophysiology · doi:10.1111/psyp.12290 · Cited by 64
Improving speed and accuracy of brain-computer interfaces using readiness potential features
Krauledat, M., Dornhege, G., Blankertz, B., Losch, F., Curio, G., & Müller, K. R. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404253 · Cited by 54
Optimizing the Performances of a P300-Based Brain–Computer Interface in Ambulatory Conditions
Castermans, T., Duvinage, M., Petieau, M., Hoellinger, T., Saedeleer, C. D., Seetharaman, K., Bengoetxea, A., Cheron, G. A., & Dutoit, T. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2179421 · Cited by 44
Cited by
ICLabel: An automated electroencephalographic independent component classifier, dataset, and website
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.026 · Cited by 2,267
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
Gabard-Durnam, L. J., Mendez Leal, A. S., Wilkinson, C. L., & Levin, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00097 · Cited by 535
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Metadata
- Authors
- Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-05-19
- Volume
- 11
- Issue
- 3
- Pages
- 035013
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1994321338
- Cited by
- 327
- References
- 48
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.