A lower limb exoskeleton control system based on steady state visual evoked potentials
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We have developed an asynchronous brain-machine interface (BMI)-based lower limb exoskeleton control system based on steady-state visual evoked potentials (SSVEPs). APPROACH: By decoding electroencephalography signals in real-time, users are able to walk forward, turn right, turn left, sit, and stand while wearing the exoskeleton. SSVEP stimulation is implemented with a visual stimulation unit, consisting of five light emitting diodes fixed to the exoskeleton. A canonical correlation analysis (CCA) method for the extraction of frequency information associated with the SSVEP was used in combination with k-nearest neighbors. MAIN RESULTS: Overall, 11 healthy subjects participated in the experiment to evaluate performance. To achieve the best classification, CCA was first calibrated in an offline experiment. In the subsequent online experiment, our results exhibit accuracies of 91.3 ± 5.73%, a response time of 3.28 ± 1.82 s, an information transfer rate of 32.9 ± 9.13 bits/min, and a completion time of 1100 ± 154.92 s for the experimental parcour studied. SIGNIFICANCE: The ability to achieve such high quality BMI control indicates that an SSVEP-based lower limb exoskeleton for gait assistance is becoming feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 2×
“common spatial patterns (CSP) [12] can classify SSVEP with low error without time delay.”
BackgroundMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990 · cited 1×
“used in BMI research is the modulation of sensorimotor rhythms through motor imagery (MI) [9].”
MethodBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Self-citationEEG differences between eyes-closed and eyes-open resting conditions
Barry, R. J., Clarke, A. R., Johnstone, S. J., Magee, C. A., & Rushby, J. A. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.07.028 · Cited by 1,077
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047 · cited 1×
“Furthermore, significant challenges still exist for the development of a lower limb exoskeleton that can integrate with the user’s neuromusculoskeletal system [43].”
BackgroundRegularizing Common Spatial Patterns to Improve BCI Designs: Unified Theory and New Algorithms
Lotte, F., & Guan, C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2082539 · Cited by 1,045
Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos
Picton, T. W., John, M. S., Dimitrijevic, A., & Purcell, D. (2003) · International Journal of Audiology · doi:10.3109/14992020309101316 · Cited by 846
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Neurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674
Self-citationA Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654 · cited 1×
“SSVEPs can be elicited by repetitive visual stimuli at frequencies in the 1 to 100 Hz range [23].”
BackgroundIntroduction to machine learning for brain imaging
Lemm, S., Blankertz, B., Dickhaus, T., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.004 · Cited by 630
Self-citationControl of an Electrical Prosthesis With an SSVEP-Based BCI
Muller-Putz, G. R., & Pfurtscheller, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897815 · Cited by 589
Pfurtscheller, G., Müller, G. R., Pfurtscheller, J., Gerner, H. J., & Rupp, R. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00947-9 · Cited by 548
Müller, K.-R., Tangermann, M., Dornhege, G., Krauledat, M., Curio, G., & Blankertz, B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.09.022 · Cited by 474
Self-citationVisual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449 · cited 1×
“the highly popular P300 spellers based on visual or auditory paradigms (cf [10, 11]).”
BackgroundBrain-Controlled Wheelchairs: A Robotic Architecture
Carlson, T., & del R. Millan, J. (2013) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2012.2229936 · Cited by 432
EEG-based communication: improved accuracy by response verification
Wolpaw, J. R., Ramoser, H., McFarland, D. J., & Pfurtscheller, G. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.712231 · Cited by 396
Human Cerebral Activation during Steady-State Visual-Evoked Responses
Pastor, M. A., Artieda, J., Arbizu, J., Valencia, M., & Masdeu, J. C. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-37-11621.2003 · Cited by 324
An SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia
Ortner, R., Allison, B. Z., Korisek, G., Gaggl, H., & Pfurtscheller, G. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2076364 · Cited by 281 · cited 1×
“Other research has shown the feasibility of electrical hand prosthesis control with SSVEPs for healthy subjects in which flickering lights were mounted on the surface of the neuroprosthesis [21], and patients with tetraplegia [22].”
BackgroundA Novel Bayesian Framework for Discriminative Feature Extraction in Brain-Computer Interfaces
Suk, H.-I., & Lee, S.-W. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.69 · Cited by 241
Self-citationVisual Evoked Responses During Standing and Walking
Gramann, K., Gwin, J. T., Bigdely-Shamlo, N., Ferris, D. P., & Makeig, S. (2010) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2010.00202 · Cited by 229
Asynchronous BCI control using high-frequency SSVEP
Diez, P. F., Mut, V. A., Avila Perona, E. M., & Laciar Leber, E. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-39 · Cited by 212
Nilsson, A., Vreede, K., Häglund, V., Kawamoto, H., Sankai, Y., & Borg, J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-92 · Cited by 206 · cited 1×
“Also applications of BMI systems in stroke recovery and rehabilitation (see [37]) and hybrid assertive limb systems [38, 39] have been developed.”
BackgroundHigh accuracy decoding of user intentions using EEG to control a lower-body exoskeleton
Kilicarslan, A., Prasad, S., Grossman, R. G., & Contreras-Vidal, J. L. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610821 · Cited by 196
Brain-computer interface controlled robotic gait orthosis
Do, A. H., Wang, P. T., King, C. E., Chun, S. N., & Nenadic, Z. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-111 · Cited by 189
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
Suppression of axonal conduction by sinusoidal stimulation in rat hippocampus in vitro
Jensen, A. L., & Durand, D. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/001 · Cited by 180
How Many People Could Use an SSVEP BCI?
Guger, C., Allison, B. Z., Großwindhager, B., Prückl, R., Hintermüller, C., Kapeller, C., Bruckner, M., Krausz, G., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00169 · Cited by 176 · cited 1×
“The advantages of the proposed asynchronous BMI system is that many people can use SSVEPs very easily and with high accuracy [53] as it only requires ocular movements and attention to visual stimuli.”
BackgroundDivergence-Based Framework for Common Spatial Patterns Algorithms
Samek, W., Kawanabe, M., & Muller, K.-R. (2014) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2290621 · Cited by 174
Tsukahara, A., Hasegawa, Y., Eguchi, K., & Sankai, Y. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2364618 · Cited by 174 · cited 1×
“Also applications of BMI systems in stroke recovery and rehabilitation (see [37]) and hybrid assertive limb systems [38, 39] have been developed.”
BackgroundA regularized discriminative framework for EEG analysis with application to brain–computer interface
Tomioka, R., & Müller, K.-R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.045 · Cited by 167
Self-citationA user-friendly SSVEP-based brain–computer interface using a time-domain classifier
Luo, A., & Sullivan, T. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026010 · Cited by 161 · cited 1×
“Stimuluslocked inter-trace correlation (SLIC) is suitable for irregular stimulus patterns [25].”
BackgroundKim, I.-H., Kim, J.-W., Haufe, S., & Lee, S. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016001 · Cited by 157
Self-citationAnalysis of Multimodal Neuroimaging Data
Biessmann, F., Plis, S., Meinecke, F. C., Eichele, T., & Muller, K.-R. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2170675 · Cited by 155 · cited 1×
“CCA (see [27, 46, 47]) is a multivariable statistical method that finds a pair of linear combinations such that the correlation between two canonical variables X and Y is maximized.”
BackgroundParini, S., Maggi, L., Turconi, A. C., & Andreoni, G. (2009) · Computational Intelligence and Neuroscience · doi:10.1155/2009/864564 · Cited by 126 · cited 1×
“However, long training times may be needed to achieve high accuracy [24].”
BackgroundAn Efficient ERP-Based Brain-Computer Interface Using Random Set Presentation and Face Familiarity
Yeom, S.-K., Fazli, S., Müller, K., & Lee, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111157 · Cited by 117
Self-citationAssisted navigation for a brain-actuated intelligent wheelchair
Lopes, A., Pires, G., & Nunes, U. (2012) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2012.11.002 · Cited by 112
Operation of a brain-computer interface walking simulator for individuals with spinal cord injury
King, C., Wang, P. T., Chui, L. A., Do, A. H., & Nenadić, Z. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-77 · Cited by 110
Dähne, S., Meinecke, F. C., Haufe, S., Höhne, J., Tangermann, M., Müller, K.-R., & Nikulin, V. V. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.079 · Cited by 108
Self-citationRea, M., Rana, M., Lugato, N., Terekhin, P., Gizzi, L., Brötz, D., Fallgatter, A. J., Birbaumer, N., Sitaram, R., & Carìa, A. (2014) · Neurorehabilitation and neural repair · doi:10.1177/1545968313520410 · Cited by 102
LASSO based stimulus frequency recognition model for SSVEP BCIs
Zhang, Y., Jin, J., Qing, X., Wang, B., & Wang, X. (2011) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.02.002 · Cited by 101
Contreras-Vidal, J. L., & Grossman, R. G. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609816 · Cited by 97
Fazli, S., Dähne, S., Samek, W., Bieszmann, F., & Müller, K. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2413993 · Cited by 97 · cited 1×
“CCA (see [27, 46, 47]) is a multivariable statistical method that finds a pair of linear combinations such that the correlation between two canonical variables X and Y is maximized.”
BackgroundSelf-citationThe Human Auditory Steady-State Evoked Potentials
Plourde, G., Stapells, D. R., & Picton, T. W. (1991) · Acta Oto-Laryngologica · doi:10.3109/00016489109136793 · Cited by 83 · cited 1×
“a significant increase in EEG power at the stimulation frequency [48, 49]).”
BackgroundApplications of Brain–Machine Interface Systems in Stroke Recovery and Rehabilitation
Venkatakrishnan, A., Francisco, G. E., & Contreras-Vidal, J. L. (2014) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-014-0051-4 · Cited by 78 · cited 1×
“Also applications of BMI systems in stroke recovery and rehabilitation (see [37]) and hybrid assertive limb systems [38, 39] have been developed.”
BackgroundNeural decoding of expressive human movement from scalp electroencephalography (EEG)
Cruz-Garza, J. G., Hernandez, Z., Nepaul, S., Bradley, K. K., & Contreras-Vidal, J. L. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00188 · Cited by 71
Brain controlled robotic exoskeleton for neurorehabilitation
McDaid, A., Song, X., & Xie, S. Q. (2013) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2013.6584231 · Cited by 32
Contreras-Vidal, J. L. (2014) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2014.6974126 · Cited by 5
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
A Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 508
Brain-Controlled Robotic Arm System Based on Multi-Directional CNN-BiLSTM Network Using EEG Signals
Jeong, J.-H., Shim, K.-H., Kim, D.-J., & Lee, S.-W. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2981659 · Cited by 292
Self-citationKwak, N.-S., Müller, K.-R., & Lee, S.-W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172578 · Cited by 272
Self-citation
Metadata
- Authors
- Kwak, N.-S., Müller, K.-R., & Lee, S.-W.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-08-17
- Volume
- 12
- Issue
- 5
- Pages
- 056009
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2126013367
- Cited by
- 221
- References
- 53
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.