Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
A new method for fabrication of microelectrode arrays comprised of traditional implant materials is presented. The main construction principle is the use of spun-on medical grade silicone rubber as insulating substrate material and platinum foil as conductor (tracks, pads and electrodes). The silicone rubber and the platinum foil are patterned by laser cutting using an Nd:YAG laser and a microcontroller-driven, stepper-motor operated x-y table. The method does not require expensive clean room facilities and offers an extremely short design-to-prototype time of below 1 day. First prototypes demonstrate a minimal achievable feature size of about 30 microm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 1×
“In the late 1960s, micromachining methods based on photolithography intentionally developed for production of integrated circuits were applied towards making high-density, high-channel electrode arrays based on silicon substrates [3].”
MethodMicromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · cited 1×
“, Not approved materials involved silicon, platinum, platinum/iridium, platinum, silicone rubber, polyimide, PTFE, thin film or electroplated stainless steel silicone PTFE, parylene) metals, doped semiconductors, rubber, PTFE) electrical conductive polymers Equipment Welder, inexpensive tools Laser, x–y table (spin co…”
BackgroundCui, X., Hetke, J. F., Wiler, J. A., Anderson, D. J., & Martin, D. C. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00637-9 · Cited by 330 · cited 1×
“Combining silicon and platinum spheres [13] of stainless steel wires [14] with conductive polymers [17]”
BackgroundNeural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S. J., Evans, D. A., Levy, K. L., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Suaning, G. J., & Lovell, N. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909646 · Cited by 164 · cited 1×
“In the present study, we investigate a dramatically simplified approach, aiming at the fabrication of high-channel retinal electrode arrays as one component of implantable 100-channel visual prostheses [8].”
MethodSelf-citationHigh density interconnects and flexible hybrid assemblies for active biomedical implants
Meyer, J.-U., Stieglitz, T., Scholz, O., Haberer, W., & Beutel, H. (2001) · IEEE Transactions on Advanced Packaging · doi:10.1109/6040.938305 · Cited by 145 · cited 1×
“This can be done either by micro-welding of wires [7] or by micro-riveting, as described in [11] (implying that the contact pad has a hole for the rivet as shown in figure 8).”
Functional electrical stimulation
Rushton, D. N. (1997) · Physiological Measurement · doi:10.1088/0967-3334/18/4/001 · Cited by 101
Neuroprostheses to treat neurogenic bladder dysfunction: current status and future perspectives
Rijkhoff, N. J. M. (2004) · Child's Nervous System · doi:10.1007/s00381-003-0859-1 · Cited by 66 · cited 1×
“Functional electrical stimulation restores lost body function in everyday life for a large number of patients using implanted devices, such as pacemakers, defibrillators, bladder stimulators, implants for managing pain, tremor, epilepsy and restoration of hearing, etc [1, 2].”
BackgroundThin-film multielectrode arrays for a cochlear prosthesis
Shamma-Donoghue, S. A., May, G. A., Cotter, N. E., White, R. L., & Simmons, F. B. (1982) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1982.20671 · Cited by 56 · cited 1×
“Twenty years later, microelectrode arrays based on flexible polymer substrates such as polyimide were investigated [4].”
BackgroundStieglitz, T. (2004) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2004.075 · Cited by 30 · cited 1×
“Biocompatibility studies involving the dry etching of other polymers such as polyimide (unpublished) and parylene [18] indicate that with careful selection of gasses used in the formation of plasma, a non-cytotoxic surface remains.”
BackgroundSadhir, R. K., James, W. J., Yasuda, H. K., Sharma, A. K., Nichols, M. F., & Haln, A. W. (1981) · Biomaterials · doi:10.1016/0142-9612(81)90064-8 · Cited by 28 · cited 1×
“Considering that the adhesion of Type A adhesive to platinum is not long lasting [10], the fact that MED1000 can easily be dry-etched using a plasma might become important for future optimization of the technology presented here.”
BackgroundElectrical stimulation of the brain. I. Electrodes and electrode arrays.
Rh, P., Bullara, L. A., & Talalla, A. (1975) · PubMed · Cited by 26
Micromachining of flexible neural implants with low-ohmic wire traces using electroplating
Gross, M., Altpeter, D., Stieglitz, T., Schüettler, M., & Meyer, J.-U. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00768-3 · Cited by 20 · cited 1×
“Electroplating of gold has proven to be practical [5], but when used as an electrode surface, requires an additional metal such as platinum to be deposited to gain appropriate charge injection”
Background
Cited by
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
3D printing: an emerging tool for novel microfluidics and lab-on-a-chip applications
Yazdi, A. A., Popma, A., Wong, W., Nguyen, T., Pan, Y., & Xu, J. (2016) · Microfluidics and Nanofluidics · doi:10.1007/s10404-016-1715-4 · Cited by 307
Organic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Substrate dependent stability of conducting polymer coatings on medical electrodes
Green, R. A., Hassarati, R. T., Bouchinet, L., Lee, C. S., Cheong, G. L. M., Yu, J. F., Dodds, C. W., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.017 · Cited by 205
Self-citationImplantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202
Metadata
- Authors
- Schuettler, M., Stiess, S., King, B. V., & Suaning, G. J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2005-02-23
- Volume
- 2
- Issue
- 1
- Pages
- S121-S128
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2112896847
- Cited by
- 163
- References
- 14
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.