Cited by 14Neuroscience and Neural EngineeringNerve injury and regenerationAnalog and Mixed-Signal Circuit Design

64-channel double-layered sieve electrode with increased porosity for improved axon regeneration and high spatial resolution,

Jinwoo Jeong, Jung, Woohyun, Ockchul Kim, Jun-Uk Chu, Inchan Youn, Keehoon Kim, Sang Rok Oh, Jong Woong Park +1 more·2016·2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob)

Abstract

Double-layered sieve-type neural electrode with high channel density is suggested for peripheral nerve interface. The neural electrode has double channel density due to its two separated metal layers including electrodes and distribution interconnects. Also it can be utilized to acquire and stimulate throughout the whole nerve cross-section. The measurement results of the electrochemical impedance confirm that the fabricated neural electrode has the neural signal recording feasibility. In-vivo implantation of the device is performed and functional recovery has been investigated. From the preliminary experimental results, new improved device design with higher porosity is suggested for next step.

Integrity signals

Registry

Crossref · 10.1109/biorob.2016.7523786

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Sieve electrodes can be created with up to 64 electrodes.

    “It has been shown that sieve electrodes can be created with up to 64 electrodes (Jeong et al., 2016).”

    From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Jeong et al., 2016

  • A recent double-layered sieve electrode with 64 channels implanted in the rat sciatic nerve had unfavorable results after 4 months in terms of motor function, attributed to inadequate porosity.

    “A recent design incorporated 64 channels in a double-layered sieve electrode in order to double interconnection density and increase spatial resolution. It was implanted in the rat sciatic nerve. The results were not favorable after 4 months in terms of motor function, which was attributed to inadequate porosity [121].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Jeong, J., Jung, W., Kim, O., Chu, J.-U., Youn, I., Kim, K., Oh, S. R., Park, J. W., & Kim, J.
Affiliations
  • Korea Institute of Science and Technology (KR)
  • Korea Institute of Machinery & Materials (KR)
  • Korea University (KR)
Venue
2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob)
Publisher
IEEE
Published
2016-06
Pages
1148-1153
ISSN
2155-1774 (ISSN-L)
OpenAlex
W2505331947
Cited by
14
References
14
Citations by year
2024: 4 · 2021: 2 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 1
FWCI
8.84
Type
conference paper
Language
en
Open access
closed
Locations
  • IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) (publishedVersion)
  • Open Access System for Information Sharing (Pohang University of Science and Technology) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
Keywords
axon regeneration, peripheral nerve interfaces, neural recording, electrochemical impedance, in vivo implantation, functional recovery, electrode porosity, neurostimulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review