A new approach towards a minimal invasive retina implant
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The possibility of using retina implants ('retinal prostheses') for the restoration of basic orientation in blind patients suffering from distal retinal diseases is presently under investigation by at least 18 independent project groups worldwide. It is a common feature of all implants to bypass degenerated retinal layers and to transfer visual information into the retinal network either by direct electrical stimulation or by neurotransmitter release. Contemporary implant designs are differing in the position of stimulating electrodes (epiretinal, subretinal, external) and the anatomical arrangement of implant components (intraocular, extraocular). The latter is of high relevance with regard to possible implant-tissue interactions and biological reactions. During the last few years new types of implants appeared that reduce intraocular components which are now deposited on the outer scleral surface or even in extraorbital position. The extreme of this trend are completely extraocular implants with transchoroidal or extraocular stimulation of the retina. The new type of implant presented in this paper combines the principle of direct retinal stimulation and minimal invasive implantation in a way that stimulating electrodes are the only implant component penetrating the eye via sclera, choroid and retinal pigment epithelium. All other device elements are positioned in extraocular position. The new concept necessitates a paradigmatic change about surgical handling of the choroid and multiple penetrations of the eye. Successful data about this type of retinal prosthesis are already available from long-term observation in non-human primates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
A model for intracortical visual prosthesis research
Troyk, P., Bak, M., Berg, J., Bradley, D., Cogan, S., Erickson, R., Kufta, C., McCreery, D., Schmidt, E., & Towle, V. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07308.x · Cited by 166
MORPHOMETRIC ANALYSIS OF THE MACULA IN EYES WITH DISCIFORM AGE-RELATED MACULAR DEGENERATION
KIM, S. Y., SADDA, S., PEARLMAN, J., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00012 · Cited by 158
KIM, S. Y., SADDA, S., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00011 · Cited by 117
Dagnelie, G., Barnett, D., Humayun, M. S., & Thompson, R. W. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0157 · Cited by 90
Cited by
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Biomimetic electrochemistry from conducting polymers. A review
Otero, T. F., Martinez, J. G., & Arias-Pardilla, J. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.03.097 · Cited by 292
Subretinal injection: a review on the novel route of therapeutic delivery for vitreoretinal diseases
Peng, Y., Tang, L., & Zhou, Y. (2017) · Ophthalmic Research · doi:10.1159/000479157 · Cited by 175
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices
Vanhoestenberghe, A., & Donaldson, N. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/031002 · Cited by 140
Virtual electrodes by current steering in retinal prostheses
Dumm, G., Fallon, J. B., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15391 · Cited by 63
“This is realized by an implantable electrode array which is placed at either one of four locations: epiretinal 4-6 , subretinal 7, 8 , suprachoroidal 9, 10 and trans-scleral 11, 12 .”
Background
Metadata
- Authors
- Gerding, H.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2007-02-20
- Volume
- 4
- Issue
- 1
- Pages
- S30-S37
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2023348640
- Cited by
- 46
- References
- 7
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new approach towards a minimal invasive retina implant. https://app.cochat.ai/papers/10.1088/1741-2560/4/1/s05
- The paper
- Gerding, H. (2007). A new approach towards a minimal invasive retina implant. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/4/1/s05
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.