Abstract

Neural stimulation with high spatial and temporal precision is desirable both for studying the real-time dynamics of neural networks and for prospective clinical treatment of neurological diseases. Optical stimulation of genetically targeted neurons expressing the light sensitive channel protein Channelrhodopsin (ChR2) has recently been reported as a means for millisecond temporal control of neuronal spiking activities with cell-type selectivity. This offers the prospect of enabling local delivery of optical stimulation and the simultaneous monitoring of the neural activity by electrophysiological means, both in the vicinity of and distant to the stimulation site. We report here a novel dual-modality hybrid device, which consists of a tapered coaxial optical waveguide ('optrode') integrated into a 100 element intra-cortical multi-electrode recording array. We first demonstrate the dual optical delivery and electrical recording capability of the single optrode in in vitro preparations of mouse retina, photo-stimulating the native retinal photoreceptors while recording light-responsive activities from ganglion cells. The dual-modality array device was then used in ChR2 transfected mouse brain slices. Specifically, epileptiform events were reliably optically triggered by the optrode and their spatiotemporal patterns were simultaneously recorded by the multi-electrode array.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/6/5/055007

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Millisecond-timescale, genetically targeted optical control of neural activity

    Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861 · cited 2×

    “Various light delivery schemes have been reported, to match the excitation spectrum of ChR2 in the blue, including band-filtered white light [11, 56], light emitting diodes (LED) [12] or laser-coupled optics [39] for in vitro applications, as well as direct epicranial LED implantation [29] for in vivo applications.”
    BackgroundSelf-citation
  • Deep Brain Stimulation for Treatment-Resistant Depression

    Mayberg, H. S., Lozano, A. M., Voon, V., McNeely, H. E., Seminowicz, D., Hamani, C., Schwalb, J. M., & Kennedy, S. H. (2005) · Neuron · doi:10.1016/j.neuron.2005.02.014 · Cited by 4,059 · cited 1×

    “…by means of injecting electrical current through brain tissue has been a powerful tool in electrophysiology [17] and clinical neuroscience [33, 38], in spite of the uncertainties associated with complex current paths, non-selective depolarization of axons, dendrites and neuronal cell…”
  • Neuronal ensemble control of prosthetic devices by a human with tetraplegia

    Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×

    “Since the standard ‘non-optical’ MEAs used as the basis for our devices are extensively employed in in vivo extracellular recording, especially in primates [46], we suggest that our optrode–MEA constructs may also be applicable to in vivo brain structures such as the motor-cortex [1, 27], where selective activation or…”
    Background
  • Channelrhodopsin-2, a directly light-gated cation-selective membrane channel

    Nagel, G., Szellas, T., Huhn, W., Kateriya, S., Adeishvili, N., Berthold, P., Ollig, D., Hegemann, P., & Bamberg, E. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1936192100 · Cited by 2,663 · cited 1×

    “Direct optical stimulation of neural cells in brain tissue genetically modified by expressing channelrhodopsin-2 (ChR2) has recently been achieved [11, 35, 56] and applied”
    Background
  • Theory of Diffraction by Small Holes

    Bethe, H. A. (1944) · Physical Review · doi:10.1103/physrev.66.163 · Cited by 2,607

  • Neuronal Avalanches in Neocortical Circuits

    Beggs, J. M., & Plenz, D. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-35-11167.2003 · Cited by 2,325 · cited 1×

    “The onset time of the waves was determined by measuring the delay between stimulus and a triggered-wave voltage amplitude value of 150 μV [6].”
    Method
  • Optical stethoscopy: Image recording with resolution λ/20

    Pohl, D. W., Denk, W., & Lanz, M. (1984) · Applied Physics Letters · doi:10.1063/1.94865 · Cited by 2,040

  • Multimodal fast optical interrogation of neural circuitry

    Zhang, F., Wang, L.-P., Brauner, M., Liewald, J. F., Kay, K., Watzke, N., Wood, P. G., Bamberg, E., Nagel, G., Gottschalk, A., et al. (2007) · Nature · doi:10.1038/nature05744 · Cited by 1,738 · cited 2×

    “Various light delivery schemes have been reported, to match the excitation spectrum of ChR2 in the blue, including band-filtered white light [11, 56 ], light emitting diodes (LED) [12] or laser-coupled optics [39 ]f orin vitro applications, as well as direct epicranial LED implantation [29 ]f orin vivo applications.”
    Self-citation
  • Breaking the Diffraction Barrier: Optical Microscopy on a Nanometric Scale

    Betzig, E., Trautman, J. K., Harris, T. D., Weiner, J. S., & Kostelak, R. L. (1991) · Science · doi:10.1126/science.251.5000.1468 · Cited by 1,534 · cited 1×

    “It was fabricated from a multimode optical fiber (Fiber Instrument Sales Inc., 62.5 μm core, 125 μm cladding), whose bare end was cleaved and cleaned with isopropanol before further processing, to remove organic substances on the optical fiber after stripping the outer polymer jacket.”
    MethodInfluential
  • Instant neural control of a movement signal

    Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409 · cited 1×

    “Since the standard ‘non-optical’ MEAs used as the basis for our devices are extensively employed in in vivo extracellular recording, especially in primates [ 46 ], we suggest that our optrode–MEA constructs may also be applicable to in vivo brain structures such as the motor-cortex [1, 27], where selective activation…”

Show all 52 references

Cited by

Metadata

Authors
Zhang, J., Laiwalla, F., Kim, J. A., Urabe, H., Van Wagenen, R., Song, Y.-K., Connors, B. W., Zhang, F., Deisseroth, K., & Nurmikko, A. V.
Venue
Journal of Neural Engineering
Published
2009-09-01
Volume
6
Issue
5
Pages
055007
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2144284928
Cited by
193
References
52
FWCI
6.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.