Abstract
Studying brain function and its local circuit dynamics requires neural interfaces that can record and stimulate the brain with high spatiotemporal resolution. Optogenetics, a technique that genetically targets specific neurons to express light-sensitive channel proteins, provides the capability to control central nervous system neuronal activity in mammals with millisecond time precision. This technique enables precise optical stimulation of neurons and simultaneous monitoring of neural response by electrophysiological means, both in the vicinity of and distant to the stimulation site. We previously demonstrated, in vitro, the dual capability (optical delivery and electrical recording) while testing a novel hybrid device (optrode-MEA), which incorporates a tapered coaxial optical electrode (optrode) and a 100 element microelectrode array (MEA). Here we report a fully chronic implant of a new version of this device in ChR2-expressing rats, and demonstrate its use in freely moving animals over periods up to 8 months. In its present configuration, we show the device delivering optical excitation to a single cortical site while mapping the neural response from the surrounding 30 channels of the 6 × 6 element MEA, thereby enabling recording of optically modulated single-unit and local field potential activity across several millimeters of the neocortical landscape.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551 · cited 1×
“S Online supplementary data available from stacks.iop.org/JNE/9/016001/mmedia (Some figures in this article are in colour only in the electronic version)”
Regulation of parkinsonian motor behaviours by optogenetic control of basal ganglia circuitry
Kravitz, A. V., Freeze, B. S., Parker, P. R. L., Kay, K., Thwin, M. T., Deisseroth, K., & Kreitzer, A. C. (2010) · Nature · doi:10.1038/nature09159 · Cited by 1,885 · cited 1×
“Another commercially available optrode recording unit (NeuroNexus) combines the multi-shank silicon probes with a bare optical fiber [9, 27].”
Self-citationHisted, M. H., Bonin, V., & Reid, R. C. (2009) · Neuron · doi:10.1016/j.neuron.2009.07.016 · Cited by 604
An optogenetic toolbox designed for primates
Diester, I., Kaufman, M. T., Mogri, M., Pashaie, R., Goo, W., Yizhar, O., Ramakrishnan, C., Deisseroth, K., & Shenoy, K. V. (2011) · Nature Neuroscience · doi:10.1038/nn.2749 · Cited by 443
Self-citationSingle-Unit Stability Using Chronically Implanted Multielectrode Arrays
Dickey, A. S., Suminski, A., Amit, Y., & Hatsopoulos, N. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90920.2008 · Cited by 234 · cited 1×
“In one of the comprehensive studies on this issue, the authors estimated that about 39% of single units were stable across 15 days in their primate recordings [31].”
OlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181 · cited 1×
“Even if much less of a hindrance than the interference which is always present in the case of recording during direct electrical stimulation [29, 30], optical artifacts are caused by direct photoelectronic or photoinduced temperature effects depending on the optoelectronic properties of materials at the recording inte…”
Cited by
Optogenetic investigation of neural circuits underlying brain disease in animal models
Tye, K. M., & Deisseroth, K. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3171 · Cited by 745
Self-citationNovel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565
Self-citationNext-generation interfaces for studying neural function
Frank, J. A., Antonini, M.-J., & Anikeeva, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0198-8 · Cited by 241
A coaxial optrode as multifunction write-read probe for optogenetic studies in non-human primates
Ozden, I., Wang, J., Lu, Y., May, T., Lee, J., Goo, W., O'Shea, D. J., Kalanithi, P., Diester, I., Diagne, M., et al. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.06.011 · Cited by 97
Self-citation
Metadata
- Authors
- Wang, J., Wagner, F., Borton, D. A., Zhang, J., Ozden, I., Burwell, R. D., Nurmikko, A. V., van Wagenen, R., Diester, I., & Deisseroth, K.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-12-07
- Volume
- 9
- Issue
- 1
- Pages
- 016001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2109230507
- Cited by
- 169
- References
- 6
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integrated device for combined optical neuromodulation and electrical recording for chronic in vivo applications. https://app.cochat.ai/papers/10.1088/1741-2560/9/1/016001
- The paper
- Wang, J., Wagner, F., Borton, D. A., Zhang, J., Ozden, I., Burwell, R. D., Nurmikko, A. V., van Wagenen, R., Diester, I., & Deisseroth, K. (2012). Integrated device for combined optical neuromodulation and electrical recording for chronic in vivo applications. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/9/1/016001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.