A finite element analysis of the effect of electrode area and inter-electrode distance on the spatial distribution of the current density in tDCS
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
We investigated the effect of electrode area and inter-electrode distance on the spatial distribution of the current density in transcranial direct current stimulation (tDCS). For this purpose, we used the finite element method to compute the distribution of the current density in a four-layered spherical head model using various electrode montages, corresponding to a range of electrode sizes and inter-electrode distances. We found that smaller electrodes required slightly less current to achieve a constant value of the current density at a reference point on the brain surface located directly under the electrode center. Under these conditions, smaller electrodes also produced a more focal current density distribution in the brain, i.e. the magnitude of the current density fell more rapidly with distance from the reference point. The combination of two electrodes with different areas produced an asymmetric current distribution that could lead to more effective and localized neural modulation under the smaller electrode than under the larger one. Focality improved rapidly with decreasing electrode size when the larger electrode sizes were considered but the improvement was less marked for the smaller electrode sizes. Also, focality was not affected significantly by inter-electrode distance unless two large electrodes were placed close together. Increasing the inter-electrode distance resulted in decreased shunting of the current through the scalp and the cerebrospinal fluid, and decreasing electrode area resulted in increased current density on the scalp under the edges of the electrode. Our calculations suggest that when working with conventional electrodes (25-35 cm(2)), one of the electrodes should be placed just 'behind' the target relative to the other electrode, for maximum current density on the target. Also electrodes with areas in the range 3.5-12 cm(2) may provide a better compromise between focality and current density in the scalp than the traditional electrodes. Finally, the use of multiple small return electrodes may be more efficient than the use of a single large return electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656 · cited 6×
“In the traditional electrode montage E1 is placed over the hand representation in the left primary motor cortex and E2 above the contralateral eyebrow (see, for instance (Nitsche and Paulus, 2000; Nitsche and Paulus, 2001)).”
BackgroundInfluentialTranscranial direct current stimulation: State of the art 2008
Nitsche, M. A., Cohen, L. G., Wassermann, E. M., Priori, A., Lang, N., Antal, A., Paulus, W., Hummel, F., Boggio, P. S., Fregni, F., et al. (2008) · Brain Stimulation · doi:10.1016/j.brs.2008.06.004 · Cited by 3,057 · cited 2×
“By 2008, more than 2000 subjects had been stimulated worldwide using a current of 1 mA without clinically relevant side effects (Nitsche et al 2008).”
BackgroundSustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Gandiga, P. C., Hummel, F. C., & Cohen, L. G. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.12.003 · Cited by 1,474
Datta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290 · cited 3×
“…been published, either with point-like electrodes (Ferdjallah et al 1996) or with more realistic electrode and/or head models (Stecker 2005, Miranda et al 2006, Wagner et al 2007, Datta et al 2008, Datta et al 2009, Faria et al 2009, Miranda et al 2009, Sadleir et al 2010, Parazzini et al 2011).”
Safety aspects of transcranial direct current stimulation concerning healthy subjects and patients
Poreisz, C., Boros, K., Antal, A., & Paulus, W. (2007) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2007.01.004 · Cited by 1,099 · cited 1×
“To date, all studies concerning the safety of tDCS indicate that the application of a current of 1 mA for periods up to 20 min using electrodes whose area is 25 or 35 cm2 has no significant adverse effects (Nitsche et al 2003, Iyer et al 2005, Poreisz et al 2007).”
BackgroundModeling the current distribution during transcranial direct current stimulation
Miranda, P. C., Lomarev, M., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.009 · Cited by 762
Self-citationBikson, M., Inoue, M., Akiyama, H., Deans, J. K., Fox, J. E., Miyakawa, H., & Jefferys, J. G. R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.055772 · Cited by 743 · cited 3×
“The choice of a current density “threshold” for calculating measures of focality is somewhat arbitrary in tDCS since the effect of stimulation on the neuronal membrane varies linearly with stimulation intensity (Bikson et al., 2004).”
BackgroundMethod
Cited by
Evidence-based guidelines on the therapeutic use of transcranial direct current stimulation (tDCS)
Lefaucheur, J.-P., Antal, A., Ayache, S. S., Benninger, D. H., Brunelin, J., Cogiamanian, F., Cotelli, M., De Ridder, D., Ferrucci, R., Langguth, B., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.10.087 · Cited by 1,826
A technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Self-citationAntal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationDirect effects of transcranial electric stimulation on brain circuits in rats and humans
Vöröslakos, M., Takeuchi, Y., Brinyiczki, K., Zombori, T., Oliva, A., Fernández-Ruiz, A., Kozák, G., Kincses, Z. T., Iványi, B., Buzsáki, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02928-3 · Cited by 735
Kuo, H.-I., Bikson, M., Datta, A., Minhas, P., Paulus, W., Kuo, M.-F., & Nitsche, M. A. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.09.010 · Cited by 695
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Applications of transcranial direct current stimulation for understanding brain function
Filmer, H. L., Dux, P. E., & Mattingley, J. B. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2014.08.003 · Cited by 519
Origins of specificity during tDCS: anatomical, activity-selective, and input-bias mechanisms
Bikson, M., name, A., & Rahman, A. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00688 · Cited by 410
The electric field in the cortex during transcranial current stimulation
Miranda, P. C., Mekonnen, A., Salvador, R., & Ruffini, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.034 · Cited by 334
Self-citationOn the importance of electrode parameters for shaping electric field patterns generated by tDCS
Saturnino, G. B., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.067 · Cited by 263
Electromechanical cardioplasty using a wrapped elasto-conductive epicardial mesh
Park, J., Choi, S., Janardhan, A. H., Lee, S.-Y., Raut, S., Soares, J., Shin, K., Yang, S., Lee, C., Kang, K.-W., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad8568 · Cited by 253
Kessler, S. K., Minhas, P., Woods, A. J., Rosen, A., Gorman, C., & Bikson, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076112 · Cited by 208
“These findings are consistent with studies exploring the relationships between electrode area, inter-electrode distance, and the distribution of current density in tDCS [12,30].”
Nitsche, M. A., Müller‐Dahlhaus, F., Paulus, W., & Ziemann, U. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.232975 · Cited by 200
“Since the impact of DCS on membrane polarization depends on the orientation of a given neuron relative to the induced electrical field, the effects are not, however, absolutely homogeneous (Faria et al. 2011).”
BackgroundTranscranial Current Brain Stimulation (tCS): Models and Technologies
Ruffini, G., Wendling, F., Merlet, I., Molaee-Ardekani, B., Mekonnen, A., Salvador, R., Soria-Frisch, A., Grau, C., Dunne, S., & Miranda, P. C. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2200046 · Cited by 197
“the optimal electrode placement relative to the target area [46].”
BackgroundSelf-citationBiophysics of Temporal Interference Stimulation
Mirzakhalili, E., Barra, B., Capogrosso, M., & Lempka, S. F. (2020) · Cell Systems · doi:10.1016/j.cels.2020.10.004 · Cited by 193
“The electric potentials generated by electric currents delivered outside the skin rapidly decay with distance from the sources (Faria et al., 2011; Plonsey and Barr, 2007; Rush and Driscoll, 1968).”
BackgroundHo, K.-A., Taylor, J. L., Chew, T., Gálvez, V., Alonzo, A., Bai, S., Dokos, S., & Loo, C. K. (2016) · Brain Stimulation · doi:10.1016/j.brs.2015.08.003 · Cited by 168
“This is thought to be due to the magnitude of current density within the brain falling more rapidly with distance with the smaller electrodes compared to larger electrodes [23].”
BackgroundResultSalehinejad, M. A., Nejati, V., Mosayebi-Samani, M., Mohammadi, A., Wischnewski, M., Kuo, M.-F., Avenanti, A., Vicario, C. M., & Nitsche, M. A. (2020) · Neuroscience Bulletin · doi:10.1007/s12264-020-00501-x · Cited by 118
Nilsson, J., Lebedev, A. V., Rydström, A., & Lövdén, M. (2017) · Psychological Science · doi:10.1177/0956797617698139 · Cited by 118
Hill, A. T., Rogasch, N. C., Fitzgerald, P. B., & Hoy, K. E. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.001 · Cited by 105
“However, computational modelling studies (Datta et al., 2009; Faria et al., 2011; Laakso et al., 2016; Saturnino et al., 2015) indicate relatively diffuse current flow within the brain during stimulation with conventional BP-tDCS montages, thus limiting the accuracy with which the electrical…”
Suh, H. S., Lee, W. H., & Kim, T.-S. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/6961 · Cited by 84
Pripfl, J., & Lamm, C. (2015) · Neuroscience Research · doi:10.1016/j.neures.2014.09.007 · Cited by 45
“Although this has never been shown for areas other than he motor-cortex, and the exact distribution of the current flow hrough the brain is unknown (Datta et al., 2009; Dmochowski et al., 011; Faria et al., 2011), it seems plausible that the much smaller lectrode in our study exerts its influence on a smaller area of…”
Metadata
- Authors
- Faria, P., Hallett, M., & Miranda, P. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-11-15
- Volume
- 8
- Issue
- 6
- Pages
- 066017
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2049012183
- Cited by
- 243
- References
- 45
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.