A finite element analysis of the effect of electrode area and inter-electrode distance on the spatial distribution of the current density in tDCS
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
We investigated the effect of electrode area and inter-electrode distance on the spatial distribution of the current density in transcranial direct current stimulation (tDCS). For this purpose, we used the finite element method to compute the distribution of the current density in a four-layered spherical head model using various electrode montages, corresponding to a range of electrode sizes and inter-electrode distances. We found that smaller electrodes required slightly less current to achieve a constant value of the current density at a reference point on the brain surface located directly under the electrode center. Under these conditions, smaller electrodes also produced a more focal current density distribution in the brain, i.e. the magnitude of the current density fell more rapidly with distance from the reference point. The combination of two electrodes with different areas produced an asymmetric current distribution that could lead to more effective and localized neural modulation under the smaller electrode than under the larger one. Focality improved rapidly with decreasing electrode size when the larger electrode sizes were considered but the improvement was less marked for the smaller electrode sizes. Also, focality was not affected significantly by inter-electrode distance unless two large electrodes were placed close together. Increasing the inter-electrode distance resulted in decreased shunting of the current through the scalp and the cerebrospinal fluid, and decreasing electrode area resulted in increased current density on the scalp under the edges of the electrode. Our calculations suggest that when working with conventional electrodes (25-35 cm(2)), one of the electrodes should be placed just 'behind' the target relative to the other electrode, for maximum current density on the target. Also electrodes with areas in the range 3.5-12 cm(2) may provide a better compromise between focality and current density in the scalp than the traditional electrodes. Finally, the use of multiple small return electrodes may be more efficient than the use of a single large return electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656 · cited 6×
“In the traditional electrode montage E1 is placed over the hand representation in the left primary motor cortex and E2 above the contralateral eyebrow (see, for instance (Nitsche and Paulus, 2000; Nitsche and Paulus, 2001)).”
BackgroundInfluentialTranscranial direct current stimulation: State of the art 2008
Nitsche, M. A., Cohen, L. G., Wassermann, E. M., Priori, A., Lang, N., Antal, A., Paulus, W., Hummel, F., Boggio, P. S., Fregni, F., et al. (2008) · Brain Stimulation · doi:10.1016/j.brs.2008.06.004 · Cited by 3,057 · cited 2×
“By 2008, more than 2000 subjects had been stimulated worldwide using a current of 1 mA without clinically relevant side effects (Nitsche et al 2008).”
BackgroundSustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Gandiga, P. C., Hummel, F. C., & Cohen, L. G. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.12.003 · Cited by 1,474
Datta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290 · cited 3×
“…been published, either with point-like electrodes (Ferdjallah et al 1996) or with more realistic electrode and/or head models (Stecker 2005, Miranda et al 2006, Wagner et al 2007, Datta et al 2008, Datta et al 2009, Faria et al 2009, Miranda et al 2009, Sadleir et al 2010, Parazzini et al 2011).”
Safety aspects of transcranial direct current stimulation concerning healthy subjects and patients
Poreisz, C., Boros, K., Antal, A., & Paulus, W. (2007) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2007.01.004 · Cited by 1,099 · cited 1×
“To date, all studies concerning the safety of tDCS indicate that the application of a current of 1 mA for periods up to 20 min using electrodes whose area is 25 or 35 cm2 has no significant adverse effects (Nitsche et al 2003, Iyer et al 2005, Poreisz et al 2007).”
BackgroundModeling the current distribution during transcranial direct current stimulation
Miranda, P. C., Lomarev, M., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.009 · Cited by 762
Self-citationBikson, M., Inoue, M., Akiyama, H., Deans, J. K., Fox, J. E., Miyakawa, H., & Jefferys, J. G. R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.055772 · Cited by 743 · cited 3×
“The choice of a current density “threshold” for calculating measures of focality is somewhat arbitrary in tDCS since the effect of stimulation on the neuronal membrane varies linearly with stimulation intensity (Bikson et al., 2004).”
BackgroundMethodShaping the Effects of Transcranial Direct Current Stimulation of the Human Motor Cortex
Nitsche, M. A., Doemkes, S., Karaköse, T., Antal, A., Liebetanz, D., Lang, N., Tergau, F., & Paulus, W. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01312.2006 · Cited by 738
Radman, T., Ramos, R. L., Brumberg, J. C., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.007 · Cited by 702 · cited 1×
“The implicit assumption underlying these modeling studies is that the effect of tDCS on neurons is linearly proportional to the magnitude of the current density (or electric field) in the brain, as suggested by in vitro experiments (Bikson et al 2004, Radman et al 2009).”
MethodSafety criteria for transcranial direct current stimulation (tDCS) in humans
Nitsche, M. A., Liebetanz, D., Lang, N., Antal, A., Tergau, F., & Paulus, W. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00235-9 · Cited by 697
Safety and cognitive effect of frontal DC brain polarization in healthy individuals
Iyer, M. B., Mattu, U., Grafman, J., Lomarev, M., Sato, S., & Wassermann, E. M. (2005) · Neurology · doi:10.1212/01.wnl.0000152986.07469.e9 · Cited by 686
Transcranial direct current stimulation of the unaffected hemisphere in stroke patients
Fregni, F., Boggio, P. S., Mansur, C. G., Wagner, T., Ferreira, M. J. L., Lima, M. C., Rigonatti, S. P., Marcolin, M. A., Freedman, S. D., Nitsche, M. A., et al. (2005) · NeuroReport · doi:10.1097/01.wnr.0000177010.44602.5e · Cited by 600 · cited 1×
“In addition, tDCS has shown promising results as a potential therapy for several pathologies such as stroke (Fregni et al., 2005), depression (Ferrucci et al.”
BackgroundOptimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 590
State-dependency in brain stimulation studies of perception and cognition
Silvanto, J., Muggleton, N., & Walsh, V. (2008) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2008.09.004 · Cited by 572 · cited 1×
“However, many other factors also contribute to the final output of stimulation, ranging from the relative orientation of the neurons and the applied electric field (Rushton 1927) to brain state dependence (Silvanto et al 2008).”
BackgroundTranscranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567 · cited 2×
“…been published, either with point-like electrodes (Ferdjallah et al 1996) or with more realistic electrode and/or head models (Stecker 2005, Miranda et al 2006, Wagner et al 2007, Datta et al 2008, Datta et al 2009, Faria et al 2009, Miranda et al 2009, Sadleir et al 2010, Parazzini et al 2011).”
MethodCurrent Distribution in the Brain From Surface Electrodes
RUSH, S., & DRISCOLL, D. A. (1968) · Anesthesia & Analgesia · doi:10.1213/00000539-196811000-00016 · Cited by 521 · cited 3×
“The spherical head model proposed by Rush and Driscoll (1968) was adapted in order to implement a four-layer spherical head model consisting of four homogeneous and isotropic concentric spheres.”
BackgroundMethodResultInfluentialTreatment of major depression with transcranial direct current stimulation
Fregni, F., Boggio, P. S., Nitsche, M. A., Marcolin, M. A., Rigonatti, S. P., & Pascual‐Leone, A. (2006) · Bipolar Disorders · doi:10.1111/j.1399-5618.2006.00291.x · Cited by 495
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
EEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448 · cited 4×
“The use of conductivity values taken from the EEG literature was deemed appropriate since tDCS and EEG are linked by the reciprocity theorem (Rush and Driscoll 1969).”
BackgroundMethodInfluentialNoninvasive cortical stimulation with transcranial direct current stimulation in Parkinson's disease
Fregni, F., Boggio, P. S., Santos, M. C., Lima, M., Vieira, A. L., Rigonatti, S. P., Silva, M. T. A., Barbosa, E. R., Nitsche, M. A., & Pascual‐Leone, A. (2006) · Movement Disorders · doi:10.1002/mds.21012 · Cited by 433
Boggio, P. S., Khoury, L. P., Martins, D. C. S., Martins, O. E. M. S., de Macedo, E. C., & Fregni, F. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.141853 · Cited by 370
Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis
Datta, A., Elwassif, M., Battaglia, F., & Bikson, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/007 · Cited by 320 · cited 6×
“It also affects the fraction of the injected current that reaches the brain as well as the distribution of the radial and tangential components of the current density (Datta et al 2008).”
BackgroundMethodInfluentialA theoretical calculation of the electric field induced in the cortex during magnetic stimulation
Roth, B. J., Saypol, J. M., Hallett, M., & Cohen, L. G. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90103-5 · Cited by 307
Self-citationA Controlled Clinical Trial of Cathodal DC Polarization in Patients with Refractory Epilepsy
Fregni, F., Thome‐Souza, S., Nitsche, M. A., Freedman, S. D., Valente, K. D., & Pascual‐Leone, A. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00426.x · Cited by 295 · cited 1×
“In addition, tDCS has shown promising results as a potential therapy for several pathologies such as stroke (Fregni et al 2005), depression (Ferrucci et al 2009, Fregni et al 2006a), Parkinson’s disease (Fregni et al 2006b), Alzheimer’s disease (Boggio et al 2009) and epilepsy (Fregni et al 2006c).”
BackgroundMinhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.007 · Cited by 267
Transcranial direct current stimulation (tDCS) in a realistic head model
Sadleir, R. J., Vannorsdall, T. D., Schretlen, D. J., & Gordon, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.052 · Cited by 232
Transcranial direct current stimulation in severe, drug-resistant major depression
Ferrucci, R., Bortolomasi, M., Vergari, M., Tadini, L., Salvoro, B., Giacopuzzi, M., Barbieri, S., & Priori, A. (2009) · Journal of Affective Disorders · doi:10.1016/j.jad.2009.02.015 · Cited by 228 · cited 2×
“In addition, tDCS has shown promising results as a potential therapy for several pathologies such as stroke (Fregni et al 2005), depression (Ferrucci et al 2009, Fregni et al 2006a), Parkinson’s disease (Fregni et al 2006b), Alzheimer’s disease (Boggio et al 2009) and epilepsy (Fregni et al 2006c).”
BackgroundGoncalves, S. I., de Munck, J. C., Verbunt, J. P. A., Bijma, F., Heethaar, R. M., & Lopes da Silva, F. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812164 · Cited by 219 · cited 1×
“…rbrain = 7.9 cm, rCSF = 8.1 cm (Manola et al 2005, Stok 1987), rskull = 8.6 cm and rscalp = 9.2 cm (Nunez and Srinivasan 2006); σ brain = σ scalp 0.332 S m−1 (Goncalves et al 2003), σ CSF = 1.79 S m−1 (Baumann et al 1997), σ skull = 0.0083 S m−1 (Goncalves et al 2003, Nunez and Srinivasan 2006).”
InfluentialChapter 26 Transcranial direct current stimulation (tDCS)
Paulus, W. (2003) · Supplements to Clinical Neurophysiology · doi:10.1016/s1567-424x(09)70229-6 · Cited by 191
Rushton, W. A. H. (1927) · The Journal of Physiology · doi:10.1113/jphysiol.1927.sp002409 · Cited by 171
Retinal origin of phosphenes to transcranial alternating current stimulation
Schutter, D. J. L. G., & Hortensius, R. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.038 · Cited by 167
Miranda, P. C., Faria, P., & Hallett, M. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.03.023 · Cited by 164
Self-citationStimulation of a myelinated nerve axon by electromagnetic induction
Basser, P. J., & Roth, B. J. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446708 · Cited by 162
Rossini, P. M., Marciani, M. G., Caramia, M. D., Roma, V., & Zarola, F. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(85)91094-6 · Cited by 160 · cited 1×
“This comes close to achieving ‘unifocal’ stimulation, traditionally implemented with transcranial electrical stimulation using one electrode over the target region and several connected electrodes of the same size distributed around the perimeter of the head (Rossini et al 1985).”
BackgroundThe influence of model parameters on EEG/MEG single dipole source estimation
Stok, C. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326090 · Cited by 146
Method to reduce blur distortion from EEG's using a realistic head model
Le, J., & Gevins, A. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237671 · Cited by 145 · cited 2×
“This blurring effect of the skull is well documented in the EEG literature (see, e.g., Le and Gevins (1993)).”
Parazzini, M., Fiocchi, S., Rossi, E. G., Paglialonga, A., & Ravazzani, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2116019 · Cited by 142 · cited 2×
“…been published, either with point-like electrodes (Ferdjallah et al 1996) or with more realistic electrode and/or head models (Stecker 2005, Miranda et al 2006, Wagner et al 2007, Datta et al 2008, Datta et al 2009, Faria et al 2009, Miranda et al 2009, Sadleir et al 2010, Parazzini et al 2011).”
MethodManola, L., Roelofsen, B. H., Holsheimer, J., Marani, E., & Geelen, J. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345810 · Cited by 132 · cited 1×
“The values for the radius and electrical conductivity of the brain, CSF, skull and scalp were the following: rbrain = 7.9 cm, rCSF = 8.1 cm (Manola et al 2005, Stok 1987), rskull = 8.6 cm and rscalp = 9.2 cm (Nunez and Srinivasan 2006); σ brain = σ scalp 0.332 S m−1 (Goncalves et al 2003), σ CSF =…”
BackgroundInfluentialPaulus, W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.029 · Cited by 83 · cited 2×
“Also, our model does not include the various openings that exist in the skull and which may affect the current density in the nearby cortex (Paulus 2010, Schutter and Hortensius 2010).”
BackgroundFaria, P., Leal, A., & Miranda, P. C. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5334121 · Cited by 42 · cited 4×
“…been published, either with point-like electrodes (Ferdjallah et al 1996) or with more realistic electrode and/or head models (Stecker 2005, Miranda et al 2006, Wagner et al 2007, Datta et al 2008, Datta et al 2009, Faria et al 2009, Miranda et al 2009, Sadleir et al 2010, Parazzini et al 2011).”
MethodSelf-citationTranscranial electric stimulation of motor pathways: a theoretical analysis
Stecker, M. M. (2004) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2003.12.005 · Cited by 36
Toroidal coil models for transcutaneous magnetic simulation of nerves
Carbunaru, R., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.915709 · Cited by 21
Cited by
Evidence-based guidelines on the therapeutic use of transcranial direct current stimulation (tDCS)
Lefaucheur, J.-P., Antal, A., Ayache, S. S., Benninger, D. H., Brunelin, J., Cogiamanian, F., Cotelli, M., De Ridder, D., Ferrucci, R., Langguth, B., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.10.087 · Cited by 1,826
A technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Self-citationAntal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationDirect effects of transcranial electric stimulation on brain circuits in rats and humans
Vöröslakos, M., Takeuchi, Y., Brinyiczki, K., Zombori, T., Oliva, A., Fernández-Ruiz, A., Kozák, G., Kincses, Z. T., Iványi, B., Buzsáki, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02928-3 · Cited by 735
Kuo, H.-I., Bikson, M., Datta, A., Minhas, P., Paulus, W., Kuo, M.-F., & Nitsche, M. A. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.09.010 · Cited by 695
Metadata
- Authors
- Faria, P., Hallett, M., & Miranda, P. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-11-15
- Volume
- 8
- Issue
- 6
- Pages
- 066017
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2049012183
- Cited by
- 243
- References
- 45
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.