On the use of Tedlar® bags for breath-gas sampling and analysis
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
The storage capability of Tedlar® bags for gaseous compounds was assessed using on-line proton-transfer-reaction mass spectrometry (PTR-MS). Sample bags were filled with a mixture of volatile organic compounds (VOCs) at known quantities in the ppbv range. The test gas included alcohol, nitrile, aldehyde, ketone, terpene and aromatic compounds. PTR-MS enabled frequent bag-direct measurements of compound abundances over a 70 h storage period. Concentrations of all compounds decreased with bag storage time, with compound-specific decay rates. The most rapid decline in concentration levels was seen for water vapour in the bag, i.e. sample humidity. Such a decrease is particularly relevant for breath-gas samples, where water vapour content is high. Compound losses were attributed to a combination of adsorption to and diffusion through the bag walls. Storage property observations suggest that sample analyses made within 10 h of sampling offer adequate sample authenticity replication. Based on observations, an appropriate bag-cleaning procedure was established and assessed. Results indicated that acceptable bag cleanliness for breath-gas sampling is achievable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluated Gas Phase Basicities and Proton Affinities of Molecules: An Update
Hunter, E. P. L., & Lias, S. G. (1998) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.556018 · Cited by 2,702
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615 · cited 3×
“Acetonitrile is present in relatively high concentrations in the breath-gas of smokers, with levels dependent on the time elapsed since smoking the last cigarette and on quantity/frequency of smoking (e.g. Jordan et al (1995), Lindinger et al (1998) and Kushch et al (2008)).”
BackgroundMethodSelf-citationDiagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096 · cited 1×
“Much research is presently being undertaken to advance this area of medical expertise, such as identifying diseaserelated marker compounds or establishing suitable sampling and analysis methods (e.g. reviewed in Miekisch et al (2004), Cao and Duan (2006) and Risby and Solga (2006)).”
de Gouw, J., & Warneke, C. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20119 · Cited by 1,055 · cited 2×
“For example, a recent determination and discussion of a PTR-MS instrument’s LOD for benzene, based on three standard deviations above the noise, yielded 35 pptv (de Gouw and Warneke 2007).”
BackgroundMethodVolatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918 · cited 3×
“Both acetaldehyde and hexanal have been identified in human breath; acetaldehyde as a metabolic byproduct of alcohol consumption (Freund and O’Hollaren 1965, Turner et al 2006b) and hexanal in the breath-gas of lung cancer suffers (Phillips et al 1999).”
BackgroundMethodSelected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801 · cited 1×
“Breathgas analysis may be accomplished either by direct, on-line sampling and analysis (Riter et al 2002, Harrison et al 2003, Smith and Španel 2005, Herbig et al 2008) or by using a sampling container/trap for subsequent off-line analysis (Phillips et al 1999, Steeghs et al 2007a, Wehinger et al…”
MethodProton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727 · cited 1×
“The technique has been described extensively elsewhere (Hansel et al 1995, Lindinger et al 1998, de Gouw et al 2003); therefore, only a brief overview of operation follows.”
MethodSelf-citationFinlayson-Pitts, B. J., Wingen, L. M., Sumner, A. L., Syomin, D., & Ramazan, K. A. (2003) · Physical Chemistry Chemical Physics · doi:10.1039/b208564j · Cited by 691
Deng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590 · cited 3×
“Acetone is the predominant VOC present in human breath in the low ppmv range (Lindinger et al 1998, Turner et al 2006c) and is particularly prevalent in the breathgas of diabetics (e.g. Deng et al (2004) and references therein).”
BackgroundInfluentialAn electronic nose in the discrimination of patients with asthma and controls
Dragonieri, S., Schot, R., Mertens, B. J. A., Le Cessie, S., Gauw, S. A., Spanevello, A., Resta, O., Willard, N. P., Vink, T. J., Rabe, K. F., et al. (2007) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.05.043 · Cited by 451
Breath Analysis: Potential for Clinical Diagnosis and Exposure Assessment
Cao, W., & Duan, Y. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.063545 · Cited by 391 · cited 1×
“Much research is presently being undertaken to advance this area of medical expertise, such as identifying diseaserelated marker compounds or establishing suitable sampling and analysis methods (e.g. reviewed in Miekisch et al (2004), Cao and Duan (2006) and Risby and Solga (2006)).”
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Current status of clinical breath analysis
Risby, T. H., & Solga, S. F. (2006) · Applied Physics B · doi:10.1007/s00340-006-2280-4 · Cited by 363
de Gouw, J., Warneke, C., Karl, T., Eerdekens, G., van der Veen, C., & Fall, R. (2003) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00926-0 · Cited by 345
Warneke, C., de Gouw, J. A., Kuster, W. C., Goldan, P. D., & Fall, R. (2003) · Environmental Science & Technology · doi:10.1021/es026266i · Cited by 288 · cited 1×
“This is supported in the literature by investigations of adsorption effects for toluene on Viton and Teflon, which were found to be minimal (Warneke et al 2003).”
BackgroundLung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas
Wehinger, A., Schmid, A., Mechtcheriakov, S., Ledochowski, M., Grabmer, C., Gastl, G. A., & Amann, A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.05.012 · Cited by 280 · cited 1×
“…analysis may be accomplished either by direct, on-line sampling and analysis (Riter et al 2002, Harrison et al 2003, Smith and Španel 2005, Herbig et al 2008) or by using a sampling container/trap for subsequent off-line analysis (Phillips et al 1999, Steeghs et al 2007a, Wehinger et al 2007).”
MethodTropospheric cycle of nitrous acid
Harrison, R. M., Peak, J. D., & Collins, G. M. (1996) · Journal of Geophysical Research Atmospheres · doi:10.1029/96jd00341 · Cited by 275
Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling
Karl, T., Prazeller, P., Mayr, D., Jordan, A., Rieder, J., Fall, R., & Lindinger, W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.762 · Cited by 264 · cited 2×
“Isoprene is a highly abundant breathgas constituent resulting from metabolic processes, such as cholesterol synthesis (Hyspler et al 2000, Karl et al 2001).”
BackgroundMayr, D., Margesin, R., Klingsbichel, E., Hartungen, E., Jenewein, D., Schinner, F., & Märk, T. D. (2003) · Applied and Environmental Microbiology · doi:10.1128/aem.69.8.4697-4705.2003 · Cited by 162 · cited 1×
“…already a well-established analytical tool in other scientific areas, particularly in environmental research (see e.g. Wisthaler et al (2002), Ammann et al (2004) and de Gouw and Warneke (2007)) and in food chemistry research (e.g. Gasperi et al (2000), Mayr et al (2003) and Spitaler et al (2007)).”
MethodHarrison, G., Critchley, A. D. J., Mayhew, C. A., & Thompson, J. M. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg271 · Cited by 161
Jordan, A., Hansel, A., Holzinger, R., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04236-e · Cited by 158 · cited 2×
“Acetonitrile is present in relatively high concentrations in the breath-gas of smokers, with levels dependent on the time elapsed since smoking the last cigarette and on quantity/frequency of smoking (e.g. Jordan et al (1995), Lindinger et al (1998) and Kushch et al (2008)).”
BackgroundSelf-citationTurner, C., Španěl, P., & Smith, D. C. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/007 · Cited by 150
Bias of Tedlar Bags in the Measurement of Agricultural Odorants
Trabue, S. L., Anhalt, J. C., & Zahn, J. A. (2006) · Journal of Environmental Quality · doi:10.2134/jeq2005.0370 · Cited by 144
Inomata, S., Tanimoto, H., Kameyama, S., Tsunogai, U., Irie, H., Kanaya, Y., & Wang, Z. (2008) · Atmospheric chemistry and physics · doi:10.5194/acp-8-273-2008 · Cited by 144
Turner, C., Španěl, P., & Smith, D. C. (2005) · Physiological Measurement · doi:10.1088/0967-3334/27/1/002 · Cited by 140
Kushch, I., Schwarz, K., Schwentner, L., Baumann, B., Dzien, A., Schmid, A., Unterkofler, K., Gastl, G., Španěl, P., Smith, D., et al. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/2/026002 · Cited by 137
Exhaled Nitric Oxide Measurements in a Population Sample of Young Adults
SALOME, C. M., ROBERTS, A. M., Brown, N. J., Dermand, J. C., Marks, G. B., & Woolcock, A. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9802108 · Cited by 131
The suitability of Tedlar bags for breath sampling in medical diagnostic research
Steeghs, M. M. L., Cristescu, S. M., & Harren, F. J. M. (2006) · Physiological Measurement · doi:10.1088/0967-3334/28/1/007 · Cited by 126
Taucher, J., Hansel, A., Jordan, A., Fall, R., Futrell, J. H., & Lindinger, W. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199707)11:11<1230::aid-rcm3>3.0.co;2-z · Cited by 120 · cited 1×
“…the most popular containers 1752-7155/08/046001+19$30.00 1 © 2008 IOP Publishing Ltd Printed in the UK generally implemented for breath-gas sampling (e.g. Sannolo et al (1983), Taucher et al (1997), Salome et al (1999), Deng et al (2004), Dragonieri et al (2007) and Steeghs et al (2007a)).”
BackgroundInfluentialSelf-citationOrganic trace gas measurements by PTR‐MS during INDOEX 1999
Wisthaler, A., Hansel, A., Dickerson, R. R., & Crutzen, P. J. (2002) · Journal of Geophysical Research Atmospheres · doi:10.1029/2001jd000576 · Cited by 108 · cited 1×
“…of breath-gas analysis, it is already a well-established analytical tool in other scientific areas, particularly in environmental research (see e.g. Wisthaler et al (2002), Ammann et al (2004) and de Gouw and Warneke (2007)) and in food chemistry research (e.g. Gasperi et al (2000), Mayr et al…”
MethodSelf-citationNielsen, A. T., & Jonsson, S. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00556-3 · Cited by 107
Steinbacher, M., Dommen, J., Ammann, C., Spirig, C., Neftel, A., & Prévôt, A. S. H. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.07.015 · Cited by 107 · cited 1×
“Furthermore, all PTR-MS data were corrected for m/z-dependent transmission effects following a separate transmission determination measurement, carried out in a similar manner to that described by Steinbacher et al (2004).”
MethodHyšpler, R., Crhová, Š., Gasparič, J., Zadák, Z., Čı́žková, M., & Balasová, V. (2000) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00423-5 · Cited by 105 · cited 1×
“Isoprene is a highly abundant breathgas constituent resulting from metabolic processes, such as cholesterol synthesis (Hyspler et al 2000, Karl et al 2001).”
BackgroundBuffered end-tidal (BET) sampling—a novel method for real-time breath-gas analysis
Herbig, J., Titzmann, T., Beauchamp, J. D., Kohl, I., & Hansel, A. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037008 · Cited by 97 · cited 1×
“Breathgas analysis may be accomplished either by direct, on-line sampling and analysis (Riter et al 2002, Harrison et al 2003, Smith and Španel 2005, Herbig et al 2008) or by using a sampling container/trap for subsequent off-line analysis (Phillips et al 1999, Steeghs et al 2007a, Wehinger et al…”
MethodSelf-citationOdor Concentration Decay and Stability in Gas Sampling Bags
van Harreveld, A. P. (2003) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2003.10466121 · Cited by 70 · cited 1×
“This recommendation is reiterated by van Harreveld (2003), who investigated Nalophan bags and found that samples remained relatively stable between 4 and 12 h after sampling.”
BackgroundAcetaldehyde concentrations in alveolar air following a standard dose of ethanol in man
Freund, G., & O’Hollaren, P. (1965) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)39608-5 · Cited by 67
Gasperi, F., Gallerani, G., Boschetti, A., Franco Biasioli, A., Monetti, A., Boscaini, E., Jordan, A., Lindinger, W., & Iannotta, S. (2001) · Journal of the Science of Food and Agriculture · Cited by 66 · cited 1×
“…already a well-established analytical tool in other scientific areas, particularly in environmental research (see e.g. Wisthaler et al (2002), Ammann et al (2004) and de Gouw and Warneke (2007)) and in food chemistry research (e.g. Gasperi et al (2000), Mayr et al (2003) and Spitaler et al (2007)).”
MethodAn off-line breath sampling and analysis method suitable for large screening studies
Steeghs, M. M. L., Cristescu, S. M., Munnik, P., Zanen, P., & Harren, F. J. M. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/5/005 · Cited by 54
Stability of Trace-level VOLatile Organic Compounds Stored in Canisters and Tedlar Bags
Hsieh, C., Horng, S.-H., & Liao, P.-N. (2003) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2003.06.0003 · Cited by 35
Suitability of different plastic materials for head or nose spaces short term storage
Pet’ka, J., Étiévant, P. X., & Callement, G. (2000) · Analusis · doi:10.1051/analusis:2000123 · Cited by 31
Cited by
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Breath gas aldehydes as biomarkers of lung cancer
Fuchs, P., Loeseken, C., Schubert, J. K., & Miekisch, W. (2010) · International Journal of Cancer · doi:10.1002/ijc.24970 · Cited by 513
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Metadata
- Authors
- Beauchamp, J., Herbig, J., Gutmann, R., & Hansel, A.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2008-07-24
- Volume
- 2
- Issue
- 4
- Pages
- 046001
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W1965495508
- Cited by
- 236
- References
- 40
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.