On the use of Tedlar® bags for breath-gas sampling and analysis
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
The storage capability of Tedlar® bags for gaseous compounds was assessed using on-line proton-transfer-reaction mass spectrometry (PTR-MS). Sample bags were filled with a mixture of volatile organic compounds (VOCs) at known quantities in the ppbv range. The test gas included alcohol, nitrile, aldehyde, ketone, terpene and aromatic compounds. PTR-MS enabled frequent bag-direct measurements of compound abundances over a 70 h storage period. Concentrations of all compounds decreased with bag storage time, with compound-specific decay rates. The most rapid decline in concentration levels was seen for water vapour in the bag, i.e. sample humidity. Such a decrease is particularly relevant for breath-gas samples, where water vapour content is high. Compound losses were attributed to a combination of adsorption to and diffusion through the bag walls. Storage property observations suggest that sample analyses made within 10 h of sampling offer adequate sample authenticity replication. Based on observations, an appropriate bag-cleaning procedure was established and assessed. Results indicated that acceptable bag cleanliness for breath-gas sampling is achievable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluated Gas Phase Basicities and Proton Affinities of Molecules: An Update
Hunter, E. P. L., & Lias, S. G. (1998) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.556018 · Cited by 2,702
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615 · cited 3×
“Acetonitrile is present in relatively high concentrations in the breath-gas of smokers, with levels dependent on the time elapsed since smoking the last cigarette and on quantity/frequency of smoking (e.g. Jordan et al (1995), Lindinger et al (1998) and Kushch et al (2008)).”
BackgroundMethodSelf-citationDiagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096 · cited 1×
“Much research is presently being undertaken to advance this area of medical expertise, such as identifying diseaserelated marker compounds or establishing suitable sampling and analysis methods (e.g. reviewed in Miekisch et al (2004), Cao and Duan (2006) and Risby and Solga (2006)).”
de Gouw, J., & Warneke, C. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20119 · Cited by 1,055 · cited 2×
“For example, a recent determination and discussion of a PTR-MS instrument’s LOD for benzene, based on three standard deviations above the noise, yielded 35 pptv (de Gouw and Warneke 2007).”
BackgroundMethodVolatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918 · cited 3×
“Both acetaldehyde and hexanal have been identified in human breath; acetaldehyde as a metabolic byproduct of alcohol consumption (Freund and O’Hollaren 1965, Turner et al 2006b) and hexanal in the breath-gas of lung cancer suffers (Phillips et al 1999).”
BackgroundMethodSelected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801 · cited 1×
“Breathgas analysis may be accomplished either by direct, on-line sampling and analysis (Riter et al 2002, Harrison et al 2003, Smith and Španel 2005, Herbig et al 2008) or by using a sampling container/trap for subsequent off-line analysis (Phillips et al 1999, Steeghs et al 2007a, Wehinger et al…”
MethodProton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727 · cited 1×
“The technique has been described extensively elsewhere (Hansel et al 1995, Lindinger et al 1998, de Gouw et al 2003); therefore, only a brief overview of operation follows.”
MethodSelf-citationFinlayson-Pitts, B. J., Wingen, L. M., Sumner, A. L., Syomin, D., & Ramazan, K. A. (2003) · Physical Chemistry Chemical Physics · doi:10.1039/b208564j · Cited by 691
Deng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590 · cited 3×
“Acetone is the predominant VOC present in human breath in the low ppmv range (Lindinger et al 1998, Turner et al 2006c) and is particularly prevalent in the breathgas of diabetics (e.g. Deng et al (2004) and references therein).”
BackgroundInfluentialAn electronic nose in the discrimination of patients with asthma and controls
Dragonieri, S., Schot, R., Mertens, B. J. A., Le Cessie, S., Gauw, S. A., Spanevello, A., Resta, O., Willard, N. P., Vink, T. J., Rabe, K. F., et al. (2007) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.05.043 · Cited by 451
Cited by
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Breath gas aldehydes as biomarkers of lung cancer
Fuchs, P., Loeseken, C., Schubert, J. K., & Miekisch, W. (2010) · International Journal of Cancer · doi:10.1002/ijc.24970 · Cited by 513
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Exhaled breath analysis: a review of ‘breath-taking’ methods for off-line analysis
Lawal, O., Ahmed, W. M., Nijsen, T. M. E., Goodacre, R., & Fowler, S. J. (2017) · Metabolomics · doi:10.1007/s11306-017-1241-8 · Cited by 288
Hunt, K. E., Moore, M. J., Rolland, R. M., Kellar, N. M., Hall, A. J., Kershaw, J., Raverty, S. A., Davis, C. E., Yeates, L. C., Fauquier, D. A., et al. (2013) · Conservation Physiology · doi:10.1093/conphys/cot006 · Cited by 231
“In humans, inert Tedlar® bags are often used for collection of whole breath (Groves and Zellers, 1996; Steeghs et al., 2007; Beauchamp et al., 2008), while non-volatile components are often collected via cooling of exhaled breath to produce ‘exhaled breath condensate’ (EBC; Soyer et al.”
BackgroundNanomaterial-based gas sensors used for breath diagnosis
Zhou, X., Xue, Z., Chen, X., Huang, C., Bai, W., Lu, Z., & Wang, T. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02518a · Cited by 227
On-line breath analysis with PTR-TOF
Herbig, J., Müller, M., Schallhart, S., Titzmann, T., Graus, M., & Hansel, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027004 · Cited by 205
Self-citationDetection of cancer through exhaled breath: a systematic review
Krilaviciute, A., Heiss, J. A., Leja, M., Kupcinskas, J., Haick, H., & Brenner, H. (2015) · Oncotarget · doi:10.18632/oncotarget.5938 · Cited by 188
Jia, Z., Patra, A., Kutty, V. K., & Venkatesan, T. (2019) · Metabolites · doi:10.3390/metabo9030052 · Cited by 187
“For example, the widely accepted Tedlar bags for breath collection are made of polyvinyl fluoride and are known to emit many VOCs from the bag material, which, therefore, poses a threat of contamination [77,78].”
BackgroundMass spectrometry for real-time quantitative breath analysis
Smith, D., Španěl, P., Herbig, J., & Beauchamp, J. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027101 · Cited by 174
Self-citationDetermining concentration patterns of volatile compounds in exhaled breath by PTR-MS
Schwarz, K., Filipiak, W., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027002 · Cited by 158
Breathomics for the clinician: the use of volatile organic compounds in respiratory diseases
Ibrahim, W., Carr, L., Cordell, R., Wilde, M. J., Salman, D., Monks, P. S., Thomas, P., Brightling, C. E., Siddiqui, S., & Greening, N. J. (2021) · Thorax · doi:10.1136/thoraxjnl-2020-215667 · Cited by 115
Peel, A. M., Wilkinson, M., Sinha, A., Loke, Y. K., Fowler, S. J., & Wilson, A. M. (2020) · Respiratory Medicine · doi:10.1016/j.rmed.2020.105984 · Cited by 40
“While VOC losses have been described as within acceptable levels (57, 58) this could nonetheless result in those VOCs present at very low concentrations becoming undetectable; moreover the differential decay rates reported across VOCs could change relative concentrations over time.”
Metadata
- Authors
- Beauchamp, J., Herbig, J., Gutmann, R., & Hansel, A.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2008-07-24
- Volume
- 2
- Issue
- 4
- Pages
- 046001
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W1965495508
- Cited by
- 236
- References
- 40
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.