Modulating mechanical behaviour of 3D-printed cartilage-mimetic PCL scaffolds: influence of molecular weight and pore geometry
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Three-dimensional (3D)-printed poly(ε)-caprolactone (PCL)-based scaffolds are increasingly being explored for cartilage tissue engineering (CTE) applications. However, ensuring that the mechanical properties of these PCL-based constructs are comparable to that of articular cartilage that they are meant to regenerate is an area that has been under-explored. This paper presents the effects of PCL's molecular weight (MW) and scaffold's pore geometric configurations; strand size (SZ), strand spacing (SS), and strand orientation (SO), on mechanical properties of 3D-printed PCL scaffolds. The results illustrate that MW has significant effect on compressive moduli and yield strength of 3D-printed PCL scaffolds. Specifically, PCL with MW of 45 K was a more feasible choice for fabrication of visco-elastic, flexible and load-bearing PCL scaffolds. Furthermore, pore geometric configurations; SZ, SS, and SO, all significantly affect on tensile moduli of scaffolds. However, only SZ and SS have statistically significant effects on compressive moduli and porosity of these scaffolds. That said, inverse linear relationship was observed between porosity and mechanical properties of 3D-printed PCL scaffolds in Pearson's correlation test. Altogether, this study illustrates that modulating MW of PCL and pore geometrical configurations of the scaffolds enabled design and fabrication of PCL scaffolds with mechanical and biomimetic properties that better mimic mechanical behaviour of human articular cartilage. Thus, the modulated PCL scaffold proposed in this study is a framework that offers great potentials for CTE applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033 · cited 1×
“In addition, PCL has good bioresorbability, slower © 2016 IOPPublishing Ltd degradation rate (ranging from months to years), low cost, excellent viscoelastic properties, cellular biocompatibility, and nonimmunogenicity (Woodruff and Hutmacher 2010, Olubamiji et al 2016).”
BackgroundBox-Behnken design: An alternative for the optimization of analytical methods
Ferreira, S. L. C., Bruns, R. E., Ferreira, H. S., Matos, G. D., David, J. M., Brandão, G. C., da Silva, E. G. P., Portugal, L. A., dos Reis, P. S., Souza, A. S., et al. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.011 · Cited by 3,214 · cited 1×
“…fabricated using the MW recommended in experiment I. Design of experiment called Box–Behnken design (BBD); a response-surface-methodologybased experimental design (Ferreira et al 2007, Yue et al 2008, Ma et al 2009), was used to reduce the number of experimental groups required to 13 from 27 (33)…”
MethodThe Basic Science of Articular Cartilage: Structure, Composition, and Function
Sophia Fox, A. J., Bedi, A., & Rodeo, S. A. (2009) · Sports Health: A Multidisciplinary Approach · doi:10.1177/1941738109350438 · Cited by 2,774 · cited 1×
“Compressive integrity of articular cartilage primarily depends on its glycosaminoglycan (GAG) content, while its tensile integrity relies largely on its collagen type II content (Maroudas 1979, Sophia Fox et al 2009).”
BackgroundPrinting three-dimensional tissue analogues with decellularized extracellular matrix bioink
Pati, F., Jang, J., Ha, D.-H., Won Kim, S., Rhie, J.-W., Shim, J.-H., Kim, D.-H., & Cho, D.-W. (2014) · Nature Communications · doi:10.1038/ncomms4935 · Cited by 1,904
Fused deposition modeling of novel scaffold architectures for tissue engineering applications
Zein, I., Hutmacher, D. W., Tan, K. C., & Teoh, S. H. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00232-0 · Cited by 1,874 · cited 4×
“These results support the idea that varying pore geometrical configurations changes mechanical properties of scaffolds (Zein et al 2002, Woodfield et al 2004, Moroni et al 2006, Lebourg et al 2008, Guarino et al 2007).”
BackgroundResultInfluentialBone tissue engineering using polycaprolactone scaffolds fabricated via selective laser sintering
Williams, J. M., Adewunmi, A., Schek, R. M., Flanagan, C. L., Krebsbach, P. H., Feinberg, S. E., Hollister, S. J., & Das, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.057 · Cited by 1,563
Hutmacher, D. W., Schantz, T., Zein, I., Ng, K. W., Teoh, S. H., & Tan, K. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<203::aid-jbm1007>3.0.co;2-7 · Cited by 1,409 · cited 1×
“41.9 (Hutmacher et al 2001) 35.5± 5.8 (Eshraghi and Das 2010) 44.0± 3.2 (Mondrinos et al 2006) 53± 36 (Baker et al 2016) 52± 2–67± 4 (Williams et al 2005) 105± 15 (Lu et al 2014) 59 (Shor et al 2009) 277.06± 27.66 (Doyle et al 2014) 150–200 (Wang et al 2004) 215.4± 6.6 (Lu et al…”
InfluentialBiosynthetic response of cartilage explants to dynamic compression
Sah, R. L. ‐., Kim, Y., Doong, J. H., Grodzinsky, A. J., Plass, A. H. K., & Sandy, J. D. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070502 · Cited by 875 · cited 6×
“Despite the popularity of PCL-based scaffolds for CTE applications in recent times, these studies neither focused nor considered how tailoring mechanical properties of their PCL framework, tomatch that of articular cartilage, can indirectly change the gamewhen it comes to secretion of cartilage-specific ECM in these s…”
BackgroundMethodInfluentialDepth‐dependent confined compression modulus of full‐thickness bovine articular cartilage
Schinagl, R. M., Gurskis, D., Chen, A. C., & Sah, R. L. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150404 · Cited by 646 · cited 2×
“…data on compressive and tensile moduli of articular cartilage obtained from human femoral heads are in the range of 0.079 ± 0.039–13.0 ± 4.2 MPa (Schinagl et al 1997, Shepherd and Seedhom 1999, Magnussen et al 2005) and 0.76–54.6 ± 37.6 MPa (Akizuki et al 1986, Magnussen et al 2005, Temple…”
BackgroundInfluentialWoodfield, T. B. F., Malda, J., de Wijn, J., Péters, F., Riesle, J., & van Blitterswijk, C. A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.056 · Cited by 618 · cited 4×
“Onemajor strategy in cartilage tissue engineering (CTE) is fabricating three-dimensional (3D) constructs that mimic biological and mechanical properties of human articular cartilage (Lin et al 2003, Woodfield et al 2004, Malda et al 2005, Moroni et al 2006, Woodfield et al 2009).”
BackgroundResultInfluentialFreeman, M. A. R. (1973) · Medical Entomology and Zoology · Cited by 561
Kundu, J., Shim, J.-H., Jang, J., Kim, S.-W., & Cho, D.-W. (2015) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1682 · Cited by 552 · cited 1×
“It enables easy control of fabrication parameters, such as strand size (SZ), strand spacing (SS) and strandorientation (SO), offers versatile pore geometry, 100% pore-interconnectivity, and reproducibility without the use of solvents (Izadifar et al 2015, Olubamiji et al 2016, Kundu et al 2013).”
MethodMoroni, L., de Wijn, J. R., & van Blitterswijk, C. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.023 · Cited by 534 · cited 7×
“These results support the idea that varying pore geometrical configurations changes mechanical properties of scaffolds (Zein et al 2002, Woodfield et al 2004, Moroni et al 2006, Lebourg et al 2008, Guarino et al 2007).”
BackgroundResultInfluentialEshraghi, S., & Das, S. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.002 · Cited by 524 · cited 1×
“41.9 (Hutmacher et al 2001) 35.5± 5.8 (Eshraghi and Das 2010) 44.0± 3.2 (Mondrinos et al 2006) 53± 36 (Baker et al 2016) 52± 2–67± 4 (Williams et al 2005) 105± 15 (Lu et al 2014) 59 (Shor et al 2009) 277.06± 27.66 (Doyle et al 2014) 150–200 (Wang et al 2004) 215.4± 6.6 (Lu et al…”
InfluentialAkizuki, S., Mow, V. C., Müller, F., Pita, J. C., Howell, D. S., & Manicourt, D. H. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040401 · Cited by 504 · cited 2×
“…cartilage obtained from human femoral heads are in the range of 0.079 ± 0.039–13.0 ± 4.2 MPa (Schinagl et al 1997, Shepherd and Seedhom 1999, Magnussen et al 2005) and 0.76–54.6 ± 37.6 MPa (Akizuki et al 1986, Magnussen et al 2005, Temple et al 2007, Wong and Sah 2010) respectively (see table 1).”
BackgroundResultInfluentialInfluence of molecular weight and molecular weight distribution on mechanical properties of polymers
Nunes, R. W., Martin, J. R., & Johnson, J. F. (1982) · Polymer Engineering & Science · doi:10.1002/pen.760220402 · Cited by 473 · cited 2×
“…have shown that increasing MW increased the number of tie molecules and consequently affect mechanical properties, such as elastic modulus, yield stress, fracture toughness, or impact strength of different materials (Nunes et al 1982, Walsh and Termonia 1988, KargerKocsis 1999, Tuba et al 2014).”
BackgroundBioprinting of hybrid tissue constructs with tailorable mechanical properties
Schuurman, W., Khristov, V, Pot, M. W., van Weeren, P. R., Dhert, W. J. A., & Malda, J. (2011) · Biofabrication · doi:10.1088/1758-5082/3/2/021001 · Cited by 409 · cited 5×
“Despite the popularity of PCL-based scaffolds for CTE applications in recent times, these studies neither focused nor considered how tailoring mechanical properties of their PCL framework, tomatch that of articular cartilage, can indirectly change the gamewhen it comes to secretion of cartilage-specific ECM in these s…”
BackgroundInfluentialMicroarchitectural and mechanical characterization of oriented porous polymer scaffolds
Lin, A. S. P., Barrows, T. H., Cartmell, S. H., & Guldberg, R. E. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00361-7 · Cited by 394
Athanasiou, K. A., Agarwal, A., & Dzida, F. J. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120306 · Cited by 343
Brent, B. (1981) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198101000-00023 · Cited by 339
Hyaluronic acid modified biodegradable scaffolds for cartilage tissue engineering
Yoo, H. S., Lee, E. A., Yoon, J. J., & Park, T. G. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.021 · Cited by 319 · cited 1×
“Synthetic polymers, such as polyglycolide (PGA) (Kuo and Leou 2006), poly(L‐lactide) (PLLA) (Zhao et al 2004) and poly(d,l-lactic-co-glycolic acid) (PLGA) (Yoo et al 2005), are commonly used for scaffold-based TE applications.”
BackgroundInfluence of porosity on Young's modulus and Poisson's ratio in alumina ceramics
Asmani, M., Kermel, C., Leriche, A., & Ourak, M. (2001) · Journal of the European Ceramic Society · doi:10.1016/s0955-2219(00)00314-9 · Cited by 306
Mechanical testing of electrospun PCL fibers
Croisier, F., Duwez, A.-S., Jérôme, C., Léonard, A. F., van der Werf, K. O., Dijkstra, P. J., & Bennink, M. L. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.08.015 · Cited by 305
Enhanced enzymatic saccharification of rice straw by microwave pretreatment
Ma, H., Liu, W.-W., Chen, X., Wu, Y.-J., & Yu, Z.-L. (2009) · Bioresource Technology · doi:10.1016/j.biortech.2008.08.045 · Cited by 287 · cited 1×
“…experiment I. Design of experiment called Box–Behnken design (BBD); a response-surface-methodologybased experimental design (Ferreira et al 2007, Yue et al 2008, Ma et al 2009), was used to reduce the number of experimental groups required to 13 from 27 (33) that could have been required for…”
MethodCorrelation between Young's modulus and porosity in porous materials
Kováčik, J. (1999) · Journal of Materials Science Letters · doi:10.1023/a:1006669914946 · Cited by 277 · cited 1×
“With this in mind, results from this study also agreed with other studies that concluded that a relationship exists between porosity and mechanical properties of scaffolds (Kovacik 1999, Asmania et al 2001, Zein et al 2002, Moroni et al 2006, Kovácik 2008).”
ResultChen, S. S., Falcovitz, Y. H., Schneiderman, R., Maroudas, A., & Sah, R. L. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2001.0424 · Cited by 266
Precision extruding deposition and characterization of cellular poly‐ε‐caprolactone tissue scaffolds
Wang, F., Shor, L., Darling, A., Khalil, S., Sun, W., Güçeri, S., & Lau, A. (2004) · Rapid Prototyping Journal · doi:10.1108/13552540410512525 · Cited by 241 · cited 1×
“…al 2006) 53± 36 (Baker et al 2016) 52± 2–67± 4 (Williams et al 2005) 105± 15 (Lu et al 2014) 59 (Shor et al 2009) 277.06± 27.66 (Doyle et al 2014) 150–200 (Wang et al 2004) 215.4± 6.6 (Lu et al 2014) Rapid-prototyping (RP)-based 3D-printing technology circumvents most of the limitations of…”
InfluentialThe effect of PEGT/PBT scaffold architecture on the composition of tissue engineered cartilage
Malda, J., Woodfield, T. B. F., van der Vloodt, F., Wilson, C., Martens, D. E., Tramper, J., van Blitterswijk, C. A., & Riesle, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.046 · Cited by 234
Mondrinos, M. J., Dembzynski, R., Lu, L., Byrapogu, V. K. C., Wootton, D. M., Lelkes, P. I., & Zhou, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.049 · Cited by 225 · cited 7×
“These results support the idea that varying pore geometrical configurations changes mechanical properties of scaffolds (Zein et al 2002, Woodfield et al 2004, Moroni et al 2006, Lebourg et al 2008, Guarino et al 2007).”
BackgroundResultInfluentialBaker, S. R., Banerjee, S., Bonin, K., & Guthold, M. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.09.102 · Cited by 224 · cited 2×
“41.9 (Hutmacher et al 2001) 35.5± 5.8 (Eshraghi and Das 2010) 44.0± 3.2 (Mondrinos et al 2006) 53± 36 (Baker et al 2016) 52± 2–67± 4 (Williams et al 2005) 105± 15 (Lu et al 2014) 59 (Shor et al 2009) 277.06± 27.66 (Doyle et al 2014) 150–200 (Wang et al 2004) 215.4± 6.6 (Lu et al…”
BackgroundInfluentialChitosan Scaffolds Containing Hyaluronic Acid for Cartilage Tissue Engineering
Correia, C. R., Teixeira, L. M., Moroni, L., Reis, R. L., van Blitterswijk, C., Karperien, M., & Mano, J. F. (2011) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2010.0467 · Cited by 211
Bhardwaj, N., Nguyen, Q. T., Chen, A. C., Kaplan, D. L., Sah, R. L., & Kundu, S. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.061 · Cited by 198 · cited 1×
“Naturally occurring biomaterials, such as collagen (Lu et al 2010), fibroin (Talukdar et al 2011), chitosan (Bhardwaj et al 2011), and hyaluronic acid (Correia et al 2011) have shown great potential for CTE, especially in terms of promoting chondrogenesis and mimicking biochemical properties of…”
BackgroundShor, L., Güçeri, S., Chang, R., Gordon, J., Kang, Q., Hartsock, L., An, Y., & Sun, W. (2009) · Biofabrication · doi:10.1088/1758-5082/1/1/015003 · Cited by 198 · cited 1×
“…35.5± 5.8 (Eshraghi and Das 2010) 44.0± 3.2 (Mondrinos et al 2006) 53± 36 (Baker et al 2016) 52± 2–67± 4 (Williams et al 2005) 105± 15 (Lu et al 2014) 59 (Shor et al 2009) 277.06± 27.66 (Doyle et al 2014) 150–200 (Wang et al 2004) 215.4± 6.6 (Lu et al 2014) Rapid-prototyping (RP)-based…”
InfluentialWong, M., Siegrist, M., & Cao, X. (1999) · Matrix Biology · doi:10.1016/s0945-053x(99)00029-3 · Cited by 171 · cited 2×
“…the use of PCL scaffolds listed in table 1 as a framework for CTE applications will result in stress-shielding of mechanotransduction and hindering the transmision of mechanical stimuli directed at cells in these scaffolds and, consequently affect ECM secretion (Sah et al 1989, Wong et al 1999).”
BackgroundMethodInfluentialJang, J., Seol, Y.-J., Kim, H. J., Kundu, J., Kim, S. W., & Cho, D.-W. (2014) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.05.004 · Cited by 166 · cited 1×
“While both components play roles in the overall mechanical behaviour of the constructs, the compressive modulus of alginate is negligible compared to PCL (Williams et al 2005, Jang et al 2014, Lu et al 2014).”
BackgroundAge- and site-associated biomechanical weakening of human articular cartilage of the femoral condyle
Temple, M. M., Bae, W. C., Chen, M. Q., Lotz, M., Amiel, D., Coutts, R. D., & Sah, R. L. (2007) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2007.03.005 · Cited by 135
Izadifar, Z., Chang, T., Kulyk, W., Chen, X., & Eames, B. F. (2016) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2015.0307 · Cited by 131 · cited 3×
“These 3D-printed hybrid constructs biologically mimic native articular cartilage, enabling secretion of cartilage-specific ECM (Schuurman et al 2011, Izadifar et al 2015,Olubamiji et al 2016).”
BackgroundMethodSelf-citationTalukdar, S., Nguyen, Q. T., Chen, A. C., Sah, R. L., & Kundu, S. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.027 · Cited by 121 · cited 1×
“Naturally occurring biomaterials, such as collagen (Lu et al 2010), fibroin (Talukdar et al 2011), chitosan (Bhardwaj et al 2011), and hyaluronic acid (Correia et al 2011) have shown great potential for CTE, especially in terms of promoting chondrogenesis and mimicking biochemical properties of…”
BackgroundCorrelo, V. M., Boesel, L. F., Pinho, E., Costa-Pinto, A. R., da Silva, M. A., Bhattacharya, M., Mano, J. F., Neves, N. M., & Reis, R. L. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32221 · Cited by 121
Cross-linking methods of electrospun fibrinogen scaffolds for tissue engineering applications
Sell, S. A., Francis, M. P., Garg, K., McClure, M. J., Simpson, D. G., & Bowlin, G. L. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/4/045001 · Cited by 105 · cited 1×
“However, these natural biomaterials are expensive, exhibit poor mechanical properties and relatively quick degradation rates, especially when not crosslinked (Sell et al 2008, Zeugolis et al 2008).”
BackgroundLi, M. G., Tian, X. Y., & Chen, D. (2009) · Biofabrication · doi:10.1088/1758-5082/1/3/032001 · Cited by 102 · cited 1×
“Cross-section of pore morphology shown in figures 2 and 3 demonstrated that strands in all cases maintained cylindrical shape, except in the contact area where strand fusion caused a ‘spreading process’ previously described in a simulation experiment of these 3D-printed scaffolds in (Li et al2009).”
BackgroundSelf-citationLu, H., Ko, Y., Kawazoe, N., & Chen, G. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.019 · Cited by 97 · cited 3×
“…techniques, such as selective laser sintering (SLS), injection moulding, precision extruding deposition (PED), fused deposition modelling (FDM), drop on demand printing (DDP) etc, for fabrication of these PCL scaffolds (Lebourg et al 2008, Lu et al 2010, Lu et al 2014,Minton et al 2014).”
BackgroundMethodEffect of voxel size on 3D micro-CT analysis of cortical bone porosity
Cooper, D., Turinsky, A., Sensen, C., & Hallgrimsson, B. (2007) · Calcified Tissue International · doi:10.1007/s00223-005-0274-6 · Cited by 96 · cited 1×
“A region of interest that consists of 4.0 × 4.0 mm2 of 80 image slices selected from each dataset were thresholded to distinguish scaffolds frombackground noise and pore voids as previously described in (Lin et al 2003, Cooper et al 2007).”
MethodInfluentialSelf-citationLebourg, M., Serra, R. S. I., Estellés, J. M., Hernández‐Sánchez, F., Ribelles, J. L. G., & Suay, J. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3282-4 · Cited by 81
Porosity and mechanical properties relationship in PCL porous scaffolds.
Guarino, V., Causa, F., & Ambrosio, L. (2012) · PubMed · Cited by 74
Démarteau, O., Pillet, L., Inaebnit, A., Borens, O., & Quinn, T. M. (2006) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2005.12.011 · Cited by 65
Zhao, J., Yuan, X., Cui, Y., Ge, Q.-B., & Yao, K. (2003) · Journal of Applied Polymer Science · doi:10.1002/app.13323 · Cited by 55 · cited 3×
“Interestingly, composite of PLLA and poly-ε-caprolactone (PCL) investaged for CTE concluded that addition of PCL enabled reduction of rigidity, thereby causing increased visco-elasticity and flexibility of these scaffolds (Zhao et al 2004).”
BackgroundWoodfield, T. B. F., Moroni, L., & Malda, J. (2009) · Combinatorial Chemistry & High Throughput Screening · doi:10.2174/138620709788681899 · Cited by 50
Doyle, H., Lohfeld, S., & McHugh, P. E. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0913-4 · Cited by 47
Lu, L. N., Zhang, Q., Wootton, D. M., Chiou, R. Y., Li, D., Lu, B., Lelkes, P. I., & Zhou, J. G. (2014) · Journal of Applied Biomaterials & Functional Materials · doi:10.5301/jabfm.5000163 · Cited by 45
Tiptipakorn, S., Keungputpong, N., Phothiphiphit, S., & Rimdusit, S. (2015) · Journal of Applied Polymer Science · doi:10.1002/app.41915 · Cited by 45 · cited 1×
“…several investigators have studied the effect of molecular weight (MW) on biomaterials’ and scaffolds’mechanical parameters such as elastic modulus, yield stress, fracture toughness, and impact strength (Nunes et al 1982, Walsh andTermonia 1988, Tuba et al 2014, Tiptipakorn et al, 2015).”
BackgroundKuo, Y., & Leou, S. (2006) · Biotechnology Progress · doi:10.1002/bp0602303 · Cited by 42
Influence of PCL molecular weight on mesenchymal stromal cell differentiation
Hendrikson, W. J., Rouwkema, J., van Blitterswijk, C., & Moroni, L. (2015) · RSC Advances · doi:10.1039/c5ra08048g · Cited by 40 · cited 1×
“Furthermore, biosynthesis activities of cells in the vicinity of articular cartilage or in CTE constructs are sensitive to mechanical stimuli (Hendrikson et al 2015).”
BackgroundMinton, J. A., Janney, C. S., Akbarzadeh, R., Focke, C., Subramanian, A., Smith, T. A., McKinney, J., Liu, J., Schmitz, J. E., James, P. F., et al. (2014) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2014.953016 · Cited by 30
Tuba, F., Oláh, L., & Nagy, P. (2014) · eXPRESS Polymer Letters · doi:10.3144/expresspolymlett.2014.88 · Cited by 26 · cited 2×
“…have shown that increasing MW increased the number of tie molecules and consequently affect mechanical properties, such as elastic modulus, yield stress, fracture toughness, or impact strength of different materials (Nunes et al 1982, Walsh and Termonia 1988, KargerKocsis 1999, Tuba et al 2014).”
BackgroundElectro-spinning of pure collagen nano-fibres–just an expensive way to make gelatin?
Zeugolis, D. I., Khew, S. T., Yew, E. S. Y., Ekaputra, A. K., Tong, Y. W., Yung, L.-Y. L., Hutmacher, D. W., Sheppard, C., & Raghunath, M. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.02.009 · Cited by 1 · cited 1×
“However, these natural biomaterials are expensive, exhibit poor mechanical properties and relatively quick degradation rates, especially when not crosslinked (Sell et al 2008, Zeugolis et al 2008).”
Background
Cited by
A comparison of different bioinks for 3D bioprinting of fibrocartilage and hyaline cartilage
Daly, A. C., Critchley, S. E., Rencsok, E. M., & Kelly, D. J. (2016) · Biofabrication · doi:10.1088/1758-5090/8/4/045002 · Cited by 436
Bioprinting: From Tissue and Organ Development to in Vitro Models
Mota, C., Camarero-Espinosa, S., Baker, M. B., Wieringa, P., & Moroni, L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00789 · Cited by 345
3D Bioprinting for Cartilage and Osteochondral Tissue Engineering
Daly, A. C., Freeman, F. E., Gonzalez‐Fernandez, T., Critchley, S. E., Nulty, J., & Kelly, D. J. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700298 · Cited by 334
Yi, B., Xu, Q., & Liu, W. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.12.005 · Cited by 304
Prasadh, S., & Wong, R. C. W. (2018) · Oral Science International · doi:10.1016/s1348-8643(18)30005-3 · Cited by 283
Metadata
- Authors
- Olubamiji, A. D., Izadifar, Z., Si, J. L., Cooper, D. M. L., Eames, B. F., & Chen, D. X.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2016-06-22
- Volume
- 8
- Issue
- 2
- Pages
- 025020
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2460239666
- Cited by
- 174
- References
- 56
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.