Performance Evaluation of Blood Glucose Monitoring Devices
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Many new technologies are being applied to measure blood glucose concentrations, but there is a lack of a standardized approach to evaluate performance of these devices. We sought to identify the key elements in evaluating the performance of devices for measuring blood glucose. We examined these elements in a multicenter study of four brands of glucose meters that are commonly used by diabetic patients. We tested control materials, spiked whole blood specimens, and 461 heparinized whole blood specimens in triplicate by each of the four brand glucose meters, and analyzed the plasma glucose concentrations of these specimens by a hexokinase (HK) method that incorporated reference materials developed by National Institute of Standards and Technology. Testing with glucose meters was performed at three sites, with multiple operators, meters, and representative lots of reagents. We evaluated the systematic bias, random error, and clinical significance of glucose meters. Meters were precise with a coefficient of variation of <4% across a wide range of glucose concentrations. Slopes significantly different from 1.0 were observed for two meters with 11-13% and -11% to -13% at the 95% confidence interval level by the linear regression of meter results versus the HK method from 33 to 481 mg/dL (correlation coefficient >0.98 and standard error of estimation S(y/x) <13 mg/dL for both meters). Analysis of the clinical significance of bias by Clarke Error Grid showed that results of the four meters were outside the accurate zone (26.5%, 2.4%, 1.5%, and 5.6%). Only a small number of the results showed clinically significant bias, mostly in the hypoglycemic range. Meters performed consistently throughout the study and, generally, were precise, although precision varied at extremely high or low glucose concentrations. Two of the glucose meters had substantial systematic bias when compared with an HK method, indicating a need for improving calibration and standardization. Analytical performance varied over the physiological range of glucose values so that separate accuracy and precision goals should be defined for hypoglycemic, normoglycemic, and hyperglycemic ranges. This study describes the current state of performance of blood glucose monitoring devices and points out those factors that should be assessed during evaluation of new devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Diabetes trends in the U.S.: 1990-1998.
Mokdad, A. H., Ford, E. S., Bowman, B. A., Nelson, D. E., Engelgau, M. M., Vinicor, F., & Marks, J. S. (2000) · Diabetes Care · doi:10.2337/diacare.23.9.1278 · Cited by 1,042
Tang, Z., Lee, J. H., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-1135-eodhlo · Cited by 293
Skeie, S., Thue, G., Nerhus, K., & Sandberg, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.994 · Cited by 131 · cited 1×
“There are additional operators and environmental factors that may affect testing in a home environment, 68 and determination of glucose meter performance in a home setting would require a separate study.”
Ladenson, J. H., Tsai, L.-M. B., Michael, J. M., Kessler, G., & Joist, J. H. (1974) · American Journal of Clinical Pathology · doi:10.1093/ajcp/62.4.545 · Cited by 114
IFCC recommendation on reporting results for blood glucose
(2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00431-4 · Cited by 110
Newer portable glucose meters—analytical improvement compared with previous generation devices?
Weitgasser, R., Gappmayer, B., & Pichler, M. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.10.1821 · Cited by 85
M. Stahl, L. G. M. J. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133612 · Cited by 79 · cited 1×
“As described by Stahl et al., 37 special measures are required to achieve accurate analysis of glucose concentrations.”
Differences between capillary and venous blood glucose during oral glucose tolerance tests
Larsson-Cohn, U. (1976) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517609081941 · Cited by 65
Cited by
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, K., & Nichols, J. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300446 · Cited by 406
Self-citationThe Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
Breton, M. D., & Kovatchev, B. P. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400309 · Cited by 103
Monitoring glycemic control: the importance of self-monitoring of blood glucose
Renard, E. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.07.052 · Cited by 99
Assessing the quality of glucose monitor studies: a critical evaluation of published reports
Mahoney, J., & Ellison, J. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.083493 · Cited by 48
Metadata
- Authors
- Chen, E. T., Nichols, J. H., Duh, S.-H., & Hortin, G.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2003-10
- Volume
- 5
- Issue
- 5
- Pages
- 749-768
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2000314390
- Cited by
- 96
- References
- 9
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance Evaluation of Blood Glucose Monitoring Devices. https://app.cochat.ai/papers/10.1089/152091503322526969
- The paper
- Chen, E. T., Nichols, J. H., Duh, S.-H., & Hortin, G. (2003). Performance Evaluation of Blood Glucose Monitoring Devices. Diabetes Technology & Therapeutics. https://doi.org/10.1089/152091503322526969
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.