Continuous Glucose Monitoring in Normal Mice and Mice with Prediabetes and Diabetes
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
It is well established that the key to minimizing diabetes-associated complications, in both type 1 and type 2 diabetes, is tight regulation of blood glucose levels. Currently the major approach to regulating blood glucose levels in patients with diabetes relies on external blood glucose monitors. However, poor patient compliance usually results in limited insights into the dynamic range of blood glucose levels (i.e., hyperglycemia vs. hypoglycemia), and inadequate prediction and control of blood glucose levels in these patients. Implantable glucose sensors hold promise for controlling blood glucose levels, but currently these sensors have only limited in vivo life span. Recently we have developed an extremely robust murine model for implantable glucose sensors. In the present study, we have extended this model by developing a complete system for real-time continuous glucose monitoring in normal mice and mice with prediabetes and diabetes (type 1). These studies demonstrated that (1) glucose sensors can be implanted and maintained subcutaneously in the mice; (2) continuous glucose sensor data can be obtained for at least 5 days; and (3) subcutaneous blood glucose sensing paralleled blood glucose levels in normal mice and mice with prediabetes and diabetes. Subcutaneous blood glucose sensing also successfully tracked changes in blood glucose levels induced in the mice with diabetes by administration of oral glucose or insulin. These results mirror the results for subcutaneous blood glucose sensing seen in both normal subjects and patients with diabetes, and therefore validate both our continuous glucose monitoring system in the mouse, and the use of the mouse as a model for implantable glucose sensing in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE NOD MOUSE: A Model of Immune Dysregulation
Anderson, M. S., & Bluestone, J. A. (2005) · Annual Review of Immunology · doi:10.1146/annurev.immunol.23.021704.115643 · Cited by 1,113
The NOD mouse model of type 1 diabetes: As good as it gets?
Atkinson, M. A., & Leiter, E. H. (1999) · Nature Medicine · doi:10.1038/9442 · Cited by 588 · cited 1×
“6,7 Utilizing these NOD mice we demonstrated that (1) glucose sensors can be implanted and maintained subcutaneously in mice and (2) continuous glucose sensor CGS) data can be obtained for at least 5 days.”
Klueh, U., Dorsky, D. I., & Kreutzer, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.017 · Cited by 87
Self-citationA new amperometric glucose microsensor: in vitro and short-term in vivo evaluation
Ward, W. K., Jansen, L. B., Anderson, E., Reach, G., Klein, J.-C., & Wilson, G. S. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00268-8 · Cited by 81
Cited by
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102
Metabolic Biofouling of Glucose Sensors in Vivo : Role of Tissue Microhemorrhages
Klueh, U., Liu, Z., Feldman, B., Henning, T. P., Cho, B., Ouyang, T., & Kreutzer, D. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500313 · Cited by 63
Self-citationCritical role of tissue mast cells in controlling long-term glucose sensor function in vivo
Klueh, U., Kaur, M., Qiao, Y., & Kreutzer, D. L. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.023 · Cited by 48
“Thus, we began our studies by characterizing longterm sensor function in our mouse model of CGM [9,10].”
MethodSelf-citationLow, J. T., Mitchell, J. M., Do, O. H., Bax, J., Rawlings, A., Zavortink, M., Morgan, G., Parton, R. G., Gaisano, H. Y., & Thorn, P. (2013) · Diabetologia · doi:10.1007/s00125-013-3019-5 · Cited by 43
“This range is very close to the range of fasting to maximal glucose levels in both mouse (5–10mmol/l) [37] and humans after a meal (5–8 mmol/l) [38] and indicates that normally the beta cells are operating within their optimal A”
Background
Metadata
- Authors
- Klueh, U., Liu, Z., Cho, B., Ouyang, T., Feldman, B., Henning, T. P., Kaur, M., & Kreutzer, D.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2006-06
- Volume
- 8
- Issue
- 3
- Pages
- 402-412
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2051152083
- Cited by
- 62
- References
- 4
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Glucose Monitoring in Normal Mice and Mice with Prediabetes and Diabetes. https://app.cochat.ai/papers/10.1089/dia.2006.8.402
- The paper
- Klueh, U., Liu, Z., Cho, B., Ouyang, T., Feldman, B., Henning, T. P., Kaur, M., & Kreutzer, D. (2006). Continuous Glucose Monitoring in Normal Mice and Mice with Prediabetes and Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2006.8.402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.