The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Recommendations for Standardizing Glucose Reporting and Analysis to Optimize Clinical Decision Making in Diabetes: The Ambulatory Glucose Profile (AGP)
Abstract
Abstract Underutilization of glucose data and lack of easy and standardized glucose data collection, analysis, visualization, and guided clinical decision making are key contributors to poor glycemic control among individuals with type 1 diabetes. An expert panel of diabetes specialists, facilitated by the International Diabetes Center and sponsored by the Helmsley Charitable Trust, met in 2012 to discuss recommendations for standardization of analysis and presentation of glucose monitoring data, with the initial focus on data derived from CGM systems. The panel members were introduced to a universal software report, the Ambulatory Glucose Profile (AGP), and asked to provide feedback on its content and functionality, both as a research tool and in clinical settings. This paper provides a summary of the topics and issues discussed during the meeting and presents recommendations from the expert panel regarding the need to standardize glucose profile summary metrics and the value of a uniform glucose report to aid clinicians, researchers, and patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Originally created by Mazze et. al. (68), the standardized AGP report was further developed by the International Diabetes Center and now incorporates all the core CGM metrics and targets along with a 14-day composite glucose profile as an integral component of clinical decision making (24).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [24]
In the citing paper
“The key benefits of CGM include real-time data monitoring for people with T1D and access for them and their HCPs to complete glucose datasets17; both of which help people to achieve their target time spent within the acceptable range (time in range [TIR]: 3.9–10.0 mmol/L [70–180 mg/dL]) and avoid hyper- and hypoglycemia.18”
From Increased Time in Range and Fewer Missed Bolus Injections After Introduction of a Smart Connected Insulin Pen (2020) · cites this paper as [18]
Citations
Cites
The Triple Aim: Care, Health, And Cost
Berwick, D. M., Nolan, T. W., & Whittington, J. (2008) · Health Affairs · doi:10.1377/hlthaff.27.3.759 · Cited by 5,136
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
Effect of a multifactorial intervention on mortality in type 2 diabetes
Gæde, P., Lund-Andersen, H., Parving, H.-H., & Pedersen, O. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0706245 · Cited by 3,465 · cited 1×
“37”
Monnier, L., Mas, E., Ginet, C., Michel, F., Villon, L., Cristol, J.-P., & Colette, C. (2006) · JAMA · doi:10.1001/jama.295.14.1681 · Cited by 2,444
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Severe hypoglycemia and risks of vascular events and death
Zoungas, S., Patel, A., Chalmers, J., de Galan, B. E., Li, Q., Billot, L., Woodward, M., Ninomiya, T., Neal, B., MacMahon, S., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1003795 · Cited by 1,471
Defining and Reporting Hypoglycemia in Diabetes
American Diabetes Association Workgroup on Hypoglycemia (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1245 · Cited by 1,146
Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes.
Cryer, P. (2002) · Diabetologia · doi:10.1007/s00125-002-0822-9 · Cited by 794
Wild, D., von Maltzahn, R., Brohan, E., Christensen, T., Clauson, P., & Gonder-Frederick, L. (2007) · Patient Education and Counseling · doi:10.1016/j.pec.2007.05.003 · Cited by 545
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Research works printed but not linked: 4
- McGill J.B, , Chen V, , Beck RW. Diabetes management among adults under excellent control in the Type 1 Diabetes Exchange Clinic Registry: how do they do it? Oral presentation #186 at the European Association for the Study of Diabetes Meeting, Berlin, 2012.
- Self-monitoring of blood glucose among adults with diabetes—United States, 1997–2006. MMWR Morb Mortal Wkly Rep, 2007; 56:1133–1137.
- Adi S, , Beck RW, , DuBose SN, , Bode BW, , Peters AL, , Hirsch IB, , Miller KM. T1D Exchange Clinic Network: A comparison of users, nonusers of real-time continuous glucose monitoring (CGM) with type 1 diabetes (T1D) in the T1D Exchange. Poster presentation at the Diabetes Technology Society Meeting, October 27–292011.
- Dunn TC, , Crouther N. Assessment of the variance of the Ambulatory Glucose Profile over 3–20 days of continuous glucose monitoring. Abstract poster presented at the European Association for the Study of Diabetes Meeting, Stockholm, September 2010.
Cited by
Sorted by citations
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
“However, before CGM is widely adopted, data must be reported and analyzed using a standard universal template that is predictable and intuitive (75).”
MethodBattelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
“in a consensus conference held in 2012 (82) [E] and is recommended by this consensus group as a standard for visualization of CGM data.”
BackgroundSelf-citationContinuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 768
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetes Care · doi:10.2337/dci21-0043 · Cited by 699
Glucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring
Bergenstal, R. M., Beck, R. W., Close, K. L., Grunberger, G., Sacks, D. B., Kowalski, A., Brown, A. S., Heinemann, L., Aleppo, G., Ryan, D. B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1581 · Cited by 684
Self-citationThe relationships between time in range, hyperglycemia metrics, and HbA1c
Beck, R. W., Bergenstal, R. M., Cheng, P., Kollman, C., Carlson, A. L., Johnson, M. L., & Rodbard, D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818822496 · Cited by 479
Self-citationThe fallacy of average: how using HbA1c alone to assess glycemic control can be misleading
Beck, R. W., Connor, C. G., Mullen, D. M., Wesley, D. M., & Bergenstal, R. M. (2017) · Diabetes Care · doi:10.2337/dc17-0636 · Cited by 477
Self-citationContinuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
Holt, R. I. G., DeVries, J. H., Fischl, A. H., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, É., et al. (2021) · Diabetologia · doi:10.1007/s00125-021-05568-3 · Cited by 470
Shah, V. N., DuBose, S. N., Li, Z., Beck, R. W., Peters, A. L., Weinstock, R. S., Kruger, D., Tansey, M., Sparling, D., Woerner, S., et al. (2019) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2018-02763 · Cited by 315
Advances in technology for management of type 1 diabetes
Beck, R. W., Bergenstal, R. M., Laffel, L. M., & Pickup, J. C. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31142-0 · Cited by 242
Dunn, T. C., Xu, Y., Hayter, G., & Ajjan, R. A. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.12.015 · Cited by 239
Wright, L. A.-C., & Hirsch, I. B. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0029 · Cited by 187
Positioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170
“Such a stacked bar can be visualised alongside the standardised 24 h ambulatory glucose profile (AGP) [31] licensed bymost companies employing CGM software (Fig.”
MethodClinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes
Carlson, A. L., Mullen, D. M., & Bergenstal, R. M. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0024 · Cited by 181
Flash forward: a review of flash glucose monitoring
Leelarathna, L., & Wilmot, E. G. (2018) · Diabetic Medicine · doi:10.1111/dme.13584 · Cited by 169
“An expert group in the USA concluded that standardization of CGM data reporting using the ambulatory glucose profile would be of benefit [45] Matthaei et al.”
BackgroundGlucose Variability: A Review of Clinical Applications and Research Developments
Rodbard, D. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0092 · Cited by 154
Fear of Hypoglycemia in Children and Adolescents and Their Parents with Type 1 Diabetes
Driscoll, K. A., Raymond, J. K., Naranjo, D. M., & Patton, S. R. (2016) · Current Diabetes Reports · doi:10.1007/s11892-016-0762-2 · Cited by 165
Bergenstal, R. M. (2015) · Diabetes Care · doi:10.2337/dc15-0099 · Cited by 140
“One approach would be to use the uniform glucose report (AGP standard glucose report) as a template that breaks down hypoglycemia into the percent of time spent low (,70 mg/dL), very low (,60 mg/dL), or dangerously low (,50 mg/dL) over a 2-week period of CGM readings (18) (Fig.”
BackgroundMethodAdolfsson, P., Hartvig, N. V., Kaas, A., Møller, J. B., & Hellman, J. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0411 · Cited by 139
“0 mmol/L [70–180 mg/dL]) and avoid hyper- and hypoglycemia.(18) Reductions in HbA1c have been reported with CGM use in people on multiple daily injection (MDI) therapy,(19) and continuous subcutaneous insulin infusion therapy,(20) with reduced time spent in hypoglycemia,(20) and improved hypoglycemia awareness.”
BackgroundImproving the clinical value and utility of CGM systems: issues and recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetologia · doi:10.1007/s00125-017-4463-4 · Cited by 143
Continuous glucose monitoring: The achievement of 100 years of innovation in diabetes technology
Galindo, R. J., & Aleppo, G. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108502 · Cited by 144
“[83, 84] (Figure 1) The AGP report facilitates rapid assessment of TIR, TBR and TAR, as well as other metrics, such as average glucose and the glucose management indicator (GMI) calculation.”
BackgroundImproving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
“consensus on definitions of the various levels of time in range and hypoglycemia (in clinical practice and by CGM) is urgently required among payers and providers (21,43).”
BackgroundMethodSelf-citationHarris, D. L., Weston, P. J., Gamble, G. D., & Harding, J. E. (2020) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2020.02.079 · Cited by 126
Bailey, T. S., Grunberger, G., Bode, B. W., Handelsman, Y., Hirsch, I. B., Jovanovič, L., Roberts, V. L., Rodbard, D., Tamborlane, W. V., & Walsh, J. S. A. (2016) · Endocrine Practice · doi:10.4158/ep151124.cs · Cited by 130
Bergenstal, R. M., Bailey, T. S., Rodbard, D., Ziemen, M., Guo, H., Muehlen-Bartmer, I., & Ahmann, A. (2017) · Diabetes Care · doi:10.2337/dc16-0684 · Cited by 122
“longer-term pattern of glucose levels (17).”
Hermanns, N., Ehrmann, D., Schipfer, M., Kröger, J., Haak, T., & Kulzer, B. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.03.003 · Cited by 113
Johnson, M. L., Martens, T. W., Criego, A. B., Carlson, A. L., Simonson, G. D., & Bergenstal, R. M. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0034 · Cited by 106
“47 This recommendation was later endorsed in an international consensus conference convened in Paris in 2017 18 and is now referenced as an example of a standardized CGM report in the ADA 2019 Standards of Care (page 75) 16 and an update to the AACE consensus on use of CGM. 48 Most of the CGM…”
Yoo, J. H., Choi, M. S., Ahn, J., Park, S. W., Kim, Y., Hur, K. Y., Jin, S., Kim, G., & Kim, J. H. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0499 · Cited by 102
Okada, K., Hibi, K., Gohbara, M., Kataoka, S., Takano, K., Akiyama, E., Matsuzawa, Y., Saka, K., Maejima, N., Endo, M., et al. (2015) · Cardiovascular Diabetology · doi:10.1186/s12933-015-0275-3 · Cited by 98
“In this study, significant hyperglycemia and significant hypoglycemia were defined as a blood glucose value of ≥200 and <60 mg/dl, respectively [14, 15].”
BackgroundHow Can We Realize the Clinical Benefits of Continuous Glucose Monitoring?
Ajjan, R. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0021 · Cited by 104
“54 Retrospective or real-time CGM?”
Approach to Using Trend Arrows in the FreeStyle Libre Flash Glucose Monitoring Systems in Adults
Kudva, Y. C., Ahmann, A., Bergenstal, R. M., Gavin, J. R., Kruger, D. F., Midyett, L. K., Miller, E. M., & Harris, D. R. (2018) · Journal of the Endocrine Society · doi:10.1210/js.2018-00294 · Cited by 99
Rodbard, H. W., Peters, A. L., Slee, A., Cao, A., Traina, S. B., & Alba, M. (2017) · Diabetes Care · doi:10.2337/dc16-1353 · Cited by 94
Self-citationUtility of different glycemic control metrics for optimizing management of diabetes
Kohnert, K. (2015) · World Journal of Diabetes · doi:10.4239/wjd.v6.i1.17 · Cited by 101
Time in Range from Continuous Glucose Monitoring: A Novel Metric for Glycemic Control
Yoo, J. H., & Kim, J. H. (2020) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2020.0257 · Cited by 98
Beck, R. W., Raghinaru, D., Calhoun, P. M., & Bergenstal, R. M. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0380 · Cited by 86
Evolution of Diabetes Technology
Dovč, K., & Battelino, T. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.009 · Cited by 93
Georga, E. I., Protopappas, V. C., Ardigò, D., Polyzos, D. K., & Fotiadis, D. I. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0285 · Cited by 79
Prediction and prevention of hypoglycaemic events in type-1 diabetic patients using machine learning
Vehí, J., Contreras, I., Oviedo, S., Biagi, L., & Bertachi, A. (2020) · Health Informatics Journal · doi:10.1177/1460458219850682 · Cited by 76
“25 In both cases, an adverse glycaemic event was predicted whenever three consecutive BG measurements (15 min) were detected above or below their corresponding levels.”
BackgroundMethodReddy, N., Verma, N., & Dungan, K. M. (2020) · MDText.com, Inc. eBooks · Cited by 68
Borot, S., Benhamou, P., Atlan, C., Bismuth, É., Bonnemaison, É., Catargi, B., Charpentier, G., Farret, A., Filhol, N., Franc, S., et al. (2017) · Diabetes & Metabolism · doi:10.1016/j.diabet.2017.10.009 · Cited by 72
“The working group agrees with the recent attempts to standardize glycaemic data expression [46], which is helpful for categorizing patients and evaluating therapeutic impact.”
Neinstein, A., Wong, J., Look, H., Arbiter, B., Quirk, K., McCanne, S., Sun, Y., Blum, M., & Adi, S. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv104 · Cited by 66
BAJAJ, H. S., Venn, K., Ye, C., Patrick, A., Kalra, S., Khandwala, H. M., Aslam, N., Twum-Barima, D., & Aronson, R. (2016) · Diabetes Care · doi:10.2337/dc16-1582 · Cited by 65
“SD was chosen because of its general familiarity and validation history in quantifying GV from CGM (16,17), especially in our setting where two contributing variables, A1C and mean glucose, were expected to be controlled among all four cohorts.”
MethodTime in range centered diabetes care
Dovč, K., & Battelino, T. (2021) · Clinical Pediatric Endocrinology · doi:10.1297/cpe.30.1 · Cited by 66
“Bergenstal RM, Ahmann AJ, Bailey T, Beck RW, Bissen J, Buckingham B, et al. Recommendations for standardizing glucose reporting and analysis to optimize clinical decision making in diabetes: the Ambulatory Glucose Profile (AGP).”
BackgroundInfluentialDigital Technology for Diabetes
Hughes, M. S., Addala, A., & Buckingham, B. (2023) · New England Journal of Medicine · doi:10.1056/nejmra2215899 · Cited by 59
Self-citationRodbard, D. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0416 · Cited by 58
Martyn-Nemeth, P. A., Phillips, S. A., Mihailescu, D. V., Farabi, S. S., Park, C., Lipton, R. B., Idemudia, E., & Quinn, L. (2018) · Journal of Advanced Nursing · doi:10.1111/jan.13765 · Cited by 60
“This procedure is recommended by experts on the standardization of glucose reporting (Bergenstal et al., 2013; Rodbard, 2009).”
Role of Continuous Glucose Monitoring in Clinical Trials: Recommendations on Reporting
Schnell, O., Barnard, K. D., Bergenstal, R. M., Bosi, E., Garg, S. K., Guerci, B., Haak, T., Hirsch, I. B., Ji, L., Joshi, S., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0054 · Cited by 60
“Despite suggestions for standardization of endpoints, no consistency has been reached, limiting comparability between CGM systems and publications using them.(51,52) Thus, some studies use historical parameters such as the MAGE, standard deviation (SD) or coefficient of variation about mean plasma glucose level, or th…”
MethodIsh‐Shalom, M., Wainstein, J., Raz, I., & Mosenzon, O. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816653412 · Cited by 52
Treating type 1 diabetes: from strategies for insulin delivery to dual hormonal control.
McCall, A. L., & Farhy, L. S. (2013) · PubMed · Cited by 51
Augstein, P., Heinke, P., Vogt, L., Vogt, R., Rackow, C., Kohnert, K., & Salzsieder, E. (2015) · BMC Endocrine Disorders · doi:10.1186/s12902-015-0019-0 · Cited by 51
“We performed the first published factor analysis [29,30] of CGM-variables [4-7,9,10].”
InfluentialEichenlaub, M., Pleus, S., Rothenbühler, M., Bailey, T. S., Bally, L., Brazg, R., Bruttomesso, D., Diem, P., Boija, E. E., Fokkert, M. J., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0465 · Cited by 51
Continuous glucose monitoring in cystic fibrosis – A practical guide
Chan, C. L., Ode, K. L., Granados, A., Moheet, A. A., Moran, A., & Hameed, S. A. (2019) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2019.08.025 · Cited by 50
Glucodensities: A new representation of glucose profiles using distributional data analysis
Matabuena, M., Petersen, A., Vidal, J. C., & Gude, F. (2021) · Statistical Methods in Medical Research · doi:10.1177/0962280221998064 · Cited by 47
“In 2012, a panel of experts discussed how to represent CGM data in an “easy to view format”.(19) They also analyzed the convenience of using glycemic variability measures and other summary measures such as time in range to extract the CGM’s recorded information.”
BackgroundSchaupp, L. A., Donsa, K., Neubauer, K. M., Mader, J. K., Aberer, F., Höll, B., Spat, S., Augustin, T., Beck, P., Pieber, T. R., et al. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0343 · Cited by 48
Reference Guide for Integrating Continuous Glucose Monitoring Into Clinical Practice
Kruger, D. F., Edelman, S. V., Hinnen, D. A., & Parkin, C. G. (2019) · The Diabetes Educator · doi:10.1177/0145721718818066 · Cited by 55
Wearable systems and mobile applications for diabetes disease management
Georga, E. I., Protopappas, V. C., Bellos, C. V., & Fotiadis, D. I. (2014) · Health and Technology · doi:10.1007/s12553-014-0082-y · Cited by 47
“sured [14, 15].”
MethodTime-in-range for monitoring glucose control: Is it time for a change?
Bellido, V., Pinés-Corrales, P. J., Villar‐Taibo, R., & Ampudia‐Blasco, F. J. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108917 · Cited by 49
First Clinical Experience with Retrospective Flash Glucose Monitoring (FGM) Analysis in South Africa
Distiller, L. A., CRANSTON, I. C., & Mazze, R. S. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816648165 · Cited by 45
“However, the adoption of CGM for clinical decision making and research remains elusive.(3,4) Scheiner recently reviewed the advantages of, and problems with retrospective analysis of CGM data, suggesting that a structured approach to data interpretation may hold the key to future success.”
BackgroundInternational consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S. K., Heinemann, L., Hirsch, I. B., Amiel, S. A., et al. (2018) · Yearbook of pediatric endocrinology · doi:10.1530/ey.15.10.10 · Cited by 44
Mo, Y., Lu, J., & Zhou, J. (2023) · Journal of Diabetes Investigation · doi:10.1111/jdi.14112 · Cited by 53
“Ambulatory glucose pro fi le condenses CGM data into a 24-h representation, and IQR, represented by the 25th to 75th percentile trend lines on ambulatory glucose pro fi le, serves as a powerful visual tool for assessing GV 19,20 .”
MethodMontaser, E., Fabris, C., & Kovatchev, B. P. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0104 · Cited by 44
Emerging Diabetes Technologies: Continuous Glucose Monitors/Artificial Pancreases
ALMURASHI, A. M., Rodriguez, E., & Garg, S. K. (2023) · Journal of the Indian Institute of Science · doi:10.1007/s41745-022-00348-3 · Cited by 55
Basal Glucose Can Be Controlled, but the Prandial Problem Persists—It’s the Next Target!
Riddle, M. C. (2017) · Diabetes Care · doi:10.2337/dc16-2380 · Cited by 43
“0 mmol/L) as a summary indicator of glycemic control (34).”
BackgroundThe FLAT-SUGAR Trial Investigators (2015) · Diabetes Care · doi:10.2337/dc14-2689 · Cited by 38
Consensus recommendations for the use of Ambulatory Glucose Profile in clinical practice
Matthaei, S., Antuna, R., Bosi, E., Evans, M. L., Geelhoed-Duijvestijn, N., & Joubert, M. (2014) · The British Journal of Diabetes · doi:10.15277/bjdvd.2014.046 · Cited by 38
Garg, S. K., & Aktürk, H. K. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0142 · Cited by 37
Effect of Professional CGM (pCGM) on Glucose Management in Type 2 Diabetes Patients in Primary Care
Simonson, G. D., Bergenstal, R. M., Johnson, M. L., Davidson, J. L., & Martens, T. W. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296821998724 · Cited by 37
Self-citationConget, I., Castañeda, J., Petrovski, G., Guerci, B., Racault, A.-S., Reznik, Y., Cohen, O., Runzis, S., de Portu, S., Aronson, R., et al. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0159 · Cited by 38
Czupryniak, L., Dzida, G. J., Fichna, P., Jarosz-Chobot, P. A., Gumprecht, J., Klupa, T., Myśliwiec, M., Szadkowska, A., Bomba-Opon, D. A., Czajkowski, K., et al. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01229-9 · Cited by 35
Continuous Glucose Monitoring to Optimize Management of Diabetes in Patients with Advanced CKD
Galindo, R. J., de Boer, I. H., Neumiller, J. J., & Tuttle, K. R. (2022) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04510422 · Cited by 35
Key indices of glycaemic variability for application in diabetes clinical practice
Monnier, L., Bonnet, F., Colette, C., Renard, É., & Owens, D. R. (2023) · Diabetes & Metabolism · doi:10.1016/j.diabet.2023.101488 · Cited by 35
Technological advances shaping diabetes care
Aktürk, H. K., & Garg, S. K. (2019) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000467 · Cited by 34
Donsa, K., Beck, P., Höll, B., Mader, J. K., Schaupp, L. A., Plank, J., Neubauer, K. M., Baumgärtner, C., & Pieber, T. R. (2016) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2016.03.007 · Cited by 35
Perkins, B. A., Cherney, D. Z. I., Soleymanlou, N., Lee, J. A., Partridge, H., Menezes, H. T., Zinman, B., Mazze, R., Fagan, N. M., Kaspers, S., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0141085 · Cited by 32
“CGM results were analyzed and averaged over 2-week AGP assessment periods to provide modal day estimates of pre-specified conventional parameters of glycemic exposure, glycemic variability, and glycemic stability during the 2-week placebo runin period (baseline), weeks 7 and 8 (end-of-treatment) and the two week perio…”
MethodClinical Application of Time in Range and Other Metrics
Aleppo, G. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0093 · Cited by 32
Senior, P. A., Bellin, M. D., Alejandro, R., Yankey, J. W., Clarke, W. R., Qidwai, J. C., Schwieger, T., Eggerman, T. L., Robien, M. A., & Rickels, M. R. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0289 · Cited by 33
“We used the software-generated CGMS SD and CGMS CV available at the start of the CIT trials as measures of glycemic variability for this analysis as there is no consensus for how best to use CGMS to quantify glucose variability.(20) If we had had access to raw sensor data, it would have been possible to calculate othe…”
MethodAjjan, R. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16098 · Cited by 35
Understanding Continuous Glucose Monitoring Data
Bergenstal, R. (2018) · Role of Continuous Glucose Monitoring in Diabetes Treatment · doi:10.2337/db20181-20 · Cited by 37
Bellei, E. A., Biduski, D., Lisboa, H. R. K., & Marchi, A. C. B. D. (2019) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2018.0329 · Cited by 35
“65–71 The interactive visualization within Soins DM aims to facilitate the identification of patterns and treatment failures, the understanding of impact food have on glycemia, and how food interacts with exercise and insulin to prevent hypo-and hyperglycemia.”
Carlson, A. L., Criego, A. B., Martens, T. W., & Bergenstal, R. M. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.010 · Cited by 33
Patton, S. R., Noser, A. E., Clements, M. A., Dolan, L. M., & Powers, S. W. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0389 · Cited by 29
“Mild dysglycemia” in type 2 diabetes: to be neglected or not?
Monnier, L., Colette, C., Dejager, S., & Owens, D. R. (2014) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2014.12.004 · Cited by 28
“Such an observation therefore indicates that, in persons with diabetes mellitus, there exist large inter-individual variations in blood glucose patterns (Bergenstal et al., 2013).”
BackgroundUse of Technology When Assessing Adherence to Diabetes Self-Management Behaviors
Driscoll, K. A., & Young-Hyman, D. L. (2014) · Current Diabetes Reports · doi:10.1007/s11892-014-0521-1 · Cited by 27
Carlson, A. L., Martens, T. W., Johnson, L., & Criego, A. B. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0241 · Cited by 28
Continuous glucose monitoring in persons with type 2 diabetes not using insulin
Cowart, K., Updike, W. H., & Franks, R. B. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1992274 · Cited by 29
“CGM allows the PWD and clinician to analyze the impact that diet, exercise, stress, and medication can have on the management of T2D[10].”
BackgroundInfluentialSoftware Packages and Tools for the Analysis of Continuous Glucose Monitoring Data
Piersanti, A., Giurato, F., Göbl, C. S., Burattini, L., Tura, A., & Morettini, M. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0237 · Cited by 31
“16 Such template is currently adopted by the majority of CGM device manufacturers; however, international consensus on CGM data analysis and standard metrics that should be computed for clinical care has been reached only recently.”
Assessing the value of the Ambulatory Glucose Profile in clinical practice
Matthaei, S. (2014) · The British Journal of Diabetes · doi:10.15277/bjdvd.2014.045 · Cited by 27
Accuracy Evaluation of CONTOUR®PLUS Compared With Four Blood Glucose Monitoring Systems
Dunne, N., Viggiani, M. T., Pardo, S. A., Robinson, C., & Parkes, J. L. (2015) · Diabetes Therapy · doi:10.1007/s13300-015-0121-3 · Cited by 27
Update on the American Diabetes Association Standards of Medical Care
Zitkus, B. S. (2014) · The Nurse Practitioner · doi:10.1097/01.npr.0000451880.48790.50 · Cited by 25
Rafiei, H., Robinson, E., Barry, J., Jung, M. E., & Little, J. P. (2019) · European Journal of Sport Science · doi:10.1080/17461391.2019.1576772 · Cited by 25
“…can best be measured using continuous glucose monitoring (CGM) that is more informative than fasting plasma glucose or HbA1C as it allows for monitoring minute by minute changes in glucose levels in response to a short-term intervention and under free-living conditions (Bergenstal et al., 2013).”
BackgroundPractical guidance for using the FreeStyle Libre flash continuous glucose monitoring in primary care
Unger, J., Kushner, P. R., & Anderson, J. E. (2020) · Postgraduate Medicine · doi:10.1080/00325481.2020.1744393 · Cited by 27
“When reviewing the glucose data, we suggest you start with the AGP report [47], which is common to all download programs (Figure 2).”
MethodTime-in-range and frequency of continuous glucose monitoring: Recommendations for South Asia
Kesavadev, J., Misra, A., Saboo, B., Agarwal, S., Sosale, A., Joshi, S., Hussain, A., Somasundaram, N. P., Basit, A., Choudhary, P., et al. (2021) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2021.102345 · Cited by 24
Utilizing continuous glucose monitoring in primary care practice: What the numbers mean
Edelman, S. V., Cavaiola, T. S., BOEDER, S. C., & Pettus, J. (2020) · Primary care diabetes · doi:10.1016/j.pcd.2020.10.013 · Cited by 25
Chinese clinical guidelines for continuous glucose monitoring (2018 edition)
Bao, Y., Chen, L., Chen, L., Dou, J., Gao, Z., Gao, L., Guo, L., Guo, X., Ji, L., Ji, Q., et al. (2019) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3152 · Cited by 23
“Therefore, standardization of CGM reports is extremely important.(114) Currently, CGM monitoring reports generally include three parts: (a) general items: basic information about the subject, clinical diagnosis, inspection date, medical staff signature and date; (b) CGM data; and (c) clinical implications of the resul…”
BackgroundFloch, J. P. L., & Kessler, L. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816632003 · Cited by 23
“However, indices of glucose variability could be especially useful to analyze ambulatory glucose profiles and optimize decision making in diabetes.(16) For the clinician, it is important to get simple indices, poorly dependent of the mean glucose value commonly estimated with HbA1c and associated with glucose fluctuat…”
BackgroundJoubert, M., Baillot-Rudoni, S., Catargi, B., Charpentier, G., Esvant, A., Franc, S., Guerci, B., Guilhem, I., Melki, V., Merlen, E., et al. (2015) · Diabetes & Metabolism · doi:10.1016/j.diabet.2015.07.001 · Cited by 22
Recommendations for self-monitoring in pediatric diabetes: a consensus statement by the ISPED
Diabetes Study Group of the Italian Society for Pediatric Endocrinology and Diabetology, Scaramuzza, A. E., Cherubini, V., Tumini, S., Bonfanti, R., Buono, P., Cardella, F., d’Annunzio, G., Frongia, A. P., Lombardo, F., et al. (2013) · Acta Diabetologica · doi:10.1007/s00592-013-0521-7 · Cited by 22
“It is our belief that the National Health Service should provide all necessary resources to provide SMBG and possibly CGM to all children and adolescents with type 1 diabetes, according to the standards of care provided by these recommendations [1] and internationally [14, 17, 18, 71–74].”
Method
Metadata
- Authors
- Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., Hirsch, I. B., Klonoff, D. C., Kruger, D. F., Matfin, G., Mazze, R. S., Olson, B. A., Parkin, C., Peters, A., Powers, M. A., Rodriguez, H., Southerland, P., Strock, E. S., Tamborlane, W., & Wesley, D. M.
- Affiliations
- Park Nicollet Clinic (US)
- Oregon Health & Science University (US)
- University of California San Diego (US)
- Jaeb Center for Health Research (US)
- Lucile Packard Children's Hospital (US)
- Florida State University (US)
- Lantana Consulting Group
- University of Colorado Denver (US)
- Columbia University Irving Medical Center (US)
- University of Washington (US)
- University of California, San Francisco (US)
- Henry Ford Health (US)
- CGParkin Communications, Inc.
- University of Southern California (US)
- University of South Florida (US)
- Team Type 1, Atlanta, Georiga.
- Yale University (US)
- Corresponding author
- Bergenstal, Richard M.
- ORCID
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2013-03
- Volume
- 15
- Issue
- 3
- Pages
- 198-211
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2388765709
- Cited by
- 307
- References
- 55
- Citations by year
- 2026: 17 · 2025: 13 · 2024: 14 · 2023: 21 · 2022: 24 · 2021: 25 · 2020: 26 · 2019: 31 · 2018: 31 · 2017: 33 · 2016: 22 · 2015: 20 · 2014: 16 · 2013: 14
- Type
- conference abstract
- Language
- en
- Open access
- closed
- Locations
- Diabetes Technology & Therapeutics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Leona M. and Harry B. Helmsley Charitable Trust
- U.S. Food and Drug Administration
- Abbott Diabetes Care
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- ambulatory glucose profile, continuous glucose monitoring, type 1 diabetes, glycemic control, clinical decision-making, expert panel recommendations
- MeSH terms
- Blood Glucose, Decision Making, Diabetes Mellitus, Female, Humans, Hyperglycemia, Hypoglycemia, Male, Reference Standards, Software, United States, Blood Glucose Self-Monitoring, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review