CoChat

From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior

Acciaroli, Giada, Vettoretti, Martina, Facchinetti, Andrea, Sparacino, Giovanni, Cobelli, Claudio · 2016 · Diabetes Technology & Therapeutics
Cited by 22

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: In the DexCom G4 Platinum (DG4P) continuous glucose monitoring (CGM) sensor, the raw current signal generated by glucose-oxidase is transformed to glucose concentration by a calibration function whose parameters are periodically updated by matching self-monitoring of blood glucose references, usually twice a day, to compensate for sensor variability in time. The aim of this work is to reduce DG4P calibration frequency to once a day by a recently proposed Bayesian calibration algorithm, which employs a time-varying calibration function and suitable day-specific priors. METHODS: The database consists of 57 CGM signals that are collected by the DG4P for 7 days. The Bayesian calibration algorithm is used to calibrate the raw current signal following two different schedules, that is, two and one calibration per day. Calibrated glycemic profiles are compared with those originally acquired by the manufacturer, on days 1, 4, and 7, where frequent blood glucose references were available, by using standard metrics, that is, mean absolute relative difference (MARD), percentage of accurate glucose estimates, and percentage of data in the A-zone of Clarke Error Grid. RESULTS: The one per day Bayesian calibration algorithm has accuracy similar to that of two per day (11.8% vs. 11.7% MARD, respectively), and it is statistically better (P-value of 0.0411) than the manufacturer calibration algorithm, which requires two calibrations per day (13.1% MARD). CONCLUSIONS: A Bayesian calibration algorithm employing a time-varying calibration function and suitable priors enables a reduction of the calibrations of DG4P sensor from two to one per day.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2016.0088

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Acciaroli, G., Vettoretti, M., Facchinetti, A., Sparacino, G., & Cobelli, C.
Venue
Diabetes Technology & Therapeutics
Published
2016-08
Volume
18
Issue
8
Pages
472-479
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2516748201
Cited by
22
References
3
FWCI
4.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.