Evaluation of a Predictive Low-Glucose Management System In-Clinic
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: 640G combined insulin pump and CGM system. This study assessed the safety and performance characteristics of the system in an in-clinic setting at eight sites. MATERIALS AND METHODS: In-clinic standardized increases in basal insulin delivery rates were used to induce nocturnal hypoglycemia in subjects (14-75 years) with type 1 diabetes wearing the MiniMed 640G system. The "suspend before low" feature was set at 65 mg/dL, and as a result, the predictive algorithm suspended insulin delivery when the forecasted glucose was predicted to be ≤85 mg/dL in 30 min (a 20 mg/dL safety buffer). Reference plasma glucose values (Yellow Springs Instruments [YSI], Yellow Springs, OH) were used to establish hypoglycemia and were defined as ≥2 consecutive values ≤65 mg/dL. RESULTS: Eighty subjects were screened. Among the 69 successful completers, 27 experienced a hypoglycemic event and 42 did not, a prevention rate of 60%. The mean (±standard deviation) YSI value at the time of pump suspension was 101 ± 18.5 mg/dL, and the mean duration of the 68 "suspend before low" events was 105 ± 27 min. At 120 min after the start of the pump suspension events, the mean YSI value was 102 ± 34.6 mg/dL. CONCLUSION: The MiniMed 640G "suspend before low" feature prevented 60% of induced predicted hypoglycemic events without significant rebound hyperglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652 · cited 2×
“7,8 As demonstrated in several in-clinic and at-home studies, algorithms that suspend insulin delivery in anticipation of hypoglycemia prevent many hypoglycemic episodes that might have otherwise occurred.”
Self-citationHome Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450
Fear of hypoglycaemia in parents of young children with type 1 diabetes: A systematic review
Barnard, K., Thomas, S., Royle, P., Noyes, K., & Waugh, N. (2010) · BMC Pediatrics · doi:10.1186/1471-2431-10-50 · Cited by 239
Tanenberg, R. J., Newton, C. A., & Drake, A. J. (2010) · Endocrine Practice · doi:10.4158/ep09260.cr · Cited by 225
Fanelli, C., Pampanelli, S., Epifano, L., Rambotti, A. M., Ciofetta, M., Modarelli, F., Di Vincenzo, A., Annibale, B., Lepore, M., Lalli, C., et al. (1994) · Diabetologia · doi:10.1007/bf00404337 · Cited by 193
Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia
Choudhary, P., Shin, J., Wang, Y., Evans, M. L., Hammond, P. J., Kerr, D., Shaw, J. A. M., Pickup, J. C., & Amiel, S. A. (2011) · Diabetes Care · doi:10.2337/dc10-2411 · Cited by 175
Prevention of Nocturnal Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B., Chase, H. P., Dassau, E., Cobry, E., Clinton, P., Gage, V., Caswell, K., Wilkinson, J., Cameron, F., Lee, H., et al. (2010) · Diabetes Care · doi:10.2337/dc09-2303 · Cited by 169 · cited 3×
“9 The increases in basal rate insulin may not be typical in a home environment, but algorithms which prevent hypoglycemia under the conditions created in the research center have translated into clinically effective algorithms for preventing nocturnal hypoglycemia in the home environment…”
Self-citationGarg, S., Brazg, R. L., Bailey, T. S., Buckingham, B. A., Slover, R. H., Klonoff, D. C., Shin, J., Welsh, J. B., & Kaufman, F. R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0292 · Cited by 138 · cited 1×
“6,7 17–19 Other factors that could potentially influence the efficacy of a predictive low-glucose suspend system have been evaluated.”
Self-citationChoudhary, P., Olsen, B. S., Conget, I., Welsh, J. B., Vorrink, L., & Shin, J. J. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0324 · Cited by 118 · cited 1×
“Choudhary et al. 15 found that the algorithm prevented 83.1% of hypoglycemic events and that participants felt con-fident using the system and wished to continue using it.”
Influential
Cited by
Chiang, J. L., Maahs, D. M., Garvey, K. C., Hood, K. K., Laffel, L. M., Weinzimer, S. A., Wolfsdorf, J. I., & Schatz, D. (2018) · Diabetes Care · doi:10.2337/dci18-0023 · Cited by 509
Self-citationCappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
14. Children and Adolescents: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s014 · Cited by 367
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Self-citation
Metadata
- Authors
- Buckingham, B. A., Bailey, T. S., Christiansen, M., Garg, S., Weinzimer, S., Bode, B., Anderson, S. M., Brazg, R., Ly, T. T., & Kaufman, F. R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2017-05
- Volume
- 19
- Issue
- 5
- Pages
- 288-292
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2610421233
- Cited by
- 52
- References
- 9
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a Predictive Low-Glucose Management System In-Clinic. https://app.cochat.ai/papers/10.1089/dia.2016.0319
- The paper
- Buckingham, B. A., Bailey, T. S., Christiansen, M., Garg, S., Weinzimer, S., Bode, B., Anderson, S. M., Brazg, R., Ly, T. T., & Kaufman, F. R. (2017). Evaluation of a Predictive Low-Glucose Management System In-Clinic. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2016.0319
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.