The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Crosslinking and Mechanical Properties Significantly Influence Cell Attachment, Proliferation, and Migration Within Collagen Glycosaminoglycan Scaffolds
Open accessAbstract
Crosslinking and the resultant changes in mechanical properties have been shown to influence cellular activity within collagen biomaterials. With this in mind, we sought to determine the effects of crosslinking on both the compressive modulus of collagen-glycosaminoglycan scaffolds and the activity of osteoblasts seeded within them. Dehydrothermal, 1-ethyl-3-3-dimethyl aminopropyl carbodiimide and glutaraldehyde crosslinking treatments were first investigated for their effect on the compressive modulus of the scaffolds. After this, the most promising treatments were used to study the effects of crosslinking on cellular attachment, proliferation, and infiltration. Our experiments have demonstrated that a wide range of scaffold compressive moduli can be attained by varying the parameters of the crosslinking treatments. 1-Ethyl-3-3-dimethyl aminopropyl carbodiimide and glutaraldehyde treatments produced the stiffest scaffolds (fourfold increase when compared to dehydrothermal crosslinking). When cells were seeded onto the scaffolds, the stiffest scaffolds also showed increased cell number and enhanced cellular distribution when compared to the other groups. Taken together, these results indicate that crosslinking can be used to produce collagen-glycosaminoglycan scaffolds with a range of compressive moduli, and that increased stiffness enhances cellular activity within the scaffolds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion
Yeung, T., Georges, P. C., Flanagan, L. A., Marg, B., Ortiz, M., Funaki, M., Zahir, N., Ming, W., Weaver, V., & Janmey, P. A. (2005) · Cell Motility and the Cytoskeleton · doi:10.1002/cm.20041 · Cited by 2,325
Murphy, C. M., Haugh, M. G., & O'Brien, F. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.063 · Cited by 2,056
Self-citationTENSEGRITY: THE ARCHITECTURAL BASIS OF CELLULAR MECHANOTRANSDUCTION
Ingber, D. E. (1997) · Annual Review of Physiology · doi:10.1146/annurev.physiol.59.1.575 · Cited by 1,566
Fluorometric assay of DNA in cartilage explants using Hoechst 33258
Kim, Y.-J., Sah, R. L. Y., Doong, J.-Y. H., & Grodzinsky, A. J. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90532-5 · Cited by 1,357
The effect of pore size on cell adhesion in collagen-GAG scaffolds
O’Brien, F. J., Harley, B. A., Yannas, I. V., & Gibson, L. J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.052 · Cited by 1,329
Self-citationBURKE, J. F., YANNAS, I. V., QUINBY, W. C., BONDOC, C. C., & JUNG, W. K. (1981) · Annals of Surgery · doi:10.1097/00000658-198110000-00005 · Cited by 1,250
Substrate Compliance versus Ligand Density in Cell on Gel Responses
Engler, A., Bacakova, L., Newman, C., Hategan, A., Griffin, M., & Discher, D. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74140-5 · Cited by 1,141
Design of an artificial skin. I. Basic design principles
Yannas, I. V., & Burke, J. F. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140108 · Cited by 1,044
Design of an artificial skin. I. Basic design principles
Yannas, I. V., & Burke, J. F. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140314 · Cited by 889
Cited by
Antoine, E. E., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0086 · Cited by 611
3D Cell Culture Systems: Tumor Application, Advantages, and Disadvantages
Habanjar, O., Diab-Assaf, M., Caldefie-Chezet, F., & Delort, L. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222212200 · Cited by 547
Fernandez-Yague, M. A., Abbah, S. A., McNamara, L., Zeugolis, D. I., Pandit, A., & Biggs, M. J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.09.005 · Cited by 523
Naturally and synthetic smart composite biomaterials for tissue regeneration
Pérez, R. A., Won, J.-E., Knowles, J. C., & Kim, H.-W. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.03.009 · Cited by 380
Cell-scaffold interactions in the bone tissue engineering triad
Orthopaedic Research and Biotechnology, R. B., Murphy, C., O’Brien, F., Little, D., & Schindeler, A. (2013) · European Cells and Materials · doi:10.22203/ecm.v026a09 · Cited by 312
Self-citationA biomimetic multi-layered collagen-based scaffold for osteochondral repair
Levingstone, T. J., Matsiko, A., Dickson, G. R., O’Brien, F. J., & Gleeson, J. P. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.01.005 · Cited by 290
Self-citationMurphy, C. M., Matsiko, A., Haugh, M. G., Gleeson, J. P., & O’Brien, F. J. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2011.11.009 · Cited by 262
Self-citationMatsiko, A., Gleeson, J. P., & O'Brien, F. J. (2015) · Tissue Engineering Part A · doi:10.1089/ten.tea.2013.0545 · Cited by 259
Self-citationCollagen–Alginate Composite Hydrogel: Application in Tissue Engineering and Biomedical Sciences
Hu, T., & Lo, A. C. Y. (2021) · Polymers · doi:10.3390/polym13111852 · Cited by 155
Cunniffe, G. M., Curtin, C. M., Thompson, E. M., Dickson, G. R., & O’Brien, F. J. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b06596 · Cited by 95
Self-citationAssessment of the biocompatibility and stability of a gold nanoparticle collagen bioscaffold
Grant, S. A., Spradling, C. S., Grant, D. N., Fox, D. B., Jimenez, L., Grant, D. A., & Rone, R. J. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34698 · Cited by 81
Gao, S., Yuan, Z., Guo, W., Chen, M., Liu, S., Xi, T., & Guo, Q. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.10.074 · Cited by 72
Levine, A. C., Heberlig, G. W., & Nomura, C. T. (2016) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2015.11.048 · Cited by 49
Levine, A. C., Sparano, A., Twigg, F. F., Numata, K., & Nomura, C. T. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00052 · Cited by 48
Saleh, T., Ahmed, E., Yu, L., Hussein, K., Park, K.-M., Lee, Y.-S., Kang, B.-J., Choi, K.-Y., Choi, S., Kang, K.-S., et al. (2018) · Artificial Cells, Nanomedicine, and Biotechnology · doi:10.1080/21691401.2018.1457037 · Cited by 41
Aslan, B., Guler, S., Tevlek, A., & Aydin, H. M. (2018) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.34022 · Cited by 40
Zhong, Y., Jiang, A., Sun, F., Xiao, Y., Gu, Y., Wu, L., Zhang, Y., & Shi, H. (2019) · Tissue Engineering and Regenerative Medicine · doi:10.1007/s13770-018-0170-6 · Cited by 22
Metadata
- Authors
- Haugh, M. G., Murphy, C. M., McKiernan, R. C., Altenbuchner, C., & O'Brien, F. J.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2011-05
- Volume
- 17
- Issue
- 9-10
- Pages
- 1201-1208
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W2127471027
- Cited by
- 330
- References
- 40
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.