Automated quantification of coronary plaque with computed tomography: comparison with intravascular ultrasound using a dedicated registration algorithm for fusion-based quantification
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
AIMS: Previous studies have used semi-automated approaches for coronary plaque quantification on multi-detector row computed tomography (CT), while an automated quantitative approach using a dedicated registration algorithm is currently lacking. Accordingly, the study aimed to demonstrate the feasibility and accuracy of automated coronary plaque quantification on cardiac CT using dedicated software with a novel 3D coregistration algorithm of CT and intravascular ultrasound (IVUS) data sets. METHODS AND RESULTS: Patients who had undergone CT and IVUS were enrolled. Automated lumen and vessel wall contour detection was performed for both imaging modalities. Dedicated automated quantitative software (QCT) with a unique registration algorithm was used to fuse a complete IVUS run with a CT angiography volume using true anatomical markers. At the level of the minimal lumen area (MLA), percentage lumen area stenosis, plaque burden, and degree of remodelling were obtained on CT. Additionally, mean plaque burden was assessed for the whole coronary plaque. At the identical level within the coronary artery, the same variables were derived from IVUS. Fifty-one patients (40 men, 58 ± 11 years, 103 coronary arteries) with 146 lesions were evaluated. Quantitative computed tomography and IVUS showed good correlation for MLA (n = 146, r = 0.75, P < 0.001). At the level of the MLA, both techniques were well-correlated for lumen area stenosis (n = 146, r = 0.79, P < 0.001) and plaque burden (n = 146, r = 0.70, P < 0.001). Mean plaque burden (n = 146, r = 0.64, P < 0.001) and remodelling index (n = 146, r = 0.56, P < 0.001) showed significant correlations between QCT and IVUS. CONCLUSION: Automated quantification of coronary plaque on CT is feasible using dedicated quantitative software with a novel 3D registration algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786 · cited 1×
“The non-enhanced scans were used to assess the total amount of coronary calcium according to the Agatston approach.(13) Computed tomography angiography data sets were evaluated by an independent and experienced observer, who was blinded to the IVUS data.”
MethodPathology of the Vulnerable Plaque
Virmani, R., Burke, A. P., Farb, A., & Kolodgie, F. D. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.065 · Cited by 2,315
Mintz, G. S., Nissen, S. E., Anderson, W. D., Bailey, S. R., Erbel, R., Fitzgerald, P. J., Pinto, F. J., Rosenfield, K., Siegel, R. J., Tuzcu, E. M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01175-5 · Cited by 2,185
Diagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
Self-citationScanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00126-6 · Cited by 1,123
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109 · cited 4×
“8,18,20,21 Leber et al. 8 evaluated the performance of cardiac CT for quantification of coronary lesions in 55 patients with stable CAD, of whom 18 patients underwent IVUS.”
MethodInfluentialMultislice Computed Tomographic Characteristics of Coronary Lesions in Acute Coronary Syndromes
Motoyama, S., Kondo, T., Sarai, M., Sugiura, A., Harigaya, H., Sato, T., Inoue, K., Okumura, M., Ishii, J., Anno, H., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.03.044 · Cited by 1,026 · cited 1×
“This is an important finding as outward remodelling of coronary lesions, which is commonly referred to as positive remodelling, represents one of the plaque characteristics that has been associated with an increased risk for plaque rupture and acute coronary syndromes.(5,24) Finally, although QCT was reproducible for…”
BackgroundSchoenhagen, P., Ziada, K. M., Kapadia, S. R., Crowe, T. D., Nissen, S. E., & Tuzcu, E. M. (2000) · Circulation · doi:10.1161/01.cir.101.6.598 · Cited by 753
Leber, A. W., Becker, A., Knez, A., von Ziegler, F., Sirol, M., Nikolaou, K., Ohnesorge, B., Fayad, Z. A., Becker, C. R., Reiser, M., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.058 · Cited by 711 · cited 13×
“Furthermore, Bland–Altman analysis showed an underestimation of MLA (and overestimation of lumen area stenosis) as assessed with QCT when compared with IVUS.”
BackgroundResultInfluentialNoninvasive Coronary Angiography With Multislice Computed Tomography
Hoffmann, M. H. K. (2005) · JAMA · doi:10.1001/jama.293.20.2471 · Cited by 507
Cited by
Coronary Atherosclerotic Precursors of Acute Coronary Syndromes
Chang, H.-J., Lin, F. Y., Lee, S.-E., Andreini, D., Bax, J., Cademartiri, F., Chinnaiyan, K., Chow, B. J. W., Conte, E., Cury, R. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.02.079 · Cited by 494
Self-citationThe Myth of the “Vulnerable Plaque”
Arbab-Zadeh, A., & Fuster, V. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.11.041 · Cited by 434
Comprehensive plaque assessment by coronary CT angiography
Maurovich-Horvat, P., Ferencik, M., Voros, S., Merkely, B., & Hoffmann, U. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.60 · Cited by 381
Testosterone Treatment and Coronary Artery Plaque Volume in Older Men With Low Testosterone
Budoff, M. J., Ellenberg, S. S., Lewis, C. E., Mohler, E. R., Wenger, N. K., Bhasin, S., Barrett-Connor, E., Swerdloff, R. S., Stephens-Shields, A., Cauley, J. A., et al. (2017) · JAMA · doi:10.1001/jama.2016.21043 · Cited by 376
2020 Clinical practice guidelines for Stable coronary artery disease
Russian Society of Cardiology (RSC) (2020) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2020-4076 · Cited by 242
“Критерием АСБ является локальное утолщение комплекса интима-медия (КИМ) ≥1,5 мм или толщина КИМ, на 50% или 0,5 мм превышающая толщину КИМ рядом расположенных участков сонной артерии [34, 35].”
de Graaf, M. A., Broersen, A., Kitslaar, P. H., Roos, C. J., Dijkstra, J., Lelieveldt, B. P. F., Jukema, J. W., Schalij, M. J., Delgado, V., Bax, J. J., et al. (2013) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-013-0194-x · Cited by 238
Self-citationLo, J., Lu, M. T., Ihenachor, E. J., Wei, J., Looby, S. E., Fitch, K. V., Oh, J., Zimmerman, C. O., Hwang, J., Abbara, S., et al. (2015) · The Lancet HIV · doi:10.1016/s2352-3018(14)00032-0 · Cited by 236
Kirişli, H. A., Schaap, M., Metz, C. T., Dharampal, A. S., Meijboom, W. B., Papadopoulou, S. L., Dedic, A., Nieman, K., de Graaf, M. A., Meijs, M. F. L., et al. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.007 · Cited by 205
“Second, lumen and vessel wall contours are detected in each vessel (running from the ostia to the most distal point)(Boogers et al., 2012).”
BackgroundSelf-citationMastrodicasa, D., van Assen, M., Huisman, M., Leiner, T., Williamson, E. E., Nicol, E. D., Allen, B. D., Saba, L., Vliegenthart, R., & Hanneman, K. (2025) · Radiology · doi:10.1148/radiol.240516 · Cited by 69
Metadata
- Authors
- Boogers, M. J., Broersen, A., van Velzen, J. E., de Graaf, F. R., El-Naggar, H. M., Kitslaar, P. H., Dijkstra, J., Delgado, V., Boersma, E., de Roos, A., Schuijf, J. D., Schalij, M. J., Reiber, J. H. C., Bax, J. J., & Jukema, J. W.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-01-26
- Volume
- 33
- Issue
- 8
- Pages
- 1007-1016
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2161351985
- Cited by
- 233
- References
- 18
- FWCI
- 14.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.