Cardiac resynchronization therapy: state of the art 2013
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Cardiac resynchronization therapy (CRT) is currently an established device therapy for heart failure (HF) patients. Cumulated knowledge on the pathophysiological mechanisms, implantation techniques, advancement of device-based technologies, and clinical trial experience has impacted on this evolving therapy significantly in the last few years. This article will address the updated CRT guideline and potentially new indications of CRT such as patients with New York Heart Association Class I, normal QRS duration, and non-HF patients with pacing indications. Furthermore, important but unresolved issues will also be discussed which include the impact of QRS morphology and QRS duration on CRT response, new approaches for placement of left ventricular (LV) lead, multisite LV pacing, and the role of HF disease monitoring program.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Existing CRTs rely on the use of multiple intracardiac leads to pace both ventricles in a synchronized sequence12.”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [12]
Citations
Cites
ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012
Authors/Task Force Members, McMurray, J. J. V., Adamopoulos, S., Anker, S. D., Auricchio, A., Böhm, M., Dickstein, K., Falk, V., Filippatos, G., Fonseca, C., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs104 · Cited by 6,879
Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events
Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., Estes, N. A. M., Foster, E., Greenberg, H., Higgins, S. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0906431 · Cited by 3,157 · cited 1×
“Class III to ambulatory Class IV, outcomes from REVERSE, MADIT-CRT, and RAFT support more restrictive selection for Class II patients based on the observation that CRT only benefit patients with QRS duration ≥150 ms, but not those ,150 ms.(5,30) Although guidelines may appropriately allow a more generous range for QRS…”
MethodACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Self-citationThe DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Cardiac-Resynchronization Therapy for Mild-to-Moderate Heart Failure
Tang, A. S. L., Wells, G. A., Talajic, M., Arnold, M. O., Sheldon, R., Connolly, S., Hohnloser, S. H., Nichol, G., Birnie, D. H., Sapp, J. L., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1009540 · Cited by 1,859 · cited 3×
“Class III to ambulatory Class IV, outcomes from REVERSE, MADIT-CRT, and RAFT support more restrictive selection for Class II patients based on the observation that CRT only benefit patients with QRS duration ≥150 ms, but not those ,150 ms.(5,30) Although guidelines may appropriately allow a more generous range for QRS…”
MethodSweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000072769.17295.b1 · Cited by 1,773
Linde, C., Abraham, W. T., Gold, M. R., St. John Sutton, M., Ghio, S., & Daubert, C. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.027 · Cited by 1,261
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 902
Zareba, W., Klein, H., Cygankiewicz, I., Hall, W. J., McNitt, S., Brown, M., Cannom, D., Daubert, J. P., Eldar, M., Gold, M. R., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.960898 · Cited by 839
Cardiac-Resynchronization Therapy in Heart Failure with Narrow QRS Complexes
Beshai, J. F., Grimm, R. A., Nagueh, S. F., Baker, J. H., Beau, S. L., Greenberg, S. M., Pires, L. A., & Tchou, P. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa0706695 · Cited by 795
Bleeker, G. B., Kaandorp, T. A. M., Lamb, H. J., Boersma, E., Steendijk, P., de Roos, A., van der Wall, E. E., Schalij, M. J., & Bax, J. J. (2006) · Circulation · doi:10.1161/circulationaha.105.543678 · Cited by 760
Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy
Khan, F. Z., Virdee, M. S., Palmer, C. R., Pugh, P. J., O'Halloran, D., Elsik, M., Read, P. A., Begley, D., Fynn, S. P., & Dutka, D. P. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.030 · Cited by 647
Yu, C.-M., Lin, H., Zhang, Q., & Sanderson, J. E. (2003) · Heart · doi:10.1136/heart.89.1.54 · Cited by 618
Self-citationLeft Ventricular‐Based Cardiac Stimulation Post AV Nodal Ablation Evaluation (The PAVE Study)
DOSHI, R. N., DAOUD, E. G., FELLOWS, C., TURK, K., DURAN, A., HAMDAN, M. H., PIRES, L. A., & for the PAVE Study Group (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50062.x · Cited by 597
2010 Focused Update of ESC Guidelines on device therapy in heart failure
Authors/Task Force Members, Dickstein, K., Vardas, P. E., Auricchio, A., Daubert, J.-C., Linde, C., McMurray, J., Ponikowski, P., Priori, S. G., Sutton, R., et al. (2010) · EP Europace · doi:10.1093/europace/euq392 · Cited by 593
Singh, J. P., Klein, H. U., Huang, D. T., Reek, S., Kuniss, M., Quesada, A., Barsheshet, A., Cannom, D., Goldenberg, I., McNitt, S., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.000646 · Cited by 591
The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526
Minimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node Disease
Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D., Sheldon, T., & Lamas, G. A. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071880 · Cited by 520
Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515 · cited 1×
“For example, data from LATITUDE and CARELINK RM networks have demonstrated long-term survival benefits of RM as well as insights into clinical management of patients with implanted cardiac devices.(57) A recent study of 377 patients with CRT-D devices capable of daily transmission of their diagnostic data evaluated an…”
MethodSelf-citationMullens, W., Grimm, R. A., Verga, T., Dresing, T., Starling, R. C., Wilkoff, B. L., & Tang, W. H. W. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.11.024 · Cited by 479
Biventricular Pacing in Patients with Bradycardia and Normal Ejection Fraction
Yu, C.-M., Chan, J. Y.-S., Zhang, Q., Omar, R., Yip, G. W.-K., Hussin, A., Fang, F., Lam, K. H., Chan, H. C.-K., & Fung, J. W.-H. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0907555 · Cited by 477 · cited 1×
“7%), receiving pacing for bradycardia indications which showed that biventricular pacing compared with RVA pacing could prevent adverse LV remodelling and reduction in EF at 12 and 24 months.(22,23) However, the remodelling effects of conventional pacing vs.”
BackgroundSelf-citationAuthors/Task Force Members, Dickstein, K., Vardas, P. E., Auricchio, A., Daubert, J.-C., Linde, C., McMurray, J., Ponikowski, P., Priori, S. G., Sutton, R., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq337 · Cited by 445
White, J. A., Yee, R., Yuan, X., Krahn, A., Skanes, A., Parker, M., Klein, G., & Drangova, M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.046 · Cited by 386
Ypenburg, C., van Bommel, R. J., Delgado, V., Mollema, S. A., Bleeker, G. B., Boersma, E., Schalij, M. J., & Bax, J. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.06.046 · Cited by 379
Daubert, C., Gold, M. R., Abraham, W. T., Ghio, S., Hassager, C., Goode, G., Szili-Török, T., & Linde, C. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.011 · Cited by 367
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · Europace · doi:10.1093/europace/eum189 · Cited by 291
Ypenburg, C., Roes, S. D., Bleeker, G. B., Kaandorp, T. A. M., de Roos, A., Schalij, M. J., van der Wall, E. E., & Bax, J. J. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.09.115 · Cited by 281
Yu, C.-M., Chan, Y.-S., Zhang, Q., Yip, G. W. K., Chan, C.-K., Kum, L. C. C., Wu, L., Lee, A. P.-W., Lam, Y.-Y., & Fung, J. W.-H. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.054 · Cited by 273
Self-citationCardiac Resynchronization Therapy in Patients With a Narrow QRS Complex
Bleeker, G. B., Holman, E. R., Steendijk, P., Boersma, E., van der Wall, E. E., Schalij, M. J., & Bax, J. J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.067 · Cited by 260
Adelstein, E. C., & Saba, S. (2007) · American Heart Journal · doi:10.1016/j.ahj.2006.10.015 · Cited by 250
Leclercq, C., Gadler, F., Kranig, W., Ellery, S., Gras, D., Lazarus, A., Clémenty, J., Boulogne, E., & Daubert, J.-C. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.11.074 · Cited by 226
Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted Pacemakers
Crossley, G. H., Chen, J., Choucair, W., Cohen, T. J., Gohn, D. C., Johnson, W. B., Kennedy, E. E., Mongeon, L. R., Serwer, G. A., Qiao, H., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.001 · Cited by 202
FANTONI, C., KAWABATA, M., MASSARO, R., REGOLI, F., RAFFA, S., ARORA, V., SALERNO‐URIARTE, J. A., KLEIN, H. U., & AURICCHIO, A. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2005.40777.x · Cited by 191
Spragg, D. D., Dong, J., Fetics, B. J., Helm, R., Marine, J. E., Cheng, A., Henrikson, C. A., Kass, D. A., & Berger, R. D. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.014 · Cited by 191
Raatikainen, M. J. P., Uusimaa, P., van Ginneken, M. M. E., Janssen, J. P. G., & Linnaluoto, M. (2008) · Europace · doi:10.1093/europace/eun203 · Cited by 189 · cited 1×
“Multiple studies have shown that both patients and caregivers are satisfied with RM both in terms of its ease of use and remaining connected to the follow-up center.(53) In some”
BackgroundMurphy, R. T., Sigurdsson, G., Mulamalla, S., Agler, D., Popovic, Z. B., Starling, R. C., Wilkoff, B. L., Thomas, J. D., & Grimm, R. A. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.12.054 · Cited by 188
Variable Patterns of Septal Activation in Patients with Left Bundle Branch Block and Heart Failure
RODRIGUEZ, L., TIMMERMANS, C., NABAR, A., BEATTY, G., & WELLENS, H. J. J. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.02421.x · Cited by 172
Tops, L. F., Suffoletto, M. S., Bleeker, G. B., Boersma, E., van der Wall, E. E., Gorcsan, J., Schalij, M. J., & Bax, J. J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.011 · Cited by 170
Varma, N., Michalski, J., Epstein, A. E., & Schweikert, R. (2010) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.110.951962 · Cited by 162
Chan, J. Y.-S., Fang, F., Zhang, Q., Fung, J. W.-H., Razali, O., Azlan, H., Lam, K.-H., Chan, H. C.-K., & Yu, C. M. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr336 · Cited by 145
Self-citationFUNCK, R. C., Blanc, J., Mueller, H.-H., Schade‐Brittinger, C., Bailleul, C., & Maisch, B. (2006) · EP Europace · doi:10.1093/europace/eul075 · Cited by 128
Egoavil, C. A., Ho, R. T., Greenspon, A. J., & Pavri, B. B. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.03.012 · Cited by 118
The Benefit of Cardiac Resynchronization Therapy and QRS Duration: A Meta‐Analysis
Stavrakis, S., Lazzara, R., & Thadani, U. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02144.x · Cited by 117
Ungar, A., Del Rosso, A., Giada, F., Bartoletti, A., Furlan, R., Quartieri, F., Lagi, A., Morrione, A., Mussi, C., Lunati, M., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq017 · Cited by 115
Adelstein, E. C., & Saba, S. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.08.069 · Cited by 110 · cited 2×
“On the other hand, patients with right bundle branch block (RBBB) might have minimal electrical or electromechanical delay in the LV unless left fascicular hemiblock is present.25 In addition, patients with intraventricular delay (IVCD) or incomplete BBB which typically have a QRS duration between 120 and 150 ms will…”
MethodEchocardiography, dyssynchrony, and the response to cardiac resynchronization therapy
Yu, C., Sanderson, J. E., & Gorcsan, J. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq263 · Cited by 92
Self-citationLeft Ventricular Endocardial Stimulation for Severe Heart Failure
Bordachar, P., Derval, N., Ploux, S., Garrigue, S., Ritter, P., Haı̈ssaguerre, M., & Jaı̈s, P. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.038 · Cited by 80
YU, C., FUNG, J. W., CHAN, C., CHAN, Y., ZHANG, Q., LIN, H., YIP, G. W. K., KUM, L. C. C., KONG, S., ZHANG, Y., et al. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03648.x · Cited by 79
Self-citationCritical appraisal of methods to assess mechanical dyssynchrony
Yu, C., Bax, J. J., & Gorcsan, J. (2008) · Current Opinion in Cardiology · doi:10.1097/hco.0b013e32831bc34e · Cited by 74
Self-citationLenarczyk, R., Kowalski, O., Kukulski, T., Pruszkowska‐Skrzep, P., Sokal, A., Szulik, M., Zielińska, T., Kowalczyk, J. P., Pluta, S., Średniawa, B., et al. (2008) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.12.009 · Cited by 73
Sack, S., Wende, C. M., Nägele, H., Katz, A., Bauer, W. R., Barr, C. S., MALINOWSKI, K., Schwacke, H., Leyva, F., Proff, J., et al. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr089 · Cited by 59
Haghjoo, M., Bagherzadeh, A., Farahani, M. M., Haghighi, Z. O., & Sadr‐Ameli, M. A. (2008) · EP Europace · doi:10.1093/europace/eun081 · Cited by 56
Clinical and echocardiographic predictors of nonresponse to cardiac resynchronization therapy
Shanks, M., Delgado, V., Ng, A. C. T., Auger, D., Mooyaart, E. A. Q., Bertini, M., Marsan, N. A., van Bommel, R. J., Holman, E. R., Poldermans, D., et al. (2011) · American Heart Journal · doi:10.1016/j.ahj.2010.11.011 · Cited by 49
van Gelder, B. M., Houthuizen, P., & Bracke, F. A. L. E. (2011) · EP Europace · doi:10.1093/europace/eur136 · Cited by 46
LEE, K. L., Tse, H., Echt, D. S., & Lau, C. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.02.025 · Cited by 45
Kassai, I., Földesi, C., Székely, A. D., & Szili‐Törok, T. (2008) · EP Europace · doi:10.1093/europace/eun090 · Cited by 35
Lenarczyk, R., Kowalski, O., Średniawa, B., Pruszkowska‐Skrzep, P., Pluta, S., Sokal, A., Kukulski, T., Stabryła-Deska, J., Woźniak, A., Kowalczyk, J. P., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01394.x · Cited by 34
Fung, J. W., Lam, Y., Zhang, Q., Yip, G. W., CHAN, W. W. L., Chan, G. C. P., Chan, J. Y., & Yu, C. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01364.x · Cited by 28
Self-citationZhang, Q., Fang, F., Yip, G. W., Chan, J. Y., Shang, Q., Fung, J. W., Chan, A. K.-Y., Liang, Y.-J., & Yu, C. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.06.027 · Cited by 23
Self-citation
Cited by
Research Advances in Heart Failure: A Compendium
Braunwald, E. (2013) · Circulation Research · doi:10.1161/circresaha.113.302254 · Cited by 85
The interactions between respiratory and cardiovascular systems in systolic heart failure
Cross, T. J., Kim, C., Johnson, B. D., & Lalande, S. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00113.2019 · Cited by 64
Okada, J., Washio, T., Nakagawa, M., WATANABE, M., Kadooka, Y., Kariya, T., Yamashita, H., Yamada, Y., Momomura, S., Nagai, R., et al. (2017) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2017.05.006 · Cited by 55
Lyu, H., John, M., Burkland, D., Greet, B., Post, A., Babakhani, A., & Razavi, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-59017-z · Cited by 51
Heart failure: the cardiovascular epidemic of the 21st century
Lüscher, T. F. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv004 · Cited by 47
Metadata
- Authors
- Yu, C.-M., & Hayes, D. L.
- Affiliations
- Chinese University of Hong Kong (HK)
- Mayo Clinic (US)
- Corresponding author
- Yu, Cheuk-Man
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-01-25
- Volume
- 34
- Issue
- 19
- Pages
- 1396-1403
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2164140331
- Cited by
- 68
- References
- 59
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 3 · 2019: 4 · 2018: 7 · 2017: 6 · 2016: 5 · 2015: 15 · 2014: 11 · 2013: 2
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- cardiac resynchronization therapy, heart failure, CRT indications, QRS duration, QRS morphology, CRT response, left ventricular lead placement, cardiac device therapy
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Electrodes, Heart Failure, Humans, Treatment Failure, Practice Guidelines as Topic, Monitoring, Ambulatory, Prosthesis Implantation, Cardiac Resynchronization Therapy, Cardiac Resynchronization Therapy Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.