Cited by 81ECG Monitoring and AnalysisCardiac electrophysiology and arrhythmiasCardiac pacing and defibrillation studies

Prospective, multicentre validation of a simple, patient-operated electrocardiographic system for the detection of arrhythmias and electrocardiographic changes

Open access
Kaleschke, G., Hoffmann, B., Drewitz, I., Steinbeck, G., Naebauer, M., Goette, A., Breithardt, G., Kirchhof, P.·2009·Europace

Abstract

AIMS: Electrocardiographic changes, e.g. arrhythmias causing syncope or palpitations, are often transient and therefore difficult to diagnose. Systematic and symptom-activated ECG recordings can increase diagnostic yield in such patients. We evaluated the diagnostic accuracy of a simple, leadless, patient-operated ECG device compared with a standard 12-lead ECG. METHODS AND RESULTS: We recorded a standard 12-lead surface ECG and a patient-activated ECG in direct succession in 508 consecutive patients enrolled in four centres. All ECGs were analysed by a single, blinded observer. ECGs were analysable in 505 (99.4%) patients (66% male, age 61 +/- 15 years, and body mass index 27 +/- 4). Analysis of the patient-activated ECG adequately detected a normal ECG (sensitivity 91% and specificity 95%), atrial fibrillation (AF) (sensitivity 99% and specificity 96%), and even T-wave abnormalities (sensitivity 90% and specificity 75%). Diagnostic accuracy for atrioventricular nodal block was moderate (sensitivity 79% and specificity 99%). Continuous parameters correlated well: (r(2) = 0.89 for heart rate, 0.83 for PR interval, 0.78 for QRS duration, and 0.89 for QTc). CONCLUSION: Recordings made by this patient-operated ECG device allow to detect arrhythmias and other ECG changes with high accuracy compared with a standard ECG. It may help to improve accurate diagnosis of transient ECG changes such as paroxysmal AF in palpitations or other unexplained cardiac symptoms.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eup262

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Schuchert A, Behrens G, Meinertz T. Evaluation of infrequent episodes of palpitations with a patient-activated hand-held electrocardiograph. Z Kardiol 2002; 91:62-7.

Cited by

Sorted by citations

Authors
Kaleschke, G., Hoffmann, B., Drewitz, I., Steinbeck, G., Naebauer, M., Goette, A., Breithardt, G., & Kirchhof, P.
Affiliations
  • University Hospital Münster (DE)
  • Universität Hamburg (DE)
  • Ludwig-Maximilians-Universität München (DE)
  • Otto-von-Guericke-Universität Magdeburg (DE)
Corresponding author
Kirchhof, P.
Venue
Europace
Published
2009-09-24
Volume
11
Issue
10
Pages
1362-1368
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2143975628
Cited by
81
References
28
Citations by year
2025: 4 · 2024: 5 · 2023: 6 · 2022: 8 · 2021: 6 · 2020: 4 · 2019: 6 · 2018: 5 · 2017: 7 · 2016: 9 · 2015: 7 · 2014: 5 · 2013: 4 · 2012: 2
FWCI
1.08
Type
journal article
Language
en
Open access
Locations
  • EP Europace (publishedVersion)
  • PubMed (publishedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
Funders
  • Omron Healthcare
  • Kompetenznetz Vorhofflimmern
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
wearable ECG, arrhythmia detection, atrial fibrillation, paroxysmal atrial fibrillation, syncope, palpitations, atrioventricular nodal block, T wave changes, diagnostic accuracy, 12-lead ECG comparison, QTc interval
MeSH terms
Adolescent, Adult, Aged, Aged, 80 and over, Arrhythmias, Cardiac, Electrocardiography, Equipment Design, Female, Germany, Humans, Male, Middle Aged, Self Care, Sensitivity and Specificity, Reproducibility of Results, Electrocardiography, Ambulatory, Telemedicine, Equipment Failure Analysis, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review