Validation and clinical use of a novel diagnostic device for screening of atrial fibrillation
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
AIMS: Patients with asymptomatic and undiagnosed atrial fibrillation (AF) are at increased risk of heart failure and ischaemic stroke. In this study, we validated a new diagnostic device, the MyDiagnostick, for detection of AF by general practitioners and patients. It records and stores a Lead I electrocardiogram (ECG) which is automatically analysed for the presence of AF. METHODS AND RESULTS: In total, 192 patients (age 69.4 ± 12.6 years) were asked to hold the MyDiagnostick for 1 min, immediately before a routine 12-lead ECG was recorded. Atrial fibrillation detection and ECGs stored by the MyDiagnostick were compared with the cardiac rhythm on the 12-lead ECG. In a second part of the study, the MyDiagnostick was used to screen for AF during influenza vaccination in the general practitioner's office. Atrial fibrillation was present in 53 out of the 192 patients (27.6%). All AF patients were correctly detected by the MyDiagnostick (sensitivity 100%; 95% confidence interval 93-100%). MyDiagnostick AF classification in 6 out of 139 patients in sinus rhythm was considered false positive (specificity 95.9%; 95% confidence interval 91.3-98.1%). During 4 h of influenza vaccination in 676 patients (age 74 ± 7.1 years), the MyDiagnostick correctly diagnosed AF in all 55 patients (prevalence 8.1%). In 11 patients (1.6%), AF was not diagnosed before, all with a CHA2DS2VASc score of >1. CONCLUSION: The high AF detection performance of the MyDiagnostick, combined with the ease of use of the device, enables large screening programmes for detection of undiagnosed AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Several patientoperated devices 136,137 and extended continuous ECG monitoring using skin patch recorders 138 have been validated for detection of paroxysmal AF. 139”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [137]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabigatran versus warfarin in patients with atrial fibrillation
Connolly, S. J., Ezekowitz, M. D., Yusuf, S., Eikelboom, J., Oldgren, J., Parekh, A., Pogue, J., Reilly, P. A., Themeles, E., Varrone, J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0905561 · Cited by 11,215
Rivaroxaban versus warfarin in nonvalvular atrial fibrillation
Patel, M. R., Mahaffey, K. W., Garg, J., Pan, G., Singer, D. E., Hacke, W., Breithardt, G., Halperin, J. L., Hankey, G. J., Piccini, J. P., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009638 · Cited by 9,430
Apixaban versus warfarin in patients with atrial fibrillation
Granger, C. B., Alexander, J. H., McMurray, J. J. V., Lopes, R. D., Hylek, E. M., Hanna, M., Al-Khalidi, H. R., Ansell, J., Atar, D., Avezum, A., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1107039 · Cited by 8,943
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,864
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100 · cited 13×
“Another costeffective indication could be outpatient cardiac monitoring for identification of paroxysmal AF in patients after ischaemic stroke.19 The use of the MyDiagnostick in opportunistic screening may also improve the identification of asymptomatic patients with AF.”
BackgroundInfluentialPrevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study
Heeringa, J., van der Kuip, D. A. M., Hofman, A., Kors, J. A., van Herpen, G., Stricker, B. H. C., Stijnen, T., Lip, G. Y. H., & Witteman, J. C. M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi825 · Cited by 1,939 · cited 1×
“8% in those aged ≥85 years.(1) With ageing populations, the prevalence of AF will increase substantially during thenextdecennia.”
BackgroundGuidelines for the management of atrial fibrillation
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · EP Europace · doi:10.1093/europace/euq350 · Cited by 1,747
2012 Focused Update of the ESC Guidelines for the Management of Atrial Fibrillation
Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., & Kirchhof, P. (2013) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2012.11.003 · Cited by 687
Jabaudon, D., Sztajzel, J., Sievert, K., Landis, T., & Sztajzel, R. (2004) · Stroke · doi:10.1161/01.str.0000131269.69502.d9 · Cited by 414
Research works printed but not linked: 5
- 2013, International journal of cardiology, 164, 371, 10.1016/j.ijcard.2012.08.002 · DOI
- 2009, New England Journal of Medicine, 361, 1139, 10.1056/NEJMoa0905561 · DOI · Paper page
- Barth l my, 2003, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc, 8, 194, 10.1046/j.1542-474X.2003.08305.x · DOI · Paper page
- 2013, International journal of cardiology, 165, 193, 10.1016/j.ijcard.2013.01.220 · DOI · Paper page
- 2009, American Journal of Hypertension, 22, 848, 10.1038/ajh.2009.98 · DOI · Paper page
Cited by
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · Europace · doi:10.1093/europace/euw295 · Cited by 6,439
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
“These devices have been widely used for single timepoint AF screening.(37,66,111) Repeated handheld ECG recordings over 14-28 days have diagnostic accuracy equivalent to standard event recorders,(24) superior to 12-lead ECG and 24-hour Holter for paroxysmal AF,(51,112-114) and have been used successfully in large scal…”
MethodSelf-citationStroke prevention in atrial fibrillation
Freedman, B., Potpara, T. S., & Lip, G. Y. H. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31257-0 · Cited by 463
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
Lip, G. Y. H., Fauchier, L., Freedman, S. B., Van Gelder, I., Natale, A., Gianni, C., Nattel, S., Potpara, T., Rienstra, M., Tse, H.-F., et al. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.16 · Cited by 238
Early or Delayed Cardioversion in Recent-Onset Atrial Fibrillation
Pluymaekers, N. A. H. A., Dudink, E. A. M. P., Luermans, J. G. L. M., Meeder, J. G., Lenderink, T., Widdershoven, J., Bucx, J. J. J., Rienstra, M., Kamp, O., Van Opstal, J. M., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1900353 · Cited by 206
Desteghe, L., Raymaekers, Z., Lutin, M., Vijgen, J., Dilling-Boer, D., Koopman, P., Schurmans, J., Vanduynhoven, P., Dendale, P., & Heidbuchel, H. (2016) · Europace · doi:10.1093/europace/euw025 · Cited by 164
“The algorithm of the MyDiagnostick will indicate AF based on an irregular R–R interval which is present during at least 75% of the 1-min recording.(11) The AliveCor is coupled with an iPhone and allows a noise-filtered lead I ECG recording by means of the corresponding AliveECG app.”
MethodResultInfluentialKirchhof, P., Breithardt, G., Bax, J., Benninger, G., Blomstrom-Lundqvist, C., Boriani, G., Brandes, A., Brown, H., Brueckmann, M., Calkins, H., et al. (2016) · Europace · doi:10.1093/europace/euv304 · Cited by 141
Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis
Welton, N. J., McAleenan, A., Thom, H. H., Davies, P., Hollingworth, W., Higgins, J. P., Okoli, G., Sterne, J. A., Feder, G., Eaton, D., et al. (2017) · Health Technology Assessment · doi:10.3310/hta21290 · Cited by 141
Kaasenbrood, F., Hollander, M., Rutten, F. H., Gerhards, L. J., Hoes, A. W., & Tieleman, R. G. (2016) · Europace · doi:10.1093/europace/euv426 · Cited by 119
“In a pilot study, this device seemed feasible as a screening tool during influenza vaccination in primary care.(12)”
BackgroundMethodSelf-citationKotecha, D., BREITHARDT, G. E., Camm, A. J., Lip, G. Y. H., Schotten, U., Ahlsson, A., Arnar, D. O., Atar, D., Auricchio, A., Bax, J. J., et al. (2018) · EP Europace · doi:10.1093/europace/eux318 · Cited by 125
Orchard, J., Lowres, N., Freedman, S. B., Ladak, L., Lee, W., Zwar, N., Peiris, D., Kamaladasa, Y., Li, J., & Neubeck, L. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316670255 · Cited by 100
“A study in The Netherlands found that screening patients aged >65 years for AF during flu vaccination in the general practice setting was promising.(12) In Australia, the annual flu-vaccination programme is well entrenched and has excellent uptake, and is a time when patients are likely to be available and receptive t…”
BackgroundJacobs, M. S., Kaasenbrood, F., Postma, M. J., van Hulst, M., & Tieleman, R. G. (2016) · Europace · doi:10.1093/europace/euw285 · Cited by 97
“The ECG rhythm strip can be visualized and analysed by linking the device to a computer.(13) In this pilot study, silent AF was detected in 1.”
MethodSelf-citationThe Use of Wearable ECG Devices in the Clinical Setting: A Review
Kamga, P., Mostafa, R., & Zafar, S. (2022) · Current Emergency and Hospital Medicine Reports · doi:10.1007/s40138-022-00248-x · Cited by 94
Emerging Technologies for Identifying Atrial Fibrillation
Ding, E., Marcus, G. M., & McManus, D. D. (2020) · Circulation Research · doi:10.1161/circresaha.119.316342 · Cited by 87
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Lowres, N., Mulcahy, G., Gallagher, R. D., Freedman, S. B., Marshman, D., Kirkness, A., Orchard, J. J., & Neubeck, L. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezv486 · Cited by 78
Benjamin, E. J., Go, A. S., Desvigne-Nickens, P., Anderson, C. D., Casadei, B., Chen, L. Y., Crijns, H. J. G. M., Freedman, B., Hills, M. T., Healey, J. S., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.047633 · Cited by 69
Self-citationHobbs, R. F., Taylor, C. J., Geersing, G. J., Rutten, F. H., Brouwer, J. R., & on behalf of the European Primary Care Cardiovascular Society (EPCCS) SPAF working group (2015) · European Journal of Preventive Cardiology · doi:10.1177/2047487315571890 · Cited by 74
“Adequate interpretation of a single-lead ECG may be considered as convincing as a 12-lead ECG for detection or exclusion of AF [33].”
How will machine learning inform the clinical care of atrial fibrillation?
Siontis, K. C., Yao, X., Pirruccello, J. P., Philippakis, A. A., & Noseworthy, P. A. (2020) · Circulation Research · doi:10.1161/circresaha.120.316401 · Cited by 61
Podd, S. J., Sugihara, C., FURNISS, S. S., & Sulke, N. (2015) · EP Europace · doi:10.1093/europace/euv367 · Cited by 63
“9%, respectively).(16) These easy-to-use, non-invasive devices are ideally suited to opportunistic sampling and therefore large screening programmes.”
BackgroundKaasenbrood, F., Hollander, M., de Bruijn, S. H., Dolmans, C. P., Tieleman, R. G., Hoes, A. W., & Rutten, F. H. (2020) · British Journal of General Practice · doi:10.3399/bjgp20x708161 · Cited by 62
Self-citationNewer technologies for detection of atrial fibrillation
Zungsontiporn, N., & Link, M. S. (2018) · BMJ · doi:10.1136/bmj.k3946 · Cited by 53
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12795 · Cited by 54
Wong, K. C., Klimis, H., Lowres, N., Huben, A. V., Marschner, S. L., & Chow, C. K. (2020) · Heart · doi:10.1136/heartjnl-2020-316611 · Cited by 51
Multiclass Classifier based Cardiovascular Condition Detection Using Smartphone Mechanocardiography
Iftikhar, Z., Lahdenoja, O., Tadi, M. J., Hurnanen, T., Vasankari, T., Kiviniemi, T., Airaksinen, J. K. E., Koivisto, T., & Pänkäälä, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-27683-9 · Cited by 51
2021 Asia Pacific Heart Rhythm Society (APHRS) practice guidance on atrial fibrillation screening
Chan, N., Orchard, J. J., Agbayani, M. F., Boddington, D., Chao, T., Johar, S., John, B., Joung, B., Krishinan, S., Krittayaphong, R., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12669 · Cited by 57
A New Entropy-Based Atrial Fibrillation Detection Method for Scanning Wearable ECG Recordings
Zhao, L., Liu, C., Wei, S., Shen, Q., Zhou, F., & Li, J. (2018) · Entropy · doi:10.3390/e20120904 · Cited by 48
“The need for improved detection of silent AF is demonstrated by the fact that almost half of the patients with an AF-related stroke, arrhythmia has been found to be asymptomatic and undiagnosed, and therefore untreated [31,32].”
BackgroundResilience to cognitive impairment in the oldest-old: design of the EMIF-AD 90+ study
Legdeur, N., Badissi, M., Carter, S. F., de Crom, S., van de Kreeke, A., Vreeswijk, R., Trappenburg, M. C., Oudega, M. L., Koek, H. L., van Campen, J. P., et al. (2018) · BMC Geriatrics · doi:10.1186/s12877-018-0984-z · Cited by 45
Boriani, G., Palmisano, P., Malavasi, V. L., Fantecchi, E., Vitolo, M., Bonini, N., Imberti, J. F., Valenti, A. C., Schnabel, R. B., & Freedman, B. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10040729 · Cited by 42
“Our study was not planned for testing the diagnostic performance of MyDiagnostick, which was already defined and reported in the literature with appropriate protocols specifically designed for this purpose [20].”
MethodBeing precise with anticoagulation to reduce adverse drug reactions: are we there yet?
Cross, B., Turner, R. M., Zhang, E. J., & Pirmohamed, M. (2024) · The Pharmacogenomics Journal · doi:10.1038/s41397-024-00329-y · Cited by 48
Seccia, T. M., Caroccia, B., Muiesan, M. L., & Rossi, G. P. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.01.007 · Cited by 49
“com)[58,59] and the MicrolifeWatchBP Home A (http://www.”
Tadi, M. J., Mehrang, S., Kaisti, M., Lahdenoja, O., Hurnanen, T., Jaakkola, J., Jaakkola, S., Vasankari, T., Kiviniemi, T., Airaksinen, J. K. E., et al. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2882874 · Cited by 44
“8) Spectral Power Features: In addition to the Spectral Peak features, we computed the total spectral power of the signal frame in different frequency bands as [0.5-1.5] Hz, [1.5-5] Hz, [5-10] Hz, [10-15] Hz, and [15-20] Hz in both accelerometer and gyroscope segmented signals independently for each sensor channel/axi…”
BackgroundInfluentialVarma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12461 · Cited by 39
Atrial fibrillation: a geriatric perspective on the 2020 ESC guidelines
Polidori, M. C., Alves, M., Bahat, G., Boureau, A., Özkök, S., Pfister, R., Pilotto, A., Veronese, N., Bo, M., & on behalf of the Special Interest Group “Cardiovascular Diseases” of the EuGMS (2021) · European Geriatric Medicine · doi:10.1007/s41999-021-00537-w · Cited by 45
“These devices also reported to be very effective and have been widely used in AF screening studies [23, 24].”
BackgroundMobile Health for Arrhythmia Diagnosis and Management
Baman, J. R., Mathew, D. T., Jiang, M. N., & PASSMAN, R. S. (2021) · Journal of General Internal Medicine · doi:10.1007/s11606-021-07007-w · Cited by 39
Uittenbogaart, S. B., Gurp, N. V.-V., Erkens, P. M. G., Lucassen, W. A. M., Knottnerus, J. A., Winkens, B., van Weert, H. C. P. M., & Stoffers, J. (2015) · Trials · doi:10.1186/s13063-015-1006-5 · Cited by 38
“The MyDiagnostick (Applied Biomedical Systems® (ABS), Maastricht, The Netherlands) is an example of a handheld ECG device, which records a singlelead ECG (left-right arm) [18].”
BackgroundScreening for Atrial Fibrillation Using a Smartphone: Is There an App for That?
Freedman, B. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.004000 · Cited by 35
Omboni, S., & Verberk, W. J. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010745 · Cited by 34
Effectiveness of the Chest Strap Electrocardiogram to Detect Atrial Fibrillation
Hartikainen, S., Lipponen, J. A., Hiltunen, P., Rissanen, T. T., Kolk, I., Tarvainen, M. P., Martikainen, T. J., Castrén, M. K., Väliaho, E., & Jäntti, H. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.02.028 · Cited by 38
Screen-detected atrial fibrillation predicts mortality in elderly subjects
Zink, M. D., Mischke, K., Keszei, A. P., Rummey, C., Freedman, B., Neumann, G., Tolksdorf, A., Frank, F., Wienströer, J., Kuth, N., et al. (2020) · EP Europace · doi:10.1093/europace/euaa190 · Cited by 33
“Participants without a history of AF and diagnosis of screendetected AF were allocated to ‘new AF’.”
BackgroundInfluentialDuarte, R., Stainthorpe, A., Mahon, J., Greenhalgh, J., Richardson, M., Nevitt, S., Kotas, E., Boland, A., Thom, H., Marshall, T., et al. (2019) · PLOS ONE · doi:10.1371/journal.pone.0226671 · Cited by 28
“The index tests evaluated included ImPulse (one study),[50] Kardia Mobile (12 studies), [31, 33, 38, 40, 41, 43, 44, 46, 48, 49, 51, 52] MyDiagnostick (four studies),[34, 39, 45, 47] Zenicor ECG (one study)[29] and MyDiagnostick and Kardia Mobile (one study).”
BackgroundMethodScreening for atrial fibrillation in hospitalised geriatric patients
Tavernier, R., Wolf, M., Kataria, V., Phlips, T., Huys, R., Taghji, P., Louw, R., Hoeyweghen, R. V., Vandekerckhove, Y. R., Knecht, S., et al. (2017) · Heart · doi:10.1136/heartjnl-2017-311981 · Cited by 30
Campo, D., Élie, V., de Gallard, T., Bartet, P., Morichau-Beauchant, T., Genain, N., Fayol, A., Fouassier, D., Pasteur‐Rousseau, A., Puymirat, É., et al. (2022) · JMIR Formative Research · doi:10.2196/37280 · Cited by 29
“These results are quite similar to those from studies on other wearable devices, such as the Apple Watch (Apple Inc) [23], the Kardia Band (AliveCor) [24], and devices by other manufacturers [25-28] (Table 6).”
MethodResultDuarte, R. V., Stainthorpe, A., Greenhalgh, J., Richardson, M., Nevitt, S. J., Mahon, J., Kotas, E., Boland, A., Thom, H. H. Z., Marshall, T. P., et al. (2020) · Health Technology Assessment · doi:10.3310/hta24030 · Cited by 32
Bimodal classification algorithm for atrial fibrillation detection from m-health ECG recordings
Kruger, G. H., Latchamsetty, R., Langhals, N. B., Yokokawa, M., Chugh, A., Morady, F., Oral, H., & Berenfeld, O. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.11.016 · Cited by 21
Electrocardiogram Devices for Home Use: Technological and Clinical Scoping Review
Zepeda-Echavarria, A., van de Leur, R. R., van Sleuwen, M., Hassink, R. J., Wildbergh, T. X., Doevendans, P. A., Jaspers, J., & van Es, R. (2023) · JMIR Cardio · doi:10.2196/44003 · Cited by 33
“Of the 36 articles, 24 (66%) evaluated the devices’ capabilities to diagnose rhythm disorders [15-17,21,24,25,29-35, 37-43,49-56], whereas 7 (20%) reported on capabilities to detect rhythm disorders and other heart conditions, such as cardiomyopathy, conduction disorders, and cardiac ischemia [18,22,23,28,36,45,57].”
BackgroundFay, M., Fitzmaurice, D. A., & Freedman, B. (2017) · European Journal of General Practice · doi:10.1080/13814788.2017.1374366 · Cited by 24
“Handheld, single-lead ECG devices are an attractive option for AF screening because the resulting ECG can be analysed by a physician in the case of a positive result, eliminating the need for a follow-up ECG [44].”
BackgroundDiagnostic accuracy of multi-lead ECGs obtained using a pocket-sized bipolar handheld event recorder
Nigolian, A., Dayal, N., Nigolian, H., Stettler, C., & Burri, H. (2017) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2017.11.004 · Cited by 22
Reverberi, C., Rabia, G., Rosa, F. D., Bosi, D., Botti, A., & Benatti, G. (2019) · BioMed Research International · doi:10.1155/2019/4861951 · Cited by 20
Beers, L., van Adrichem, L. P., Himmelreich, J. C. L., Karregat, E. P. M., de Jong, J. S. S. G., Postema, P. G., de Groot, J. R., Lucassen, W. A. M., & Harskamp, R. E. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-055072 · Cited by 20
Karregat, E. P. M., Gurp, N. V.-V., Bouwman, A. C., Uittenbogaart, S. B., Himmelreich, J. C. L., Lucassen, W. A. M., Krul, S. P. J., van Kesteren, H. A. M., LUERMANS, J. G. L. M., van Weert, H. C. P. M., et al. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.10.021 · Cited by 18
Orchard, J. J., Neubeck, L., Freedman, B., Webster, R. J., Patel, A. A., Gallagher, R. D., Li, J., Hespe, C. M., Ferguson, C., Zwar, N. A., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2018-023130 · Cited by 18
Reliability of Self-Applied Smartphone Mechanocardiography for Atrial Fibrillation Detection
Mehrang, S., Airaksinen, J. K. E., Koivisto, T., Pänkäälä, M., Tadi, M. J., Hurnanen, T., Knuutila, T., Lahdenoja, O., Jaakkola, J., Jaakkola, S., et al. (2019) · IEEE Access · doi:10.1109/access.2019.2946117 · Cited by 20
“Clinically validated devices such as smartphone- and smartwatch-coupled ECG monitors (e.g. AliveCore Kardiamobile, Kardiaband [4], Apple Watch [5], [6]), hand-held ECG recorders (e.g. Zenicor EKG [7] and Mydiagnostick [8]), the wearable ECG patch (Zio Patch [9]), wearable/mobile photoplethysmography (PPG) recorders (e…”
BackgroundSantala, O. E., Lipponen, J. A., Jäntti, H., Rissanen, T. T., Tarvainen, M. P., Laitinen, T. P., Laitinen, T. M., Castrén, M. K., Väliaho, E., Rantula, O., et al. (2022) · JMIR Cardio · doi:10.2196/31230 · Cited by 16
“In the previous studies, the sensitivity of automatic AF detection ranged from 67% to 100% and the specificity from 84% to 100% depending on the mobile or digital technology and strategy used [21-36].”
Garikapati, K., Turnbull, S., Bennett, R. G., Campbell, T. G., Kanawati, J., Wong, M. S., Thomas, S. P., Chow, C. K., & Kumar, S. (2022) · Heart Lung and Circulation · doi:10.1016/j.hlc.2022.08.001 · Cited by 24
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.11.004 · Cited by 19
“The diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care.”
BackgroundMethodInfluentialBaptista, R., Silva‐Cardoso, J., Canhão, H. M., Rodrigues, A. M., Kislaya, I., Franco, F., Bernardo, F., Pimenta, J. M., Mendes, L., Gonçalves, S., et al. (2023) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2023.10.004 · Cited by 20
Screening For Atrial Fibrillation In The Community Using A Novel ECG Recorder.
Battipaglia, I., Gilbert, K., Hogarth, A. J., & Tayebjee, M. H. (2016) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1433 · Cited by 14
To Screen or Not to Screen? Examining the Arguments Against Screening for Atrial Fibrillation
Neubeck, L., Orchard, J. J., Lowres, N., & Freedman, S. B. (2017) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.05.118 · Cited by 23
Kułach, A., Dewerenda-Sikora, M., Majewski, M., Lasek‐Bal, A., & Gąsior, Z. (2020) · Open Medicine · doi:10.1515/med-2020-0203 · Cited by 19
Dudink, E. A. M. P., Essers, B. A. B., Holvoet, W., Weijs, B., LUERMANS, J. G. L. M., Ramanna, H., Liem, A. H., van Opstal, J. M., Dekker, L., van Dijk, V. F., et al. (2016) · American Heart Journal · doi:10.1016/j.ahj.2016.09.009 · Cited by 14
Opportunistic screening for atrial fibrillation with a single lead device in geriatric patients.
Zwart, L. A. R., Jansen, R. W. M. M., Ruiter, J. H., Germans, T., Şimşek, S., & Hemels, M. E. W. (2020) · PubMed · doi:10.11909/j.issn.1671-5411.2020.03.007 · Cited by 17
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab001 · Cited by 22
Beerten, S. G., Proesmans, T., & Vaes, B. (2021) · JMIR Formative Research · doi:10.2196/24461 · Cited by 16
Palà, E., Bustamante, A., Clua‐Espuny, J. L., Acosta, J., González-Loyola, F., Santos, S. D., Ribas-Seguí, D., Ballesta-Ors, J., Peñalba, A., Giralt, M., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0273571 · Cited by 15
“MyDiagnostick (Applied Biomedical Systems, Netherlands) [11] is a single-lead ECG recorder with the shape of a stick with metallic handles (electrodes) at both ends.”
BackgroundWeijs, B., Limantoro, I., Delhaas, T., de Vos, C. B., Blaauw, Y., Houben, R. P. M., Verheule, S., Pisters, R., & Crijns, H. J. G. M. (2018) · Clinical Cardiology · doi:10.1002/clc.22877 · Cited by 12
“Heart rhythm was monitored during 4 weeks after cardioversion using a handheld telemetry device (MyDiagnostick; Applied Biomedical Systems BV, Maastricht, The Netherlands; Figure 2).(7) Patients received the MyDiagnostick 1 hour after electrical cardioversion; this was instantly the first monitoring of heart rhythm po…”
MethodSelf-citationScreening for undiagnosed atrial fibrillation
Sandhu, R. K., & Healey, J. S. (2018) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2018.1496018 · Cited by 13
“97) [34] Three-lead Automated algorithm based on pulse irregularity 0.”
MethodAtrial fibrillation detection with a portable device during cardiovascular screening in primary care
Diamantino, A. C., Nascimento, B. R., Beaton, A., Nunes, M. C. P., Oliveira, K., Rabelo, L. C., Barbosa, M. M., Tompsett, A., Olivieri, L., Mata, M. D. O., et al. (2020) · Heart · doi:10.1136/heartjnl-2019-316277 · Cited by 13
Banerjee, A. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1548554 · Cited by 16
Grubb, N. R., Elder, D. H. J., Broadhurst, P., Reoch, A., Tassie, E., & Neilson, A. R. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.03.062 · Cited by 12
Screening of unknown atrial fibrillation through handheld device in the elderly.
Rivezzi, F., Vio, R., Bilato, C., Pagliani, L., Pasquetto, G., Saccà, S., Verlato, R., Migliore, F., Iliceto, S., Bossone, V., et al. (2020) · PubMed Central · doi:10.11909/j.issn.1671-5411.2020.08.008 · Cited by 13
Mobile health technologies in the diagnosis and management of atrial fibrillation
PASSMAN, R. S. (2021) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000930 · Cited by 13
“The automated algorithms on the ECG devices detect atrial fibrillation with reported sensitivities and specificities of around 95% [10,11].”
MethodUse of digital health applications for the detection of atrial fibrillation
Lawin, D., Kühn, S., Lammers, S. S., Lawrenz, T., & Stellbrink, C. (2022) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-022-00888-2 · Cited by 10
Sattar, Y., Song, D. D., Sarvepalli, D., Zaidi, S. R., Ullah, W., Arshad, J., Mir, T., Zghouzi, M., Elgendy, I. Y., Qureshi, W., et al. (2021) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-021-01068-x · Cited by 11
Conti, S., Reiffel, J. A., Gersh, B. J., Kowey, P. R., Wachter, R., Halperin, J. L., Kaplon, R. E., Pouliot, E., & Verma, A. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1551 · Cited by 10
Mehrang, S., Tadi, M. J., Knuutila, T., Jaakkola, J., Jaakkola, S., Kiviniemi, T., Vasankari, T., Airaksinen, J. K. E., Koivisto, T., & Pänkäälä, M. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac66ba · Cited by 14
“In addition, a variety of clinically validatedwearable devices offer ECG-basedmonitoring, including smartphones and smartwatches (Lau et al2013, Tieleman et al2014,Hendrikx et al2014,Barrett et al2014,Perez et al2019).”
BackgroundIdentification of Transient Noise to Reduce False Detections in Screening for Atrial Fibrillation
Halvaei, H., Svennberg, E., Sörnmo, L., & Stridh, M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.672875 · Cited by 13
“Thanks to recent advances in low-cost technology for recording the ECG with a handheld device (Lau et al., 2013; Tieleman et al., 2014; Vaes et al., 2014), mass screening in the home environment has become feasible (Engdahl et al.”
BackgroundRegional implementation of atrial fibrillation screening: benefits and pitfalls
Theunissen, L. J. H. J., Abdalrahim, R. B. E. M., Dekker, L., Thijssen, E. J. M., de Jong, S. F. A. M. S., Polak, P. E., van der Voort, P. H., Smits, G., Scheele, K., Lucas, A. E. M., et al. (2022) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztac055 · Cited by 8
“In a prior study, the MyDiagnostick showed a 100% sensitivity and a 96% specificity for detecting AF and was described as easy to use and suitable for opportunistic AF screening.(27)”
MethodValidation of diagnostic accuracy of a handheld, smartphone-based rhythm recording device
Paul‐Nordin, A., Carnlöf, C., Insulander, P., Ali, A. M., Jensen‐Urstad, M., Saluveer, O., & Drca, N. (2023) · Expert Review of Medical Devices · doi:10.1080/17434440.2023.2171290 · Cited by 9
Zhu, X., Shi, M., Yu, X., Liu, C., Lian, X., Fei, J., Luo, J., Jin, X. Y., Zhang, P., & Ji, X. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106939 · Cited by 10
Kao, W., Hou, S., Huang, C., Chao, C., Cheng, C.-C., & Chen, Y.-J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0198852 · Cited by 8
Gahungu, N., Judkins, C., Gabbay, E., & Playford, D. A. (2019) · Sleep Medicine · doi:10.1016/j.sleep.2019.01.036 · Cited by 7
Collaborators, T. A. S. A. A.-E. (2023) · Thrombosis and Haemostasis · doi:10.1055/s-0042-1760257 · Cited by 9
Intelligent algorithms powered smart devices for atrial fibrillation discrimination
Xie, L., Wang, L., Mo, D., Zhang, Z., & Liang, M. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.107480 · Cited by 7
Hernández, J. M. D. L. T., Ongay, A. G., Villarroel, T. B., Lizarbe, S. G., Fernández, G. V., Villa, S. C., Majado, B. D. T., González, M. L., Quirico, M. M. S., Lozano, D. S., et al. (2020) · REC CardioClinics · doi:10.1016/j.rccl.2020.07.005 · Cited by 6
Smartphone and new tools for atrial fibrillation diagnosis: evidence for clinical applicability
PAPACCIOLI, G., BASSI, G., Cecilia, L. U. G. I., Parente, E., D’ANDREA, A., PROIETTI, R., Imbalzano, E., TURKI, A. A., & Russo, V. (2022) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.22.05841-0 · Cited by 8
Jones, I. D., Lane, D. A., Lotto, R. R., Oxborough, D., Neubeck, L., Penson, P. E., Czanner, G., Shaw, A., Smith, E. J., Santos, A., et al. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12040578 · Cited by 7
“The sensor used within this study, MyDiagnostick has been shown to be highly sensitive in detecting AF, with sensitivity levels ranging between 94% (95% CI 87–98%) [28] to 100% (95% CI 93–100%) [29].”
BackgroundMethodCan screening for atrial fibrillation be implemented at scale?
Lowres, N., Neubeck, L., & Freedman, S. B. (2016) · EP Europace · doi:10.1093/europace/euw030 · Cited by 7
Santala, O. E., Lipponen, J. A., Jäntti, H., Rissanen, T. T., Tarvainen, M. P., Väliaho, E., Rantula, O., Naukkarinen, N. S., Hartikainen, J. E. K., Martikainen, T. J., et al. (2023) · Cardiology in Review · doi:10.1097/crd.0000000000000526 · Cited by 11
Malmqvist, J., Engdahl, J., Sjölund, G., & Doliwa, P. S. (2024) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2024.02.001 · Cited by 6
Gurp, N. V.-V., van Bladel, P. J. M., van Kesteren, H. A. M., Erkens, P. M. G., & Stoffers, J. (2017) · Netherlands Heart Journal · doi:10.1007/s12471-017-1010-3 · Cited by 6
“Several studies show positive results regarding the use of new devices for AF detection [9, 10].”
BackgroundThe future of long‐term monitoring after catheter and surgical ablation for atrial fibrillation
Baman, J. R., & PASSMAN, R. S. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15375 · Cited by 8
Magnusson, P., Lyren, A., & Mattsson, G. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-037360 · Cited by 6
Varma, N., Cygankiewicz, I., & Turakhia, M. P. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4420 · Cited by 7
Opportunities and challenges of large-scale screening for atrial fibrillation
Zink, M. D., Marx, N., Crijns, H. J. G. M., & Schotten, U. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-017-0550-y · Cited by 4
Metadata
- Authors
- Tieleman, R. G., Plantinga, Y., Rinkes, D., Bartels, G. L., Posma, J. L., Cator, R., Hofman, C., & Houben, R. P.
- Affiliations
- Martini Ziekenhuis (NL)
- Corresponding author
- Tieleman, R. G.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-05-13
- Volume
- 16
- Issue
- 9
- Pages
- 1291-1295
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- PMC
- PMC4149608
- OpenAlex
- W2152856261
- Semantic Scholar
- 7410db84a993afb11b9a659aae27177733ee6238
- Cited by
- 138
- References
- 26
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 9 · 2023: 7 · 2022: 18 · 2021: 22 · 2020: 14 · 2019: 8 · 2018: 14 · 2017: 11 · 2016: 20 · 2015: 5
- FWCI
- 8.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- EP Europace (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (submittedVersion, cc-by-nc)
- Research Publications (Maastricht University) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- atrial fibrillation, atrial fibrillation screening, automated ECG analysis, influenza vaccination, general practitioners, undiagnosed atrial fibrillation, CHA2DS2-VASc score, stroke risk, diagnostic accuracy
- MeSH terms
- Aged, Atrial Fibrillation, Diagnosis, Computer-Assisted, Equipment Design, Female, Humans, Male, Mass Screening, Miniaturization, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Reproducibility of Results, Electrocardiography, Ambulatory, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.