The DOI matches its Crossref record; 136 of the 136 references it cites were found in a registry or an index.
Guidelines for the diagnosis, prevention and management of implantable cardiac electronic device infection. Report of a joint Working Party project on behalf of the British Society for Antimicrobial Chemotherapy (BSAC, host organization), British Heart Rhythm Society (BHRS), British Cardiovascular Society (BCS), British Heart Valve Society (BHVS) and British Society for Echocardiography (BSE)
Abstract
Infections related to implantable cardiac electronic devices (ICEDs), including pacemakers, implantable cardiac defibrillators and cardiac resynchronization therapy devices, are increasing in incidence in the USA and are likely to increase in the UK, because more devices are being implanted. These devices have both intravascular and extravascular components and infection can involve the generator, device leads and native cardiac structures or various combinations. ICED infections can be life-threatening, particularly when associated with endocardial infection, and all-cause mortality of up to 35% has been reported. Like infective endocarditis, ICED infections can be difficult to diagnose and manage. This guideline aims to (i) improve the quality of care provided to patients with ICEDs, (ii) provide an educational resource for all relevant healthcare professionals, (iii) encourage a multidisciplinary approach to ICED infection management, (iv) promote a standardized approach to the diagnosis, management, surveillance and prevention of ICED infection through pragmatic evidence-rated recommendations, and (v) advise on future research projects/audit. The guideline is intended to assist in the clinical care of patients with suspected or confirmed ICED infection in the UK, to inform local infection prevention and treatment policies and guidelines and to be used in the development of educational and training material by the relevant professional societies. The questions covered by the guideline are presented at the beginning of each section.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proposed Modifications to the Duke Criteria for the Diagnosis of Infective Endocarditis
Li, J. S., Sexton, D. J., Mick, N., Nettles, R., Fowler, V. G., Ryan, T., Bashore, T., & Corey, G. R. (2000) · Clinical Infectious Diseases · doi:10.1086/313753 · Cited by 4,027
Clinical practice guidelines for antimicrobial prophylaxis in surgery
Bratzler, D. W., Dellinger, E. P., Olsen, K. M., Perl, T. M., Auwaerter, P. G., Bolon, M. K., Fish, D. N., Napolitano, L. M., Sawyer, R. G., Slain, D., et al. (2013) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp120568 · Cited by 2,591
Durack, D. T., Lukes, A. S., Bright, D. K., & Service, D. E. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90143-0 · Cited by 2,572
Murdoch, D. R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2008.603 · Cited by 2,362
Guidelines on the prevention, diagnosis, and treatment of infective endocarditis (new version 2009)
Endorsed by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) and by the International Society of Chemotherapy (ISC) for Infection and Cancer, Habib, G., Hoen, B., Tornos, P., Thuny, F., Prendergast, B., Vilacosta, I., Moreillon, P., de Jesus Antunes, M., Thilen, U., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp285 · Cited by 2,014
Self-citationSummary of product characteristics
(2013) · Pharmaceutical Medicine · doi:10.1093/med/9780199609147.003.0027 · Cited by 1,905
The Timing of Prophylactic Administration of Antibiotics and the Risk of Surgical-Wound Infection
Classen, D. C., Evans, R. S., Pestotnik, S. L., Horn, S. D., Menlove, R. L., & Burke, J. P. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201303260501 · Cited by 1,739
Chlorhexidine–Alcohol versus Povidone–Iodine for Surgical-Site Antisepsis
Darouiche, R. O., Wall, M. J., Itani, K. M. F., Otterson, M. F., Webb, A. L., Carrick, M. M., Miller, H. J., Awad, S. S., Crosby, C. T., Mosier, M. C., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0810988 · Cited by 1,486
Wilkoff, B. L., Love, C. J., Byrd, C. L., Bongiorni, M. G., Carrillo, R. G., Crossley, G. H., Epstein, L. M., Friedman, R. A., Kennergren, C. E. H., Mitkowski, P., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.05.020 · Cited by 1,024
Poole, J. E., Gleva, M. J., Mela, T., Chung, M. K., Uslan, D. Z., Borge, R., Gottipaty, V., Shinn, T., Dan, D., Feldman, L. A., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.976076 · Cited by 790
Greenspon, A. J., Patel, J. D., Lau, E., Ochoa, J. A., Frisch, D. R., Ho, R. T., Pavri, B. B., & Kurtz, S. M. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.04.033 · Cited by 780
Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S., & Baddour, L. M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.072 · Cited by 751
Klug, D., Balde, M., Pavin, D., Hidden-Lucet, F., Clementy, J., Sadoul, N., Rey, J. L., Lande, G., Lazarus, A., Victor, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.678664 · Cited by 700
Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management
Klug, D., Lacroix, D., Savoye, C., Goullard, L., Grandmougin, D., Hennequin, J. L., Kacet, S., & Lekieffre, J. (1997) · Circulation · doi:10.1161/01.cir.95.8.2098 · Cited by 593
Gould, F. K., Denning, D. W., Elliott, T. S. J., Foweraker, J., Perry, J. D., Prendergast, B. D., Sandoe, J. A. T., Spry, M. J., & Watkin, R. W. (2012) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkr450 · Cited by 593
Self-citationPacemaker or Defibrillator Surgery without Interruption of Anticoagulation
Birnie, D. H., Healey, J. S., Wells, G. A., Verma, A., Tang, A. S., Krahn, A. D., Simpson, C. S., Ayala-Paredes, F., Coutu, B., Leiria, T. L. L., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1302946 · Cited by 579
Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac Devices
Chua, J. D., Wilkoff, B. L., Lee, I., Juratli, N., Longworth, D. L., & Gordon, S. M. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-8-200010170-00011 · Cited by 511
Steinberg, J. P., Braun, B. I., Hellinger, W. C., Kusek, L., Bozikis, M. R., Bush, A. J., Dellinger, E. P., Burke, J. P., SIMMONS, B. P., & Kritchevsky, S. B. (2009) · Annals of Surgery · doi:10.1097/sla.0b013e3181ad5fca · Cited by 449
VOIGT, A., SHALABY, A., & SABA, S. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02569.x · Cited by 396
Annual Report of the Chief Medical Officer: infection and the rise of antimicrobial resistance
Davies, S. C., Fowler, T., Watson, J., Livermore, D. M., & Walker, D. (2013) · The Lancet · doi:10.1016/s0140-6736(13)60604-2 · Cited by 393
Permanent Pacemaker and Implantable Cardioverter Defibrillator Infection: A Population-Based Study
Uslan, D. Z. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.7.669 · Cited by 391
Johansen, J. B., Jorgensen, O. D., Moller, M., Arnsbo, P., Mortensen, P. T., & Nielsen, J. C. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq497 · Cited by 376
Antibiotic Prophylaxis for Permanent Pacemaker Implantation: A Meta-Analysis
Da Costa, A., Kirkorian, G., Cucherat, M., Delahaye, F., Chevalier, P., Cerisier, A., Isaaz, K., & Touboul, P. (1998) · Circulation · doi:10.1161/01.cir.97.18.1796 · Cited by 362
Mortality and Cost Associated With Cardiovascular Implantable Electronic Device Infections
Sohail, M. R. (2011) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.441 · Cited by 350
Raad, I., Hanna, H., Jiang, Y., Dvorak, T., Reitzel, R., Chaiban, G., Sherertz, R., & Hachem, R. (2007) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00350-06 · Cited by 350
de Oliveira, J. C., Martinelli, M., Nishioka, S. A. D., Varejão, T., Uipe, D., Pedrosa, A. A. A., Costa, R., & Danik, S. B. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.795906 · Cited by 349
A scanning and transmission electron microscopic study of an infected endocardial pacemaker lead.
Marrie, T. J., Nelligan, J., & Costerton, J. W. (1982) · Circulation · doi:10.1161/01.cir.66.6.1339 · Cited by 347
Clinical Characteristics and Outcome of Infective Endocarditis Involving Implantable Cardiac Devices
Chu, V. H. (2012) · JAMA · doi:10.1001/jama.2012.497 · Cited by 324
Pacemaker infective endocarditis
Cacoub, P., Leprince, P., Nataf, P., Hausfater, P., Dorent, R., Wechsler, B., Bors, V., Pavie, A., Piette, J. C., & Gandjbakhch, I. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00365-8 · Cited by 314
Chamis, A. L., Peterson, G. E., Cabell, C. H., Corey, G. R., Sorrentino, R. A., Greenfield, R. A., Ryan, T., Reller, L. B., & Fowler, V. G. (2001) · Circulation · doi:10.1161/hc3401.095097 · Cited by 292
Risk Factor Analysis of Permanent Pacemaker Infection
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S. M., & Baddour, L. M. (2007) · Clinical Infectious Diseases · doi:10.1086/518889 · Cited by 288
Cardiac implantable electronic device infections: Presentation, management, and patient outcomes
Tarakji, K. G., Chan, E. J., Cantillon, D. J., Doonan, A. L., Hu, T., Schmitt, S., Fraser, T. G., Kim, A., Gordon, S. M., & Wilkoff, B. L. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.05.016 · Cited by 286
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Jenkins, S. M., & Baddour, L. M. (2008) · Mayo Clinic Proceedings · doi:10.4065/83.1.46 · Cited by 285
Sarrazin, J.-F., Philippon, F., Tessier, M., Guimond, J., Molin, F., Champagne, J., Nault, I., Blier, L., Nadeau, M., Charbonneau, L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.059 · Cited by 285
Eradication of Methicillin‐Resistant Staphylococcus aureus Carriage: A Systematic Review
Ammerlaan, H. S. M., Kluytmans, J. A. J. W., Wertheim, H. F. L., Nouwen, J. L., & Bonten, M. J. M. (2009) · Clinical Infectious Diseases · doi:10.1086/597291 · Cited by 277
Use of plastic adhesive drapes during surgery for preventing surgical site infection
Webster, J., & Alghamdi, A. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006353.pub4 · Cited by 266
Cook, R. J., Ashton, R. W., Aughenbaugh, G. L., & Ryu, J. H. (2005) · CHEST Journal · doi:10.1378/chest.128.1.162 · Cited by 258
Surgical Treatment of Pacemaker and Defibrillator Lead Endocarditis
del Río, A., Anguera, I., Miró, J. M., Mont, L., Fowler, V. G., Azqueta, M., & Mestres, C. A. (2003) · Chest · doi:10.1378/chest.124.4.1451 · Cited by 256
Aggarwal, R. K., Connelly, D. T., Ray, S. G., Ball, J., & Charles, R. G. (1995) · Heart · doi:10.1136/hrt.73.6.571 · Cited by 254
Lee, I., Agarwal, R. K., Lee, B. Y., Fishman, N. O., & Umscheid, C. A. (2010) · Infection Control & Hospital Epidemiology · doi:10.1086/657134 · Cited by 252
León, A. R., Abraham, W. T., Curtis, A. B., Daubert, J. P., Fisher, W. G., Gurley, J., Hayes, D. L., Lieberman, R., Petersen-Stejskal, S., & Wheelan, K. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.031 · Cited by 250
Risk factors and time delay associated with cardiac device infections: Leiden device registry
Lekkerkerker, J. C., van Nieuwkoop, C., Trines, S. A., van der Bom, J. G., Bernards, A., van de Velde, E. T., Bootsma, M., Zeppenfeld, K., Jukema, J. W., Borleffs, J.-W., et al. (2009) · Heart · doi:10.1136/hrt.2008.151985 · Cited by 234
Pacemaker lead infection: echocardiographic features, management, and outcome
Victor, F., De Place, C., Camus, C., Le Breton, H., Leclercq, C., Pavin, D., Mabo, P., & Daubert, C. (1999) · Heart · doi:10.1136/hrt.81.1.82 · Cited by 221
Renal Insufficiency and the Risk of Infection from Pacemaker or Defibrillator Surgery
BLOOM, H., HEEKE, B., LEON, A., MERA, F., DELURGIO, D., BESHAI, J., & LANGBERG, J. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00307.x · Cited by 220
Early Complications After Dual Chamber Versus Single Chamber Pacemaker Implantation
CHAUHAN, A., GRACE, A. A., NEWELL, S. A., STONE, D. L., SHAPIRO, L. M., SCHOFIELD, P. M., & PETCH, M. C. (1994) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1994.tb03791.x · Cited by 217
Local symptoms at the site of pacemaker implantation indicate latent systemic infection
Klug, D., Wallet, F., Lacroix, D., Marquié, C., Kouakam, C., Kacet, S., & Courcol, R. (2004) · Heart · doi:10.1136/hrt.2003.010595 · Cited by 195
Al-Khatib, S. M., Lucas, F. L., Jollis, J. G., Malenka, D. J., & Wennberg, D. E. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.04.063 · Cited by 194
Gould, F. K. (2012) · Journal of Antimicrobial Chemotherapy · Cited by 193
NERY, P. B., FERNANDES, R., NAIR, G. M., SUMNER, G. L., RIBAS, C. S., MENON, S. M. D., WANG, X., KRAHN, A. D., MORILLO, C. A., CONNOLLY, S. J., et al. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01690.x · Cited by 188
Sakoulas, G., Bayer, A. S., Pogliano, J., Tsuji, B. T., Yang, S.-J., Mishra, N. N., Nizet, V., Yeaman, M. R., & Moise, P. A. (2012) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.05551-11 · Cited by 176
Extraction of Transvenous Pacing and ICD Leads
SMITH, M. C., & LOVE, C. J. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01079.x · Cited by 167
USLAN, D. Z., GLEVA, M. J., WARREN, D. K., MELA, T., CHUNG, M. K., GOTTIPATY, V., BORGE, R., DAN, D., SHINN, T., MITCHELL, K., et al. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03257.x · Cited by 160
Tompkins, C., Cheng, A., Dalal, D., Brinker, J. A., Leng, C. T., Marine, J. E., Nazarian, S., Spragg, D. D., Sinha, S., Halperin, H., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.056 · Cited by 159
Microbiology of cardiac implantable electronic device infections
Bongiorni, M. G., Tascini, C., Tagliaferri, E., Cori, A. D., Soldati, E., Leonildi, A., Zucchelli, G., Ciullo, I., & Menichetti, F. (2012) · EP Europace · doi:10.1093/europace/eus044 · Cited by 155
Use of plastic adhesive drapes during surgery for preventing surgical site infection
Webster, J., & Alghamdi, A. (2007) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006353.pub2 · Cited by 154
Deharo, J., Quatre, A., Mancini, J., Khairy, P., Dolley, Y. L., Casalta, J., Peyrouse, E., Prévôt, S., Thuny, F., Collart, F., et al. (2012) · Heart · doi:10.1136/heartjnl-2012-301627 · Cited by 154
Grammes, J. A., Schulze, C., Al-Bataineh, M., Yesenosky, G. A., Saari, C. S., Vrabel, M. J., Horrow, J. C., Chowdhury, M., Fontaine, J. M., & Kutalek, S. P. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.034 · Cited by 149
Narducci, M. L., Pelargonio, G., Russo, E., Marinaccio, L., Monaco, A. D., Perna, F., Bencardino, G., Casella, M., Biase, L. D., Santangeli, P., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.12.041 · Cited by 146
Prevalence and risk factors related to infections of cardiac resynchronization therapy devices
Romeyer-Bouchard, C., Costa, A. D., Dauphinot, V., Messier, M., Bisch, L., Samuel, B., Lafond, P., Ricci, P., & Isaaz, K. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp421 · Cited by 144
Implantable Defibrillation: Eight Years Clinical Experience
Thomas, A. C., Moser, S. A., Smutka, M. L., & WILSON, P. A. (1988) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1988.tb06349.x · Cited by 142
Risk Factors for Mortality in Patients With Cardiac Device-Related Infection
Baman, T. S., Gupta, S. K., Valle, J. A., & Yamada, E. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.816868 · Cited by 139
Camus, C., Leport, C., Raffi, F., Michelet, C., Cartier, F., & Vildé, J. (1993) · Clinical Infectious Diseases · doi:10.1093/clinids/17.1.46 · Cited by 138
The Role of Swab and Tissue Culture in the Diagnosis of Implantable Cardiac Device Infection
Chua, J. D., Abdul‐Karim, A., Mawhorter, S. D., Procop, G. W., TCHOU, P. J., Niebauer, M. J., Saliba, W. I., Schweikert, R. A., & Wilkoff, B. L. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00268.x · Cited by 137
Smith, K., Perez, A., Ramage, G., Gemmell, C. G., & Lang, S. (2008) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2008.08.029 · Cited by 137
Viganego, F., O’Donoghue, S., ELDADAH, Z. A., Shah, M. H., Rastogi, M., Mazel, J. A., & Platia, E. V. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.01.360 · Cited by 129
Rohacek, M., Weisser, M., Kobza, R., Schoenenberger, A. W., Pfyffer, G. E., Frei, R., Erné, P., & Trampuž, A. (2010) · Circulation · doi:10.1161/circulationaha.109.906461 · Cited by 127
Risk of Hematoma Complications After Device Implant in the Clopidogrel Era
Kutinsky, I. B., Jarandilla, R., Jewett, M. C., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.917625 · Cited by 126
End-Stage Renal Disease Predicts Complications in Pacemaker and ICD Implants
TOMPKINS, C. M., McLean, R. C., Cheng, A., Brinker, J., Marine, J. E., Nazarian, S., SPRAGG, D. D., Sinha, S. K., Halperin, H. R., Tomaselli, G. F., et al. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02066.x · Cited by 126
Mela, T., McGovern, B. A., Garan, H., Vlahakes, G. J., Torchiana, D. F., Ruskin, J. N., & Galvin, J. M. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01845-8 · Cited by 122
Pacemaker Endocarditis: Clinical Features and Management of 60 Consecutive Cases
Massoure, P., Reuter, S., Lafitte, S., Laborderie, J., BORDACHARD, P., Clémenty, J., & Roudaut, R. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00574.x · Cited by 121
Al‐Khatib, S. M., Greiner, M. A., Peterson, E. D., Hernandez, A. F., Schulman, K. A., & Curtis, L. H. (2008) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.777888 · Cited by 120
Ploux, S., Rivière, A., Amraoui, S., Whinnett, Z. I., Barandon, L., Lafitte, S., Ritter, P., PAPAIOANNOU, G. I., Clémenty, J., Jaïs, P., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.03.062 · Cited by 118
Uslan, D. Z., Sohail, M. R., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., & Baddour, L. M. (2006) · Clinical Infectious Diseases · doi:10.1086/506942 · Cited by 118
Non-susceptibility trends among staphylococci from bacteraemias in the UK and Ireland, 2001-06
Hope, R., Livermore, D. M., Brick, G., Lillie, M., Reynolds, R., & Surveillance, O. B. O. T. B. W. P. O. R. (2008) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkn353 · Cited by 117
Meier-Ewert, H. K., Gray, M. E., & John, R. M. (2003) · American Heart Journal · doi:10.1016/s0002-8703(03)00188-1 · Cited by 110
Lin, J. C., Fierer, J., Aung, G., Johns, S., Thomas, A., Jahng, M., Fierer, J., & Fierer, J. (2013) · Journal of Infection and Chemotherapy · doi:10.1007/s10156-012-0449-9 · Cited by 109
Bloom, H. L., Constantin, L., DAN, D., Lurgio, D. B. D., El‐Chami, M. F., Ganz, L. I., Gleed, K., Hackett, F. K., Kanuru, N. K., Lerner, D. J., et al. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02931.x · Cited by 109
Pacemaker Endocarditis During 18 Years in Göteborg
Rundström, H., Kennergren, C. E. H., Andersson, R., Alestig, K., & Hogevik, H. (2004) · Scandinavian Journal of Infectious Diseases · doi:10.1080/00365540410022611 · Cited by 108
Landolina, M., Gasparini, M., Lunati, M., Iacopino, S., Boriani, G., Bonanno, C., Vado, A., Proclemer, A., Capucci, A., Zucchiatti, C., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.015024 · Cited by 103
Gold, M. R., Peters, R. W., Johnson, J. W., & Shorofsky, S. R. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00314-2 · Cited by 102
Uslan, D. Z., Dowsley, T. F., Sohail, M. R., Hayes, D. L., Friedman, P. A., Wilson, W. R., Steckelberg, J. M., & Baddour, L. M. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02565.x · Cited by 102
Carugati, M., Bayer, A. S., Miró, J. M., Park, L. P., Guimarães, A. C., Skoutelis, A., Fortes, C. Q., Durante-Mangoni, E., Hannan, M. M., Nacinovich, F., et al. (2013) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.01563-13 · Cited by 100
Kullar, R., Casapao, A. M., Davis, S. L., Levine, D. P., Zhao, J. J., Crank, C. W., Segreti, J., Sakoulas, G., Cosgrove, S. E., & Rybak, M. J. (2013) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkt294 · Cited by 99
Pacemaker Infections: A 10-Year Experience
Catanchin, A., Murdock, C. J., & Athan, E. (2007) · Heart Lung and Circulation · doi:10.1016/j.hlc.2007.02.097 · Cited by 98
Predictors of Mortality in Patients With Cardiovascular Implantable Electronic Device Infections
Habib, A., LE, K. Y., Baddour, L. M., Friedman, P. A., Hayes, D. L., Lohse, C. M., Wilson, W. R., Steckelberg, J. M., & Sohail, M. R. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.11.052 · Cited by 96
Greenspon, A. J., Prutkin, J. M., Sohail, M. R., Vikram, H. R., Baddour, L. M., Danik, S. B., Peacock, J. E., Falces, C., Miró, J. M., Blank, E., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.011 · Cited by 92
Microbiology and Pathogenesis of Cardiovascular Implantable Electronic Device Infections
Nagpal, A., Baddour, L. M., & Sohail, M. R. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.962753 · Cited by 90
Freeman, J. V., Wang, Y., Curtis, J. P., Heidenreich, P. A., & Hlatky, M. A. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.07.007 · Cited by 89
Clinical Predictors of Cardiovascular Implantable Electronic Device‐Related Infective Endocarditis
LE, K. Y., Sohail, M. R., Friedman, P. A., Uslan, D. Z., CHA, S. S., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Baddour, L. M., & for the Mayo Cardiovascular Infections Study Group (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02991.x · Cited by 88
Multicenter Study of High-Dose Daptomycin for Treatment of Enterococcal Infections
Casapao, A. M., Kullar, R., Davis, S. L., Levine, D. P., Zhao, J. J., Potoski, B. A., Goff, D. A., Crank, C. W., Segreti, J., Sakoulas, G., et al. (2013) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00526-13 · Cited by 88
Kleemann, T., Becker, T., Strauss, M., Dyck, N., Weisse, U., Saggau, W., Burkhardt, U., & Seidl, K. (2009) · EP Europace · doi:10.1093/europace/eup334 · Cited by 87
Small Colony Variants of Staphylococcus aureus and Pacemaker-related Infection
Seifert, H., Wisplinghoff, H., Schnabel, P., & von Eiff, C. (2003) · Emerging infectious diseases · doi:10.3201/eid0910.0302000 · Cited by 86
Downey, B. C., Juselius, W. E., Pandian, N. G., Estes, N. A. M., & Link, M. S. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03034.x · Cited by 84
Nonstaphylococcal Infections of Cardiac Implantable Electronic Devices
Viola, G. M., Awan, L. L., & Darouiche, R. O. (2010) · Circulation · doi:10.1161/circulationaha.110.936708 · Cited by 82
Trappe, H., PFITZNER, P., Klein, H., & WENZLAFF, P. (1995) · Heart · doi:10.1136/hrt.73.1.20 · Cited by 79
Chen, W., Kim, J., Molchanova-Cook, O. P., & Dilsizian, V. (2014) · Current Cardiology Reports · doi:10.1007/s11886-013-0459-y · Cited by 78
Farooqi, F., Talsania, S., Hamid, S., & Rinaldi, C. A. (2010) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2010.02338.x · Cited by 76
Infections with Nonthoracotomy Implantable Cardioverter Defibrillators: Can These Be Prevented?
Smith, P. N., Vidaillet, H. J., Jr., Hayes, J. J., WETHINGTON, P. J., VOSHAGE‐STAHL, L., HULL, M. L., & Broste, S. K. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01060.x · Cited by 71
Pacemaker and Defibrillator Lead Extraction: Predictors of Mortality during Follow-Up
Hamid, S., Arujuna, A., Ginks, M., McPhail, M. J. W., Patel, N., Bucknall, C. A., & Rinaldi, C. A. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02601.x · Cited by 69
Prioritizing echocardiography in Staphylococcus aureus bacteraemia
Joseph, J. P., Meddows, T. R., Webster, D. P., Newton, J. D., Myerson, S. G., Prendergast, B. D., Scarborough, M., & Herring, N. (2012) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dks408 · Cited by 69
Self-citationMadhavan, M., Sohail, M. R., Friedman, P. A., Hayes, D. L., Steckelberg, J. M., Wilson, W. R., Baddour, L. M., & for the Mayo Cardiovascular Infections Study Group (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.110.957514 · Cited by 68
High-Dose Daptomycin for Cardiac Implantable Electronic Device-Related Infective Endocarditis
Durante‐Mangoni, E., Casillo, R., Bernardo, M., Caianiello, C., Mattucci, I., Pinto, D., Agrusta, F., Caprioli, R., Albisinni, R., Ragone, E., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir805 · Cited by 67
Lo, R., D'Anca, M., Cohen, T. J., & Kerwin, T. C. (2006) · PubMed · Cited by 63
A review of temporary cardiac pacing wires.
McCann, P. (2007) · PubMed · Cited by 63
A 15-Year Experience With Permanent Pacemaker and Defibrillator Lead and Patch Extractions
Rusanov, A., & Spotnitz, H. M. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.10.025 · Cited by 63
Pichlmaier, M. A., Knigina, L., Kutschka, I., Bara, C., Oswald, H., Klein, G. G., Bisdas, T., & Haverich, A. (2011) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2010.11.059 · Cited by 63
High prevalence of asymptomatic bacterial colonization of rhythm management devices
Pichlmaier, M., Marwitz, V., Kühn, C., Niehaus, M., Klein, G. G., Bara, C., Haverich, A., & Abraham, W. (2008) · EP Europace · doi:10.1093/europace/eun191 · Cited by 63
Darouiche, R. O., Mosier, M. C., & Voigt, J. D. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03506.x · Cited by 55
Diagnosis of Cardiac Device–Related Infective Endocarditis After Device Removal
Dolley, Y. L., Thuny, F., Mancini, J., Casalta, J., Ribéri, A., Gouriet, F., Bastard, E., Ansaldi, S., Franceschi, F., Renard, S., et al. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2009.12.016 · Cited by 55
Challagundla, S. R., Knox, D. N., Hawkins, A., Hamilton, D. F., Flynn, R. W. V., Robertson, S., & Isles, C. (2012) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfs458 · Cited by 55
Diagnosis and management of staphylococcal infections of pacemakers and cardiac defibrillators
Chambers, S. T. (2005) · Internal Medicine Journal · doi:10.1111/j.1444-0903.2005.00980.x · Cited by 50
Sustained Bacteremia and Transvenous Cardiac Pacemakers
Corman, L. C., & Levison, M. E. (1975) · JAMA · doi:10.1001/jama.1975.03260030054023 · Cited by 48
Hansen, L. K., Berg, K., Johnson, D., Sanders, M., & Citron, M. (2010) · The International Journal of Artificial Organs · doi:10.1177/039139881003300908 · Cited by 43
How to select patients for lead extraction
Field, M. E., Jones, S. O., & Epstein, L. M. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.05.022 · Cited by 42
Lever, N. A., Ferguson, J. D., Bashir, Y., et al. (2003) · Heart · doi:10.1136/heart.89.2.209 · Cited by 42
Wilson, A. P. R., Taylor, B., Treasure, T., et al. (1988) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/21.2.201 · Cited by 39
JAN, E., Camou, F., Texier-Maugein, J., Whinnett, Z. I., Caubet, O., Ploux, S., Pellegrin, J., Ritter, P., Métayer, P. L., Roudaut, R., et al. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02212.x · Cited by 36
Agostinho, A. M., James, G. A., Wazni, O. M., Citron, M., & Wilkoff, B. L. (2009) · Clinical and Translational Science · doi:10.1111/j.1752-8062.2009.00123.x · Cited by 35
Kratz, J. M., & Toole, J. M. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.05.036 · Cited by 34
Knigina, L., Kühn, C., Kutschka, I., Oswald, H., Klein, G., Haverich, A., & Pichlmaier, M. A. (2010) · EP Europace · doi:10.1093/europace/euq192 · Cited by 27
Infected pacemaker causing septic lung emboli detected on FDG PET/CT
Abikhzer, G., Turpin, S., & Bigras, J. (2009) · Journal of Nuclear Cardiology · doi:10.1007/s12350-009-9160-3 · Cited by 24
Rodriguez, D. J., Afzal, A., Evonich, R. F., & Haines, D. E. (2012) · PubMed · Cited by 21
Tayebjee, M. H., Joy, E., & Sandoe, J. A. T. (2013) · Journal of Medical Microbiology · doi:10.1099/jmm.0.057042-0 · Cited by 20
Self-citationLepillier, A., Otmani, A., Waintraub, X., Ollitrault, J., Heuzey, J. Y. L., & Lavergne, T. (2012) · EP Europace · doi:10.1093/europace/eur403 · Cited by 20
Infection of intravascular prostheses: how to treat other than surgery
Utili, R., Durante‐Mangoni, E., & Tripodi, M. (2007) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2007.06.028 · Cited by 19
Therapy of Cardiac Device Pocket Infections with Vacuum‐Assisted Wound Closure—Long‐Term Follow‐Up
Poller, W. C., Schwerg, M., & Melzer, C. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03479.x · Cited by 18
Athan, E., Chu, V. H., Tattevin, P., et al. (2013) · International Journal of Antimicrobial Agents · doi:10.1016/s0924-8579(13)70010-4 · Cited by 18
Long‐Term Outcomes after Pocket or Scar Revision and Reimplantation of Pacemakers with Preerosion
Cassagneau, R., Ploux, S., Ritter, P., JAN, E., Barandon, L., Deplagne, A., Clémenty, J., Haïssaguerre, M., & Bordachar, P. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02950.x · Cited by 17
Pacemaker-related endocarditis: clinical features and treatment.
Ortiz, M. R., Anguita, M. P., Castillo, J. C., Delgado, M., Romo, E., Torres, F., Mesa, D., Franco, M., & Vallés, F. (2006) · PubMed · Cited by 12
Lattouf, O. M. (2006) · Cambridge University Press eBooks · doi:10.1017/cbo9780511544590.067 · Cited by 11
Recurrent candidaemia and pacemaker wire infection with Candida albicans
Glöckner, A. (2011) · Mycoses · doi:10.1111/j.1439-0507.2011.02139.x · Cited by 9
Gouriet, F., Bayle, S., Dolley, Y. L., Seng, P., Cammilleri, S., Stein, A., Casalta, J., Habib, G., & Raoult, D. (2013) · Scandinavian Journal of Infectious Diseases · doi:10.3109/00365548.2013.767472 · Cited by 6
Simpson, L., Bhella, P. S., SCHUSSLER, J. M., Grayburn, P. A., & Assar, M. D. (2010) · Baylor University Medical Center Proceedings · doi:10.1080/08998280.2010.11928629 · Cited by 5
Peixoto, G. D. L., Siciliano, R. F., de Camargo, R. A., Bueno, F. L., Júnior, J. S., Costa, R., Strabelli, T. M. V., & Filho, M. M. (2013) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2013.10.011 · Cited by 4
Detection of Pacemaker Lead Infection by Fluorodeoxyglucose Positron Emission Tomography
Miura, T., Kinoshita, O., Horigome, M., Kasai, H., Aizawa, K., Yoshioka, T., Tomita, T., Kumazaki, S., Tsutsui, H., Koyama, J., et al. (2006) · Journal of Arrhythmia · doi:10.1016/s1880-4276(06)80034-7 · Cited by 3
Sandoe, J. A. T., & Baig, W. (2012) · Future Cardiology · doi:10.2217/fca.12.41 · Cited by 3
Self-citation
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Cahill, T. J., & Prendergast, B. D. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00067-7 · Cited by 991
Self-citationChallenges in Infective Endocarditis
Cahill, T. J., Baddour, L. M., Habib, G., Hoen, B., Salaun, E., Pettersson, G. B., Schäfers, H. J., & Prendergast, B. D. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.066 · Cited by 715
Self-citationDilsizian, V., Bacharach, S. L., Beanlands, R. S., Bergmann, S. R., Delbeke, D., Dorbala, S., Gropler, R. J., Knuuti, J., Schelbert, H. R., & Travin, M. I. (2016) · Journal of Nuclear Cardiology · doi:10.1007/s12350-016-0522-3 · Cited by 612
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · EP Europace · doi:10.1093/europace/euz246 · Cited by 423
Metadata
- Authors
- Sandoe, J. A. T., Barlow, G., Chambers, J. B., Gammage, M., Guleri, A., Howard, P., Olson, E., Perry, J. D., Prendergast, B. D., Spry, M. J., Steeds, R. P., Tayebjee, M. H., & Watkin, R.
- Venue
- Journal of Antimicrobial Chemotherapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-10-29
- Volume
- 70
- Issue
- 2
- Pages
- 325-359
- ISSN
- 0305-7453 (ISSN-L)
- 1460-2091
- OpenAlex
- W2167544256
- Cited by
- 403
- References
- 136
- FWCI
- 22.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.