CoChat

Biometric contrastive learning for data-efficient deep learning from electrocardiographic images

Open access
Sangha, Veer, Khunte, Akshay, Holste, Gregory, Mortazavi, Bobak J, Wang, Zhangyang, Oikonomou, Evangelos K, Khera, Rohan · 2024 · Journal of the American Medical Informatics Association
Cited by 31

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Objective: Artificial intelligence (AI) detects heart disease from images of electrocardiograms (ECGs). However, traditional supervised learning is limited by the need for large amounts of labeled data. We report the development of Biometric Contrastive Learning (BCL), a self-supervised pretraining approach for label-efficient deep learning on ECG images. Materials and Methods: Using pairs of ECGs from 78 288 individuals from Yale (2000-2015), we trained a convolutional neural network to identify temporally separated ECG pairs that varied in layouts from the same patient. We fine-tuned BCL-pretrained models to detect atrial fibrillation (AF), gender, and LVEF < 40%, using ECGs from 2015 to 2021. We externally tested the models in cohorts from Germany and the United States. We compared BCL with ImageNet initialization and general-purpose self-supervised contrastive learning for images (simCLR). Results: While with 100% labeled training data, BCL performed similarly to other approaches for detecting AF/Gender/LVEF < 40% with an AUROC of 0.98/0.90/0.90 in the held-out test sets, it consistently outperformed other methods with smaller proportions of labeled data, reaching equivalent performance at 50% of data. With 0.1% data, BCL achieved AUROC of 0.88/0.79/0.75, compared with 0.51/0.52/0.60 (ImageNet) and 0.61/0.53/0.49 (simCLR). In external validation, BCL outperformed other methods even at 100% labeled training data, with an AUROC of 0.88/0.88 for Gender and LVEF < 40% compared with 0.83/0.83 (ImageNet) and 0.84/0.83 (simCLR). Discussion and Conclusion: A pretraining strategy that leverages biometric signatures of different ECGs from the same patient enhances the efficiency of developing AI models for ECG images. This represents a major advance in detecting disorders from ECG images with limited labeled data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jamia/ocae002

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 31

Metadata

Authors
Sangha, V., Khunte, A., Holste, G., Mortazavi, B. J., Wang, Z., Oikonomou, E. K., & Khera, R.
Venue
Journal of the American Medical Informatics Association
Published
2024-01-24
Volume
31
Issue
4
Pages
855-865
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W4391225171
Cited by
31
References
14
FWCI
8.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biometric contrastive learning for data-efficient deep learning from electrocardiographic images. https://app.cochat.ai/papers/10.1093/jamia/ocae002
The paper
Sangha, V., Khunte, A., Holste, G., Mortazavi, B. J., Wang, Z., Oikonomou, E. K., & Khera, R. (2024). Biometric contrastive learning for data-efficient deep learning from electrocardiographic images. Journal of the American Medical Informatics Association. https://doi.org/10.1093/jamia/ocae002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.