The mechanism of acute hypoxic pulmonary vasoconstriction: the tale of two channels
The DOI matches its Crossref record.
Abstract
Hypoxia causes constriction in small pulmonary arteries and dilatation in systemic arteries. Hypoxic pulmonary vasoconstriction (HPV) is an important mechanism by which pulmonary blood flow is controlled in the fetus and by which local lung perfusion is matched to ventilation in the adult. HPV reduces the flow of desaturated blood through underventilated areas of lung. Even though many vasoactive substances have been examined as possible mediators of HPV, these appear more likely to be modulators than mediators. Hypoxic contraction has been demonstrated in single pulmonary vascular smooth muscle cells (PVSMC). The ability to sense changes in oxygen tension is observed in PVSMC and type 1 cells of the carotid body. In both cells, hypoxia has been shown to inhibit an outward potassium current, thus causing membrane depolarization and calcium entry through the voltage‐dependent calcium channels. In both cells there is evidence to suggest that changes in the redox status of the oxygen‐sensitive potassium channel or channels may control current flow, so that the channel is open when oxidized and closed when reduced. The redox status may be determined by the effects of hypoxia on mitochondrial/peroxisomal function or on the activity of an oxidase similar to NAD(P)H oxidase. More studies are needed to precisely define the individual potassium channels responsive to hypoxia and to confirm the gating mechanism. In systemic arteries hypoxia causes an increased current through ATP‐dependent potassium channels and vasodilatation, whereas in the pulmonary arteries hypoxia inhibits potassium current and causes vasoconstriction.—Weir, E. K., Archer, S. L. The mechanism of acute hypoxic pulmonary vasoconstriction: the tale of two channels. FASEB J. 9, 183–189 (1995)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PAS Domains: Internal Sensors of Oxygen, Redox Potential, and Light
Taylor, B. L., & Zhulin, I. B. (1999) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.63.2.479-506.1999 · Cited by 1,632
“Oxygen-sensitive ion channels are involved in several cardiocirculatory and respiratory responses to low oxygen levels in fetal and adult life (36, 258) and are associated with the pathophysiology of hypertension, cardiac arrhythmias, and ischemic neuronal damage (60, 115, 144, 245).”
BackgroundHypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Greish, K. (2007) · Journal of Drug Targeting · doi:10.1080/10611860701539584 · Cited by 600
Cellular Mechanism of Oxygen Sensing
López-Barneo, J., Pardal, R., & Ortega-Sáenz, P. (2001) · Annual Review of Physiology · doi:10.1146/annurev.physiol.63.1.259 · Cited by 544
Hypoxic Pulmonary Vasoconstriction
Dunham-Snary, K. J., Wu, D., Sykes, E. A., Thakrar, A., Parlow, L. R. G., Mewburn, J. D., Parlow, J. L., & Archer, S. L. (2017) · Chest · doi:10.1016/j.chest.2016.09.001 · Cited by 510
Self-citationInteractions of oxidants with vascular signaling systems
Wolin, M. S. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.6.1430 · Cited by 463
Cellular oxygen sensing by mitochondria: old questions, new insight
Chandel, N. S., & Schumacker, P. T. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.88.5.1880 · Cited by 391
Superoxide generation by complex III: From mechanistic rationales to functional consequences
Bleier, L., & Dröse, S. (2013) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/j.bbabio.2012.12.002 · Cited by 369
Oxygen Sensing, Hypoxia-Inducible Factor-1 and the Regulation of Mammalian Gene Expression
Ratcliffe, P. J., O’rourke, J. F., Maxwell, P. H., & Pugh, C. W. (1998) · Journal of Experimental Biology · doi:10.1242/jeb.201.8.1153 · Cited by 371
Mocumbi, A., Humbert, M., Saxena, A., Jing, Z.-C., Sliwa, K., Thienemann, F., Archer, S. L., & Stewart, S. (2024) · Nature Reviews Disease Primers · doi:10.1038/s41572-023-00486-7 · Cited by 370
Self-citationMcMurtry, M. S. (2005) · Journal of Clinical Investigation · doi:10.1172/jci23203 · Cited by 368
Hypoxia Triggers Subcellular Compartmental Redox Signaling in Vascular Smooth Muscle Cells
Waypa, G. B., Marks, J. D., Guzy, R., Mungai, P. T., Schriewer, J., Dokic, D., & Schumacker, P. T. (2010) · Circulation Research · doi:10.1161/circresaha.109.206334 · Cited by 358
Primary Pulmonary Hypertension: A Vascular Biology and Translational Research “Work in Progress”
Archer, S., & Rich, S. (2000) · Circulation · doi:10.1161/01.cir.102.22.2781 · Cited by 354
Self-citationArcher, S. L., Huang, J. M. C., Reeve, H. L., Hampl, V., Tolarová, S., Michelakis, E., & Weir, E. K. (1996) · Circulation Research · doi:10.1161/01.res.78.3.431 · Cited by 332
Self-citationKeeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Diversity in Mitochondrial Function Explains Differences in Vascular Oxygen Sensing
Michelakis, E. D., Hampl, V., Nsair, A., Wu, X., Harry, G., Haromy, A., Gurtu, R., & Archer, S. L. (2002) · Circulation Research · doi:10.1161/01.res.0000024689.07590.c2 · Cited by 309
Self-citationPathobiology of Pulmonary Hypertension
Rabinovitch, M. (2007) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev.pathol.2.010506.092033 · Cited by 301
Patel, A. J. (1997) · The EMBO Journal · doi:10.1093/emboj/16.22.6615 · Cited by 277
Hydrogen Sulfide in the Mammalian Cardiovascular System
Liu, Y.-H., Lu, M., Hu, L.-F., Wong, P. T.-H., Webb, G. D., & Bian, J.-S. (2012) · Antioxidants & Redox Signaling · doi:10.1089/ars.2011.4005 · Cited by 264
O 2 sensing is preserved in mice lacking the gp91 phox subunit of NADPH oxidase
Archer, S. L., Reeve, H. L., Michelakis, E., Puttagunta, L., Waite, R., Nelson, D. P., Dinauer, M. C., & Weir, E. K. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.14.7944 · Cited by 263
Self-citationWaypa, G. B., Guzy, R., Mungai, P. T., Mack, M. M., Marks, J. D., Roe, M. W., & Schumacker, P. T. (2006) · Circulation Research · doi:10.1161/01.res.0000247068.75808.3f · Cited by 191
Hemoglobin, nitric oxide and molecular mechanisms of hypoxic vasodilation
Allen, B. W., Stamler, J. S., & Piantadosi, C. A. (2009) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2009.08.002 · Cited by 165
Hydrogen Sulfide as an Oxygen Sensor
Olson, K. R. (2015) · Antioxidants & Redox Signaling · doi:10.1089/ars.2014.5930 · Cited by 144
Regulation of oxygen sensing by ion channels
López-Barneo, J., del Toro, R., Levitsky, K. L., Chiara, M. D., & Ortega-Sáenz, P. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00929.2003 · Cited by 106
Hydrogen sulfide as an oxygen sensor
Olson, K. R. (2013) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm-2012-0551 · Cited by 54
Calcium, mitochondria and oxygen sensing in the pulmonary circulation
Ward, J. P. T., Snetkov, V. A., & Aaronson, P. I. (2004) · Cell Calcium · doi:10.1016/j.ceca.2004.02.017 · Cited by 45
Metadata
- Authors
- Weir, E. K., & Archer, S. L.
- Venue
- The FASEB Journal
- Publisher
- Wiley
- Published
- 1995-02
- Volume
- 9
- Issue
- 2
- Pages
- 183-189
- ISSN
- 0892-6638 (ISSN-L)
- 1530-6860
- OpenAlex
- W1951323910
- Cited by
- 465
- References
- 0
- FWCI
- 22.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.