Pulse Oximetry
Open accessThe DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations
Chan, E. D., Chan, M. M., & Chan, M. M. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.02.004 · Cited by 710
The internet of things in healthcare: An overview
YIN, Y., Zeng, Y., Chen, X., & Fan, Y. (2016) · Journal of Industrial Information Integration · doi:10.1016/j.jii.2016.03.004 · Cited by 589
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
General Anesthesia and Altered States of Arousal: A Systems Neuroscience Analysis
Brown, E. N., Purdon, P. L., & Van Dort, C. J. (2011) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-060909-153200 · Cited by 539
Pulse oximetry: Principles and limitations
Sinex, J. E. (1999) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(99)90019-0 · Cited by 481
Hemoglobin Variants: Biochemical Properties and Clinical Correlates
Thom, C. S., Dickson, C. F., Gell, D. A., & Weiss, M. J. (2013) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a011858 · Cited by 336
“Pulse oximetry is a noninvasive spectrophotometric test that measures absorbance ratios at specific wavelengths for oxygenated (660 nm) and deoxygenated (940 nm) blood (Tremper and Barker 1989).”
BackgroundHypoxemia and Arterial Hypotension at the Accident Scene in Head Injury
Stocchetti, N., Furlan, A., & Volta, F. (1996) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199605000-00014 · Cited by 328
Jubran, A., & Tobin, M. J. (1990) · Chest · doi:10.1378/chest.97.6.1420 · Cited by 296
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Recent Progress of Flexible Image Sensors for Biomedical Applications
Yokota, T., Fukuda, K., & Someya, T. (2021) · Advanced Materials · doi:10.1002/adma.202004416 · Cited by 229
Sedation for the Pediatric Patient: A Review
Coté, C. J. (1994) · Pediatric Clinics of North America · doi:10.1016/s0031-3955(16)38690-4 · Cited by 225
Mechanical Ventilation Beyond the Intensive Care Unit
Make, B. J., Hill, N. S., Goldberg, A. I., Bach, J. R., Criner, G. J., Dunne, P. E., Gilmartin, M. E., Heffner, J. E., Kacmarek, R., Keens, T. G., et al. (1998) · Chest · doi:10.1378/chest.113.5_supplement.289s · Cited by 221
Methemoglobinemia: a review and recommendations for management
Cortazzo, J. A., & Lichtman, A. D. (2014) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2013.02.005 · Cited by 180
The Effect of Motion on Pulse Oximetry and Its Clinical Significance
Petterson, M. T., Begnoche, V. L., & Graybeal, J. M. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278134.47777.a5 · Cited by 176
Potential errors in pulse oximetry: I. Pulse oximeter evaluation*
RALSTON, A. C., WEBB, R. K., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09410.x · Cited by 166
A review of the effect of skin pigmentation on pulse oximeter accuracy
Al-Halawani, R., Charlton, P. H., Qassem, M., & Kyriacou, P. A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acd51a · Cited by 119
Nilsson, L., Goscinski, T., Kalman, S., Lindberg, L. ‐., & Johansson, A. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01375.x · Cited by 88
Pulse oximetry in sickle cell anemia
Fitzgerald, R. K., & Johnson, A. (2001) · Critical Care Medicine · doi:10.1097/00003246-200109000-00025 · Cited by 55
“Pulse oximetry oxygen saturation (SpO2) is then calculated from this ratio using experimental data from human volunteers (12, 13).”
MethodCentral venous pulsations associated with a falsely low oxygen saturation measured by pulse oximetry
Sami, H. M., Kleinman, B. S., & Lonchyna, V. A. (1991) · Journal of Clinical Monitoring · doi:10.1007/bf01619351 · Cited by 36
Age and gender do not influence the ability to detect respiration by photoplethysmography
Nilsson, L., Goscinski, T., Johansson, A., Lindberg, L.-G., & Kalman, S. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9050-z · Cited by 26
Haxha, S., Nwibor, C., Ali, M., Sakel, M., Saunders, K., Dyo, V., & Nabakooza, S. (2024) · Sensors · doi:10.3390/s24113301 · Cited by 12
“Consequently, pulse oximeters utilise two wavelengths: NIR at 940 nm and red light at 660 nm [2,33,34].”
BackgroundNijland, R., Jongsma, H. W., Verbruggen, I. M., & Nijhuis, J. G. (1996) · Journal of Clinical Monitoring · doi:10.1007/bf00857643 · Cited by 8
Metadata
- Authors
- Tremper, K. K., & Barker, S. J.
- Venue
- Anesthesiology
- Published
- 1989-01-01
- Volume
- 70
- Issue
- 1
- Pages
- 98-108
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W4256536061
- Cited by
- 435
- References
- 0
- FWCI
- 34.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.