A randomized, controlled trial of protocol-directed versus physician-directed weaning from mechanical ventilation
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare a practice of protocol-directed weaning from mechanical ventilation implemented by nurses and respiratory therapists with traditional physician-directed weaning. DESIGN: Randomized, controlled trial. SETTING: Medical and surgical intensive care units in two university-affiliated teaching hospitals. PATIENTS: Patients requiring mechanical ventilation (n = 357). INTERVENTIONS: Patients were randomly assigned to receive either protocol-directed (n = 179) or physician-directed (n = 178) weaning from mechanical ventilation. MEASUREMENTS AND MAIN RESULTS: The primary outcome measure was the duration of mechanical ventilation from tracheal intubation until discontinuation of mechanical ventilation. Other outcome measures included need for reintubation, length of hospital stay, hospital mortality rate, and hospital costs. The median duration of mechanical ventilation was 35 hrs for the protocol-directed group (first quartile 15 hrs; third quartile 114 hrs) compared with 44 hrs for the physician-directed group (first quartile 21 hrs; third quartile 209 hrs). Kaplan-Meier analysis demonstrated that patients randomized to protocol-directed weaning had significantly shorter durations of mechanical ventilation compared with patients randomized to physician-directed weaning (chi 2 = 3.62, p = .057, log-rank test; chi 2 = 5.12, p = .024, Wilcoxon test). Cox proportional-hazards regression analysis, adjusting for other covariates, showed that the rate of successful weaning was significantly greater for patients receiving protocol-directed weaning compared with patients receiving physician-directed weaning (risk ratio 1.31; 95% confidence interval 1.15 to 1.50; p = .039). The hospital mortality rates for the two treatment groups were similar (protocol-directed 22.3% vs. physician-directed 23.6%; p = .779). Hospital cost savings for patients in the protocol-directed group were $42,960 compared with hospital costs for patients in the physician-directed group. CONCLUSION: Protocol-guided weaning of mechanical ventilation, as performed by nurses and respiratory therapists, is safe and led to extubation more rapidly than physician-directed weaning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664
APACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376
Bernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746
Journal of the Royal Statistical Society (B)
Fildes, R. (1993) · International Journal of Forecasting · doi:10.1016/0169-2070(93)90088-5 · Cited by 3,437
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Brochard, L., Rauss, A., Benito, S., Conti, G., Mancebo, J., Rekik, N., Gasparetto, A., & Lemaire, F. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.4.7921460 · Cited by 1,122
Morris, A. H., Wallace, C. J., Menlove, R. L., Clemmer, T. P., Orme, J. F., Weaver, L. K., Dean, N. C., Thomas, F., East, T. D., Pace, N. L., et al. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.2.8306022 · Cited by 968
The Medical Outcomes Study: An Application of Methods for Monitoring the Results of Medical Care
Tarlov, A. R. (1989) · JAMA · doi:10.1001/jama.1989.03430070073033 · Cited by 877
Ventilator-associated pneumonia. A multivariate analysis
Kollef, M. H. (1993) · JAMA · doi:10.1001/jama.270.16.1965 · Cited by 739
Self-citationKollef, M. H., Bock, K. R., Richards, R. D., & Hearns, M. L. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-122-10-199505150-00002 · Cited by 210
Self-citationMechanical Ventilation with or without 7-Day Circuit Changes: A Randomized Controlled Trial
Kollef, M. H., Shapiro, S. D., Fraser, V. J., Silver, P., Murphy, D. M., Trovillion, E., Hearns, M. L., Richards, R. D., Cracchilo, L., & Hossin, L. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-123-3-199508010-00002 · Cited by 184
Self-citationThorens, J.-B., Kaelin, R. M., Jolliet, P., & Chevrolet, J.-C. (1995) · Critical Care Medicine · doi:10.1097/00003246-199511000-00004 · Cited by 168
Weaning from Mechanical Ventilation: Physician-Directed vs a Respiratory-Therapist-Directed Protocol
Wood, G., MacLeod, B., & Moffatt, S. D. (1995) · Respiratory Care · doi:10.1177/194336549504000302 · Cited by 112
Rotello, L. C., Warren, J., Jastremski, M. S., & Milewski, A. M. (1992) · CHEST Journal · doi:10.1378/chest.102.6.1833 · Cited by 36
Weaning from Ventilatory Support
Weinberger, S. E., & Weiss, J. W. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320609 · Cited by 30
Cited by
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Girard, T. D., Kress, J. P., Fuchs, B. D., Thomason, J. W., Schweickert, W. D., Pun, B. T., Taichman, D. B., Dunn, J. G., Pohlman, A. S., Kinniry, P. A., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60105-1 · Cited by 2,055
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation
Brook, A. D., Ahrens, T. S., Schaiff, R., Prentice, D., Sherman, G., Shannon, W., & Kollef, M. H. (1999) · Critical Care Medicine · doi:10.1097/00003246-199912000-00001 · Cited by 1,013
Self-citationThe Use of Continuous IV Sedation Is Associated With Prolongation of Mechanical Ventilation
Kollef, M. H., Levy, N. T., Ahrens, T. S., Schaiff, R., Prentice, D., & Sherman, G. (1998) · Chest · doi:10.1378/chest.114.2.541 · Cited by 916
Self-citation
Metadata
- Authors
- Kollef, M. H., Shapiro, S. D., Silver, P., St. John, R. E., Prentice, D., Sauer, S., Ahrens, T. S., Shannon, W., & Baker-Clinkscale, D.
- Venue
- Critical Care Medicine
- Published
- 1997-04
- Volume
- 25
- Issue
- 4
- Pages
- 567-574
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2032352662
- Cited by
- 827
- References
- 18
- FWCI
- 27.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.