CoChat

Detection of ventilatory threshold using near infrared spectroscopy in men and women

BHAMBHANI, YAGESH N., BUCKLEY, SHELLEY M., SUSAKI, TOSHIO · 1997 · Medicine & Science in Sports & Exercise

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

The onset of anaerobic (lactate) metabolism during incremental exercise, which may be a result of an imbalance between tissue oxygen supply and demand, has been associated with the gas exchange ventilatory threshold (VT). This study was designed to examine whether near infrared spectroscopy (NIRS) could be used to detect the VT in healthy subjects. Twenty-one men and 19 women completed incremental cycle ergometry during which NIRS measurements were obtained from the right vastus lateralis and gas exchange measurements were monitored simultaneously using a metabolic cart. The VT was identified from the metabolic data by the V-slope method and from NIRS data as the intensity at which tissue absorbency crossed the resting baseline value observed immediately prior to the initiation of exercise. Pearson correlations for the relative oxygen uptake and power output observed for the two methods of detecting VT were 0.90 and 0.88, respectively, in men and 0.89 and 0.86, respectively, in women (P 0.05). No significant (P > 0.05) gender differences were observed in muscle oxygenation values at the VT, 32% in men and 38% in women. These results validate the use of NIRS as an alternate noninvasive method for detecting VT during cycle exercise in healthy subjects.

Overview

Integrity signals

Registry

Crossref · 10.1097/00005768-199703000-00017

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 18 references

Research works printed but not linked: 4

  1. Brooks, 1985, Med Sci Sports Exerc, 17, 22
  2. Davis, 1985, Med Sci Sports Exerc, 17, 6
  3. Miyashita, 1981, J Sports Med Phys Fitness, 21, 209
  4. Wasserman, 1991, NIPS, 6, 29

Cited by

Metadata

Authors
BHAMBHANI, Y. N., BUCKLEY, S. M., & SUSAKI, T.
Affiliations
  • University of Alberta (CA)
  • Kanazawa University (JP)
Venue
Medicine & Science in Sports & Exercise
Published
1997-03
Volume
29
Issue
3
Pages
402-409
ISSN
0195-9131 (ISSN-L)
OpenAlex
W1990494357
Cited by
89
References
18
Citations by year
2026: 3 · 2025: 1 · 2023: 2 · 2022: 5 · 2021: 1 · 2020: 1 · 2019: 4 · 2018: 3 · 2017: 2 · 2016: 4 · 2015: 3 · 2014: 1 · 2013: 2 · 2012: 5
FWCI
6.22
Type
journal article
Language
en
Open access
closed
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
Keywords
ventilatory threshold, near-infrared spectroscopy, muscle oxygenation, incremental exercise, cycle ergometry, gas exchange, anaerobic metabolism, lactate threshold, sex differences, vastus lateralis, oxygen consumption
MeSH terms
Absorption, Adolescent, Adult, Exercise Test, Physical Exertion, Female, Hemoglobins, Humans, Lactates, Male, Methemoglobin, Oxygen Consumption, Oxyhemoglobins, Pulmonary Gas Exchange, Sex Factors, Signal Processing, Computer-Assisted, Reproducibility of Results, Anaerobic Threshold, Ergometry, Muscle, Skeletal, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.