The Effect of Cage Stiffness on the Rate of Lumbar Interbody Fusion: An In Vivo Model Using Poly(L-Lactic Acid) and Titanium Cages
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: A goat interbody fusion model using poly-(L-lactic acid) and titanium cages was designed to evaluate the effect of cage stiffness on lumbar interbody fusion. OBJECTIVE: To investigate the effect of cage stiffness on the rate of interbody fusion. SUMMARY OF BACKGROUND DATA: Various types of cages considerably exceed the stiffness of vertebral bone, which ultimately may lead to postoperative complications. To avoid these complications, poly-(L-lactic acid) cages with limited stiffness have been designed. The mechanical integrity of the cages remains intact for at least 6 months. METHODS: Interbody fusions were performed at L3-L4 of 15 Dutch milk goats, and one of three cages was randomly implanted: 1) a titanium cage (n = 3), 2) a stiff poly-(L-lactic acid) cage (n = 6), or 3) a flexible poly-(L-lactic acid) cage (n = 6). Interbody fusion was assessed radiographically by three independent observers 3 and 6 months after surgery. RESULTS: At 3 months, all the poly-(L-lactic acid) specimens showed ingrowth of new bone, but with radiolucency in the fusion mass. At 6 months, solid arthrodesis was observed in four of six poly-(L-lactic acid) specimens, advanced ingrowth in one specimen, and infection in one specimen. Titanium cages showed ingrowth of bone, but with radiolucency in the fusion mass. Interbody fusion using poly-(L-lactic acid) cages showed a significantly higher rate statistically (P = 0.016) and more complete fusion than titanium cages of the same design. CONCLUSIONS: The reduced stiffness of poly-(L-lactic acid) cages showed enhanced interbody fusion, as compared with titanium cages after 6 months. Bioabsorbable poly-(L-lactic acid) cages thus may be a viable alternative to current interbody cage devices, thereby avoiding the concomitant problems related to their excessive stiffness. However, the bioabsorbability of the poly-(L-lactic acid) cages awaits investigation in a long-term study currently underway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148 · cited 1×
“94).(16) In the current study, a radiographic score of 1 was defined as ingrowth of bone with the cage securely fixed to vertebral bone above and below, but with a radiolucent discontinuity in the fusion mass.”
BackgroundA Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398 · cited 1×
“The intra- and interobserver reliability of the radiographic score was analyzed using Cohen’s kappa.(6) The difference in the amount of subsidence was tested with Student’s t tests, and the difference in the rate of interbody fusion between the treatment groups was tested with the Mann-Whitney U test and judged to be…”
MethodKuslich, S. D., Ulstrom, C. L., Griffith, S. L., Ahern, J. W., & Dowdle, J. D. (1998) · Spine · doi:10.1097/00007632-199806010-00019 · Cited by 508 · cited 2×
“Fusion rates up to 96% have been reported with the use of stand-alone cages, and up to 100% with the use of additional posterior instrumentation after 2 years of follow-up evaluation.(1,4,15,20,23) Despite these initial, favorable fusion outcomes and attributed clinical effectiveness,(15) the long-term effects of cage…”
BackgroundThreaded Titanium Cages for Lumbar Interbody Fusions
Ray, C. D. (1997) · Spine · doi:10.1097/00007632-199703150-00019 · Cited by 452 · cited 2×
“In addition, an optimal environment for successful arthrodesis is created by using the cage to separate the mechanical and biologic functions of the bone graft.(17,22,23,33) However, various cage devices, especially metallic and titanium cages, exceed the stiffness of the spinal motion segment and the vertebral bone.”
BackgroundMethodBrantigan, J. W., & Steffee, A. D. (1993) · Spine · doi:10.1097/00007632-199310001-00030 · Cited by 444
Brantigan, J. W., & Steffee, A. D. (1993) · Lumbar Fusion and Stabilization · doi:10.1007/978-4-431-68234-9_41 · Cited by 424 · cited 3×
“, radiographic signs outside the cage are important parameters as signs of non fusion).(4) As mentioned, the authors focused on intracage bone formation, so the radiographic score of Brantigan and Steffee was not used.”
BackgroundCurrent Concepts Review - Interbody Fusion Cages in Reconstructive Operations on the Spine*
MCAFEE, P. C. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199906000-00014 · Cited by 306 · cited 2×
“In addition, an optimal environment for successful arthrodesis is created by using the cage to separate the mechanical and biologic functions of the bone graft.(17,22,23,33) However, various cage devices, especially metallic and titanium cages, exceed the stiffness of the spinal motion segment and the vertebral bone.”
BackgroundMethodRegan, J. J., Yuan, H., & McAfee, P. C. (1999) · Spine · doi:10.1097/00007632-199902150-00023 · Cited by 245 · cited 1×
“These complications still present a problem in lumbar interbody fusion.(7,15,19,24,25,31,33) To explore the potential benefits of a bioabsorbable cage with less stiffness than current cage devices, poly(L-lactic acid) (PLLA) cages have been designed with a modulus having an elasticity of 4.”
BackgroundWeiner, B. K., & Fraser, R. D. (1998) · Spine · doi:10.1097/00007632-199803010-00020 · Cited by 242 · cited 3×
“In addition, an optimal environment for successful arthrodesis is created by using the cage to separate the mechanical and biologic functions of the bone graft.(17,22,23,33) However, various cage devices, especially metallic and titanium cages, exceed the stiffness of the spinal motion segment and the vertebral bone.”
BackgroundMethodMcAfee, P. C., Regan, J. J., Geis, W. P., & Fedder, I. L. (1998) · Spine · doi:10.1097/00007632-199807010-00009 · Cited by 232 · cited 1×
“Fusion rates up to 96% have been reported with the use of stand-alone cages, and up to 100% with the use of additional posterior instrumentation after 2 years of follow-up evaluation.(1,4,15,20,23) Despite these initial, favorable fusion outcomes and attributed clinical effectiveness,(15) the long-term effects of cage…”
BackgroundBrantigan, J. W., McAfee, P. C., Cunningham, B. W., Wang, H., & Orbegoso, C. M. (1994) · Spine · doi:10.1097/00007632-199407000-00002 · Cited by 182
Cunningham, B. W., Kanayama, M., Parker, L. M., Weis, J. C., Sefter, J. C., Fedder, I. L., & McAfee, P. C. (1999) · Spine · doi:10.1097/00007632-199903150-00002 · Cited by 163
Posterior lumbar interbody fusion with cages: an independent review of 71 cases
Agazzi, S., Reverdin, A., & May, D. (1999) · Journal of Neurosurgery: Spine · doi:10.3171/spi.1999.91.2.0186 · Cited by 161 · cited 1×
“Fusion rates up to 96% have been reported with the use of stand-alone cages, and up to 100% with the use of additional posterior instrumentation after 2 years of follow-up evaluation.(1,4,15,20,23) Despite these initial, favorable fusion outcomes and attributed clinical effectiveness,(15) the long-term effects of cage…”
BackgroundKanayama, M., Cunningham, B. W., Haggerty, C. J., Abumi, K., Kaneda, K., & McAfee, P. C. (2000) · Journal of Neurosurgery Spine · doi:10.3171/spi.2000.93.2.0259 · Cited by 152
Revision Strategies for Salvaging or Improving Failed Cylindrical Cages
McAfee, P. C., Cunningham, B. W., Lee, G. A., Orbegoso, C. M., Haggerty, C. J., Fedder, I. L., & Griffith, S. L. (1999) · Spine · doi:10.1097/00007632-199910150-00015 · Cited by 112 · cited 2×
“Concerns may arise because postoperative complications leading to revision procedures have been reported recently.(19,30,31) In keeping with these experiences, an increase in revision procedures for failed fusion cages may be expected because the number of implanted cage devices still shows a progressive increase, and…”
BackgroundDistractive Properties of a Threaded Interbody Fusion Device
Sandhu, H. S., Turner, S., Kabo, J. M., Kanim, L. E. A., Liu, D., Nourparvar, A., Delamarter, R. B., & Dawson, E. G. (1996) · Spine · doi:10.1097/00007632-199605150-00013 · Cited by 107
Anterior lumbar fusion: Results, assessment techniques and prognostic factors
Greenough, C. G., Taylor, L. J., & Fraser, R. D. (1994) · European Spine Journal · doi:10.1007/bf02221598 · Cited by 97
Regan, J. J., Aronoff, R. J., Ohnmeiss, D. D., & Sengupta, D. K. (1999) · Spine · doi:10.1097/00007632-199910150-00018 · Cited by 94 · cited 1×
“These complications still present a problem in lumbar interbody fusion.(7,15,19,24,25,31,33) To explore the potential benefits of a bioabsorbable cage with less stiffness than current cage devices, poly(L-lactic acid) (PLLA) cages have been designed with a modulus having an elasticity of 4.”
BackgroundFailure of a Carbon Fiber Implant
Tullberg, T. (1998) · Spine · doi:10.1097/00007632-199808150-00016 · Cited by 76 · cited 2×
“Concerns may arise because postoperative complications leading to revision procedures have been reported recently.(19,30,31) In keeping with these experiences, an increase in revision procedures for failed fusion cages may be expected because the number of implanted cage devices still shows a progressive increase, and…”
Background
Cited by
Navarro, M., Michiardi, A., Castaño, O., & Planell, J. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0151 · Cited by 1,513
Stem Cells from Adipose Tissue Allow Challenging New Concepts for Regenerative Medicine
Helder, M. N., Knippenberg, M., Klein-Nulend, J., & Wuisman, P. I. J. M. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0165 · Cited by 207
Self-citationLin, C., Wirtz, T., LaMarca, F., & Hollister, S. J. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31231 · Cited by 198
Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface
Walsh, W. R., Bertollo, N., Christou, C., Schaffner, D., & Mobbs, R. J. (2015) · The Spine Journal · doi:10.1016/j.spinee.2014.12.018 · Cited by 197
Wu, S., Li, Y., Zhang, Y., Li, X., Yuan, C., Hao, Y., Zhang, Z., & Guo, Z. (2013) · Artificial Organs · doi:10.1111/aor.12153 · Cited by 181
Metadata
- Authors
- van Dijk, M., Smit, T. H., Sugihara, S., Burger, E. H., & Wuisman, P. I.
- Venue
- Spine
- Published
- 2002-04
- Volume
- 27
- Issue
- 7
- Pages
- 682-688
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2054121842
- Cited by
- 165
- References
- 19
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.