Ventilation of patients with acute lung injury and acute respiratory distress syndrome: Has new evidence changed clinical practice?*
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: A recent randomized trial of mechanical ventilation in acute lung injury (ALI)/adult respiratory distress syndrome (ARDS) demonstrated a 22% relative reduction in mortality rate using 6 mL/kg predicted body weight tidal volume vs. 12 mL/kg predicted body weight tidal volume. We determined whether publication of these findings changed clinical practice. DESIGN: Retrospective cohort, 12 months before (Pre) and 12 months after publication (Post) of a randomized trial supporting the use of a 6 mL/kg predicted body weight tidal volume strategy. SETTING: Three tertiary care hospitals in northern New England. PATIENTS: From a sample of 943 patients receiving prolonged mechanical ventilation between 1998 and 1999 (Pre) and between 2000 and 2001 (Post), 300 patients meeting the American-European Consensus Conference definition of ALI or ARDS were selected for analysis. INTERVENTIONS: The tidal volume, tidal volume/kg predicted body weight, and proportion receiving tidal volume/kg > or =6 mL/kg and < or =12 mL/kg predicted body weight were recorded at noon the first day after the diagnosis of ALI or ARDS was established. MEASUREMENTS AND MAIN RESULTS: Pre and Post mean tidal volume (+/- sd) size and tidal volume size/kg predicted body weight were 759 +/- 158 mL (median 750 mL) vs. 639 +/- 138 mL (median 600 mL, p <.001) and 12.3 +/- 2.7 mL/kg (median 11.7 mL/kg) vs. 10.6 +/- 2.4 mL/kg (median 10.7 mL/kg, p <.001) respectively. Pre and Post plateau pressures and peak airway pressures were similar. CONCLUSION: Publication of a trial demonstrating large mortality reductions using small tidal volume was associated with significant reductions in tidal volume delivered to patients with ALI/ARDS. However, wide variation in practice persists, and the proportion of patients receiving tidal volumes within recommended limits (< or =8 mL/kg) remains modest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Bernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746 · cited 1×
“2 Predicted weight, kg 63 (12) 61 (11) .”
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654
Sandham, J. D., Hull, R. D., Brant, R. F., Knox, L., Pineo, G. F., Doig, C. J., Laporta, D. P., Viner, S., Passerini, L., Devitt, H., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021108 · Cited by 1,529
Stewart, T. E., Meade, M. O., Cook, D. J., Granton, J. T., Hodder, R. V., Lapinsky, S. E., Mazer, C. D., McLean, R. F., Rogovein, T. S., Schouten, B. D., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380603 · Cited by 888
BROCHARD, L., ROUDOT-THORAVAL, F., ROUPIE, E., DELCLAUX, C., CHASTRE, J., FERNANDEZ-MONDÉJAR, E., CLÉMENTI, E., MANCEBO, J., FACTOR, P., MATAMIS, D., et al. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9801044 · Cited by 800
Brower, R. G., Shanholtz, C. B., Fessler, H. E., Shade, D. M., White, P., Wiener, C. M., Teeter, J. G., Dodd-o, J. M., Almog, Y., & Piantadosi, S. (1999) · Critical Care Medicine · doi:10.1097/00003246-199908000-00015 · Cited by 575
Change in the Quality of Care Delivered to Medicare Beneficiaries, 1998-1999 to 2000-2001
Jencks, S. F., Huff, E. D., & Cuerdon, T. (2003) · JAMA · doi:10.1001/jama.289.3.305 · Cited by 546
Physician-Related Barriers to the Effective Management of Uncontrolled Hypertension
Oliveria, S. A., Lapuerta, P., McCarthy, B. D., L'Italien, G. J., Berlowitz, D. R., & Asch, S. M. (2002) · Archives of Internal Medicine · doi:10.1001/archinte.162.4.413 · Cited by 479
Eichacker, P. Q., Gerstenberger, E. P., Banks, S. M., Cui, X., & Natanson, C. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200208-956oc · Cited by 423 · cited 3×
“(23) suggested that a VT of 8–9 mL/kg was “routinely used” at the time the ARDS Network study was undertaken.”
BackgroundMethod
Cited by
Acute lung injury and the acute respiratory distress syndrome: a clinical review
Wheeler, A. P., & Bernard, G. R. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60604-7 · Cited by 904
Rice, T. W., Wheeler, A. P., Bernard, G. R., Hayden, D. L., Schoenfeld, D. A., & Ware, L. B. (2007) · Chest · doi:10.1378/chest.07-0617 · Cited by 820
de Jonge, E., Peelen, L., Keijzers, P. J., Joore, H., de Lange, D., van der Voort, P. H., Bosman, R. J., de Waal, R. A., Wesselink, R., & de Keizer, N. F. (2008) · Critical Care · doi:10.1186/cc7150 · Cited by 425
High Tidal Volume and Positive Fluid Balance Are Associated With Worse Outcome in Acute Lung Injury
Sakr, Y., Vincent, J.-L., Reinhart, K., Groeneveld, J., Michalopoulos, A., Sprung, C. L., Artigas, A., & Ranieri, V. M. (2005) · Chest · doi:10.1378/chest.128.5.3098 · Cited by 405
Needham, D. M., Colantuoni, E., Mendez-Tellez, P. A., Dinglas, V. D., Sevransky, J. E., Dennison Himmelfarb, C. R., Desai, S. V., Shanholtz, C., Brower, R. G., & Pronovost, P. J. (2012) · BMJ · doi:10.1136/bmj.e2124 · Cited by 353
Implementation and outcomes of the Multiple Urgent Sepsis Therapies (MUST) protocol*
Shapiro, N. I., Howell, M. D., Talmor, D., Lahey, D., Ngo, L., Buras, J., Wolfe, R. E., Weiss, J. W., & Lisbon, A. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000206104.18647.a8 · Cited by 348
Incidence and clinical effects of intra-abdominal hypertension in critically ill patients
Vidal, M. G., Weisser, J. R., Gonzalez, F., Toro, M. A., Loudet, C., Balasini, C., Canales, H., Reina, R., & Estenssoro, E. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31817c7a4d · Cited by 305
Dahlem, P., & Randolph, A. G. (2015) · Pediatric and Neonatal Mechanical Ventilation · doi:10.1007/978-3-642-01219-8_49 · Cited by 304
Needham, D. M., Yang, T., Dinglas, V. D., Mendez-Tellez, P. A., Shanholtz, C., Sevransky, J. E., Brower, R. G., Pronovost, P. J., & Colantuoni, E. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201409-1598oc · Cited by 255
Karlsson, S., Varpula, M., Ruokonen, E., Pettilä, V., Parviainen, I., Ala-Kokko, T. I., Kolho, E., & Rintala, E. M. (2007) · Intensive Care Medicine · doi:10.1007/s00134-006-0504-z · Cited by 249
“to ARDSnet recommendations was poor and comparable with other studies [9, 10].”
BackgroundResultFerguson, N. D., Frutos-Vivar, F., Esteban, A., Fernández-Segoviano, P., Aramburu, J. A., Nájera, L., & Stewart, T. E. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000181529.08630.49 · Cited by 249
Wolthuis, E. K., Vlaar, A. P., Choi, G., Roelofs, J. J., Juffermans, N. P., & Schultz, M. J. (2009) · Critical Care · doi:10.1186/cc7688 · Cited by 248
“tion with the use of LVT is underused in patients with acute lung injury (ALI)/adult respiratory distress syndrome (ARDS) [17] and patients at risk for ALI/ARDS [18], in the clinical arena VT have declined gradually over the past 10 years [19,20].”
Ventilatory Management of Acute Lung Injury and Acute Respiratory Distress Syndrome
Fan, E. (2005) · JAMA · doi:10.1001/jama.294.22.2889 · Cited by 242
Sebat, F., Musthafa, A. A., Johnson, D., Kramer, A. A., Shoffner, D., Eliason, M., Henry, K., & Spurlock, B. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000287593.54658.89 · Cited by 200
Overview of ventilator-induced lung injury mechanisms
Lionetti, V., Recchia, F. A., & Marco Ranieri, V. (2005) · Current Opinion in Critical Care · doi:10.1097/00075198-200502000-00013 · Cited by 188
Kalhan, R., Mikkelsen, M., Dedhiya, P., Christie, J., Gaughan, C., Lanken, P. N., Finkel, B., Gallop, R., & Fuchs, B. D. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000198328.83571.4a · Cited by 187
“performed a retrospective chart review of ALI/ARDS patients 12 months before and 12 months after publication of the ARDSnet study (1) and found that mean tidal volumes decreased slightly for patients after the study’s publication; the proportion of patients ventilated with a tidal volume 8 mL/kg PBW was only 16% in th…”
BackgroundMethodAzevedo, L. C., Park, M., Salluh, J. I., Rea-Neto, A., Souza-Dantas, V. C., Varaschin, P., Oliveira, M. C., Tierno, P. F. G., dal-Pizzol, F., Silva, U. V., et al. (2013) · Critical Care · doi:10.1186/cc12594 · Cited by 182
“Several observational studies demonstrated the lack of adherence to this strategy [9,30] and our study confirms these findings.”
ResultMechanical Ventilation in ARDS
Girard, T. D., & Bernard, G. R. (2007) · Chest · doi:10.1378/chest.06-1515 · Cited by 174
Incidence and prognostic value of right ventricular failure in acute respiratory distress syndrome
Osman, D., Monnet, X., Castelain, V., Anguel, N., Warszawski, J., Teboul, J.-L., Richard, C., & for the French Pulmonary Artery Catheter Study Group (2009) · Intensive Care Medicine · doi:10.1007/s00134-008-1307-1 · Cited by 162
“same range than the values of tidal volume reported in recent clinical practice registries [23, 24 ], although it was higher than the value of 6 mL kg -1 reported in the large”
ResultPractice and perception—A nationwide survey of therapy habits in sepsis*
Brunkhorst, F. M., Engel, C., Ragaller, M., Welte, T., Rossaint, R., Gerlach, H., Mayer, K., John, S., Stuber, F., Weiler, N., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318186b6f3 · Cited by 108
Effects of a Clinical Trial on Mechanical Ventilation Practices in Patients with Acute Lung Injury
Checkley, W., Brower, R., Korpak, A., & Thompson, B. T. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200709-1424oc · Cited by 104
“Earlier reports found only a modest change in physician practice in the 2-year period after publication of the tidal volume trial (7, 8).”
BackgroundWhy do we fail to deliver evidence-based practice in critical care medicine?
Weiss, C. H. (2017) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000436 · Cited by 37
Metadata
- Authors
- Young, M. P., Manning, H. L., Wilson, D. L., Mette, S. A., Riker, R. R., Leiter, J. C., Liu, S. K., Bates, J. T., & Parsons, P. E.
- Venue
- Critical Care Medicine
- Published
- 2004-06
- Volume
- 32
- Issue
- 6
- Pages
- 1260-1265
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1991696816
- Cited by
- 189
- References
- 20
- FWCI
- 15.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.