Implant Materials Generate Different Peri-implant Inflammatory Factors: Poly-ether-ether-ketone Promotes Fibrosis and Microtextured Titanium Promotes Osteogenic Factors
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: An in vitro study examining factors produced by human mesenchymal stem cells on spine implant materials. OBJECTIVE: The aim of this study was to examine whether the inflammatory microenvironment generated by cells on titanium-aluminum-vanadium (Ti-alloy, TiAlV) surfaces is affected by surface microtexture and whether it differs from that generated on poly-ether-ether-ketone (PEEK). SUMMARY OF BACKGROUND DATA: Histologically, implants fabricated from PEEK have a fibrous connective tissue surface interface whereas Ti-alloy implants demonstrate close approximation with surrounding bone. Ti-alloy surfaces with complex micron/submicron scale roughness promote osteoblastic differentiation and foster a specific cellular environment that favors bone formation whereas PEEK favors fibrous tissue formation. METHODS: Human mesenchymal stem cells were cultured on tissue culture polystyrene, PEEK, smooth TiAlV, or macro-/micro-/nano-textured rough TiAlV (mmnTiAlV) disks. Osteoblastic differentiation and secreted inflammatory interleukins were assessed after 7 days. Fold changes in mRNAs for inflammation, necrosis, DNA damage, or apoptosis with respect to tissue culture polystyrene were measured by low-density polymerase chain reaction array. Data were analyzed by analysis of variance, followed by Bonferroni's correction of Student's t-test. RESULTS: Cells on PEEK upregulated mRNAs for chemokine ligand-2, interleukin (IL) 1β, IL6, IL8, and tumor necrosis factor. Cells grown on the mmnTiAlV had an 8-fold reduction in mRNAs for toll-like receptor-4. Cells grown on mmnTiAlV had reduced levels of proinflammatory interleukins. Cells on PEEK had higher mRNAs for factors strongly associated with cell death/apoptosis, whereas cells on mmnTiAlV exhibited reduced cytokine factor levels. All results were significant (P < 0.05). CONCLUSION: These results suggest that fibrous tissue around PEEK implants may be due to several factors: reduced osteoblastic differentiation of progenitor cells and production of an inflammatory environment that favors cell death via apoptosis and necrosis. Ti alloy surfaces with complex macro/micro/nanoscale roughness promote osteoblastic differentiation and foster a specific cellular environment that favors bone formation. LEVEL OF EVIDENCE: N/A.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PEEK biomaterials in trauma, orthopedic, and spinal implants
Kurtz, S. M., & Devine, J. N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.013 · Cited by 2,388
Franz, S., Rammelt, S., Scharnweber, D., & Simon, J. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.078 · Cited by 1,391
Macrophages in skin injury and repair
Delavary, B. M., van der Veer, W. M., van Egmond, M., Niessen, F. B., & Beelen, R. H. J. (2011) · Immunobiology · doi:10.1016/j.imbio.2011.01.001 · Cited by 922
Gittens, R. A., Olivares-Navarrete, R., Schwartz, Z., & Boyan, B. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.037 · Cited by 447
Self-citationSagomonyants, K. B., Jarman-Smith, M. L., Devine, J. N., Aronow, M. S., & Gronowicz, G. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.001 · Cited by 320
Olivares-Navarrete, R., Hyzy, S. L., Hutton, D. L., Erdman, C. P., Wieland, M., Boyan, B. D., & Schwartz, Z. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.029 · Cited by 305
Self-citationWebster, T. J., Patel, A., Rahaman, M. N., & Bal, B. S. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.07.038 · Cited by 271
Osteoblast‐like cells are sensitive to submicron‐scale surface structure
Zhao, G., Zinger, O., Schwartz, Z., Wieland, M., Landolt, D., & Boyan, B. D. (2006) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2005.01195.x · Cited by 248
Self-citationOlivares-Navarrete, R., Gittens, R. A., Schneider, J. M., Hyzy, S. L., Haithcock, D. A., Ullrich, P. F., Schwartz, Z., & Boyan, B. D. (2012) · The Spine Journal · doi:10.1016/j.spinee.2012.02.002 · Cited by 216
Self-citationMacrophage and dendritic cell phenotypic diversity in the context of biomaterials
Kou, P. M., & Babensee, J. E. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32971 · Cited by 190
Effect of Micrometer-Scale Roughness of the Surface of Ti6Al4V Pedicle Screws in Vitro and in Vivo
Schwartz, Z., Raz, P., Zhao, G., Barak, Y., Tauber, M., Yao, H., & Boyan, B. D. (2008) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.00499 · Cited by 163
Self-citationPoulsson, A. H. C., Eglin, D., Zeiter, S., Camenisch, K., Sprecher, C. M., Agarwal, Y., Nehrbass, D., Wilson, J., & Richards, R. G. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.12.056 · Cited by 161
Rough titanium alloys regulate osteoblast production of angiogenic factors
Olivares‐Navarrete, R., Hyzy, S. L., Gittens, R. A., Schneider, J. M., Haithcock, D. A., Ullrich, P. F., Slosar, P. J., Schwartz, Z., & Boyan, B. D. (2013) · The Spine Journal · doi:10.1016/j.spinee.2013.03.047 · Cited by 127
Self-citationPark, J. H., Wasilewski, C. E., Almodovar, N., Olivares‐Navarrete, R., Boyan, B. D., Tannenbaum, R., & Schwartz, Z. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.066 · Cited by 122
Self-citationThom�, C., Krauss, J. K., & Zevgaridis, D. (2004) · Neurosurgical Review · doi:10.1007/s10143-003-0297-2 · Cited by 110
Differentiation of human mesenchymal stem cells on plasma-treated polyetheretherketone
Waser-Althaus, J., Salamon, A., Waser, M., Padeste, C., Kreutzer, M., Pieles, U., Müller, B., & Peters, K. (2013) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-013-5072-5 · Cited by 105
Dendritic cell responses to surface properties of clinical titanium surfaces
Kou, P. M., Schwartz, Z., Boyan, B. D., & Babensee, J. E. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.10.020 · Cited by 73
Self-citationKou, P. M., Narayanan, P., Bowden, R., Cunningham, B. R., Joy, A., Kohn, J., & Babensee, J. E. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.066 · Cited by 57
Smith, K. E., Hyzy, S. L., Sunwoo, M., Gall, K., Schwartz, Z., & Boyan, B. D. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.033 · Cited by 46
Self-citationPark, J. H., Olivares‐Navarrete, R., Wasilewski, C. E., Boyan, B. D., Tannenbaum, R., & Schwartz, Z. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.03.074 · Cited by 37
Self-citationKou, P. M., & Babensee, J. E. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.01.023 · Cited by 18
Cited by
Challenges and advances in clinical applications of mesenchymal stromal cells
Zhou, T., Yuan, Z., Weng, J., Pei, D., Du, X., He, C., & Lai, P. (2021) · Journal of Hematology & Oncology · doi:10.1186/s13045-021-01037-x · Cited by 712
Spriano, S., Yamaguchi, S., Baino, F., & Ferraris, S. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.013 · Cited by 395
Metal Drugs and the Anticancer Immune Response
Englinger, B., Pirker, C., Heffeter, P., Terenzi, A., Kowol, C. R., Keppler, B. K., & Berger, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00396 · Cited by 355
McGilvray, K. C., Easley, J., Seim, H. B., Regan, D., Berven, S. H., Hsu, W. K., Mroz, T. E., & Puttlitz, C. M. (2018) · The Spine Journal · doi:10.1016/j.spinee.2018.02.018 · Cited by 256
Porous PEEK improves the bone-implant interface compared to plasma-sprayed titanium coating on PEEK
Torstrick, F. B., Lin, A. S. P., Potter, D., Safranski, D. L., Sulchek, T. A., Gall, K., & Guldberg, R. E. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.009 · Cited by 229
Metadata
- Authors
- Olivares-Navarrete, R., Hyzy, S. L., Slosar, P. J., Schneider, J. M., Schwartz, Z., & Boyan, B. D.
- Venue
- Spine
- Published
- 2015-03
- Volume
- 40
- Issue
- 6
- Pages
- 399-404
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2332211797
- Cited by
- 162
- References
- 21
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.