The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Ultrasound assessment of lung aeration loss during a successful weaning trial predicts postextubation distress*
Abstract
OBJECTIVE: Postextubation distress after a successful spontaneous breathing trial is associated with increased morbidity and mortality. Predicting postextubation distress is therefore a major issue in critically ill patients. To assess whether lung derecruitment during spontaneous breathing trial assessed by lung ultrasound is predictive of postextubation distress. DESIGN AND SETTING: Prospective study in two multidisciplinary intensive care units within University Hospital. PATIENTS AND METHODS: One hundred patients were included in the study. Lung ultrasound, echocardiography, and plasma B-type natriuretic peptide levels were determined before and at the end of a 60-min spontaneous breathing trial and 4 hrs after extubation. To quantify lung aeration, a lung ultrasound score was calculated. Patients were followed up to hospital discharge. MEASUREMENTS AND MAIN RESULTS: Fourteen patients failed the spontaneous breathing trial, 86 were extubated, 57 were definitively weaned (group 1), and 29 suffered from postextubation distress (group 2). Loss of lung aeration during the successful spontaneous breathing trial was observed only in group 2 patients: lung ultrasound scores increased from 15 [13;17] to 19 [16; 21] (p < .01). End-spontaneous breathing trial lung ultrasound scores were significantly higher in group 2 than in group 1 patients: 19 [16;21] vs. 10 [7;13], respectively (p < .001) and predicted postextubation distress with an area under the receiver operating characteristic curve of 0.86. Although significantly higher in group 2, B-type natriuretic peptide and echocardiography cardiac filling pressures were not clinically helpful in predicting postextubation distress. CONCLUSION: Lung ultrasound determination of aeration changes during a successful spontaneous breathing trial may accurately predict postextubation distress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Esteban, A. (2002) · JAMA · doi:10.1001/jama.287.3.345 · Cited by 1,779
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
Lichtenstein, D., Goldstein, I., Mourgeon, E., Cluzel, P., Grenier, P., & Rouby, J.-J. (2004) · Anesthesiology · doi:10.1097/00000542-200401000-00006 · Cited by 1,077
Self-citationThe Comet-tail Artifact: An Ultrasound Sign of Alveolar-Interstitial Syndrome
LICHTENSTEIN, D., MÉZIÈRE, G., BIDERMAN, P., GEPNER, A., & BARRÉ, O. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.5.96-07096 · Cited by 1,075
ESTEBAN, A., ALÍA, I., TOBIN, M. J., GIL, A., GORDO, F., VALLVERDÚ, I., BLANCH, L., BONET, A., VÁZQUEZ, A., de PABLO, R., et al. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9803106 · Cited by 773
Clinical review: Bedside lung ultrasound in critical care practice.
Bouhemad, B., Zhang, M., Lü, Q., & Rouby, J. (2007) · Critical Care · doi:10.1186/cc5668 · Cited by 768
Self-citationBedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment
Bouhemad, B., Brisson, H., Le-Guen, M., Arbelot, C., Lu, Q., & Rouby, J.-J. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201003-0369oc · Cited by 735
Self-citationRe-intubation increases the risk of nosocomial pneumonia in patients needing mechanical ventilation.
Torres, A., Gatell, J. M., Aznar, E., el-Ebiary, M., Puig de la Bellacasa, J., González, J., Ferrer, M., & Rodriguez-Roisin, R. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.1.7599812 · Cited by 696
“Ultrasound Comet-Tail Images”: A Marker Of Pulmonary Edema
Agricola, E., Bove, T., Oppizzi, M., Marino, G., Zangrillo, A., Margonato, A., & Picano, E. (2005) · Chest · doi:10.1378/chest.127.5.1690 · Cited by 597
Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical Ventilation
Lemaire, F., Teboul, J.-L., Cinotti, L., Giotto, G., Abrouk, F., Steg, G., Macquin-Mavier, I., & Zapol, W. M. (1988) · Anesthesiology · doi:10.1097/00000542-198808000-00004 · Cited by 570
PRINCIPLES AND PRACTICE OF MECHANICAL VENTILATION
Tobin, M. J. (1996) · Shock · doi:10.1097/00024382-199601000-00018 · Cited by 562
Ventilator-induced Diaphragmatic Dysfunction
Vassilakopoulos, T., & Petrof, B. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-489cp · Cited by 520
Ultrasound diagnosis of alveolar consolidation in the critically ill
Lichtenstein, D. A., Lascols, N., Mezière, G., & Gepner, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2075-6 · Cited by 512
Statistical Evaluation of a Biomarker
Ray, P., Manach, Y. L., Riou, B., Houle, T. T., & Warner, D. S. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181d47604 · Cited by 503
Khamiees, M., Raju, P., DeGirolamo, A., Amoateng-Adjepong, Y., & Manthous, C. A. (2001) · Chest · doi:10.1378/chest.120.4.1262 · Cited by 466
Risk Factors for Extubation Failure in Patients Following a Successful Spontaneous Breathing Trial
Frutos-Vivar, F., Ferguson, N. D., Esteban, A., Epstein, S. K., Arabi, Y., Apezteguía, C., González, M., Hill, N. S., Nava, S., D’Empaire, G., et al. (2006) · Chest · doi:10.1378/chest.130.6.1664 · Cited by 406
Peñuelas, O., Frutos-Vivar, F., Fernández, C., Anzueto, A., Epstein, S. K., Apezteguía, C., González, M., Nin, N., Raymondos, K., Tomicic, V., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201011-1887oc · Cited by 350
Evaluation of ultrasound lung comets by hand-held echocardiography
Bedetti, G., Gargani, L., Corbisiero, A., Frassi, F., Poggianti, E., & Mottola, G. (2006) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-4-34 · Cited by 222
Clinical review: The ABC of weaning failure - a structured approach
Heunks, L. M., & van der Hoeven, J. G. (2010) · Critical Care · doi:10.1186/cc9296 · Cited by 220
Lamia, B., Maizel, J., Ochagavia, A., Chemla, D., Osman, D., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819f13d0 · Cited by 178
Depressive disorders during weaning from prolonged mechanical ventilation
Jubran, A., Lawm, G., Kelly, J., Duffner, L. A., Güngör, G., Collins, E. G., Lanuza, D. M., Hoffman, L. A., & Tobin, M. J. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1842-4 · Cited by 164
Extubation failure in intensive care unit: Predictors and management
Kulkarni, A. P., & Agarwal, V. (2008) · Indian Journal of Critical Care Medicine · doi:10.4103/0972-5229.40942 · Cited by 159
B-type natriuretic peptide and weaning from mechanical ventilation
Dessap, A. M., de Prost, N., Girou, E., Braconnier, F., Lemaire, F., Brun‐Buisson, C., & Brochard, L. J. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0339-7 · Cited by 149
A new integrative weaning index of discontinuation from mechanical ventilation
Nemer, S. N., Barbas, C. S. V., Caldeira, J. B., Cárias, T. C., Santos, R. G., Almeida, L. C., de Azeredo, L. M., Noé, R., Guimarães, B. S., & Souza, P. C. P. (2009) · Critical Care · doi:10.1186/cc8051 · Cited by 129
B-type natriuretic peptides for prediction and diagnosis of weaning failure from cardiac origin
Zapata, L., Vera, P., Roglan, A., Gich, I. J., Ordóñez‐Llanos, J., & Betbese, A. J. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-2101-4 · Cited by 110
[B-type natriuretic peptide and weaning from mechanical ventilation].
Lai, L.-R., Wang, Z., & Tong, Z.-H. (2013) · PubMed · Cited by 110
Interval likelihood ratios: Another advantage for the evidence-based diagnostician
Brown, M. D., & Reeves, M. J. (2003) · Annals of Emergency Medicine · doi:10.1067/mem.2003.274 · Cited by 109
Extubation failure: an outcome to be avoided.
Epstein, S. K. (2004) · Critical Care · doi:10.1186/cc2927 · Cited by 105
Post-traumatic stress disorder after weaning from prolonged mechanical ventilation
Jubran, A., Lawm, G., Duffner, L. A., Collins, E. G., Lanuza, D. M., Hoffman, L. A., & Tobin, M. J. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1972-8 · Cited by 105
Weaning from mechanical ventilation.
Tobin, M. J., & Yang, K. (1990) · PubMed · Cited by 104
Chalumeau-Lemoine, L., Baudel, J.-L., Das, V., Arrivé, L., Noblinski, B., Guidet, B., Offenstadt, G., & Maury, É. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1531-3 · Cited by 93
Chien, J., Lin, M., Huang, Y.-C. T., Chien, Y.-F., Yu, C., & Yang, P. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31816f49ac · Cited by 92
Ventilator-induced diaphragm dysfunction: the clinical relevance of animal models
Vassilakopoulos, T. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0866-x · Cited by 88
Using sonography to assess lung recruitment in patients with acute respiratory distress syndrome
Gardelli, G., Feletti, F., Gamberini, E., Bonarelli, S., Nanni, A., & Mughetti, M. (2008) · Emergency Radiology · doi:10.1007/s10140-008-0734-1 · Cited by 36
Tsubo, T., Yatsu, Y., Tanabe, T., Okawa, H., Ishihara, H., & MATSUKI, A. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000104944.18636.b2 · Cited by 32
Gravity, the Belly, and the Diaphragm
Froese, A. B., & Raja, S. N. (2005) · Anesthesiology · doi:10.1097/00000542-200601000-00026 · Cited by 25
Cited by
Findings of lung ultrasonography of novel corona virus pneumonia during the 2019–2020 epidemic
Chinese Critical Care Ultrasound Study Group (CCUSG), Peng, Q.-Y., Wang, X.-T., & Zhang, L.-N. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-05996-6 · Cited by 737
The Decision to Extubate in the Intensive Care Unit
Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1523ci · Cited by 576
Maggiore, S. M., Idone, F. A., Vaschetto, R., Festa, R., Cataldo, A., Antonicelli, F., Montini, L., De Gaetano, A., Navalesi, P., & Antonelli, M. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201402-0364oc · Cited by 546
Lung Ultrasound for Critically Ill Patients
Mojoli, F., Bouhemad, B., Mongodi, S., & Lichtenstein, D. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201802-0236ci · Cited by 513
Point‐of‐care lung ultrasound in patients with COVID ‐19 – a narrative review
Smith, M. J., Hayward, S. A., Innes, S. M., & Miller, A. S. C. (2020) · Anaesthesia · doi:10.1111/anae.15082 · Cited by 318
Metadata
- Authors
- Soummer, A., Perbet, S., Brisson, H., Arbelot, C., Constantin, J.-M., Lu, Q., & Rouby, J.-J.
- Venue
- Critical Care Medicine
- Published
- 2012-07
- Volume
- 40
- Issue
- 7
- Pages
- 2064-2072
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2161177864
- Cited by
- 519
- References
- 39
- FWCI
- 9.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.