Sources of inaccuracy in the measurement of adult patients’ resting blood pressure in clinical settings: a systematic review
Open accessThe DOI matches its Crossref record; 386 of the 390 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
BACKGROUND: To interpret blood pressure (BP) data appropriately, healthcare providers need to be knowledgeable of the factors that can potentially impact the accuracy of BP measurement and contribute to variability between measurements. METHODS: A systematic review of studies quantifying BP measurement inaccuracy. Medline and CINAHL databases were searched for empirical articles and systematic reviews published up to June 2015. Empirical articles were included if they reported a study that was relevant to the measurement of adult patients' resting BP at the upper arm in a clinical setting (e.g. ward or office); identified a specific source of inaccuracy; and quantified its effect. Reference lists and reviews were searched for additional articles. RESULTS: A total of 328 empirical studies were included. They investigated 29 potential sources of inaccuracy, categorized as relating to the patient, device, procedure or observer. Significant directional effects were found for 27; however, for some, the effects were inconsistent in direction. Compared with true resting BP, significant effects of individual sources ranged from -23.6 to +33 mmHg SBP and -14 to +23 mmHg DBP. CONCLUSION: A single BP value outside the expected range should be interpreted with caution and not taken as a definitive indicator of clinical deterioration. Where a measurement is abnormally high or low, further measurements should be taken and averaged. Wherever possible, BP values should be recorded graphically within ranges. This may reduce the impact of sources of inaccuracy and reduce the scope for misinterpretations based on small, likely erroneous or misleading, changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“On a beat-to-beat basis, BP levels can vary markedly (from –24 mmHg to 33 mmHg) in response to usual extrinsic and behavioural factors4”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the highly variable nature of office and out-of-office BP readings has been widely acknowledged”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [4]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Standardization is essential because there are many aspects of BP measurement, including the patient’s physical condition, clinic environment, and equipment that can readily result in inaccurate and unreliable values.23,25,26”
From International Consensus on Standardized Clinic Blood Pressure Measurement – A Call to Action (2023) · cites this paper as [25]
In the citing paper
“Even when a validated automated device is used, the accuracy of BP measurement may be influenced by many factors. 19 – 21”
From Hypertension Canada guideline for the diagnosis and treatment of hypertension in adults in primary care (2025) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–387 of 387
Automated versus manual blood pressure measurement: A randomized crossover trial
Heinemann, M., Sellick, K., Rickard, C. M., Reynolds, P., & McGrail, M. R. (2008) · International Journal of Nursing Practice · doi:10.1111/j.1440-172x.2008.00696.x · Cited by 35
Hla, K. M., Vokaty, K. A., & Feussner, J. R. (1986) · Archives of Internal Medicine · doi:10.1001/archinte.1986.00360240099017 · Cited by 35
Acute Effects of a Mixed Meal on Arterial Stiffness and Central Hemodynamics in Healthy Adults
Taylor, J. L., Curry, T. B., Matzek, L. J., Joyner, M. J., & Casey, D. P. (2013) · American Journal of Hypertension · doi:10.1093/ajh/hpt211 · Cited by 35
Comparison of non‐invasive and invasive blood pressure in aeromedical care
McMahon, N., Hogg, L. A., Corfield, A. R., & Exton, A. D. (2012) · Anaesthesia · doi:10.1111/j.1365-2044.2012.07302.x · Cited by 34
Accuracy of automated blood pressure monitors.
Nelson, D. M., Kennedy, B., Regnerus, C., & Schweinle, A. (2008) · PubMed · Cited by 34
Arm position as a source of error in blood pressure measurement
Mariotti, G., Alli, C., Avanzini, F., Canciani, C., Di Tullio, M., Manzini, M., Salmoirago, E., Taioli, E., Zussino, A., & Radice, M. (1987) · Clinical Cardiology · doi:10.1002/clc.4960101016 · Cited by 34
Arciero, P. J., & Ormsbee, M. J. (2009) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h09-068 · Cited by 34
An evaluation of the A& D UA-751 semi-automated cuff-oscillometric sphygmomanometer
Jamieson, M. J., Webster, J., Witte, K., Huggins, M. M., MacDonald, T. M., de Beaux, A., & Petrie, J. C. (1990) · Journal of Hypertension · doi:10.1097/00004872-199004000-00012 · Cited by 34
McMullen, M. K., Whitehouse, J. M., Shine, G., & Towell, A. (2011) · Food & Function · doi:10.1039/c0fo00166j · Cited by 34
Semret, M. H., Zidehsarai, M. P., & Agarwal, R. (2005) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000172713.28029.84 · Cited by 34
Blood pressure variability: the effects of repeated measurement
Burstyn, P. G., O’Donovan, B., & Charlton, I. (1981) · Postgraduate Medical Journal · doi:10.1136/pgmj.57.670.488 · Cited by 34
Turjanmaa, V. (1989) · Clinical Physiology · doi:10.1111/j.1475-097x.1989.tb00991.x · Cited by 33
Changes in Blood Pressure and Plasma Catecholamines Caused by Tyramine and Cold Exposure
Scriven, A., Brown, M. J., Murphy, M. B., & Dollery, C. T. (1984) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-198409000-00033 · Cited by 33
Alcohol Raises Blood Pressure in Hypertensive Patients
Potter, J. F., Macdonald, I. A., & Beevers, D. G. (1986) · Journal of Hypertension · doi:10.1097/00004872-198608000-00007 · Cited by 33
Effects of caffeine on pressor regulation during rest and exercise in men at risk for hypertension
Pincomb, G. A., Wilson, M. F., Sung, B. H., Passey, R. B., & Lovallo, W. R. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90479-2 · Cited by 33
Zachariah, P. K., Sheps, S. G., & Moore, A. G. (1990) · International Journal of Cardiology · doi:10.1016/0167-5273(90)90319-z · Cited by 33
Vera-Cala, L. M., Oróstegui, M., Valencia-Ángel, L. I., López, N., & Bautista, L. E. (2011) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2011005000038 · Cited by 32
Hering, D., Kucharska, W., Kára, T., Somers, V. K., & Narkiewicz, K. (2011) · Journal of Hypertension · doi:10.1097/hjh.0b013e328342b2a9 · Cited by 32
Brunel, P., Girerd, X. J., Laurent, S., Pannier, B., & Safar, M. E. (1992) · European Journal of Clinical Pharmacology · doi:10.1007/bf00278473 · Cited by 31
Burnier, M., & Gasser, U. E. (2008) · Blood Pressure · doi:10.1080/08037050801972881 · Cited by 31
Guzzetti, S., Mayet, J., Shahi, M., Mezzetti, S., Foale, R. A., Sever, P., Poulter, N. R., Porta, A., Malliani, A., & Thom, S. (2000) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001009 · Cited by 31
Ambulatory blood pressure of adults in Novosibirsk, Russia: interim report on a population study
Kuznetsova, T., Malyutina, S., Pello, E., Thijs, L., Nikitin, Y., & Staessen, J. A. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200010000-00007 · Cited by 31
The Auscultatory Gap in Sphygmomanometry
Askey, J. M. (1974) · Annals of Internal Medicine · doi:10.7326/0003-4819-80-1-94 · Cited by 30
The effect of crossing legs on blood pressure
Adiyaman, A., Tosun, N., Elving, L. D., Deinum, J., Lenders, J. W. M., & Thien, T. A. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3280b083a7 · Cited by 30
Campbell, N. R. C., Conradson, H. E., Kang, J., Brant, R., & Anderson, T. (2005) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000173486.44648.b2 · Cited by 30
Graves, J. W., Bailey, K. R., Grossardt, B. R., Gullerud, R. E., Meverden, R. A., Grill, D. E., & Sheps, S. G. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.04.004 · Cited by 30
Agreement Between Large And Small Cuffs In Sphygmomanometry: A Quantitative Assessment
Iyriboz, Y., Hearon, C. M., & Edwards, K. (1994) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02886825 · Cited by 30
Accuracy of prehospital sphygmomanometers
Jones, J. S., Ramsey, W., & Hetrick, T. (1987) · Journal of Emergency Medicine · doi:10.1016/0736-4679(87)90006-0 · Cited by 30
Lehmann, K. G., Gelman, J. A., Weber, M. A., & Lafrades, A. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00080-0 · Cited by 30
Bidis—hand-rolled, Indian cigarettes:
Malson, J. L., & Pickworth, W. B. (2002) · Pharmacology Biochemistry and Behavior · doi:10.1016/s0091-3057(02)00709-8 · Cited by 29
Twenty-four hour ambulatory blood pressure in a population of elderly men
Björklund, K., Lind, L., & Lithell, H. (2000) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.2000.00760.x · Cited by 29
Kahan, E. (2003) · Family Practice · doi:10.1093/fampra/cmg618 · Cited by 29
Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement
Yarows, S. A., Patel, K., & Brook, R. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200106000-00005 · Cited by 29
Freestone, S. H., Yeo, W. W., & Ramsay, L. E. (1995) · PubMed · Cited by 28
Goonasekera, C. D. A., & Dillon, M. J. (1995) · PubMed · Cited by 28
Validation of the Pharma-Smart PS-2000 public use blood pressure monitor
Alpert, B. S. (2004) · Blood Pressure Monitoring · doi:10.1097/00126097-200402000-00005 · Cited by 28
Assessment of the Accuracy of Indirect Blood Pressure Measurements.
Ochiai, H., 宮崎, 直., MIYATA, T., Mitake, A., Tochikubo, O., & Ishii, M. (1997) · Japanese Heart Journal · doi:10.1536/ihj.38.393 · Cited by 28
The Effects of Crossed Leg on Blood Pressure Measurement
Foster-Fitzpatrick, L., Ortiz, A. C., Sibilano, H., Marcantonio, R., & Braun, L. T. (1999) · Nursing Research · doi:10.1097/00006199-199903000-00009 · Cited by 28
Accuracy of an Automated Blood Pressure Device in Stable Inpatients: Optimum vs Routine Use
Shuler, C. L., Allison, N. L., Holcomb, S., Harlan, M., McNeill, J., Robinett, G., & Bagby, S. P. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.7.714 · Cited by 28
Karagiannis, A. I., Τζιόμαλος, Κ., Krikis, N., Sfikas, G., Dona, K., & Zamboulis, C. (2005) · Angiology · doi:10.1177/000331970505600507 · Cited by 28
The effect of sleeved arms on oscillometric blood pressure measurement
Holleman, D. R., Westman, E. C., McCrory, D. C., & Simel, D. L. (1993) · Journal of General Internal Medicine · doi:10.1007/bf02600148 · Cited by 28
Yong, P. G., & Geddes, L. A. (1987) · The Journal of Clinical Monitoring · doi:10.1007/bf01695937 · Cited by 28
How Important is the Recommended Slow Cuff Pressure Deflation Rate for Blood Pressure Measurement?
Zheng, D., Amoore, J. N., Mieke, S., & Murray, A. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0347-9 · Cited by 28
Agyemang, C. O., Bhopal, R. S., Bruijnzeels, M. A., & Redekop, K. (2005) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000172712.89910.e4 · Cited by 28
Auscultatory blood pressure measurement--effect of pressure on the head of the stethoscope.
Londe, S., & Klitzner, T. S. (1984) · PubMed Central · Cited by 27
Acute effects of red wine on cytochrome P450 eicosanoids and blood pressure in men
Barden, A. E., Croft, K. D., Beilin, L. J., Phillips, M. R., Ledowski, T., & Puddey, I. B. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328364a27f · Cited by 27
m, I. E., Thulin, T., & Lindholm, L. H. (1991) · Journal of Hypertension · doi:10.1097/00004872-199106000-00012 · Cited by 27
Effects of crossed leg on blood pressure
Pınar, R., Sabuncu, N., & Şahin, A. O. (2004) · Blood Pressure · doi:10.1080/08037050410000903 · Cited by 27
Ayodele, O. E., Sanya, E. O., Okunola, O. A., & Akintunde, A. A. (2012) · Cardiovascular journal of South Africa/Cardiovascular journal of Southern Africa · doi:10.5830/cvja-2011-045 · Cited by 26
The Validity of Emergency Department Triage Blood Pressure Measurements
Cienki, J. J., DeLuca, L., & Daniel, N. (2004) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2004.tb02203.x · Cited by 26
Alternatives to the mercury sphygmomanometer
Buchanan, S. N., Orris, P., & Karliner, J. (2010) · Journal of Public Health Policy · doi:10.1057/jphp.2010.38 · Cited by 26
Blood pressure responses to whole-body cold exposure: effect of carvedilol
Komulainen, S., Tähtinen, T., Rintamäki, H., Virokannas, H., & Keinanen-Kiukaanniemi, S. M. (2000) · European Journal of Clinical Pharmacology · doi:10.1007/s002280000208 · Cited by 26
Munakata, M., Saito, Y., Nunokawa, T., Ito, N., Fukudo, S., & YOSHINAGA, K. (2002) · Hypertension Research · doi:10.1291/hypres.25.343 · Cited by 26
Piters, K. M., Colombo, A., Olson, H. G., & Butman, S. M. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90360-1 · Cited by 25
Sphygmomanometers in use in general practice: an overlooked aspect of quality in patient care
Knight, T., Leech, F., Jones, A., Walker, L., Wickramasinghe, R., Angris, S., & Rolfe, P. M. (2001) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001251 · Cited by 25
Thirty-minute compared to standardised office blood pressure measurement in general practice
Haan, N. S., van der Wel, M., Schoenmakers, G., Boudewijns, S., Peer, P. G. M., van Weel, C., Thien, T. A., & Bakx, C. (2011) · British Journal of General Practice · doi:10.3399/bjgp11x593875 · Cited by 25
Acute effects of coffee on QT interval in healthy subjects
Buscemi, S., Mattina, A., Tranchina, M. R., & Verga, S. (2011) · Nutrition Journal · doi:10.1186/1475-2891-10-15 · Cited by 25
The effect of hemiplegia on blood pressure measurement in the elderly
Dewar, R., Sykes, D., Mulkerrin, E. C., Nicklason, F., Thomas, D. M., & Seymour, R. (1992) · Postgraduate Medical Journal · doi:10.1136/pgmj.68.805.888 · Cited by 25
Magnitude of the White-Coat Effect in the Community Pharmacy Setting: The MEPAFAR Study
Sabater‐Hernández, D., Sierra, A., Sánchez‐Villegas, P., Baena, M. I., Amariles, P., Faus, M. J., & workgroup, O. B. O. T. M. S. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.68 · Cited by 25
Pseudohypertension and the measurement of blood pressure.
Bos, W. J. W., van Goudoever, J., Wesseling, K. H., Rongen, G. A. P. J. M., Hoedemaker, G., Lenders, J. W. M., & van Montfrans, G. A. (1992) · Hypertension · doi:10.1161/01.hyp.20.1.26 · Cited by 25
Inflationary oscillometric blood pressure monitoring: validation of the OMRON-MIT
Golara, M., Jones, C., Randhawa, M., & Shennan, A. H. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200212000-00006 · Cited by 25
Carel, R. S., Silverberg, D. S., Shoenfeld, Y., Eldar, M., Snir, C., & Mor, G. (1983) · The American Journal of the Medical Sciences · doi:10.1097/00000441-198303000-00001 · Cited by 24
Roubsanthisuk, W., Wongsurin, U., Saravich, S., & Buranakitjaroen, P. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3280b08317 · Cited by 24
Nicotine and caffeine effects on the task-elicited blood pressure response
Ray, R. L., Nellis, M. J., Brady, J. V., & Foltin, R. W. (1986) · Addictive Behaviors · doi:10.1016/0306-4603(86)90006-7 · Cited by 24
Chase, H. P., Garg, S. K., Icaza, G., Carmain, J. A., Walravens, C. F., & Marshall, G. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(96)00260-9 · Cited by 24
Effect of Fowler’s body position on blood pressure measurement
Cicolini, G., Gagliardi, G., & Ballone, E. (2010) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2010.03418.x · Cited by 23
Mengden, T., Asmar, R. G., Kandra, A., Giovanni, R. D., Brudi, P., & Parati, G. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328339d516 · Cited by 23
Bell or diaphragm in the measurement of blood pressure?
Kantola, I., Vesalainen, R., Kangassalo, K., & Kariluoto, A. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000160204.74028.95 · Cited by 23
Uncovering a hidden language: The effects of listening and talking on blood pressure and heart rate
Liehr, P. R. (1992) · Archives of Psychiatric Nursing · doi:10.1016/0883-9417(92)90042-h · Cited by 23
The Influence of Talking on Diastolic Blood Pressure Readings
Hellmann, R., & Grimm, S. A. (1984) · Research in Nursing & Health · doi:10.1002/nur.4770070403 · Cited by 23
Effects of Crossing Legs on Blood Pressure Measurement
Keele-Smith, R., & Price-Daniel, C. (2001) · Clinical Nursing Research · doi:10.1177/c10n2r8 · Cited by 22
Coe, T. (2002) · Ambulatory Surgery · doi:10.1016/s0966-6532(01)00112-3 · Cited by 22
Stergiou, G. S., Lin, C., Lin, C.-M., Chang, S.-L., Protogerou, A. D., Tzamouranis, D., Nasothimiou, E. G., & Tan, T.-M. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283057a84 · Cited by 22
SHAHRIARI, M., ROTENBERG, D. K., Nielsen, J. K., Wiinberg, N., & Nielsen, P. E. (2003) · Blood Pressure · doi:10.1080/08037050310007998 · Cited by 22
End-Digit Preference and the Quality of Blood Pressure Monitoring in Diabetic Adults
Kim, E. S. H., Samuels, T. A., Yeh, H., Abuid, M., Marinopoulos, S. S., McCauley, J., & Brancati, F. L. (2007) · Diabetes Care · doi:10.2337/dc07-0020 · Cited by 22
Sendra‐Lillo, J., Sabater‐Hernández, D., Sendra-Ortolá, A., & Martínez‐Martínez, F. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328344c755 · Cited by 22
Acute effect of maternal smoking on the maternal and fetal cardiovascular system
Pijpers, L., Wladimiroff, J. W., McGhie, J. S., & Bom, N. (1984) · Early Human Development · doi:10.1016/0378-3782(84)90115-4 · Cited by 21
Caffeine and behavioral stress effects on blood pressure in borderline hypertensive Caucasian men.
Lovallo, W. R., al'Absi, M., Pincomb, G. A., & Everson, S. A. (1996) · Health Psychology · doi:10.1037//0278-6133.15.1.11 · Cited by 21
Lim, Y., Choi, S., Oh, K., Kim, Y., Cho, E. S., Choi, B. Y., Kim, Y., & Shin, J. (2013) · American Journal of Hypertension · doi:10.1093/ajh/hpt100 · Cited by 21
Effects of Meals and Time of Day on Postural Blood Pressure Responses in Young and Elderly Subjects
Mader, S. L. (1989) · Archives of Internal Medicine · doi:10.1001/archinte.1989.00390120097019 · Cited by 21
Effects of sphygmomanometer type and position of the arm on blood pressure measurement.
Parr, G. D., & Poole, P. H. (1988) · PubMed · Cited by 20
Pailleur, C. L., Montgermont, P., Feder, J. M., Metzger, J., & Vacheron, A. (2001) · Behavioral Medicine · doi:10.1080/08964280109595762 · Cited by 20
Determinants of the White‐Coat Effect in Normotensives and Never‐Treated Mild Hypertensives
Tsai, P. (2003) · Clinical and Experimental Hypertension · doi:10.1081/ceh-120024987 · Cited by 20
Ambulatory Blood Pressure Monitoring in Uygur Centenarians
Jumabay, M., Ozawa, Y., Kawamura, H., Saito, S., Izumi, Y., Mitsubayashi, H., Kasamaki, Y., Nakayama, T., Masum, M., Cheng, Z., et al. (2002) · Circulation Journal · doi:10.1253/circj.66.75 · Cited by 20
Twenty‐four hour ambulatory blood pressure in the population
Nyström, F. H., MALMSTRÖM, O., Karlberg, B. E., & Öhman, K. P. (1996) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.1996.322856000.x · Cited by 20
Confounders of auscultatory blood pressure measurement
Baker, R., & Ende, J. (1995) · Journal of General Internal Medicine · doi:10.1007/bf02600259 · Cited by 20
Torrance, C., & Serginson, E. (1996) · Nurse Education Today · doi:10.1016/s0260-6917(96)80116-x · Cited by 20
Review article: Part one: Goal‐directed resuscitation – Which goals? Haemodynamic targets
Holley, A., Lukin, B., Paratz, J. D., Hawkins, T., Boots, R. J., & Lipman, J. (2012) · Emergency Medicine Australasia · doi:10.1111/j.1742-6723.2011.01516.x · Cited by 20
Factors Determining the Acute Pressor Response to Alcohol
Potter, J. F., & Beevers, D. G. (1991) · Clinical and Experimental Hypertension · doi:10.3109/10641969109082612 · Cited by 20
Tomasulo, M. M. V., & Patterson, S. (2005) · Biological Psychology · doi:10.1016/j.biopsycho.2005.04.006 · Cited by 19
Mireles, S. A., Jaffe, R., Drover, D. R., & Brock‐Utne, J. G. (2009) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-009-9178-8 · Cited by 19
Christofidis, M. J., Hill, A., Horswill, M. S., & Watson, M. (2015) · Journal of Advanced Nursing · doi:10.1111/jan.12824 · Cited by 19
Self-citationThe Normal Difference in Bilateral Indirect Blood Pressure Recordings in Hypertensive Individuals
Pesola, G. R., Pesola, H. R., Lin, M.-Y., et al. (2002) · Academic Emergency Medicine · doi:10.1197/aemj.9.4.342 · Cited by 19
Pseudo-hypertension and arterial stiffness: a review
Foran, T. G., Sheahan, N. F., Cunningham, C. J., & Feely, J. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r02 · Cited by 18
Agarwal, R., & Weir, M. R. (2013) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2013.02.005 · Cited by 18
Fonseca‐Reyes, S., Fajardo-Flores, I., Montes-Casillas, M., & Forsyth-MacQuarrie, A. M. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32832ea9f0 · Cited by 18
Folsom, A. R., Prineas, R. J., Jacobs, D. R., Luepker, R. V., & Gillum, R. F. (1984) · International Journal of Epidemiology · doi:10.1093/ije/13.4.436 · Cited by 18
Comparison of three devices for measuring blood pressure
Bassein, L., Borghi, C., Costa, F. V., Strocchi, E., Mussi, A., & Ambrosioni, E. (1985) · Statistics in Medicine · doi:10.1002/sim.4780040316 · Cited by 18
The Mean Machine; Accurate Non-invasive Blood Pressure Measurement in the Critically Ill Patient
Muecke, S., Bersten, A. D., & Plummer, J. (2009) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-009-9195-7 · Cited by 17
Variation in recorded blood pressure terminal digit bias in general practice
Harrison, W. N., Lancashire, R. J., & Marshall, T. P. (2007) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1002312 · Cited by 17
Effects of meals and time of day on postural blood pressure responses in young and elderly subjects.
Mader, S. L. (1989) · PubMed · Cited by 17
Blood pressure responses to whole-body cold exposure: effect of metoprolol
Komulainen, S., Rintamäki, H., Virokannas, H., & Keinanen-Kiukaanniemi, S. M. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001758 · Cited by 17
The Impact of Bladder Distension on Blood Pressure in Middle Aged Women
Choi, E. J., Jeong, D. W., Lee, J. G., Lee, S. Y., Kim, Y. J., Yi, Y. H., Cho, Y. H., Im, S. J., & Bae, M. J. (2011) · Korean Journal of Family Medicine · doi:10.4082/kjfm.2011.32.5.306 · Cited by 17
Blood Pressure in the Paretic Arms of Patients with Stroke
Yagi, S., Ichikawa, S., Sakamaki, T., Takayama, Y., & Murata, K. (1986) · New England Journal of Medicine · doi:10.1056/nejm198609253151318 · Cited by 17
White coat effect and white coat hypertension in community pharmacy practice
Botomino, A., Martina, B. E. E., Ruf, D., Bruppacher, R., & Hersberger, K. E. (2005) · Blood Pressure Monitoring · doi:10.1097/00126097-200502000-00004 · Cited by 16
Eguchi, K., Kuruvilla, S., Ishikawa, J., Ogedegbe, G. G., Gerin, W., Schwartz, J. E., & Pickering, T. G. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328346d669 · Cited by 16
Effects of bell versus diaphragm on indirect blood pressure measurement.
Mauro, A. M. (1988) · PubMed · Cited by 15
Arm Position and Blood Pressure Measurement
Hemingway, T. J., Guss, D. A., & Abdelnur, D. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-1-200401060-00037 · Cited by 15
Carretta, R., Fabris, B., Bardelli, M., Muiesan, S., Fischetti, F., Cesanelli, R., Pizzolitto, A., Bianchetti, A., & Campanacci, L. (1988) · Cardiovascular Research · doi:10.1093/cvr/22.3.226 · Cited by 15
Reinders, L. W., Mos, C. N., Thornton, C. E., Ogle, R. F., Makris, A., Child, A., & Hennessy, A. (2006) · Hypertension in Pregnancy · doi:10.1080/10641950600745228 · Cited by 15
Automated Blood Pressure Recording: The Phenomenon of Blood Pressure Elevations During Speech
Malinow, K. L., Lynch, J. J., Thomas, S. A., Friedmann, E., & Long, J. M. (1982) · Angiology · doi:10.1177/000331978203300707 · Cited by 15
Familoni, O. B., & Olunuga, T. O. (2005) · Cardiovascular journal of South Africa · Cited by 14
The effect of clothes on sphygmomanometric blood pressure measurement in hypertensive patients
Pınar, R., Ataalkin, S., & Watson, R. A. (2010) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2010.03224.x · Cited by 14
The effect of crossing legs on blood pressure in hypertensive patients
Pınar, R., Ataalkin, S., & Watson, R. A. (2010) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2009.03148.x · Cited by 14
Lyratzopoulos, G., Heller, R. F., Hanily, M., & Lewis, P. (2007) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2007.05.020 · Cited by 14
Blood Pressure Measurements in the Nursing Home: Are They Accurate?
Stoneking, H. T., Hla, K. M., Samsa, G. P., & Feussner, J. R. (1992) · The Gerontologist · doi:10.1093/geront/32.4.536 · Cited by 14
Acute haemodynamic effects of cigarette smoking in healthy young subjects
Amir, Z., Mahmud, A., & Feely, J. (2006) · Irish Journal of Medical Science (1971 -) · doi:10.1007/bf03169167 · Cited by 14
Validation of Heine Gamma G7 (G5) and XXL-LF aneroid devices for blood pressure measurement
Dorigatti, F., Bonso, E., Zanier, A., & Palatini, P. (2007) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000217997.19839.39 · Cited by 14
Sphygmomanometer calibration: a survey of one inner-city primary care group
Ashworth, M. J., Gordon, K., Baker, G., & Deshmukh, A. (2001) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001172 · Cited by 14
Wang, Y., Wang, Y., Qain, Y., Zhang, J., Tang, X., Sun, J., & Zhu, D. (2014) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000092 · Cited by 14
Sphygmomanometers: errors due to blocked vents.
Shaw, A., Deehan, C., & Lenihan, J. M. (1979) · BMJ · doi:10.1136/bmj.1.6166.789 · Cited by 13
Direct and Indirect Blood Pressure In Critical Care Patients
Byra-Cook, C. J., Dracup, K., & LAZIK, A. J. (1990) · Nursing Research · doi:10.1097/00006199-199009000-00006 · Cited by 13
Blanco, F., Gil, P., del Arco, C., Sáez, T., Aguilar, R., Lara, I. I. D., de la Cruz, J. J., Gabriel, R., & Suárez, C. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000218010.11323.b3 · Cited by 13
Koutnik, A. P., Figueroa, A., Wong, A., Ramirez, K. J., Ormsbee, M. J., & Sanchez‐Gonzalez, M. A. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-2897-7 · Cited by 13
Systemic and renal effect of nicotine in non-smokers
Halimi, J., & Mimran, A. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018110-00019 · Cited by 13
Effects of arm position and support on blood-pressure readings.
Waal-Manning, H. J., & Paulin, J. M. (1987) · PubMed · Cited by 13
Fifth Versus Fourth Korotkoff Phase
Londe, S. (1985) · PEDIATRICS · doi:10.1542/peds.76.3.460 · Cited by 12
Beck, F. M., Weaver, J. M., Blozis, G. G., & Unverferth, D. V. (1983) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1983.0146 · Cited by 12
Niyonsenga, T., Vanasse, A., Courteau, J., & Cloutier, L. (2008) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2008.06620.x · Cited by 12
Clinical evaluation of the Trimline blood pressure cuffs with the Accutorr PlusTM Monitor
White, W. B., Herbst, T., Thavarajah, S., & Giacco, S. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200306000-00008 · Cited by 12
Jenner, D. A., Beilin, L. J., Vandongen, R., & de Klerk, N. H. (1988) · Clinical and Experimental Hypertension · doi:10.3109/10641968809033910 · Cited by 12
Accuracy and performance of the terumo es-h51, a new portable blood pressure monitor
Imai, Y. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(95)94790-c · Cited by 12
In-office assessment of blood pressure in chronic kidney disease
O'Shaughnessy, M. M., Newman, C. A., Kinsella, S. M., Reddan, D. N., & Lappin, D. W. P. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328346e0db · Cited by 12
Expressions of accuracy in the evaluation of biomedical instrumentation.
Ns, L., & Lanier, R. (1998) · PubMed · Cited by 12
Accuracy and Performance of the Terumo ES-H51, a New Portable Blood Pressure Monitor
Imai, Y., Hashimoto, J., Minamt, N., Munakata, M., Watanabe, N., Sakuma, H., SEKINO, H., & Abe, K. (1994) · American Journal of Hypertension · doi:10.1093/ajh/7.3.255 · Cited by 12
Serial blood pressure measurements
Koehler, N. R., Poli‐de‐Figueiredo, C. E., & Ribeiro, A. C. M. (2002) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2002000500007 · Cited by 11
BLOOD PRESSURE ERRORS WITH ANEROID SPHYGMOMANOMETERS
Bowman, C. (1981) · The Lancet · doi:10.1016/s0140-6736(81)91776-1 · Cited by 11
Automatic office blood pressure measured without doctors or nurses present
Ishikawa, J., Nasothimiou, E. G., Karpettas, N., McDoniel, S. O., Feltheimer, S. D., Stergiou, G. S., Pickering, T. G., & Schwartz, J. E. (2012) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328352ade4 · Cited by 11
Wang, S., Majumdar, S. R., & Padwal, R. S. (2014) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000087 · Cited by 11
Silveira, A., Mesquita, A., Maldonado, J. M. P., Silva, J. A., & Polónia, J. J. (2002) · PubMed · Cited by 11
Effect of one leg crossed over the other at the knee on blood pressure in hypertensive patients.
Avvampato, C. S. (2001) · PubMed · Cited by 10
Braam, R. L., de Maat, C., & Thien, T. A. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200206000-00007 · Cited by 10
Kuo, C., Hwu, C., Kwok, C., Hsiao, L.-C., Weih, M. J., Lee, S.-H., & Ho, L.-T. (2000) · Journal of Diabetes and its Complications · doi:10.1016/s1056-8727(00)00125-2 · Cited by 10
Auditing the technology used to measure blood pressure
Amoore, J., Guehenec, M., Scordecchia, R., & Scott, D. H. T. (2010) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903518991 · Cited by 10
Talking Effect and White Coat Phenomenon in Hypertensive Patients
Pailleur, C. L., Vacheron, A., Landais, P., Mounier‐Véhier, C., Feder, J. M., Montgermont, P., Jaïs, J., & Metzger, J. P. (1996) · Behavioral Medicine · doi:10.1080/08964289.1996.9933772 · Cited by 10
The Accuracy of Aneroid Sphygmomanometers in the Ambulatory Setting
Moore, T. A., Sorokin, A. V., Hirst, C. S., Thornton‐Thompson, S., & Thompson, P. D. (2008) · Preventive Cardiology · doi:10.1111/j.1751-7141.2008.06600.x · Cited by 10
Saladini, F., Benetti, E., Malipiero, G., Casiglia, E., & Palatini, P. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283589ee6 · Cited by 10
Does the accuracy of blood pressure measurement correlate with hearing loss of the observer?
Song, S., Lee, J., Chee, Y., Jang, D. P., & Kim, I. Y. (2013) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000016 · Cited by 10
Lebeau, J., Pouchain, D., Huas, D., Wilmart, F., Dibao-Dina, C., & Boutitie, F. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328344d067 · Cited by 10
Reinders, A., Jones, C. R., Cuckson, A. C., & Shennan, A. H. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200304000-00005 · Cited by 10
Reed, T. E., & Hanna, J. M. (1986) · Behavior Genetics · doi:10.1007/bf01066285 · Cited by 9
Cavalcanti, S., Marchesi, G., & Ghidini, C. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344696 · Cited by 9
Effect of bladder distension on blood pressure
Scultéty, S., Varga, B., & Szabó, D. (1971) · International Urology and Nephrology · doi:10.1007/bf02081793 · Cited by 9
Efstratopoulos, A. D., & Voyaki, S. M. (1993) · Journal of Hypertension · doi:10.1097/00004872-199312050-00035 · Cited by 9
Can Pulse Pressure Predict the White-Coat Effect in Treated Hypertensive Patients?
Yoon, H. J., Ahn, Y., Kim, K. H., Park, J. C., Park, J. B., Park, C. G., Youn, H., Choi, D., Shin, J., Kim, D.-W., et al. (2012) · Clinical and Experimental Hypertension · doi:10.3109/10641963.2012.681725 · Cited by 8
Interarm Blood Pressure Differences in the Women's Interagency HIV Study
Lazar, J., Holman, S., MINKOFF, H. L., DeHovitz, J. A., & Sharma, A. (2007) · AIDS Research and Human Retroviruses · doi:10.1089/aid.2007.0237 · Cited by 8
Odili, A. N., Ameh, V. O., Ogedengbe, J. O., & Staessen, J. A. (2014) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000053 · Cited by 8
Walker, S. P., Higgins, J. R., & Brennecke, S. P. (1998) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1998.tb140223.x · Cited by 8
Weber, F. P., Lindemann, M., Erbel, R. M., & Philipp, T. (1999) · Kidney & Blood Pressure Research · doi:10.1159/000025924 · Cited by 7
Weber, F. P., Anlauf, M., Hirche, H., Roggenbuck, U., & Philipp, T. (1999) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000891 · Cited by 7
Validation of an oscillometric electronic sphygmomanometer in an obstetric population
Kwek, K., CHAN, Y., Tan, K. H., & Yeo, G. S. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00093-4 · Cited by 7
An Evaluation of Three Blood Pressure Methods in a Stabilized Acute Trauma Population
Norman, E. M., GADALETA, D., & Griffin, C. (1991) · Nursing Research · doi:10.1097/00006199-199103000-00005 · Cited by 7
Hand‐free stethoscope — method and instrument for more reliable blood pressure measurements
Ljungvall, P., & Thulin, T. (1991) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1991.tb00433.x · Cited by 7
Caffeine increases aortic stiffness in hypertensive patients
Vlachopoulos, C. V. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02292-6 · Cited by 7
Bern, L., Brandt, M., Mbelu, N., Asonye, U., Fisher, T., Shaver, Y., & Serrill, C. (2007) · PubMed · Cited by 6
Prakash, R., & Kaushik, V. S. (1988) · PubMed Central · Cited by 6
Haigh, R. A., Harper, G. D., Fotherby, M. D., Hurd, J., Macdonald, I. A., & Potter, J. F. (1993) · European Journal of Clinical Pharmacology · doi:10.1007/bf02440857 · Cited by 6
ACCURACY OF THE TAKEDA TM‐2420 AMBULATORY BLOOD PRESSURE MONITOR
Russell, A. E., Tonkin, A., Wing, L. M. H., HASSAM, R. M., McRitchie, R. J., Aylward, P. E., Minson, R. B., Bune, A. J. C., West, M., & Chalmers, J. P. (1989) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1989.tb01553.x · Cited by 6
The extent of inaccurate aneroid sphygmomanometers in a hospital setting
Cozanitis, D. A., & Jones, C. J. (2010) · Wiener Medizinische Wochenschrift · doi:10.1007/s10354-010-0741-1 · Cited by 5
McShane, J. B. (1988) · Science and Children · Cited by 5
Başak, O., & Karazeybek, Ş. (1999) · DergiPark · Cited by 5
An evaluation of the Takeda UA751 automatic sphygmomanometer
Johnston, D. W., & Shah, D. J. M. (1989) · Behaviour Research and Therapy · doi:10.1016/0005-7967(89)90080-6 · Cited by 5
Agreement between Emergency Medical Services and Expert Blood Pressure Measurements
Cienki, J. J., & DeLuca, L. (2011) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2011.02.018 · Cited by 5
Sphygmomanometers--an audit in general practice.
Shah, N. C., Sibbritt, D. W., Heaney, S. E., & Sharples, J. (2004) · PubMed · Cited by 5
The Validity of Emergency Department Triage Blood Pressure Measurements
Cienki, J. J. (2004) · Academic Emergency Medicine · doi:10.1197/j.aem.2003.10.021 · Cited by 5
Clinical validation of aneroid sphygmomanometer.
Saxena, Y., Saxena, V., & Gupta, R. (2012) · PubMed · Cited by 4
Handler, J. (2008) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2008.08064.x · Cited by 4
Acute effects of smoking on coronary flow velocity reserve and ventricular diastolic functions
Kaşıkçıoğlu, E., Elitok, A., Önür, İ., Çimen, A. O., Uçar, A., & Oflaz, H. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.06.086 · Cited by 4
Gu, J., Wang, J., Huang, Q., & Zhu, S. (2012) · Postgraduate Medicine · doi:10.3810/pgm.2012.03.2536 · Cited by 4
Malatino, L., & Brown, W. C. (1988) · Clinical and Experimental Hypertension · doi:10.3109/10641968809033911 · Cited by 4
Ambulatory blood pressure in 570 Danes aged 19–21 years: the Odense Schoolchild Study
Lambrechtsen, J., Rasmussen, F., Hansen, H., & Jacobsen, I. (1998) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000704 · Cited by 4
Acute pulmonary effects of smoking a reference cigarette
Diamond, L., Lipscomb, W., & Johnson, R. (1971) · Toxicology and Applied Pharmacology · doi:10.1016/s0041-008x(71)80018-2 · Cited by 3
Dawson, A. J., Middlemiss, C., & Vanner, T. (1989) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(89)90207-4 · Cited by 3
Cartwright, C., Unwin, N. C., & Stephenson, P. (1996) · Journal of Epidemiology & Community Health · doi:10.1136/jech.50.2.218 · Cited by 3
Validação do esfigmomanômetro aneroide Missouri para medir pressão arterial em pacientes com câncer
Ferreira, K. A. S. L., dos Santos, A. C., Arthur, T., dos Santos, D. A. A., Pereira, D., Freitas, E. O., Fukuda, F. M., & Baia, W. R. M. (2010) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2010005000093 · Cited by 2
Differences in Manual and Automatic Blood Pressures in Telemetry Patients With Atrial Fibrillation
Collins, M., Cummings, A., Skaggs, C., Weller, R., & Cronin, S. N. (2013) · Dimensions of Critical Care Nursing · doi:10.1097/dcc.0b013e3182a07716 · Cited by 2
Does This Patient Have Hypertension?
Reeves, R. A. (1995) · JAMA · doi:10.1001/jama.1995.03520390071036
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“The use of an inaccurate measurement technique is common, and a systematic review found a large bias associated with 27 of 29 potential sources of BP measurement error.(16) Table 1 lists key components of observer training for BP measurement.”
BackgroundMethodInfluentialCheung, A. K., Chang, T. I., Cushman, W. C., Furth, S. L., Hou, F. F., Ix, J. H., Knoll, G. A., Muntner, P., Pecoits-Filho, R., Sarnak, M. J., et al. (2021) · Kidney International · doi:10.1016/j.kint.2020.11.003 · Cited by 1,452
Nerenberg, K. A., Zarnke, K. B., Leung, A. A., Dasgupta, K., Butalia, S., McBrien, K., Harris, K. C., Nakhla, M., Cloutier, L., Gelfer, M., et al. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.02.022 · Cited by 573
Shimbo, D., Artinian, N. T., Basile, J. N., Krakoff, L. R., Margolis, K. L., Rakotz, M. K., Wozniak, G., & On behalf of the American Heart Association and the American Medical Association (2020) · Circulation · doi:10.1161/cir.0000000000000803 · Cited by 389
Metadata
- Authors
- Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O.
- Affiliations
- The University of Queensland (AU)
- Metro North Hospital and Health Service (AU)
- Corresponding author
- Hill, Andrew
- Venue
- Journal of Hypertension
- Published
- 2017-03
- Volume
- 35
- Issue
- 3
- Pages
- 421-441
- ISSN
- 0263-6352 (ISSN-L)
- PMC
- PMC5278896
- OpenAlex
- W2563521117
- Semantic Scholar
- 17b4fd73a6b155571b2a3a3aee7dbbd6bc78909a
- Cited by
- 357
- References
- 390
- Citations by year
- 2026: 34 · 2025: 46 · 2024: 45 · 2023: 45 · 2022: 45 · 2021: 46 · 2020: 41 · 2019: 28 · 2018: 21 · 2017: 6
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of Hypertension (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Funders
- University of Queensland
- Metro North Hospital and Health Service
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- blood pressure measurement, measurement error, resting blood pressure, upper arm blood pressure, measurement variability, clinical deterioration, blood pressure monitoring, measurement error sources, blood pressure interpretation
- MeSH terms
- Alcohol Drinking, Arm, Urinary Bladder, Blood Pressure, Blood Pressure Determination, Caffeine, Cold Temperature, Eating, Humans, Hypertension, Nicotine, Rest, Reproducibility of Results, White Coat Hypertension, Tobacco Use
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.