A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement
Open accessAbstract
: In the last 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and the International Organization for Standardization (ISO) have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers and manufacturers would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by AAMI, ESH and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“in the last three decades, the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on BP Monitoring and the International Organization for Standardization (ISO), have developed protocols for clinical validation of BP-measuring devices [88].”
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Using a small bladder (undercuffing) is common in obese adults and leads to overestimation of BP”
From Home blood pressure monitoring: methodology, clinical relevance and practical application: a 2021 position paper by the Working Group on Blood Pressure Monitoring and Cardiovascular Variability of the European Society of Hypertension (2021) · cites this paper as [90]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“whereas using a larger cuff (overcuffing) is common in children and leads to BP underestimation [4,90,98,99].”
From Home blood pressure monitoring: methodology, clinical relevance and practical application: a 2021 position paper by the Working Group on Blood Pressure Monitoring and Cardiovascular Variability of the European Society of Hypertension (2021) · cites this paper as [90]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Unfortunately, most of the devices available on the market have not been subjected to independent validation using one of these protocols [69,87–89].”
From Home blood pressure monitoring: methodology, clinical relevance and practical application: a 2021 position paper by the Working Group on Blood Pressure Monitoring and Cardiovascular Variability of the European Society of Hypertension (2021) · cites this paper as [88]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brien, E. O., Petrie, J. C., Littler, W. A., de Swiet, M., Padfield, P. L., O??Malley, K., Jamieson, M., Altman, D. G., Bland, M., & Atkins, N. (1990) · Journal of Hypertension · doi:10.1097/00004872-199007000-00004 · Cited by 764
Self-citationO'Brien, E. T., Pickering, T. G., Asmar, R. G., Myers, M. G., Parati, G., Staessen, J. A., Mengden, T., Imai, Y., Waeber, B., Palatini, P., et al. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00002 · Cited by 735
Self-citationO'Brien, E. T., Atkins, N., Stergiou, G. S., Karpettas, N., Parati, G., Asmar, R. G., Imai, Y., Wang, J., Mengden, T., & Shennan, A. H. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283360e98 · Cited by 609
Self-citationBrien, E. O., Petrie, J. C., Little, W. C., de Swiet, M., Padfield, P. L., Altma, D. G., Bland, M., Coats, A. J. S., & Atkins, N. (1993) · Journal of Hypertension · doi:10.1097/00004872-199306000-00013 · Cited by 518
Self-citationStergiou, G. S., Karpettas, N., Atkins, N., & O'Brien, E. T. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283360eaf · Cited by 63
Self-citationAccuracy of ambulatory blood pressure monitors
Hodgkinson, J., Sheppard, J. P., Heneghan, C. J., Martin, U., Mant, J., Roberts, N. W., & McManus, R. J. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835b8d8b · Cited by 45
Self-citationAssessment of the validation of blood pressure monitors: a statistical reappraisal.
Friedman, B. A., Alpert, B., Osborn, D., Prisant, L., Quinn, D. I., & Seller, J. D. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283071a64 · Cited by 44
Self-citationThe pursuit of accurate blood pressure measurement: A 35‐year travail
O'Brien, E., & Stergiou, G. S. (2017) · The Journal of Clinical Hypertension · doi:10.1111/jch.13005 · Cited by 39
Self-citationTholl, U., Lüders, S., Bramlage, P., Dechend, R., Eckert, S., Mengden, T., Nürnberger, J., Sanner, B. M., & Anlauf, M. (2016) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000186 · Cited by 33
Self-citationO'Brien, E. T. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200002000-00010 · Cited by 23
Self-citation
Research works printed but not linked: 1
- O’Brien, 1993, The British Hypertension Society protocol for the evaluation of blood pressure measuring devices, J Hypertens, 11, S43
Cited by
Sorted by citations
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Self-citationMancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Self-citationWilliams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Self-citationDiretrizes Brasileiras de Hipertensão Arterial – 2020
Barroso, W. K. S., Rodrigues, C. I. S., Bortolotto, L. A., Gomes, M. A. M., Brandão, A. A., Feitosa, A. D. M., Machado, C. A., Poli‐de‐Figueiredo, C. E., Amodeo, C., Mion, D., et al. (2021) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20201238 · Cited by 1,389
Stergiou, G. S., Palatini, P., Parati, G., O’Brien, E., Januszewicz, A., Lurbe, E., Persu, A., Mancia, G., Kreutz, R., & on behalf of the European Society of Hypertension Council and the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002843 · Cited by 859
Self-citationBrouwers, S., Sudano, I., Kokubo, Y., & Sulaica, E. M. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00221-x · Cited by 297
Sharman, J. E., Avolio, A. P., Baulmann, J., Benetos, A., Blacher, J., Blizzard, C. L., Boutouyrie, P., Chen, C.-H., Chowienczyk, P., Cockcroft, J. R., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehw632 · Cited by 231
Self-citationStergiou, G. S., Mukkamala, R., Avolio, A. P., Kyriakoulis, K. G., Mieke, S., Murray, A., Parati, G., Schutte, A. E., Sharman, J. E., Asmar, R. G., et al. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003224 · Cited by 231
Self-citationContinuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos
Kireev, D., Sel, K., Ibrahim, B., Kumar, N., Akbari, A., Jafari, R., & Akinwande, D. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01145-w · Cited by 249
Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals
Mukkamala, R., Yavarimanesh, M., Natarajan, K., Hahn, J.-O., Kyriakoulis, K. G., Avolio, A. P., & Stergiou, G. S. (2021) · Hypertension · doi:10.1161/hypertensionaha.121.17747 · Cited by 211
Self-citationA Review on the Role of Machine Learning in Enabling IoT Based Healthcare Applications
Bharadwaj, H. K., Agarwal, A., Chamola, V., Lakkaniga, N. R., Hassija, V., Guizani, M., & Sikdar, B. (2021) · IEEE Access · doi:10.1109/access.2021.3059858 · Cited by 208
Parati, G., Stergiou, G. S., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Agarwal, R., Asayama, K., Asmar, R., Burnier, M., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002922 · Cited by 178
Self-citationWearable Digital Health Technologies for Monitoring in Cardiovascular Medicine
Spatz, E. S., Ginsburg, G. S., Rumsfeld, J. S., & Turakhia, M. P. (2024) · New England Journal of Medicine · doi:10.1056/nejmra2301903 · Cited by 166
Stergiou, G. S., Avolio, A. P., Palatini, P., Kyriakoulis, K. G., Schutte, A. E., Mieke, S., Κόλλιας, Α., Parati, G., Asmar, R. G., Pantazis, N., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003483 · Cited by 150
Self-citationDrapkina, O. M., Васильевна, К. А., Калинина, А. М., Avdeev, S. M., Викторович, А. М., Alexandrova, L. M., Анциферова, А. А., Dm, A., Ахмеджанов, Н. М., Balanova, Y. А., et al. (2022) · CARDIOVASCULAR THERAPY AND PREVENTION · doi:10.15829/1728-8800-2022-3235 · Cited by 197
Athaya, T., & Choi, S. (2021) · Sensors · doi:10.3390/s21051867 · Cited by 137
2024 Recommendations for Validation of Noninvasive Arterial Pulse Wave Velocity Measurement Devices
Spronck, B., Terentes-Printzios, D. G., Avolio, A. P., Boutouyrie, P., Guala, A., Jerončić, A., Laurent, S., Barbosa, E. C. D., Baulmann, J., Chen, C., et al. (2023) · Hypertension · doi:10.1161/hypertensionaha.123.21618 · Cited by 111
John, O., Campbell, N. R. C., Brady, T. M., Farrell, M., Varghese, C. V., Berumen, A. V., Gaitán, L. A. U., Toffelmire, N., Ameel, M., Mideksa, M., et al. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16625 · Cited by 100
Xing, X., Ma, Z., Zhang, M., Zhou, Y., Dong, W., & Song, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-45175-2 · Cited by 101
Validation protocols for blood pressure measuring devices in the 21st century
Stergiou, G. S., Alpert, B. S., Mieke, S., Wang, J., & O'Brien, E. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13294 · Cited by 92
Self-citationVybornova, A., Polychronopoulou, E., Wurzner-Ghajarzadeh, A., Fallet, S., Solà, J., & Wuerzner, G. (2021) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000531 · Cited by 87
Assessment of deep learning based blood pressure prediction from PPG and rPPG signals
Schrumpf, F., Frenzel, P., Aust, C., Osterhoff, G., & Fuchs, M. (2021) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw53098.2021.00423 · Cited by 70
The assessment of blood pressure in pregnant women: pitfalls and novel approaches
Hurrell, A., Webster, L., Chappell, L. C., & Shennan, A. H. (2021) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.10.026 · Cited by 66
Self-citationCuff-Less Blood Pressure Monitoring System Using Smartphones
Tabei, F., Gresham, J. M., Askarian, B., Jung, K., & Chong, J. W. (2020) · IEEE Access · doi:10.1109/access.2020.2965082 · Cited by 64
Cuffless Blood Pressure Estimation Using Single Channel Photoplethysmography: A Two-Step Method
Khalid, S. G., Liu, H., Zia, T., Zhang, J., Chen, F., & Zheng, D. (2020) · IEEE Access · doi:10.1109/access.2020.2981903 · Cited by 61
Clinical practice guideline for the management of hypertension in China
Chinese Society of Cardiology, C. M. A., Hypertension Committee of Cross-Straits Medicine Exchange Association, & Cardiovascular Disease Prevention and Rehabilitation Committee, C. A. O. R. M. (2024) · Chinese Medical Journal · doi:10.1097/cm9.0000000000003431 · Cited by 66
Improving the accuracy of blood pressure measurement
Stergiou, G. S., Asmar, R. G., Myers, M. G., Palatini, P., Parati, G., Shennan, A. H., Wang, J., & O'Brien, E. T. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001635 · Cited by 56
Self-citationOrdúñez, P., Campbell, N. R. C., Arcila, G. P. G., Angell, S. Y., Lombardi, C., Brettler, J. W., Morales, Y. A. R., Connell, K., Gamarra, Á., DiPette, D. J., et al. (2022) · Revista Panamericana de Salud Pública · doi:10.26633/rpsp.2022.96 · Cited by 52
A Review of Noninvasive Methodologies to Estimate the Blood Pressure Waveform
Athaya, T., & Choi, S. (2022) · Sensors · doi:10.3390/s22103953 · Cited by 58
Optimal Control of SonoVue Microbubbles to Estimate Hydrostatic Pressure
Nio, A. Q. X., Faraci, A., Christensen-Jeffries, K. M., Raymond, J. L., Monaghan, M. J., Fuster, D., Forsberg, F., Eckersley, R. J., & Lamata, P. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2948759 · Cited by 48
Lin, H., Wang, T., Chen, M. Y., Hsu, C., Wang, K.-L., Huang, C., Hsieh, M., Chiu, Y.-W., Chiang, L.-T., Chuang, W.-P., et al. (2020) · PubMed Central · doi:10.6515/acs.202011_36(6).20201106a · Cited by 40
Self-citationKario, K., Williams, B., Tomitani, N., McManus, R. J., Schutte, A. E., Avolio, A. P., Shimbo, D., Wang, J., Khan, N. A., Picone, D. S., et al. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003827 · Cited by 41
Self-citationGMM-HMM-Based Blood Pressure Estimation Using Time-Domain Features
Celler, B. G., Le, P. N., Argha, A., & Eliathamby Ambikairajah, A. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2937074 · Cited by 38
Pellaton, C., Vybornova, A., Fallet, S., Marques, L., Grossenbacher, O., Marco, B. D., Chapuis, V., Bertschi, M., Alpert, B. S., & Solà, J. (2019) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000421 · Cited by 38
Self-citationCuffless Blood Pressure Measurement Devices—International Perspectives on Accuracy and Clinical Use
Yang, E., Schutte, A. E., Stergiou, G. S., Wyss, F. S., Commodore-Mensah, Y. Y., Odili, A. N., Kronish, I. M., Lee, H.-Y., & Shimbo, D. (2025) · JAMA Cardiology · doi:10.1001/jamacardio.2025.0662 · Cited by 40
Self-citationCentral aortic blood pressure estimation in children and adolescents: results of the KidCoreBP study
Mynard, J. P., Goldsmith, G., Springall, G. A. C., Eastaugh, L., Lane, G. K., Zannino, D., Smolich, J. J., Avolio, A. P., & Cheung, M. M. H. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002338 · Cited by 35
Accelerated vascular ageing after COVID-19 infection: the CARTESIAN study
Bruno, R. M., Badhwar, S., Abid, L., Agharazii, M., Anastasio, F., Bellien, J., Burghuber, O., Faconti, L., Filipovský, J., Ghiadoni, L., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf430 · Cited by 34
Eisen, H. J., Flack, J. M., Atluri, P., Bansal, N., Breathett, K. K., Brown, A. L., Hankins, S. R., Khazanie, P., Masri, C., Pirlamarla, P. R., et al. (2022) · Circulation Heart Failure · doi:10.1161/hhf.0000000000000074 · Cited by 32
Estándares SEA 2022 para el control global del riesgo cardiovascular
Mostaza, J. M., Pintó, X., Armario, P., Masana, L., Real, J. T., Valdivielso, P., Arrobas-Velilla, T., Baeza‐Trinidad, R., Calmarza, P., Cebollada, J., et al. (2022) · Clínica e Investigación en Arteriosclerosis · doi:10.1016/j.arteri.2021.11.003 · Cited by 43
Zhang, W., Zhou, Y.-N., Zhou, Y., & Wang, J. (2022) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000608 · Cited by 31
Self-citationCovid-19 Effects on ARTErial StIffness and Vascular AgeiNg: CARTESIAN Study Rationale and Protocol
Bruno, R. M., Spronck, B., Hametner, B., Hughes, A. D., Lacolley, P. J., Mayer, C. C., Muiesan, M. L., Rajkumar, C., Terentes-Printzios, D. G., Weber, T., et al. (2020) · Artery Research · doi:10.2991/artres.k.201124.001 · Cited by 35
The Promise and Illusion of Continuous, Cuffless Blood Pressure Monitoring
Hu, J., Park, D. Y., Agarwal, N., Herzig, M. S., Ormseth, G., Kaushik, M., Giao, D. M., Turkson‐Ocran, R., & Juraschek, S. P. (2023) · Current Cardiology Reports · doi:10.1007/s11886-023-01932-4 · Cited by 30
Non-invasive continuous blood pressure sensors in biomedical engineering research: A review
Samartkit, P., & Pullteap, S. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115084 · Cited by 32
Villar, R., Sánchez, R. A., Boggia, J., Peñaherrera, E., Lopez, J., Barroso, W. S., Barbosa, E., Cobos, L., Hernández Hernández, R., Octavio, J. A., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.13815 · Cited by 28
Self-citationSkelding, A., & Valverde, A. (2020) · PubMed · Cited by 28
Sakhuja, S., Jaeger, B. C., Akinyelure, O. P., Bress, A. P., Shimbo, D., Schwartz, J. E., Hardy, S. T., Howard, G., Drawz, P., & Muntner, P. (2022) · The Journal of Clinical Hypertension · doi:10.1111/jch.14418 · Cited by 28
Rachim, V. P., Kang, S., Baek, J., & Park, S. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3059864 · Cited by 27
An Improved UNet++ Model for Congestive Heart Failure Diagnosis Using Short-Term RR Intervals
Lei, M., Li, J., Li, M., Zou, L., & Yu, H. (2021) · Diagnostics · doi:10.3390/diagnostics11030534 · Cited by 26
Campbell, N. R. C., Padwal, R. S., Picone, D. S., Su, H., & Sharman, J. E. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13915 · Cited by 26
Improving Cuff-Less Continuous Blood Pressure Estimation with Linear Regression Analysis
Figini, V., Galici, S., Russo, D., Centonze, I., Visintin, M., & Pagana, G. (2022) · Electronics · doi:10.3390/electronics11091442 · Cited by 25
Estándares SEA 2019 para el control global del riesgo cardiovascular
Mostaza, J. M., Pintó, X., Armario, P., Masana, L., Ascaso, J. F., Valdivielso, P., Velilla, T. A., Brea, Á., Calmarza, P., Cebollada, J., et al. (2019) · Clínica e Investigación en Arteriosclerosis · doi:10.1016/j.arteri.2019.03.004 · Cited by 36
G. Celler, B., Butlin, M., Argha, A., Tan, I., Yong, A., & Avolio, A. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3079578 · Cited by 24
Achieving reliable blood pressure measurements in clinical practice: It's time to meet the challenge
O'Brien, E. T., Dolan, E., & Stergiou, G. S. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13323 · Cited by 23
Self-citationAlexandre, J., Tan, K., de Almeida, T. P., Solà, J., Alpert, B. S., & Shah, J. (2023) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000639 · Cited by 23
Self-citationStergiou, G. S., Menti, A., Asayama, K., de la Sierra, A., Wang, J., Kinoshita, H., Sawanoi, Y., Yamashita, S., Κόλλιας, Α., Wu, C. O., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003403 · Cited by 24
Self-citationTopouchian, J. A., Hakobyan, Z., Asmar, J. T., Sv, G., Zelveian, P., & Asmar, R. G. (2018) · Vascular Health and Risk Management · doi:10.2147/vhrm.s165524 · Cited by 21
Self-citationChazova, I. E., Михайловна, Ч. Н., Blinova, N. V., Владимировна, А. А., Alekseeva, T. A., Ambatiello, L. G., Balanova, Y. А., Bragina, A. E., Danilov, N. M., Drapkina, O. M., et al. (2024) · Systemic Hypertension · doi:10.38109/2075-082x-2024-4-5-109 · Cited by 23
Peprah, Y. A., Lee, J. Y., & Persell, S. D. (2023) · Journal of Human Hypertension · doi:10.1038/s41371-022-00795-6 · Cited by 23
Asayama, K., Stolarz‐Skrzypek, K., Yang, W., Hansen, T. W., Brguljan-Hitij, J., Odili, A. N., Li, Y., & Staessen, J. A. (2023) · Hypertension Research · doi:10.1038/s41440-023-01191-4 · Cited by 24
Noninvasive Continuous Blood Pressure Measurement with Wearable Millimeter Wave Device
Liao, C., Shay, O., Gomes, E., & Bikhchandani, N. (2021) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn51625.2021.9507020 · Cited by 19
How to find and use validated blood pressure measuring devices
Picone, D. S., Padwal, R. S., Stergiou, G. S., Cohen, J. B., McManus, R. J., Eckert, S., Asayama, K., Atkins, N., Rakotz, M., Lombardi, C., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00718-5 · Cited by 19
Self-citationThe quest for accuracy of blood pressure measuring devices
O'Brien, E., Stergiou, G. S., & Turner, M. J. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13279 · Cited by 18
Self-citationOdette, O. (2024) · Wiley eBooks · doi:10.1002/9781119830306.ch12 · Cited by 18
Topouchian, J. A., Zelveian, P., Hakobyan, Z., Gharibyan, H., & Asmar, R. G. (2022) · Vascular Health and Risk Management · doi:10.2147/vhrm.s350006 · Cited by 17
Self-citationZhou, Y., Zhang, W., Wang, X., Zhou, Y., Li, Y., & Wang, J. (2025) · Hypertension Research · doi:10.1038/s41440-025-02345-2 · Cited by 18
Self-citationOrdúñez, P., Campbell, N. R. C., Arcila, G. P. G., Angell, S. Y., Lombardi, C., Brettler, J. W., Morales, Y. A. R., Connell, K., Gamarra, Á., DiPette, D. J., et al. (2022) · Revista Panamericana de Salud Pública · doi:10.26633/rpsp.2022.197 · Cited by 16
Nachman, D., Eisenkraft, A., Goldstein, N., Ishay, A. B., Fons, M., Merin, R., & Gepner, Y. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.911544 · Cited by 16
Stergiou, G. S., Parati, G., Κόλλιας, Α., Schutte, A. E., Asayama, K., Asmar, R. G., Bilo, G., de la Sierra, A., Dolan, E., Filipovský, J., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003482 · Cited by 16
Self-citationLee, W. L., Danaee, M., Abdullah, A. B., & Wong, L. P. (2023) · Cardiology Research · doi:10.14740/cr1569 · Cited by 17
Stergiou, G. S., Kyriakoulis, K. G., Κόλλιας, Α., McManus, R. J., Menti, A., Parati, G., Schutte, A. E., Wang, J.-G., Asayama, K., Asmar, R. G., et al. (2025) · Journal of Hypertension · doi:10.1097/hjh.0000000000003965 · Cited by 17
Self-citationAccurate blood pressure measuring devices: Influencing users in the 21st century
O'Brien, E. T., Alpert, B. S., & Stergiou, G. S. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13278 · Cited by 15
Self-citationÖsterreichischer Blutdruckkonsens 2019
Hypertensiologie, Ö. G. F., Weber, T., Atherosklerosegesellschaft, Ö., Gesellschaft, Ö. D., Angiologie, Ö. G. F. I., Nephrologie, Ö. G. F., Gesellschaft, Ö. K., Neurologie, Ö. G. F., Schlaganfall-Gesellschaft, Ö., Allgemeinmedizin, Ö. G. F., et al. (2019) · Wiener klinische Wochenschrift · doi:10.1007/s00508-019-01565-0 · Cited by 15
Athaya, T., & Choi, S. (2022) · Biosensors · doi:10.3390/bios12080655 · Cited by 15
Saito, K., Hishiki, Y., & Takahashi, H. (2020) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000437 · Cited by 16
Zhang, Y., Qiu, S., Du, K., Wu, S. P., Xiang, T., Zheng, K., Liu, Z., Chen, H., Ji, N., Wang, F., et al. (2026) · Nano-Micro Letters · doi:10.1007/s40820-025-02003-9 · Cited by 18
Antenatal Programming of Hypertension: Paradigms, Paradoxes, and How We Move Forward
South, A. M., & Allen, N. B. (2022) · Current Hypertension Reports · doi:10.1007/s11906-022-01227-z · Cited by 13
The Advent of Cuffless Mobile Device Blood Pressure Measurement: Remaining Challenges and Pitfalls
Lee, H., & Burkard, T. (2022) · Korean Circulation Journal · doi:10.4070/kcj.2021.0405 · Cited by 13
Jang, Y., Seo, J.-M., Ihm, S., Lee, H., & on behalf of the Korean Society of Hypertension (2023) · Clinical Hypertension · doi:10.1186/s40885-023-00242-9 · Cited by 13
Yoon, Y., Kim, J., Lee, K. J., Cho, D., Oh, J. K., Kim, M., Roh, J., Park, H. W., & Lee, J. (2023) · JMIR mhealth and uhealth · doi:10.2196/44147 · Cited by 12
SEA 2024 Standards for Global Control of Vascular Risk
Mostaza, J. M., Pintó, X., Armario, P., Masana, L., Real, J. T., Valdivielso, P., Arrobas-Velilla, T., Baeza‐Trinidad, R., Calmarza, P., Cebollada, J., et al. (2024) · Clínica e Investigación en Arteriosclerosis (English Edition) · doi:10.1016/j.artere.2024.06.001 · Cited by 11
Zelveian, P., Topouchian, J. A., Hakobyan, Z., Asmar, J., Gharibyan, H., & Asmar, R. G. (2022) · Vascular Health and Risk Management · doi:10.2147/vhrm.s351313 · Cited by 11
Self-citationEadon, M. T., Cavanaugh, K. L., Orlando, L. A., Christian, D., Chakraborty, H., Steen-Burrell, K.-A., Merrill, P., Seo, J., Hauser, D., Singh, R., et al. (2022) · Contemporary Clinical Trials · doi:10.1016/j.cct.2022.106813 · Cited by 11
Bothe, T. L., Hulpke‐Wette, M., Barbarics, B., Patzak, A. R., & Pilz, N. (2023) · Blood Pressure · doi:10.1080/08037051.2023.2255704 · Cited by 11
Tan, S. Y. L., Chai, J. X., Choi, M., Javaid, U., Tan, B. P. Y., Chow, B. S. Y., & Abdullah, H. R. (2025) · JMIR Formative Research · doi:10.2196/60455 · Cited by 12
Asymptomatic postprandial hypotension in patients with diabetes: The KAMOGAWA‐HBP study
Kitae, A., Ushigome, E., Hashimoto, Y., Majima, S., Senmaru, T., Osaka, T., Okada, H., Hamaguchi, M., Asano, M., Yamazaki, M., et al. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13418 · Cited by 10
Zou, Y., Wu, Q., Liu, T., Wang, J., Liu, L., & Wang, X. (2021) · European Journal of Cardiovascular Nursing · doi:10.1093/eurjcn/zvab066 · Cited by 10
Self-citationFesto, C., Vannevel, V., Ali, H., Tamrat, T., Mollel, G. J., Hlongwane, T., Ayesha, K., Alland, K., Barreix, M., Mehrtash, H., et al. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00804-z · Cited by 10
Validation of an automated home blood pressure measurement device in oldest-old populations
Godai, K., Kabayama, M., Saito, K., Asayama, K., Yamamoto, K. I., Sugimoto, K., Ohkubo, T., Rakugi, H., & Kamide, K. (2019) · Hypertension Research · doi:10.1038/s41440-019-0330-7 · Cited by 10
Automated blood pressure measuring devices: how are they clinically validated for accuracy?
Ringrose, J. S., & Padwal, R. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00761-2 · Cited by 9
Baldassarre, D., Iacoviello, L., Baetta, R., Roncaglioni, M. C., Condorelli, G., Remuzzi, G., Gensini, G., Frati, L., Ricciardi, W., Conaldi, P. G., et al. (2023) · BMJ Open · doi:10.1136/bmjopen-2023-072040 · Cited by 11
Self-citationNtineri, A., Theodosiadi, A. G., Menti, A., Kyriakoulis, K. G., Ntousopoulos, V., Κόλλιας, Α., & Stergiou, G. S. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003341 · Cited by 9
Self-citationAccuracy of blood pressure measurement across BMI categories using the OptiBP™ mobile application
Caillat, M., Degott, J., Wuerzner, A., Proençain, M., Bonnier, G., Knebel, J., Stoll, C., Christen, U., Durgnat, V., Hofmann, G., et al. (2022) · Blood Pressure · doi:10.1080/08037051.2022.2132214 · Cited by 6
Liang, M., Liu, J., Wang, H., Chu, H., Zhu, M., Jiang, L., Zong, Y., & Wan, M. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ada418 · Cited by 8
Industry perspectives on the global use of validated blood pressure measuring devices
Li, J., Frick, G., Herberigs, K., Matsumura, P., Sarkis, J., Verberk, W. J., & Wojcik, C. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00717-6 · Cited by 8
Self-citationKim, Y., Ohn, D., Kim, S. H., Kim, D., Park, S. M., Cho, I., Ihm, S., Sung, K., Oh, K. W., Shin, J.-H., et al. (2022) · Medicine · doi:10.1097/md.0000000000032299 · Cited by 8
Feasibility of watch-based blood pressure monitoring device in daily blood pressure monitoring
Lee, Y., Park, S., Park, J., Seo, J.-M., & Lee, H. (2025) · Clinical Hypertension · doi:10.5646/ch.2025.31.e21 · Cited by 7
Lee, S., Joshi, G. P., Son, C., & Lee, G. (2023) · Diagnostics · doi:10.3390/diagnostics13040736 · Cited by 7
Hakobyan, Z., Zelveian, P., Topouchian, J. A., Hazarapetyan, L., & Asmar, R. G. (2023) · Vascular Health and Risk Management · doi:10.2147/vhrm.s413195 · Cited by 7
Self-citationMenti, A., Ntineri, A., Kyriakoulis, K. G., Theodosiadi, A. G., Ntousopoulos, V., Stathopoulou, P. M., Κόλλιας, Α., & Stergiou, G. S. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003753 · Cited by 7
Self-citationJakes, A. D., Wade, J., Vowles, Z., Seed, P. T., Shennan, A. H., Chappell, L. C., & Nzelu, D. (2021) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000552 · Cited by 7
Self-citation
Metadata
- Authors
- Stergiou, G. S., Alpert, B., Mieke, S., Asmar, R., Atkins, N., Eckert, S., Frick, G., Friedman, B., Graßl, T., Ichikawa, T., Ioannidis, J. P., Lacy, P., McManus, R., Murray, A., Myers, M., Palatini, P., Parati, G., Quinn, D., Sarkis, J., Shennan, A., Usuda, T., Wang, J., Wu, C. O., & O’Brien, E.
- Affiliations
- National and Kapodistrian University of Athens (GR)
- University of Tennessee Health Science Center (US)
- Physikalisch-Technische Bundesanstalt (DE)
- Heart and Diabetes Center North Rhine-Westphalia (DE)
- General Electric (United States) (US)
- Dräger (Germany) (DE)
- Omron (Japan) (JP)
- Stanford Medicine (US)
- National Institute for Health and Care Research (GB)
- University of Oxford (GB)
- Newcastle University (GB)
- Sunnybrook Health Science Centre (CA)
- University of Padua (IT)
- IRCCS Istituto Auxologico Italiano (IT)
- Welch Allyn (United States) (US)
- St Thomas' Hospital (GB)
- Nihon Kohden (Japan) (JP)
- National Institutes of Health (US)
- Corresponding author
- Stergiou, George S.
- Asmar, Roland
- Atkins, Neil
- Ioannidis, John P.
- Myers, Martin
- Palatini, Paolo
- Parati, Gianfranco
- Shennan, Andrew
- ORCID
- Venue
- Journal of Hypertension
- Published
- 2018-03
- Volume
- 36
- Issue
- 3
- Pages
- 472-478
- ISSN
- 0263-6352 (ISSN-L)
- PMC
- PMC5796427
- OpenAlex
- W2787867538
- Cited by
- 278
- References
- 19
- Citations by year
- 2026: 49 · 2025: 42 · 2024: 38 · 2023: 31 · 2022: 39 · 2021: 27 · 2020: 24 · 2019: 17 · 2018: 10
- FWCI
- 14.75
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- UCL Discovery (University College London) (submittedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Newcastle University ePrints (Newcastle Univesity)
- Funders
- National Institute for Health and Care Research (NIHR-RP-02-12-015)
- National Institutes of Health (Z99 HL999999)
- Engineering and Physical Sciences Research Council (EP/N025342/1)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- blood pressure measuring devices, device validation, validation protocol, measurement accuracy, international standardization, AAMI, European Society of Hypertension, ISO, hypertension monitoring
- MeSH terms
- Blood Pressure, Blood Pressure Determination, Humans, Hypertension, International Cooperation, Research Design, Reproducibility of Results, Sphygmomanometers, Consensus, Validation Studies as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review